GM-PAC-12E1
GM-PAC-12E1HP (WITH HEAT)
12,000 BTU Portable
Air
Conditioner
Operating Instructions
Tha
nk you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your
new product. Please take a few moments to thoroughly read the instructions and familiarize yourself
with all the operational aspects of your new Portable Air Conditioner.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store
name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORT
ANT INSTRUCTIONS
Before instal
manual in a safe place for future reference.
1) Always place the unit on a level surface.
2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.
3) Maintain at least 12 inches (50 cm) clearance space around this unit. Do not block or cover air inlet or outlet grilles.
4) The unit must be connected to a correctly grounded power supply.
5) Do not start or stop the unit by inserting or pulling out the power plug.
6) Do not use an adapter plug or extension cord.
ling and using your portable air conditioner, please read this owner’s manual carefully. Store this
7) Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.
8) Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.
9) Do not let children play near this unit.
10) Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the
manufacturer or a qualified service technician.
11) When cleaning the unit, always turn the unit off and unplug the power cord.
2
P
ACKAGE CONTENTS
Portable Air Conditioner
Exhaust Hose (1)
Front Exhaust Hose Adapter (1)
Window Kit Adapter (1)
Rear Exhaust Hose Adapter (1)
Remote Control & AAA Batteries (2 batteries)
Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels)
Owner’s Manual
S
PECIFICATIONS
•
The cooling c
•
Noise level is
apacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.
measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
Power consum
•
These specifi
•
If the environ
•
ption is measured when the fan runs at the highest speed setting.
cations are for reference only. For actual data, please refer to the rating label on the back of the unit.
ment temperature is higher than the max operating temperature or lower than the minimum operating
temperature, the air conditioner may not work properly.
midifier mode works when ambient temperatures are between 61°F - 86°F
Dehu
•
Air Conditioner
•
r Supply (Ph/V/Hz) 1/115/60Hz 1/115/60Hz
Powe
Deh
umidifying Capacity (Pints/Day) 81 81
Rated
Rated
Cooli
Heatin
Rated
Rated
Cooling Capacity (BTU/h) 12,000 12,000
Heating Capacity (BTU/h) - 10,500
ng Power Input (Watts) 1465 1465
g Power Input (Watts) - 1200
Current Cooling (Amperage) 13 13
Current Heating (Amperage) - 10.6
mode operates up to an ambient temperature of 95°F.
Model GM-PAC-12E1 GM-PAC-12E1HP (with Heat)
se Level (dBA) - H/M/L 55/53/51 55/53/51
Noi
Air Flow -
Produ
Produ
Refrig
H/M/L (CFM) 235/205/175 235/205/175
ct Dimensions (W” x H” x D”) 17.75 x 33.125 x 17.125 17.75 x 33.125 x 17.125
ct Weight (Lbs) 80 80
erant Type R-410A R-410A
3
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and
plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord
with no termination on the load side and a LCDI attachment plug on the line side.
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk
of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must
be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed
metal.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:
1. Plug power cord into wall outlet
2. Press TEST Button, circuit should trip, cutting power to the air conditioner
3. Press RESET button for use
If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air
conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Powered by Gree Customer Service for troubleshooting recommendations.
WARNING:
1. DO NOT press the TEST button while the air conditioner is operating.
2. The TEST and RESET buttons should not be used as “ON” and “OFF” switches.
3. The cord and plug are not intended to offer protection to externally connected loads or supply circuits.
4. The cord and plug are intended for indoor use only.
RESET
TEST
4