Soleus Air KC-45H User Manual

Page 1
18000 BTU
Room Air Conditioner
OPERATING AND INSTALLATION MANUAL Model: KC-45H
with Heat Pump
operation, please read this manual and keep it for
future reference.
Page 2
TABLE OF CONTENTS
INTRODUCTION……………………………..…………………………………….…................................1
SAFETY INFORMATION………………………………………………....…………........…..……...….1-2
ELECTRICAL REQUIREMENTS…………………………………...………..………..…...............……2-3
NORMAL CARE AND MAINTENANCE……………………………………………….…..………..…3-5
GENERAL OPERATING INSTRUCTIONS…………………………………………………….......……..5
INSTALLATION INSTRUCTIONS………………………………………………..……….………..…6-11
OPERATING CONTROLS……………………………………………………………………..…………12
BEFORE CALLING SERVICE………………………………………………….…………..……………13
WHEN SERVICE IS REQUIRED………………………………………………………...........…………14
ANY QUESTIONS?…………………………………………………………………….……....…………14
THROUGH-THE-WALL INSTALLATION INSTRUCTIONS..…………………………………......15-16
SPECIFICATION.……………………………………………………………………………....…………17
WARRANTY…………………………………………………………………………………....………...18
Thank you for selecting Soleus Air. To ensure proper operation, please read this manual and keep it for future reference.
This mark indicates a direction/procedure that must be followed!
Page 3
Introduction
Room air conditioners cool, dehumidify, and filter air inside your home. Heat pump and electric heat models offer both heating and cooling. Opening sections of manual provide general information for all room air conditioner models. Operating Controls section describes operation of controls for each model. After reading the opening sections, turn to Operating Controls section and find the panel layout that matches the model of your unit.
Read entire manual thoroughly before beginning installation and operation of your new room air conditioner. Be sure you have all necessary tools and materials on hand for the job. Study illustrations to familiarize yourself with important details of the installation process. Review manual for operating instructions.
NOTE
1. Mechanical experience is required to install air conditioner.
2. Installation can take from 1 to 3 hours, depending on installer’s knowledge and skill.
3. If you encounter problems during installation, call our Technical Support and Warranty Service line at 1-888-8-SOLEUS. If your problem cannot be resolved by phone, contact an authorized Soleus Air brand servicer. Contact and service will be at your expense.
Safety Information
Be sure electrical service is adequate for chosen model of air conditioner. Complete electrical rating for unit is found on serial plate located behind front grille. Electrical outlet must be close enough to unit for power cord to reach without strain. Air conditioner should be the only appliance on individual circuit.
For personal safety and to avoid possible damage to appliance or home, observe all safety instructions highlighted by symbol shown below.
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
After installing unit, reread instructions to ensure each step is complete and that all parts are fastened in place. For best results and to minimize installation time, perform all procedures in the order shown.
To prevent heat related illness or death, do not use this device for unattended cooling of persons or animals unable to react to product failure. Failure of unattended air conditioner may result in extreme heat in area intended for cooling, causing heat related illness or death of persons or animals.
1
Page 4
WARNING
WARNING
HIGH TEMPERATURE STRESS HAZARD This room air conditioner is not meant to provide unattended cooling or life support for persons or animals that are unable to react to failure of the product.
The failure of an unattended air conditioner may result in extreme heat in the cond­itioned space causing overheating or death of persons or animals.
Precautions must be taken to ward off or guard against such an occurrence.
Unpacking
Unpack and visually inspect the unit. Report any damage to the delivering carrier immediately. Remove and discard all packing material. On some models the air conditioner front and/or mounting kit hardware may be packed separately.
Record the model, serial and manufacturing numbers of your unit in the space provided below. This information is found on a nameplate visible after the front of the air conditioner has been removed. The rated voltage, amperage and capacity for your specific model can also be found on this nameplate. Read the warranty packaged with the unit. Keep the warranty and a copy of your sales receipt for future reference. You may also want to record in the space provided the date purchased and the selling dealer.
OWNER'S PRODUCT IDENTIFICATION
MODEL NUMBER
SERIAL NUMBER
MANUFACTURING NUMBER
Owner's Name
Address
To avoid death, personal injury or property damage due to electrical shock:
Observe all local codes and ordinances.
Disconnect electrical power to unit before servicing.
Ground appliance properly. Check with a qualified electrician if you are not
sure this appliance is properly grounded.
DO NOT ground to gas line.
DO NOT ground to cold water pipe if pipe is
interrupted by plastic, non-metallic gaskets, or other insulating (non-conducting) materials.
DO NOT modify plug on power cord. If plug does not fit electrical outlet, have proper outlet installed by qualified electrician.
DO NOT have a fuse in the neutral or ground
circuit. A fuse in the neutral or ground circuit could result in an electrical shock.
DO NOT use an extension cord with this appliance.
DO NOT use an adapter plug with this appliance.
DO NOT pinch power cord.
DO NOT REMOVE warning tag from power cord.
Electrical Requirements
Grounding Instructions
This appliance is equipped with a three-prong grounding plug for protection against possible shock hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code.
Room air conditioners are designed to operate according to requirements on the nameplate and as shown in Table 1. Fuse or circuit breaker ratings must be according to the fuse instruction label and as shown in Table 1. Do not plug models marked “Use on Single Outlet Circuit Only” into a circuit with another appliance or light fixture.
City State Zip
/ /
Date of Purchase
Authorized Dealer
Address
City State Zip
( )
Phone Number
Receptacle Wiring
Receptacle wiring must be of adequate size for unit. Refer to unit identification plate for exact power requirements. Minimum size of wiring, based on power requirements, is:
Units up to 20 amps: 12 gauge 20–30 amp units: 10 gauge
LCDI or AFCI Power Cords
Underwriters Laboratories (UL) and the National Electric Code (NEC) now require power cords that sense current leakage and can open the electrical circuit to the unit. In the
2
Page 5
Unit Plug Receptacle Circuit Rating, Voltage Type Required Breaker, Time Rating On
Delay Fuse Nameplate
NEMA No. 5-15P NEMA No. 5-15R 125V-15AMP 115V
NEMA No. 6-15P NEMA No. 6-15R 250V-15AMP 230/208V rated
at 12 amperes or less
NEMA No. 6-20P NEMA No. 6-20R 250V-20AMP 230/208V rated
over 12 amperes, but not more than 16 amperes
NEMA No. 6-30P NEMA No. 6-30R 250V-30AMP 208V rated over
16 amperes, but not more than 24 amperes
event, the unit does not operate, check the reset button located on or near the head of the power cord as part of the normal troubleshooting procedure.
Use copper wire only. Consumer’s responsibility is to provide proper and adequate receptacle wiring that conforms to all applicable codes. All wiring should be installed by qualified electrician.
Installation
Complete step-by-step installation instructions are furnished with your unit. These instructions will be found on a separate page included with this manual or in the mounting kit assembly. Follow these instructions carefully. Keep these instructions with this manual for future reference. Your unit will be one of the following three designs:
Unit with a window mounting kit
These models are designed for mounting though an opening in a wall. These units can be adapted to window installation by using the optional window mount­ing kit supplied with your unit.
Unit without a window mounting kit
No window mounting kit is supplied with the unit. These models are designed for mounting through an opening in a wall. These units can be adapted to window installation by purchasing an optional window mounting kit. Consult your dealer to choose the kit that is appropriate for your model and installation.
Unit with a separate sleeve
Some Builder models are designed such that the outer case and the chassis can be purchased separately. Through-the-wall installation instructions are included with the outer case. These models can be adapted to window installation by purchasing an optional mount­ing kit.
Room Heat Pumps
Heat pumps work by moving heat instead of creating it. In the summer, the cool indoor coil absorbs heat from your room and moves it outdoors, providing cooling. In the winter, heat pumps reverse this operation. By lowering the temperature of the outdoor coil below the outdoor temperature, the heat pump absorbs the heat from outdoors and moves it inside your house. This heat transferring process is very efficient. For example, at 45°F outdoor temperature, a heat pump can provide 2 ½ watts of heat for every watt of electricity it consumes.
As outdoor temperatures drop, the heating capacity and efficiency of the heat pump declines. At temperatures below 45°F, it is likely that ice will form on the outdoor coil. Heat pump units are designed to operate as a heat pump above approximately 40°F. Below 40°F, these units switch auto­matically from reverse cycle heat pump to auxiliary electric heating. No defrost is required. There is no minimum operating temperature.
Normal Care and Maintenance
WARNING
To avoid property damage, personal injury or death due to electrical shock, turn fan control OFF and remove plug from wall outlet before inspecting unit or performing maintenance.
Annual Inspection
It is suggested that your unit be inspected by your dealer or servicer once a year. It is advisable to have the outer case removed and the unit thoroughly cleaned.
Note: The life of your unit may be greatly reduced if you live in a salt air or other corrosive type environment. Under these conditions, the unit should be removed from its case and completely cleaned at least once a year. At that time any scratches or blisters on the painted surfaces should be sanded and repainted. Placing an algaecide tablet in the outdoor side of the unit’s basepan is suggested in humid areas where algae formation is common.
3
Page 6
Front Grille and Filter Removal
The front contains a removable grille that provides easy access to the air filter. To clean the filter use one of the following methods for filter removal:
METHOD ONE
Grasp filter handle and slide filter out of unit.
Optional Charcoal Air Filter Installation
Remove charcoal air filter from plastic bag. Insert three tabs on right side of filter into three slots on filter frame. Carefully bow middle of filter until two tabs on filter can be inserted into two slots on filter frame. Relax bow.
Reinstall air filter and grille by reversing removal procedure.
Front Grille and Cabinet Cleaning
Grille and cabinet may be cleaned with warm water and mild soap or detergent. Cleaning and polishing compounds are not recommended, as they may damage plastic surfaces.
Air Filter Cleaning
A dirty air filter reduces operating efficiency of unit. Filter should be inspected at least once every week during opera­tion. Clean filter with vacuum cleaner or wash in warm water and mild detergent. Filter should be thoroughly dried before replacing in unit. Do not operate unit without filter in place.
Fan Motor Care
The fan motor is permanently lubricated for long life. There is no need to oil the motor.
Slide-out Chassis Removal from Outer Case
1. Remove front grille by sliding grille to left and pulling out.
2. Remove air filter by sliding to left.
3. Remove four screws holding plastic front to unit and
remove front.
4. If the unit has a screw holding the basepan clip to the
chassis, remove the screw.
CAUTION
To reduce the risk of personal injury be sure to have sufficient help when moving your unit. A room air conditioner can weigh between 70 and 240 pounds.
5. Using basepan handle, pull chassis straight out, slowly
and evenly, until approximately 9-12 inches extends
4
Page 7
from outer case. Use both hands to grasp basepan and pull remaining chassis from outer case.
CHASSIS
PLASTIC FRONT
BASEPAN
CLIP
NOTE: Basepan clip is shipped in plastic bag with mounting
screw and condensate drain cup. Install clip after reinserting chassis into outer case to prevent accidental chassis removal.
General Operating Instructions
While operation of all units is similar, controls vary slightly from model to model. Operating Controls section shows control panel of unit purchased and gives detailed information about operation of controls.
Drain Cup Installation and Use
Your air conditioner uses a system where the water removed from the indoor air (condensate) is channeled to the outdoor side of the unit. The outdoor fan blade has a “slinger” ring attached to it that dips into the water and slings the water onto the outdoor coil surface. This is the sound of water you hear during normal operation. The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner. In normal conditions the unit can evaporate the water as fast as it is removed from the indoor air.
However, in very humid conditions excess amounts of water may drip off the unit chassis. If this proves to be a problem, install the condensate drain cup included with the unit to route excess water where it would not be a problem (see illustration below). To install, remove the unit chassis from the outer case. Insert the condensate drain cup through the recessed ½” hole on the right side bottom flange of the outer case. Once inserted, place a ½” diameter hose or tube on the drain cup bottom spout. The hose allows you to route where you want the excess water to go. Reinsert the unit chassis into the outer case. The unit basepan overflow hole will be positioned directly above the drain cup and will catch any water that might run out.
Initial Start-Up and Cooling
Select the highest fan speed and set temperature control to its coldest position. When the desired temperature is reached, slowly move the temperature control toward a warmer setting until the compressor shuts off. The thermo­stat will then cycle the compressor on and off to maintain this selected temperature. Adjust the fan speed for desired air circulation.
BAFFLES
OUTDOOR LOUVERS
INDOOR GRILLE
Changing Airflow Direction Baffles
Airflow on unit may be diverted left or right from center by baffles. Upward and downward air discharge is provided by tilting louvers. Adjust baffles and tilt louvers for desired airflow pattern.
Airflow Around Unit
Check the indoor grille and outdoor louvers for obstructions to airflow. Do not block the airflow to and from the unit. If air is obstructed and/or deflected back into the unit, the air conditioner’s compressor may cycle on and off rapidly. This could damage your unit.
Condensate
Drain Cup
1/2" Diameter
Hose
Outer Case
Switchover Thermostat Control
Emergency heat switch overrides heat pump (compressor) and starts auxiliary electrical heater. When switch is ON, heat pump is locked out.
Use emergency switch only when heat pump fails to
provide adequate heat. Cause of heat pump malfunc­tion should be determined by authorized servicer. Cost of operating unit will increase when emergency heat switch is engaged.
To access and engage emergency switch:
1. Remove front grille, air filter, and plastic front, as de­scribed in Installation Instructions.
2. Remove basepan clip.
3. Slide chassis out of case about two inches.
4. Locate access hole for emergency switch above label on right front of control box.
5. To start emergency heat, insert flathead screwdriver into slot and turn counterclockwise until switch-stop is reached.
6. Return chassis to case.
7. Replace basepan clip, plastic front, air filter, and front grille.
5
Page 8
Installation Instructions
Questions? Soleus Air Technical Support and Warranty Service line 1-888-8-SOLEUS.
Read these instructions completely and carefully.
IMPORTANT Save these instructions for
Note to Installer Be sure to leave these
Note to Consumer Keep these instructions for
Skill level Installation of this appliance requires
Completion time Approximately 1 hour
We recommend that two people install this
Proper installation is the responsibility of the
Product failure due to improper installation is not
BEFOR E YOU BEGIN
local inspector's use.
IMPORTANT Observe all governing codes
and ordinances.
instructions with the Consumer.
future reference.
basic mechanical skills.
product.
installer.
covered under the Warranty.
CAUTION:
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of this air conditioner.
Aluminum house wiring may present special problems consult a qualified electrician.
TOOLS YOU WILL NEED
ELECTRICAL REQUIREMENTS
The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.
Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.
Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.
6
Page 9
Installation Instruction (Continuous)
7
Page 10
)
Installation Instructions (Continuous
1. WINDOW REQUIREMENTS
These instructions are for a standard double-hung window. You will need to modify them for other types of windows.
The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.
All supporting parts must be secured to firm wood, masonry or metal.
The electrical outlet must be within reach of the power cord.
3. REMOVE THE AIR CONDITIONER FROM
THE CASE
A. Remove the locking screw and locking
bracket from the lower frame. Save to reinstall later.
B. Remove the ground screw and save to
reinstall later.
2. STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the stool.
WOOD PIECES WIDTH: 2" LENGTH: THICKNESS: To determine the thickness, place a
Long enough to fit inside the window frame.
piece of wood on the stool to make it 1/2" higher than the top of the storm window frame.
Attach securely with nails or screws provided by the installer.
C. Slide the air conditioner from the case by gripping the
base pan handle and pulling forward while bracing the case.
4. PREPARE THE WINDOW
Cut the window sash seal to the proper length. Peel off the backing and attach the seal to the underside of the window sash.
8
Page 11
)
Installation Instructions (Continuous
5. PREPARE THE CASE
A. Install the top mounting rail with 4 type B
screws from the inside of the case.
B. Insert the frames for the accordion panels
into the top mounting rail and the bottom frame guides. Attach the accordion panels to the side of the case using 3 type A screws on each side.
Note: When attaching the accordion panels, make sure to only screw the inner panels to the case sides.
6. INSTALL THE CASE IN THE WINDOW
A. Carefully slide the case into the window and
center the case. Lower the window behind the top mounting rail. Pull the bottom of the case forward so that the bottom mounting rail is tight against the back of the window stool. Mount the case to the window sill using 4 type E screws. Drill pilot holes, if necessary.
B. Make sure the bolts and nuts are all of the
way in both the left and right V-supports.
C. Position the V-supports on the case bottom
so that they will be near the outside wall. Attach a V-support to each side of the bottom of the case using type C screws, 3 on each side.
9
Page 12
)
Installation Instructions (Continuous
6. INSTALL THE CASE IN THE WINDOW (cont.)
D. Adjust the leveling bolts and nuts against the
outside wall so that the case has a slight tilt to the outside. Tighten nuts with an adjustable wrench. Use a level; about a 1/2 bubble will be the correct case slant to the outside.
7. INSTALL SUPPORT BRACKETS AND THE FOAM TOP WINDOW GAS KET
A. Attach the support brackets with two type D
screws, one on each side.
E. Use a wood block (not supplied) between the
leveling bolts and the wall if the wall is weak or if the weight of the air conditioner falls between the studs in the wall.
F. Extend the left and right accordion panels to
the vertical window sashes. Drill pilot holes and attach the top and bottom corners with 4 type D screws.
B. Cut the foam top window gasket to the
window width.
C. Stuff the foam between the glass and the
window to prevent air and insects from getting into the room.
10
Page 13
)
Installation Instructions (Continuous
8. INSTALL THE AIR CONDITIONER IN THE CASE
A. Slide the air conditioner into the case. Do not
push on the controls or the finned coils. Make sure the air conditioner is firmly seated.
8. INSTALL THE AIR CONDITIONER IN THE CASE (cont.)
G. Pull the coiled power cord from its shipped
position in the air discharge area. Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case. Push the grille frame in. And install the 2 side screws at bottom left and right side of front panel.
B. Reinstall the locking bracket and screw
removed earlier.
C. Reconnect the ground wire to the air
conditioner using the screw removed earlier.
IMPORTANT: The ground wire must be reinstalled to ensure a proper ground.
D. Remove the front grille from its box and
remove the shipping tape.
E. Grasp the inlet grille at the bottom corners
and pull it forward. Unhook it from its top hinges and set it aside.
H. Secure the front grille frame to the case with
one type C screw.
I. Reinstall the filter.
F. Using the tab, pull up slightly on the filter to
release it and pull it down and out.
J. Reinstall the inlet grille. J Connect power.
11
Page 14
Operating Controls
COMFORT ZONETM AND HEAT PUMP MODELS
Fan Control
OFF – Completely shuts off the unit. To prevent blowing fuses, wait two minutes after turning the unit off before turning it on again.
LOW COOL – Filters and circulates room air with the fan running continuously on low speed. Also cools and dehu­midifies while the compressor is running. Select this setting for quiet cooling operation.
HIGH COOL – Filters and circulates room air with the fan running continuously on high speed. Also cools and dehu­midifies while the compressor is running. Select this setting for maximum air circulation and cooling effect.
LOW HEAT – Filters and circulates room air with the fan running continuously on low speed. Also heats while the compressor or electric heat is running. Select this setting for quiet heating operation.
HIGH HEAT – Filters and circulates room air with the fan running continuously on high speed. Also heats while the compressor or electric heater is running. Select this setting for maximum air circulation and heating effect.
FAN ONLY– Select this setting for circulating or exhausting room air without cooling.
Temperature Control
Slide this control to the left for a warmer room temperature, to the right for a cooler room temperature.
Vent Control
Choose one of the following two settings by sliding the vent control under the appropriate marking:
EXHAUST – Exhausts room air to the outdoors. Also circulates and filters room air. This position can be used to exhaust stale or smoky air. To conserve energy, it is advised that the Fan Control be in the Fan Only setting when using this feature.
CLOSED – Exhaust damper is closed. Unit circulates and filters room air. This position should be used for normal cooling operation.
12
Page 15
Before Calling Service
WARNING
To reduce the risk of electric shock, personal injury, or death, turn the fan control to the off position and remove the unit plug from the wall outlet before doing any inspection or maintenance work.
The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause and suggested remedies are given for each problem.
If the problem cannot be fixed using the suggested remedies, see WHEN SERVICE IS REQUIRED section.
PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY
UNIT WILL NOT RUN No power to unit Push reset button on power cord.
Set Fan Control to position other than OFF.
Make sure plug is firmly seated in outlet.
Check for blown fuses, tripped circuit breakers.
LITTLE OR NO COOLING
LITTLE OR NO HEATING (fan and compressor run)
LITTLE OR NO COOLING
Fresh air/exhaust damper open
Obstructed indoor or outdoor airflow
Dirty air filters
Unit undersized for application
Temperature Control not set properly For cooling, turn Temperature Control to cooler setting.
Set vent to CLOSED.
Remove obstruction from indoor grille or outdoor louvers.
Dirty air filter. Clean or replace, as needed.
Check with dealer to determine proper capacity unit for application.
LITTLE OR NO HEATING (only fan runs)
NOISY UNIT Loose front on mounting assembly
Weak building construction
Water hitting fan blade
Unit oversized for application: compressor cycles on and off frequently
MOUNTING SUPPORT NOT INSTALLED
FROST ON INDOOR COIL Dirty air filter
FROST ON OUTDOOR COIL (heat pump models only)
ODORS IN COOLING Mold, mildew, or algae formation on wet
ODORS IN HEATING Normal for first time electric heater is
Storm window frame installed in window Some models require removal of storm window frame before
Normal for low outdoor temperatures
Normal for outdoor temperatures at or below 45°F
surfaces
used each season
For heating, turn Temperature Control to warmer setting.
Tighten any loose parts.
Provide additional support for unit.
Normal in high humidity. Stop noise by removing drain plug or adding condensate drain cup.
Check with dealer to determine proper capacity unit for application.
installation.
Clean air filter by vacuuming or washing with water and mild soap.
Turning Temperature Control to warmer setting reduces occurrence and duration of frost.
Call for service only if unit does not heat room and you have checked all problems and remedies listed under LITTLE OR NO HEATING.
To reduce algae growth, use algaecide tablet in base pan; remove drain plug; add condensate drain cup and hose. Thoroughly clean unit.
Caused by dust accumulation during unused months. Odor dissipates quickly with heater use.
13
Page 16
When Service Is Required
Your room air conditioner dealer can give you the name of your nearest Authorized Service Center. Help them give you prompt service by providing:
An accurate description of problem.
Complete model, serial, and manufacturing (P)
numbers from serial plate.
Proof of purchase (sales receipt) upon request.
Repair by unauthorized servicer that results in subsequent failure of unit voids warranty. Warranty details are contained in warranty certificate enclosed with unit.
Keep accurate records of service calls, including what was done, servicer’s name, and date of service.
Any Questions?
Most of your questions can be answered by your local Soleus Air brand dealer. Check with your dealer first if you need any further information regarding the operation, maintenance, or service of your unit. Then, if you should have any matters which are not resolved locally.
CONSUMER INFORMATION LINE 1-888-8-SOLEUS
(Technical Support and Warranty Service)
14
Page 17
r
Thru-wall Installation Instructions
Kit RS100 for Soleus Air brand Compact Room Air Conditione
Introduction
This instruction sheet provides guidelines for installing a compact air conditioner through an outside wall.
General Instructions
All Soleus Air brand Compact Room Air Conditioners feature a slide-out chassis. Chassis and front cover must be removed from outer case for installation.
Installing an air conditioner through a wall requires extensive carpentry and/or masonry experience. Thru-wall installations performed by inexperienced or unqualified individuals can result in costly damage to home.
Air Conditioner Dimensions
The following figures show the outside dimensions of air conditioner with chassis installed, and dimensions of outer case with chassis removed.
In order to reinstall the chassis and reattach the air conditioner front cover, the installed outer case must be square and level from side to side. Use wood shims between sides of case and finished opening– especially where case is secured to opening–to prevent warping or distorting. Check installed case for distortion using carpenter’s square.
A finished opening 26 1/8 - inches wide x 17-inches high is recommended. The lower left inside corner of opening must be within 5 feet of an appropriate electrical outlet (see Use and Care manual for electrical requirements.)
When wall thickness exceeds 9 -inches, opening must be modified to allow air to enter side louvers on case (see special instructions on back ). Do not install air conditioner in walls thicker than 11 inches.
2/5 -
Air Conditioner Dimensions
(with chassis installed)
Dimensions of Finished Opening
Masonry Construction
See CAUTION under General Instructions. In
masonry walls, cut or build a finished opening 17­inches high by 26 properly positioned in opening, secure it in place with mortar or concrete nails driven through holes in sides of outer case (shim case and predrill holes before securing with nails).
Outer Case Dimensions
(chassis removed)
15
1/8-inches wide. When case is
Page 18
Brick Veneer or Frame Wall Construction.
w
s
f
(
)
See CAUTION under General Instructions. Cut or build rough opening large enough to allow a framed, finished opening 17-inches high and 261/8-inches wide. When case is properly positioned in opening, secure it to framing material with nails or screws driven through holes in sides of outer case (shim case and predrill holes before securing).
Framing
lumber
261/
8
"
17"
When case is properly positioned in opening, use wood shims to fill any gaps between case and finished opening, especially in area where case will be secured to opening.
Take care not to warp or distort case when installing shims. For condensate drainage, install drainage cup in
drain hole on baseplate of case.
Outercase must project a minimum ¾" beyond inside wall or molding to attach front frame
Lintel and flashing (if required)
nstall case
I
ith 3/8"
lope to outside
or condensate
drainage
9 "
Front of outer case to side air louvers
Framed/Finished Opening
(brick veneer or frame wall construction)
Placement of Outer Case in Opening
Place outer case in opening, flush against one side of opening. Use carpenter’s level and ensure case is level from side to side and has a 3/8-inch slope from front to back (back of case must be 3/8-inch lower than front to ensure proper condensate drainage). If needed, use shims to level case (from side to side) and to obtain proper back slope.
Front of case must project ¾-inch (minimum) beyond inside wall in order to attach air conditioner front frame. If framing indoor side of opening with wood molding (or other decorative material), extend outer case ¾-inch beyond molding.
Caulk all sides
Optional molding
not provided
Installed Case
(brick veneer or frame wall construction shown)
Installation in Wall Thicker Than 9-inches
The side louvers in outer case provide ventilation to air conditioner compressor and fan motor and must not be blocked. When installing unit in a wall over 9-inches thick, provisions must be made in wall opening to ensure free air flow to the side louvers. This can be accomplished by chamfering the vertical portions of the outside opening as shown.
Ventilation louvers on top of case must not be obstructed. Do not attempt to install unit in walls thicker than
2
11
/5-inches.
9"
Front of outercase
11
2
¾" minimum projection
/5"
Side air louvers
4"
26" 34"
(both sides)
4"
Chamfering Walls Thicker Than 9-inches
16
Page 19
Specifications
Cooling Capacity (BTU/HR) 17600/18000
Heating Capacity (BTU/HR) 16500/17000
Electric Heat (BTU/HR) 8600/10700
Rated Voltage 208/230V~
Rated Frequency 60Hz
Design Pressure Lowside 150 P.S.I.
Design Pressure Highside 340 P.S.I.
Cooling AMPS 9.7/8.9
Cooling Watts 1955/2000
Model KC-45H
Cooling EER 9.0
Heating AMPS 8.8/8.3
Heating Watts 1790/1850
Heating EER 9.2
Electric Heat AMPS 15.6/16
Electric Heat Watts 3600
Air Flow Volume (CFM) 589
Dehumidifying Volume (Pint/Day) 116.7
Refrigerant Charge (Ounce) R22 / 34.92 OZ
Dimension (W/D/H)(inch) 25.98” X 30.51” X 16.85”
Dimension of Package (W/D/H)(inch) 29.29” X 36.22” X 19.69”
Net Weight /Gross Weight (lbs) 165.3 / 183
17
Page 20
Warranty
Soleus International Inc. warrants the accompanying Soleus Air 18000 BTU Heat Pump Room Air Conditioner (KC-45H) to be free of defects in material and workmanship for the applications specified in its operation instruction for the period of parts specified below.
5 YEARS FOR COMPRESSOR
1 YEAR FOR OTHER COMPONENTS
This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine maintenance. This warranty does not apply to uncrating, setup, installation, removal of the product for repair or reinstallation of the product after repair.
This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of Soleus International including, but not limited to, any malfunction, defect or failure caused by or resulting from unauthorized service or parts, improper maintenance, operation contrary to furnished instructions, shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect power line voltage, fire, flood or other Acts of God, or normal wear and tear.
Warranty service must be performed by a qualified HVAC contractor. Soleus maintains a centralized service network to provide parts and assist in resolving service problems if difficulties are encountered. Soleus agrees to provide service information, sell repair parts and reimburse the dealer /serviceman for parts in accordance with Soleus International’s Policies and Procedures.
SOLEUS INTERNATIONAL MAINTAINS THAT ALL WARRANTIES, INCLUDING IMPLIED WARRANTY OR MERCHANTABILITY ARE LIMITED TO THE TERMS AND CONDITIONS SPECIFIED ABOVE. SOLEUS INTERNATIONAL DISCLAIMS ANY LIBILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHAL L SOLEUS INTERNATIONAL INC.’S LIABILITY EXCEED THE RETAIL VALUE OF THE AIR CONDITIONER.
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover internet sales, used, salvaged, or refurbished products.
FOR TECHNICAL SUPPORT AND WARRANTY SERVICE
Soleus International Inc.
Tel: 1-888-8 SOLEUS
Monday through Friday, 9:00 AM to 5:00 PM, PST
Email: Contact@soleusair.com
Website: www.soleusair.com