General Dehumidifier Information
RECOMMENDED HUMIDITY LEVELS
Spring/Summer: 30% - 50%
Fall/Winter: 30% - 40%
WARM AIR EXHAUST IS NORMAL
During operation your dehumidifier will exhaust warm air from the side of the unit. This is normal operation.
EMPTYING THE BUCKET
The more moisture your dehumidifier removes from the air, the more often you may have to empty the bucket
(unless you are using the continuous drainage option). The number of times the bucket will be emptied de-
pends on the dehumidifier model.
Model Number
Reference Number
HCT-D30-A
TDA30
HCT-D45E-A
TDA45E
HCT-D70E-A
TDA70E
Pints of moisture removed per every
24 hour period
30 Pints 4 Times
45 Pints 6 Times
70 Pints 5 Times
LESS MOISTURE BEING REMOVED OVER TIME IS A GOOD THING!
Maximum number of times to empty
the bucket when operating at full
capacity during a 24 hour period
Using a dehumidifier will cause your area to maintain a more comfortable humidity level. Over time, this
humidity level will become more and more stable. Due to the stable humidity level in the area, the
dehumidifier will need to remove less and less moisture over time.
Please do not be concerned if the dehumidifier is removing less moisture from the air or the bucket is taking
longer to fill up. This is a direct result of your dehumidifier creating a more stable humidity level in your area.
WATER IN THE BUCKET!
There might be a small amount of water present in the bucket before using the dehumidifier for the first time,
which is normal. This is caused by the preliminary testing done by the factory.
2
FEATURES
Removes up to 30/45/70 pints (depending on model) of moisture
from the air every 24 hours depending on the unit you have. This
is not the bucket size.
Adjustable humidistat for precise humidity control.
Digital humidistat displays set humidity level and current room
humidity level.
Operates at temperatures down to 41°F. Perfect for basement
use in the winter.
Automatic defrost function melts away ice from frozen coils for
continuous, worry-free operation.
3-Speed fan allows you to choose between maximum dehumidifying power or quiet operation.
Bucket full indicator and audible alarm signals as soon as the
bucket is full and ready to be emptied.
Ultra quiet operation allows for use almost anywhere. Perfect for
heavy traffic areas like a family room or bedroom.
Loss of power protection remembers all settings even when
power is interrupted.
Auto-restart automatically continues operation when power is restored. No need to manually restart the dehumidifier.
24-Hour Timer automatically turns on and off the unit after the
preset time of 0.5 up to 24 hours.
MyHome modes allow you to choose the location in which you
are using your dehumidifier (Sleeping Space, Living Space or
Basement) for preset comfort and balanced operation.
3
Thank you for choosing a Soleus Air Fueled by TCL Portable Dehumidifier. This owner’s manual
will provide you with valuable information necessary for the proper care and maintenance of your
new product. Please take a few moments to thoroughly read the instructions and familiarize yourself
with all the operational aspects of your new Dehumidifier.
For your own records, please attach a copy of your sales receipt to this manual. Also, write the store
name/location, date purchased, and serial number below:
Store Name: ____________________________________________________
Noise level is measured at a distance of 3.28 ft away from the front of the unit.
Power consumption is measured when the fan runs at the highest speed setting.
These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Model Number
Reference Number
HCT-D30-A
TDA30
Dehumidifying Capacity 30 Pints per day
Power Consumption
(Watts)
Air Flow Volume
(High/Med/Low)
370 Watts
215 / 180 / 155 CFM
Power Source 115 V / 60 Hz
Rated Current
(Amps)
Sound Pressure Level
(High/Med/Low)
Weight
Dimensions
(W x D x H)
13.375” W x 10” D x
3.2 A
51/49/47 dB(A)
31.1 lbs
19.5” H
HCT-D45E-A
TDA45E
45 Pints per day
450 Watts
215 / 180 / 155 CFM
115 V / 60 Hz
4.5 A
51/49/47 dB(A)
33.7 lbs
13.375” W x 10” D x
19.5” H
HCT-D70E-A
TDA70E
70 Pints per day
730 Watts
320 / 290 / 250 CFM
115 V / 60 Hz
6.5 A
53/51/49 dB(A)
46.9 lbs
15.25” W x 11.25” D x
24.875” H
Energy Star No
Bucket Capacity 8.5 Pints
5
Yes
8.5 Pints
Yes
16.9 Pints
CASTER INSTALLATION
1) Remove casters from the bucket.
For the 70 Pint, the four casters can be taken out from the side
of the bucket directly. (Fig. 1)
For the 30 Pint and 45 Pint, the float must be removed first before taking the casters out. After taking out the casters, the float
must be placed back in the correct position in order for the dehumidifier to function properly. (Fig. 2)
Fig. 2
Bucket
Float
support
NOTE: The fourcasters can betaken
out by removing the float from pushing
the float support slightlyoutward.
Float
Two holes on the float support
2) Tilt the dehumidifier no more than 45⁰ and forcibly insert the casters. Make sure the ring around the caster
is flush against the bottom of the dehumidifier.
4 casters in
plastic bag
packed inside
bucket
Fig. 1
Float support
Two axes on the float
NOTE: The two axes on
the float must be inserted
in the holes on the float
support.
CONTROL PANEL & DIGITAL DISPLAY
Bucket Full
LED Indicator
LED Indicator
This button does
not operate or offer
any function
Clean Filter
FILTER
BUTTON
Fan Speed
LED Indicators
FAN
SPEED
BUTTON
Digital Humidistat
Display
INCREASE/DECREASE
HUMIDITY LEVEL
ROOM
MyHome Mode LED Indicators
PRESET
MODE
BUTTON
Child-Lock
LED Indicator
Timer
LED Indicator
TIMER
BUTTON
Power On
LED Indicator
POWER
BUTTON
6
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
1) When first operating the dehumidifier, run it in Continuous mode for 24 hours.
2) Power On and Off
- Press the POWER button once to manually turn the unit on. Press the POWER
button once more to turn the unit off.
3) Humidity Selection
- Press the or buttons to choose the desired relative humidity in the room.
Each press of the button will change the desired room humidity by 5%. The room humidity is selectable
from 35%-80% or continuous. The unit will cycle on and off to maintain the humidity level chosen on the
digital display. If you want the dehumidifier to operate continuously regardless of the room humidity, press
the MODE button until you see “CO” on the digital display. This will enable continuous operation and
the “Continuous” indicator will light up on the control panel.
4) Fan Speed Control - Press the FAN SPEED Button to cycle through the different fan speeds: High,
Medium, and Low. The fan speed can be visually distinguished by the fan speed indicators on the control
panel.
5) Timer Auto On- To program the unit to automatically turn on, press the TIMER button when the unit is
off. Press or to increase or decrease the timer in 30 min increments (.5 hours) up to 10 hours. After 10
hours, each press of the button will increase the timer in 1 hour increments up to 24 hours. Once the
desired time is reached, the unit will automatically turn on.
Timer Auto Shut-Off- To program the unit to automatically turn off, press the TIMER button when the
unit is on. Each press of the or buttons will change the timer setting in 30 min increments ( .5 hours)
up to 10 hours. After 10 hours, each press of the or buttons will increase or decrease the timer in 1
hour increments up to 24 hours. Once the desired time is over, the unit will automatically power off.
7
OPERATING INSTRUCTIONS
6) Bucket Full - When the water bucket is full of water, the unit will automatically shut off , make a beeping
noise, and the Bucket Full Indicator will light up. The dehumidifier will not function until the water
bucket is emptied and placed back inside the unit. The bucket should be cleaned every few weeks to prevent
the growth of mold, mildew and bacteria. Use a mild detergent to clean the bucket. Once clean, completely
dry the bucket and place it back inside the dehumidifier.
NOTE: When the bucket is full or removed from the machine, the compressor will turn off, but
the fan will continue to run for a few minutes. This is completely normal. The dehumidifier
will not be removing moisture from the air at this time.
NOTE: When removing moisture from the air, the dehumidifier will exhaust warm air from the
side exhaust vent.
NOTE: Do not place a full bucket on the floor, because the bottom is uneven.
8
OPERATING INSTRUCTIONS
7) Clean Filter - When the filter needs to be cleaned, the filter indicator will light up (after 250 hours of
use). Remove the filter from the back of the unit by using your thumbs to press down on the filter tabs
directly above the filter. Clean the filter with warm, soapy water. Dry thoroughly before replacing the
filter. Once the filter is completely dry, place the filter back in the unit and press the FILTER button to
reset the filter indicator.
CAUTION: DO NOT OPERATE THE DEHUMIDIFIER WITHOUT THE INCLUDED FILTER
8) MyHome Modes - Preset humidity level settings allow the user to easily move the dehumidifier room-
to- room and select the corresponding mode for the location in which the dehumidifier is operating for
optimum performance. Press the MODE button to choose from Sleeping Space, Living Space or Basement.
9) Child-Lock Mode
- To lock the control panel, press and hold the TIMER button for 3 seconds. Locking the control panel prevents someone from accidentally changing the settings. When locked, the
LOCK Indicator will light up. Press and hold the TIMER button for 3 seconds to unlock the control
panel.
NOTE: Do not clean filter in dishwasher
9
CHOOSING A LOCATION
A Dehumidifier operating in a basement will have little or no effect in drying out an adjacent
enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of
the area.
Do not use outdoors.
This dehumidifier is intended for indoor use only. Place the dehumidifier on a smooth, level
floor surface that is strong enough to support the unit with a full bucket of water.
Allow at least 12”-18” of air flow on all sides.
Place the dehumidifier in an area where the temperature will not fall below 41°F. The coils
can become covered with frost at temperatures below 41°F, which may reduce performance.
Use the dehumidifier in cooking, laundry, bathing and dishwashing areas that have exces-
sive moisture. NOTE: Place the dehumidifier away from a clothes dryer.
Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored.
Use the dehumidifier in a basement to help prevent moisture damage.
The dehumidifier must be operated in an enclosed area to be most effective.
Close all doors, windows and other outside openings to the room.
AUTOMATIC DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.
When the coils are completely defrosted, the compressoror fan(dependingon the model) will automatically restart and
dehumidification will resume.
CONTINUOUS MODE—GARDEN HOSE INSTALLATION AND SETUP
Water can be automatically emptied by attaching a hose to the continuous drainageport on the backofthe dehumidifier. This will
allow the unit to run continuously (dependingon the selectedhumidity level) withouthaving to empty the water bucket. To drain,
simply attach a standard gardenhose (not included). The thread standard for garden hoses in the US andits territories is known as
GHT or "garden hose thread" which has an outer diameter of 1 1/16 inches (1.0625 inches or 27.0 mm) and a pitch of 11.5 TPI.
Place dehumidifier on a level surface.
Unscrew the cap on the back of the unit to access the garden hose nozzle
Thread a garden hose (not supplied) onto the accessible nozzle, lead to a floor drain and cut to length.
Make sure that there are no kinks or knots in the garden hose. (See Picture Below)
Turn on the unit and press the MODE button until set to CONTINUOUS.
Garden Hose Installation Reference Guide
IMPORTANT NOTES:
Placing the dehumidifier on an uneven surface or improper hose installation may result in
water filling up the bucket and causing the unit to shut off. Empty bucket if shut-off occurs,
then check dehumidifier location and hose for proper setup. The bucket must be in place and
securely seated for the dehumidifier to operate.
10
TROUBLESHOOTING
Problem Possible Causes Solutions
Dehumidifier does not start
The dehumidifier is unplugged. Make sure the dehumidifier’s plug is pushed completely into
the outlet.
Dehumidifier does not dry the
air as it should
The fuse is blown / circuit
breaker is tripped.
Dehumidifier has reached its
present level or the bucket is full.
Bucket is not in the proper
position.
Power Failure. There is a protective time delay (up to 3 min.) to prevent trip-
Not enough time allowed for unit
to remove moisture.
Airflow is restricted.
Dirty filter.
The Humidity Control may notbe set low enough.
Doors and windows may not beclosed tightly.
Check the house fuse / circuit breaker box and replace fuse or
reset breaker.
The dehumidifier automatically turns off when either condition occurs. Change to a lower setting or empty the water
bucket and replace properly.
The bucket must be in place and securely seated for the dehumidifier to operate.
ping of the compressor overload. For this reason, the unit may
not start normal dehumidification for 3 min. after it is powered back on.
When first installed, allow at least 24 hours to maintain the
desired dryness.
Make sure there are no curtains, blinds, or furniture blocking
the front orback ofthe dehumidifier. See the CHOOSING A LOCATIONsection onPage 10.
See the CLEAN FILTER section on Page 9.
For drier air,press the button tolower the percent humidity desired in the room, or set the dehumidifier to CO for maximum dehumidification.
Check that all doors, windows, and other openings are securely closed.
Dehumidifier runs too much The area to be dehumidified is
Frost appears on the coils The dehumidifier has recently
Controls cannot be set The compressor will turn off and
Fan Noise Air is moving through the unit. This is normal.
Water on the floor Hose connection may be loose.
Clothes dryer maybe blowing moist air into the room.
Room temperature is too low. Moisture removal is best at higher room temperatures. Lower
too large.
Doors and windows are open. Close all doors and windows to the outside.
been turned on or the room
temperature is below 41°F.
the fan will automatically
continue to run for approximately
3 minutes at a fixed setting.
Hose is attached but not draining
into a drain
Install the dehumidifier away from the dryer. The dryer
should be vented outside.
room temperatures will reduce the moisture removal rate.
This model is designed to operate at temperatures above 41°F.
The capacity of your dehumidifier may not be adequate for
the room size.
This is normal. Frost will usually disappear within 60 minutes.
This is normal. Wait approximately 3 minutes and set the fan
speed at the desired level.
Check the hose connection. See the CONTINUOUS MODE-
GARDEN HOSE INSTALLATION AND SET UP
Section on Page 10.
Disconnect the hose if using the bucket or place the hose near
a drain.
11
WARRANTY
One Year Limited Warranty
Soleus Home Comfort warrants the accompanying Soleus Air Fueled by TCL Dehumidifier to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the
date of original retail purchase in the United States.
If the unit exhibits a defect in normal use, Soleus Home Comfort will, at its option, either repair or replace it, free of
charge within a reasonable time after the unit is returned during the warranty period.
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a
copy of the original purchase invoice.
THIS WARRANTY DOES NOT COVER:
Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in
material or workmanship.
Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions
in the instructions.
Damage to the finish of the case, or other appearance parts caused by wear.
Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Home
Comfort.
Freight and Insurance cost for the warranty service.
Filter and Accessories
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO
ONE-YEAR DURATIONOF THIS EXPRESS LIMITED WARRANTY. SOLEUS HOME COMFORT
DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT
SHALL SOLEUS HOMECOMFORT’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.
This warranty covers onlynew products purchased from our authorized dealers or retailers. Itdoes not cover used, salvaged, or refurbished products.
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow
limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights that vary from state to state.
For Technical Support and Warranty Service
Please Call (888) 876-5387
Or Write To:
Soleus Home Comfort
17911 East Ajax Circle
City of Industry, CA 91748
www.soleushomecomfort.com
12
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.