1. When using this electric unit, basic safety precautions should always be followed to reduce the risk of
fire, electric shock, and injury to persons, including the following:
2. Read ALL instructions before using this unit.
3. Plug the circulator directly into a polarized 120V A/C electrical outlet.
4. Do not push finger or any object through the grilles and do not touch the circulator blade during use.
5. The circulator should be used on a stable and level surface.
6. Do not expose the circulator to excessive heat or humidity. This could cause damage to the elec-
trical components.
7. Do not immerse with any type of liquid. Do not use near water.
8. The circulator should kept out of the reach of children. Close supervision is necessary when the circu-
lator is use by or near children.
9. To reduce the risk of fire or explosion, do not store or use gasoline or other flammable vapors or liq-
uids in the vicinity of the circulator.
10. Do not operate this or any appliance with a damaged cord, if the unit malfunctions, or if it has
been dropped or damaged in any manner. Connect to polarized outlets only.
11. Do not cover the cord or place near heat sources. Keep the cord away from high traffic areas, and
do not submerge in water.
12. Unplug the circulator before moving or servicing.
13. To reduce the risk of fire or electric shock, do not use this circulator with any solid-state speed control
device.
14. To disconnect, grip the plug and pull from wall outlet. Never pull on the cord to unplug.
15. This appliance is not intended for use by persons ( including children) with reduced physical, senso-
ry or mental capabilities, or lack of experience and knowledge, unless they have been given super-
vision or instruction concerning use of the appliance by a person responsible for their safety.
16. Be extra cautious when children and infants are around during use.
IMPORTANT INSTRUCTIONS
PURCHASE INFORMATION
3
AIR901F/906F/907F employs overload protection (fuse). A blown fuse indicates an overload or short-circuit situa­tion. If the fuse blows, unplug the product from the outlet. Replace the fuse per the instructions below and check the product. If the replacement fuse blows, a short-circuit may be present and the product should be discarded or returned to an authorized service facility for examination and/or repair.
HOW TO REPLACE THE FUSE
1. Unplug the fan from the outlet. Place the plug on a firm, flat surface. Open the fuse cover, located on the top of the plug, using your thumb or a flathead
screwdriver to slide the over towards the prongs.
NOTE: Ensure that the fuse cover is completely open before attempting to remove the fuse.
2. Remove the fuse carefully by using a small screwdriver to pry the fuse out of the compartment by the metal ends of the fuse.
3. Risk of fire. Insert a new 2.5 Amp, 125 Volt fuse into the fuse compartment, making sure that the fuse is securely in place.
4. Slide the fuse cover closed completely. If the fuse cover is difficult to close, make sure the fuse is properly secured in place by pressing down on the metal ends of the fuse.
CAUTION: Risk of fire. Do not replace the attachment plug. It contains a safety device (fuse) that should not be removed. Do not use the product if the attachment plug is dam­aged.
To avoid a risk of fire, only replace with a 2.5 Amp, 125 Volt fuse.
To order a new fuse, contact SoleusAir at: (877)-976-5387
ELECTRIC SAFETY
4
WARNING: This circulator is equipped with a polarized plug (one blade is wider than the other). The
plug is intended to fit into a power outlet only one way, with the wide blade in the wide slot. This is a safe­ty feature; if you are unable to insert the plug fully into the outlet, try reversing the plug. If the plug still does not fit, contact a qualified electrician.
DO NOT DEFEAT THE SAFETY PURPOSE OF THE POLARIZED PLUG.
Model Number AIR901F AIR905F AIR906F AIR907F
Power Consumption (Watts)
25 W 8 W 22W 22 W
Power Source 120V/60Hz USB DC 5V 120V/60Hz 120V/60Hz
Noise Level 30-58 dB(A) 30-58 dB(A) 30-58 dB(A) 30-58 dB(A)
Motor Speed
(Low to High)
300-1850 rpm 780-1700 rpm 300-1850 rpm 300-1850 rpm
Product Weight 5.1 lbs. 3.0 lbs. 6.3 lbs. 7.7 lbs.
Product Dimensions (W x D x H)
11-7/8’’x 9-7/8’’ x 14”
8-2/5’’x 11-1/4’’ x
13-1/8’’
11-1/2” x 11-1/4” x
15’5/8”
11-1/2” x 11-1/4”
x (21-3/4’’~26”)
PACKAGE CONTENTS
SPECIFICATIONS
SoleusAir Air Circulator
Operating Instructions
Remote Control (For model AIR901F/906F/907F)
USB Charger (For model AIR905F Only)
Loading...
+ 7 hidden pages