Soleus Air HCC-W08ES-A1, HCC-W10ES-A1 Operating Instructions Manual

Model
HCC-W08ES-A1
HCC-W10ES-A1
Electronic Window Air Conditioner
Operating Instructions
d the instructions and familiarize yourself with all the operational
aspects of your new air conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORT
ANT
SAFETY INSTRUCTIONS
Before installing and using your air conditioner, please read this o manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this owner’s manual.
wner’s manual carefully. Store this
WARNING: To reduce the risk of fire, electrical shock or injury when using the following basic precautions:
Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use a plug adapter.
Do not use an extension cord.
Unplug the air conditioner before servicing
Use two or more people to move and install the air
conditioner
This
is a safety alert symbol. This symbol alerts death. All safety message “DANGER” or
“WARNIN
you
to potential hazard
s will di
rectly follow the safety alert symbol and/
G”.
s that can
harm you or others or even cause
All Safety messages alert you of potential hazards and what can happen if instructions are not followed correctly.
Failure to immediately follow these instruction or even death.
, how to reduce the chance of injury,
s may cause serious injury
your air conditioner, follow
or the words
1
2
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexi­ble cord with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the devise has been manually reset. This is intended to re­duce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet. The LED light will turn on.
2. Press TEST Button, circuit should trip, cutting power to the air conditioner. When this occurs,
3. Press RESET button to restore power to the machine. Once power is restored, the LED light
will turn on again.
If test button is pressed and unit can still be turned on, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting recommendations.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as ONand OFFswitches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
LED LIGHT
the LED light will turn off.
Note: Your units power cord and plug may differ from the one shown.
PACKIN
G LIST
Packing List:
Window A
Remote Control (1)
AAA Batteries (2)
Top Mounting Rail (1)
Insert Strip (1)
Short Screw (8)
Accordion Panels (2)
ir Conditioner (1)
Sash Lock (2)
Foam Seal (1)
Long Screw for Window Locking Bracket & Accordion
Panels (12)
Curtain Lock (2)
Owner’s Manual (1)
3
SPECIFIC
ATIONS
Noise level is measured at
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Power Supply (Ph/V/Hz) 1/115/60 1/115
Rated Cooling Capacity (BTU/h)
Cooli
Rated Current Cooling (Ampera
EER/C.O.P 11.3 11.3
Noise Level dB(A) (H/M/L) 6
Air Flow (H/M/L) CFM 265/247/229 265/247/229
Dehumidifying Capacity
Product Dimensions (W” x D” x
Package Dimensions (W” x D” x H”) 22.5 x 21.25 x 17 22.875 x 24.625 x 16.875
Net/Gross Weight (lbs) 57.3/63.9
Refrigerant Type R-410A R-410A
Plug Type NEMA 5-15P NEMA 5-15P
ng Power Input (Watts)
a distance of 3.28 ft away from the front of the unit in cooling mode.
Model HCC-W08ES-A1
8,000 10,000
708 885
ge) 6.8 7.9
1/59/58 59/57/55
42 Pints per day 55 Pints per day
H”) 19 x 19.25 x 14.625 19 x 21.5 x 14.375
HCC-W10ES-A1
79.3/83.8
/60
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL PRESENTATION OF THE MANUFACTURER. SOLEUS HOME COMFORT HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE
4