Soleus Air HCC-C09H26-A,HCC-C12H26-A Installation And Operating Instructions Manual

As a professional installer you need to know the product better than the customer. This instruction includes all safety
precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this instruction manual. Pay special attention to all safety
warnings.
During installation or maintenance, it is possible to be in a position which is more hazardous than when the unit is in
operation.
Remember it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer
Safety is a matter of common sense, a matter of thinking before acting. Most dealers have a list of specific good safety
practices, follow them.
The precautions listed in this Installation Manual are intended as ractices. However, if there a
direct conflict between existing practices and the content of this manual, the precautions listed here take precedence.
supplements to existed p
ATTENTION INSTALLATION PROFESSIONAL
PACKAGED TERMINAL
AIR CONDITIONER
Installation and Operating Instructions
Model No.:
HCC-C09H26-A
HCC-C12H26-A
4004987
V170303
CONTENTS
IMPORTANT TO THE OWNER2
IMPORTANTTO T
TRANSPORTATION DAMAGE
2
INSTALLATION INSTRUCTIONS
MONTHLY MAINTENANCE AND CLEANING
WIRNG
UNIT FEATURES8
9
AUXILIARY CONTROLS-DIP SWITCHES
NORMAL OPERATING SOUNDS AND CONDITIONS
TROUBLE SHOOTING
NOTES ……………………
NOTES HE SERVICER………………2
…………………………2
UNPACKING THE UNIT… …………………………………2
OPERATING INSTRUCTIONS………………………………
……………………3
………………6
I… …………………………………………………7
…………………………………………………
OPERATING INSTRUCTIONS……………………………
…………………11
……12
ERROR CODES………………………………………………12
…………………………………13
-1-
RECOGNIZE THIS SYMBOL AS
A SAFET Y PRECAUTION
WARNING
HIGH VOLTAGE
DISCONNECT ALL POWER BEFORE SERVICING OR
INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY
BE FAILURE TO DO SO MAY CAUSE
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
PRESENTED,
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR ANY
INJURY OR ARISING FROM IMPROPER
SERVICE OR SERVICE PROCEDURES. IF YOU INSTALL OR
PERFO RM SERVICE ON THIS UNIT, YOU ASSUME
RESPONSIBILITY FOR ANY PERSONAL INJURY OR PROPERTY
DAMAGE WHICH MAY RESULT, MANY JURISDICTIONS
REQUIRE A LICENSE TO INSTALL OR SERVICE HEATING AND
AIR CONDITIONING EQUIPMENT.
PROPERTY DAMAGE
WARNING
IMPORTANT NOTES:
Before using this manual, check the serial plate for
proper model identification.
The installation and servicing of this equipment must
be performed by qualified, experienced technicians
only.
Due to policy of continual product improvement, the
right is reserved to change specifications and design
without notice.
THE FOLLOWING WARNINGS ARE
VERY IMPORTANT FOR SAFETY.
PLEASE READ THEM CAREFULLY
BEFORE INSTALLATION!
1. The air conditioner must be installed by
certific
2. Please check whether there
installation. If not, inst
fety principle to
users.
3. To avoid electric shock or even death,
the socket or terminal blocks for power
supp
series and the units that
have LCDI power cord) must conna
Ground Fault Circuit Interrupter.
4. During installation,the wire connection
must strictly follow the
connected
to the zero line and fire line in the power
system. The connection in reverse is
forbidden. Plea
wire is firmly connected otherwise it is
possible to result in the electrical shock or
death.
ated installers. It's forbidden to
install by those amateurs.
is ground
wire in the power supply system before
allers should refuse
to install and explain the sa
ly of the air conditioner(include 277V,
115V, 208V~230V
ect to
rule that zero line
and fire line of the unit should be
se make sure the ground
OPTIONAL ACCESSORIES
Wall Sleeve Kit
Filter Kit
Stamped Louver Kit
LCDI Power Cord
IR
Remote Controller
NOTE: Refer to sales literature for the appropriate
voltage and amperage selections.
Loading...
+ 1 hidden pages