  • Type: KFH-18/KFH-18-1
  • Electric Power: 1, 208/230V~, 60Hz
  • Power Cooling Output: 18000 Btu/h
  • Power Cooling Input: 1610 W
  • Feed current rating: 7.75/7.00 A
  • Seasonal energy efficiency ratio: 13.5 Btu/W hours
  • Dehumidification: 6.3 Pts/h
  • Maximum input power consumption: 2200 W
  • Maximum rating of the fuse: 15 stroke A
  • Minimum value of the rating of the circuit: 15 A
  • Manufacturing Company for the Compressor: Shanghai Hitachi
  • Classification of the compressor: Rotor
  • Input Power for the Compressor (Electrical): 1685W (230V)
  • The current that will be utilized: 7.6 A
  • Current consumed when rotor is locked: (LRA):39 A
  • Air supply conducted indoors: 706 CFM
  • Sound Pressure level – Indoor Unit: (Hi/Mi/Lo): 54/52/50 dB(A)
  • Size specifications (for Indoor Unit): inch 46 3/8 x 12 7/8 x 9
  • Weight (in Pounds) Gross-weight: Indoor Unit 38.5/53 lb
  • Type of Refrigerant Used: R22
  • Amount of Charge per Foot: 0.53 oz/ft
  • Pressure / Temperature Discharge side 362.5 Psig
  • Pressure/Temperature Suction side 145 Psig
  • Longest acceptable refrigerant pipe: 492 ft
  • High/ Maximum vertical differences: 32.8 ft
  • Range of Operating Temperatures for System: 61-86°F
  • Range of Ambient Temperatures: 50-118.4 °F

Frequently Asked Questions

Q: What is the model number of the device?

A: You may refer to the model as KFH-18/KFH-18-1.

Q: What is the voltage required by this air conditioner?

A: The voltage required for this air conditioner is 208/230V~,60Hz.

Q: What is the cooling power of this air conditioner?

A: The cooling power is 18,000 Btu/h.

Q: Which refrigerant is used in this air conditioner?

A: This type of air conditioner uses R22 refrigerant.

Q: What is the maximum length of refrigerated pipe that can be used?

A: The maximum length of refrigerated pipe that can be used is 492 ft.

Q: For how many years is the compressor covered under warranty?

A: There is compressor warranty for 5 years.

Q: Does the air conditioning system need to be designed for high ambient temperature conditions?

A: Yes, the device can work within the temperature range of 50-1184 °F.

Q: What can be done in the event of an unusual smell coming from the unit?

A: You are advised to cease all operations and unplug the unit before consulting with a dealer.

Q: How much noise does the air conditioner produce indoors?

A: In the case of indoors, the noise level is 54/52/50 dB(A) at high,moderate and low speeds respectively.

User Manual

Page 1
Soleus Air KFH-18, KFH-18-1 User Manual
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Loading...