ENGLISH DECOR-100 CHZ “VISUAL” Axial Extractor Fans
The DECOR-100 CHZ VISUAL extractor fans are manufactured to the high standards of production and quality as laid down by the international Quality Standard ISO
9001. All components have been checked and every one of the ¿ nal products will have been individually tested at the end of the manufactur­ing process. On receipt of the product we rec­ommend that you to check the following : 1- That it is the correct size. 2- That it is the correct model. 3- That the details on the rating label are those you require: voltage, frequency... The installation must be carried out in accordance with the electrical standards in force in your country.
Installation IMPORTANT: Before installing
and wiring the unit, ensure that the mains electrical supply is discon­nected.
Fig. 1: 1 : Protection grille 2 : Fixing screw 3 : Connection terminals 4 : Outlet with backdraught shutter 5 : Cable entry 6 : Adjustment dial
The DECOR-100 CHZ VISUAL is suitable for wall or ceiling mounting and can either discharge directly the outside or via an individual or central ducting system (see Fig. 2). The unit can be mounted on the wall or ceiling using the four raw plugs and screws provided.
Make a hole in the wall or ceiling of 105 mm dia.
to
If the unit is to be installed with individual ducting, use a standard 100 mm dia. duct. Undo the two grille ¿ xing screws (2), and then the corresponding front grille (1).
Ensure that there are no obstruc­tions to the airflow and that the impeller turns freely. Fix the extractor to the wall in such a way that it is not distorted in order to avoid unnecessary noise generation or problems with the rotation of the impeller. Ensure that the backdraught shutter opens freely and has not being damaged in transit. Introduce the mains cable through the cable entry (5) and ¿ x the fan to the wall so that the ¿ xing screw (2) is above.
The fan should then be wired in ac­cordance with the wiring diagrams enclosed. Finally the external pro­tection grille (1) should be ¿ tted and secured with the ¿ xing screw (2).
Electrical connection
The DECOR-100 CHZ VISUAL fans are designed for use with a single phase electrical supply, with voltage and frequency as indicated on the rating plate of the unit. The units are manufactured with double electrical insulation (Class II) and therefore they do not need an earth connection.
The electrical installation must include a double pole switch with a contact clearance of at least 3 mm. The electrical cable must enter the DECOR-100 CHZ VISUAL through the cable entry point (5). Once the cable has been intro­duced the unit should be wired in accordance with the corresponding diagram.
Page 8
DECOR-100 CHZ
These models are provided with an electronic humidistat which can be adjusted between 60, 70, 80 or 90% RH (relative humidity) and with an automatic run-on-timer, adjustable between 5, 10 or 20 minutes. Both humidistat and timer adjustments can be made using the correspond­ing adjustment dials without the need to remove the front grille of the fan.
HUMIDISTAT
The desired humidity level is se­lected by means of an adjustment dial (6) located on the side of the fan casing. The corresponding relative humidity level, 60-70-80 or 90%, is then visually indicated via one of four neon lights. All models are factory set as standard to a 90% relative humidity level.
OVER-RUN TIMER
All models include an over-run timer which enables the fan to continue to operate after the primary switch has been disconnected (switched off). The over-run time should be set in accordance with local and national building code regulations and also with respect to the pro­portion of humidity encountered. For brief periods of operation the over-run time should be set to the minimum period of 2 minutes. For prolonged periods of operation the over-run time should be set to the maximum period of 20 minutes. This will ensure the most ef¿ cient extraction of the humid air whilst saving time on fan operation.
Operation Case 1: In automatic operation, the humi­distat causes the extractor to oper­ate automatically when the humidity level in the room is higher than the
Automatic operation(¿ g.5)
pre-set level. The extractor will stop automatically when the hu­midity drops below the selected level and after the selected pe­riod set on the over-run timer.
Case 2: Automatic operation as in case (1) but with the facility to override the humidistat by means of the light switch (¿ g.4), when the humidity level in the room is lower than the selected level. In this case, the extractor continues to operate for the selected period of time (over-run timer) after the switch light has been switched off.
If the period of operation is less than 50 seconds then the overrun timer will not operate.
If the period of operation is more than 50 seconds then the over­run timer will operate in accord­ance to the pre-set time period.
ATTENTION: When the humid­ity rate is above the selected value, the automatic option takes precedence over the manual and the unit cannot then be switched off using a switch.
Maintenance
The extractor fan only requires periodical cleaning using a cloth lightly impregnated with a soft detergent.
After Sales Service
We recommend you not to try to dismantle or remove any other parts than those mentioned as any tampering would automati­cally cancel the S&P guarantee. If you detect any fault, contact your S&P dealer.
S&P reserves the right to alter speci¿ cations without notice.