Soleus Air GB-TTW-10ESE, GB-TTW-12ESE, GB-TTW-12ESEZ, GB-TTW-14 User Manual

Model Number: GB-TTW-10ESE GB-TTW-12ESEZ GB-TTW-12ESE GB-TTW-14
Electronic Through the Wall Air Conditioner
Operating Instructions
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner.

For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:

Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT SAFETY INSTRUCTIONS
Before installing and using your air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow the following basic precautions:
Plug into a grounded 3 prong outlet.
Do not remove the ground prong.
Do not use a plug adapter.
Do not use an extension cord.
Unplug the air conditioner before servicing
Use two or more people to move and install the air
conditioner
This is a safety alert symbol. This symbol alerts you to potential hazards that can harm you or others or even cause death. All safety messages will directly follow the safety alert symbol and/or the words “DANGER” or “WARNING”.
All Safety messages alert you of potential hazards, how to reduce the chance of injury, and what can happen if instructions are not followed correctly.
Failure to immediately follow these instructions may cause serious injury or even death.
2

IMPORTANT SAFETY INSTRUCTIONS

Read all instructions before using this air conditioner
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and other warnings.
ACCIDENT PREVENTION
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
Be sure the electrical service is adequate for the model you have chosen. This information can be found on the rating label located on the side of the cabinet or behind the grille.
If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass prior to installation. If the windows is a triple-track type with a screen panel included, remove the screen completely before installation.
Be sure the air conditioner has been securely and correctly installed according to the installation instructions provided with this manual. Save this manual and the installation instructions for future use when removing and reinstalling the unit.
When handling the air conditioner, be careful to avoid cuts form sharp metal fins on the front and rear coils.
NOTE: The power supply cord on this air conditioner contains a current detec-
tion device designed to reduce the risk of fire. Please refer to the section “Operation of
Current Device” for details. In the event that the power supply cord is damaged, it
cannot be repaired it must be replaced with a cord from Soleus Air Powered by Gree.
ELECTRICAL INFORMATION
The complete electrical rating of your new air conditioner is stated on the product rating label located on the unit. Refer to the ratings on the label when checking electrical requirements.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounded plug for protection against shock hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, a qualified electrician will have to install the proper receptacle.
Do not run the air conditioner with a protective cover on the outside of the unit. This could result in mechanical damage within the air conditioner.
Do not use an extension cord or an adapter plug.
3

IMPORTANT SAFETY INSTRUCTIONS

READ THIS SECTION BEFORE ATTEMPTING TO OPERATE YOUR AIR CONDITIONER
The power supply cord contains a current device that senses damage to the power cord. Follow the instructions below to test your power cord.
1. Plug in your air conditioner
2. The power supply cord will have TWO buttons on the plug. Press the TEST button. You will notice a click as the RESET button pops out.
3. Press the RESET button. The button will click when the RESET button engages.
4. The power supply cord is now supplying electricity to the unit.
NOTE:
Do not use this device to turn the unit on or off.
Always make sure the RESET button is engaged for correction operation
The power supply cord must be replaced if it fails to reset when either the TEST button is pushed, or it cannot be
reset. A new one can be obtained from Soleus Air Powered by Gree.
If the power supply cord is damaged, it CANNOT be repaired. It MUST be replaced with one obtained from Soleus Air Powered by Gree.
OPERATION OF CURRENT DEVICE

DISCLAIMER

ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
4

SPECIFICATIONS

Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Model GB-TTW-12ESEZ
Power Supply (Ph/V/Hz)
Dehumidifying Capacity (Pints/Day)
Rated Cooling Capacity (BTU/h)
Cooling Power Input (Watts)
Rated Current Cooling (Amperage)
EER 9.4
Noise Level dB(A) (High/Med/Low)
CFM (High/Med/Low) 300/266/225
Power Plug Type NEMA 5-15P
Dimensions (W x H x D)
Package Dimensions (W x H x D)
GB-TTW-10ESE
1/115/60Hz
60
10000
1060
9.5
9.4
58/56/54
290/260/230
NEMA 5-15P
24 x 14.50 x 20.625
28.50” x 16.375” x 27.125”
1/115/60Hz
81.6
12000
1280
11.7
59/57/55
24” x 14.50” x 20.625”
28.5” x 16.375” x 27.125”
GB-TTW-12ESE
1/230-208/60Hz
81.6
12000/11700
1280/1240
6.0/6.5
9.4
59/57/55
300/266/225
NEMA 6-15P
24” x 14.50” x 20.625”
28.5” x 16.375” x 27.125”
GB-TTW-14
1/230-208/60Hz
100.8
14000/13600
1650/1600
7.0/7.5
8.5
59/57/55
320/290/260
NEMA 6-15P
24” x 14.50” x 20.625”
28.5” x 16.375” x 27.125”
Net/Gross Weight (lbs) 76.2/88.3
Refrigerant R-410A
74/86
R-410A
76.2/86
R-410A
78.3/90.4
R-410A
NORMAL OPERATING SOUNDS
5
Loading...