Soleus Air KFH-18, KFH-18-1 User Manual

Specifications and Main Features

  • Type: KFH-18/KFH-18-1
  • Electric Power: 1, 208/230V~, 60Hz
  • Power Cooling Output: 18000 Btu/h
  • Power Cooling Input: 1610 W
  • Feed current rating: 7.75/7.00 A
  • Seasonal energy efficiency ratio: 13.5 Btu/W hours
  • Dehumidification: 6.3 Pts/h
  • Maximum input power consumption: 2200 W
  • Maximum rating of the fuse: 15 stroke A
  • Minimum value of the rating of the circuit: 15 A
  • Manufacturing Company for the Compressor: Shanghai Hitachi
  • Classification of the compressor: Rotor
  • Input Power for the Compressor (Electrical): 1685W (230V)
  • The current that will be utilized: 7.6 A
  • Current consumed when rotor is locked: (LRA):39 A
  • Air supply conducted indoors: 706 CFM
  • Sound Pressure level – Indoor Unit: (Hi/Mi/Lo): 54/52/50 dB(A)
  • Size specifications (for Indoor Unit): inch 46 3/8 x 12 7/8 x 9
  • Weight (in Pounds) Gross-weight: Indoor Unit 38.5/53 lb
  • Type of Refrigerant Used: R22
  • Amount of Charge per Foot: 0.53 oz/ft
  • Pressure / Temperature Discharge side 362.5 Psig
  • Pressure/Temperature Suction side 145 Psig
  • Longest acceptable refrigerant pipe: 492 ft
  • High/ Maximum vertical differences: 32.8 ft
  • Range of Operating Temperatures for System: 61-86°F
  • Range of Ambient Temperatures: 50-118.4 °F

Frequently Asked Questions

Q: What is the model number of the device?

A: You may refer to the model as KFH-18/KFH-18-1.

Q: What is the voltage required by this air conditioner?

A: The voltage required for this air conditioner is 208/230V~,60Hz.

Q: What is the cooling power of this air conditioner?

A: The cooling power is 18,000 Btu/h.

Q: Which refrigerant is used in this air conditioner?

A: This type of air conditioner uses R22 refrigerant.

Q: What is the maximum length of refrigerated pipe that can be used?

A: The maximum length of refrigerated pipe that can be used is 492 ft.

Q: For how many years is the compressor covered under warranty?

A: There is compressor warranty for 5 years.

Q: Does the air conditioning system need to be designed for high ambient temperature conditions?

A: Yes, the device can work within the temperature range of 50-1184 °F.

Q: What can be done in the event of an unusual smell coming from the unit?

A: You are advised to cease all operations and unplug the unit before consulting with a dealer.

Q: How much noise does the air conditioner produce indoors?

A: In the case of indoors, the noise level is 54/52/50 dB(A) at high,moderate and low speeds respectively.