Soleus Air GM-CAC-08ESE, GM-CAC-12SE, GM-CAC-10SE User Manual

Model GM-CAC-08ESE GM-CAC-10SE
M-CAC-12SE
G
Electronic Casement Window Air Conditioner
Operating Instructions

For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:

Store Name: ____________________________________________________ Location: ______________________________________________________ Date Purchased: _________________________________________________ Serial Number (located on back of unit): ______________________________
IMPORTANT SAFETY INSTRUCTIONS
Before installing and using your air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow the following basic precautions:
Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use a plug adapter.
This is a safety alert symbol. This symbol alerts you to potential hazards that can harm you or others or even cause death. All safety messages will directly follow the safety alert symbol and/or the words “DANGER” or “WARNING”.
Do not use an extension cord.
Unplug the air conditioner before servicing
Use two or more people to move and install the air
conditioner
All Safety messages alert you of potential hazards, how to reduce the chance of injury, and what can happen if instructions are not followed correctly.
Failure to immediately follow these instructions may cause serious injury or even death.
2

SPECIFICATIONS

Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Model GM-CAC-08ESE
Power Supply (Ph/V/Hz) 1/115/60
Dehumidifying Capacity (Pints/Day) 31
Rated Cooling Capacity (BTU/hr) 8,000
Cooling Power Input (Watts) 760
Rated Current Cooling (Amperage) 7.2
Cooling EER 10.5
Noise Level dB(A) (High/Med/Low) 56/54/52
CFM (High/Med/Low) 420/370/320
Power Plug Type NEMA 5-15P
Product Dimensions (W” x D” x H” ) (Inches)
Product Weight (Lbs) 72.8
Refrigerant R-410A
Energy Star Yes No No
14.5” x 23.25” x 20.25”
GM-CAC-10SE
1/115/60
36
10,000
1052
9.2
9.5
60/58/56
550/510/470
NEMA 5-15P
14.2” x 24.5” x 20.3”
TBA
R-410A
GM-CAC-12SE
1/115/60
60/58/56
550/510/470
NEMA 5-15P
14.2” x 24.5” x 20.3”
38.4
12,000
1263
11
9.5
TBA
R-410A
3

IMPORTANT SAFETY INSTRUCTIONS

Read all instructions before using this air conditioner
These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT window. Modification may be necessary when installing in windows made differently than those shown in these instructions.
MEETING ELECTRICAL REQUIREMENTS
OBSERVE ALL LOCAL GOVERNING CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG.
NOTE: If codes permit, and a separate grounding wire is used; it is recommended that a qualified electri-
cian determine that the grounding path is adequate and not interrupted by plastic, non-metallic gas­kets, or other insulating materials.
RECEPTACLE WIRING
Receptacle wiring should be a minimum of 14 gauge. Use copper wire only. It is your responsibility to provide proper and adequate receptacle wiring, installed by an electrician.
ELECTRICAL REQUIRMENTS
A 115 volt (103.5 minimum, 126.5 maximum), 60 Hertz, AC only, 15 ampere fused electrical supply is required. A time delay fuse or time delay circuit breaker is also required. A separate circuit, serving only this appliance, MUST be pro­vided.
WARNING: Electrical Shock and Personal Injury Hazard
Electrical ground is required on this appliance.
DO NOT ground to a gas line.
If a cold water pipe is interrupted by plastic, non-metallic gaskets, or other insulating materials, DO NOT use for
grounding.
Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
DO NOT modify the power supply cord plug. If it does not fit the outlet, have the correct outlet installed by a qualified
electrician.
DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral, or grounding circuit could result in an electrical shock.
DO NOT use an extension cord with this appliance.
Failure to follow these instructions could result in electrical shock, serious injury or death.
ELECTRICAL CONNECTION
Electrical ground is required on this appliance.
Recommended grounding method:
For your personal safety, this appliance must be grounded. This air conditioner includes a power supply cord with a 3-prong grounding plug. To minimize possible electrical shock:
The cord must be plugged into a mating 3-prong grounding-type wall receptacle.
Must be grounded in accordance with National Electrical Code
(ANSI/NFPA 70—Latest version) and
All local codes and ordinances
If a mating 3-prong grounding-type receptacle is not available, it is the responsibility of the consumer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician.
4

PREPARING FOR INSTALLATION

PREPARING FOR INSTALLATION
Installation Tips
For wood-frame casement windows: It may be necessary to construct a frame, using at least 1-inch thick wood, with a
15-1/2-inch wide opening.
For brick or cement building construction: It may be necessary to put a wood stool strip under AC, for mounting pur-
poses.
Tools Required:
Flat-head screwdriver
Phillips-head screwdriver
Carpenter's level
Tape measure
Fine tooth saw
Electric or hand drill
Knife and scissors
Pencil
WARNING: Failure to adhere to the following precautions could result in personal injury and product
damage.
Because this unit weighs about 88 to 105 pounds, it is recommended that you have someone help you when install your new unit, and that you both use proper lifting techniques.
Inspect the condition of the window where unit will be installed. Be sure it will support the weight of the unit.
This appliance must be installed according to all applicable codes and ordinances.
Handle AC with care. AVOID sharp metal fins on front and rear coils.
Make sure your AC does not fall during installation.
Do not use water collected in the unit for drinking. It is not sanitary.

DISCLAIMER

ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
5

PARTS LIST & INSTALLATION

6

INSTALLATION

INSTALLING THE UNIT IN A SLIDING WINDOW
1. Attach support brace to platform as shown.
Use adjustment bolt and hex flange nut to complete
assembly. Choose slot and adjustment bolt hole
locations that will create a 45 degree angle between
platform and support brace. Try assembly in the
window to determine if platform will rest properly, and
allow proper slope (3/16-inch lower on outside).
NOTE: If you are planning to use a siding protection
board (see Step 5) on the outside of your
house, hold board in place when testing assembly in
window.
2. Measure, and lightly mark a line 8-11/16 inches
from window jamb.
NOTE: If any sash stop protrudes more than 1
inch from the side window jambs, the 8-11/16-inch
measurement must be increased accordingly.
Screen and storm window frames may also require
adjustments to the measurement.
3. Center platform assembly on the line with inside
platform tab pressed against inside edge of window
track. Using the holes in the platform as a guide,
mark and drill two 9/64-inch diameter holes. Drill
holes in either track or stool.
CAUTION
Property Damage Hazard—Failure to adhere to the following precautions could result in damage to window or the air conditioner. Make sure the wood stool or window track is securely attached to the building construction. Use longer screws in sub-framing if necessary.
7