8 9
This table shows what airows the OSAK-125 kit can meet if you choose to program
the FT247 to run 25% of every 4 hour period.
25%
DWELLING UNIT
FLOOR AREA
(square feet)
NUMBER OF BEDROOMS
0 - 1 2 - 3 4 - 5 6 - 7 > 7
Airow in CFM
< 1,500 120 180 240 300 360
1,501 - 3,000 180 240 300 360 420
3,001 - 4,500 240 300 360 420 480
4,501 - 6,000 300 360 420 480 540
6,001 - 7,500 360 420 480 540 600
> 7,500 420 480 540 600 660
This table shows what airows the OSAK-125 kit can meet if you choose to program
the FT247 to run 33% of every 4 hour period.
33%
DWELLING UNIT
FLOOR AREA
(square feet)
NUMBER OF BEDROOMS
0 - 1 2 - 3 4 - 5 6 - 7 > 7
Airow in CFM
< 1,500 90 135 180 225 270
1,501 - 3,000 135 180 225 270 315
3,001 - 4,500 180 225 270 315 360
4,501 - 6,000 225 270 315 360 405
6,001 - 7,500 270 315 360 405 450
> 7,500 315 360 405 450 495
This table shows what airows the OSAK-125 kit can meet if you choose to program
the FT247 to run 50% of every 4 hour period.
50%
DWELLING UNIT
FLOOR AREA
(square feet)
NUMBER OF BEDROOMS
0 - 1 2 - 3 4 - 5 6 - 7 > 7
Airow in CFM
< 1,500 60 90 120 150 180
1,501 - 3,000 90 120 150 180 210
3,001 - 4,500 120 150 180 210 240
4,501 - 6,000 150 180 210 240 270
6,001 - 7,500 180 210 240 270 300
> 7,500 210 240 270 300 330