Solatube VENTILATION ADD-ON KIT Installation Instructions Manual

VENTILATION ADD-ON KIT
INSTALLATION INSTRUCTIONS
PARTS LIST
1. Ventilation Grille Assembly a. Ventilation housing b. Ventilation screen c. Screw backing tabs
3. Ventilation Motor and Vent Cap Assembly a. 250mm Ducting b. Vent cap c. Vent motor assembly d. 250mm to 150mm reducer e. 150mm to 100mm reducer f. Fastener kit vent cap
NOTE: Not all items are shown or are to scale
(1) (1) (1) (6)
(6) (2) (1)
3m (1) (1) (1) (1) (1)
Quanity
1b
2a
1a
1c
2b
3f
3c
3e
3d
3a
3b
OVERVIEW
These instructions are for installing the Solatube® Ventilation Add-On Kit with the Solatube Brighten Up® Series 160 DS (10 in/250 mm Daylighting System). The Solatube® Light Add-On Kit may also be installed in conjunction with the Ventilation Add-On Kit. Refer to the Solatube Brighten Up® Series and the Solatube® Light Add-On Kit instructions to complete the installation.
MARKING LOCATION Step 1: Refer to the Solatube Brighten Up® Series
instructions, Step 1 and Step 2, to mark ceiling and roof location of the Daylighting System.
Step 2: Place Ventilation Housing Template on ceiling surface and orient one of the locator points with the ceiling hole from Step 1. Drill 1/8 in (3mm) hole through the ceiling at the other locator point and repeat Step 1 to establish clearance (Diagram A). Once location has been established, tape template to ceiling. Cut through Template along line and remove ceiling material.
Step 3: Place the small end of the reducer over the neck of the vent cowl and secure with foil tape (Diagram B). Then secure the 150mm Flexiduct to the top of the black reducer ­using foil tape (Diagram C).
VENTILATION HOUSING Step 4: Secure Ventilation Housing with six (6) x 1 5/8 in
(40mm) plasterboard (ceiling) screws and the six (6) screw backing tabs (Diagram D).
Ventilation Duct/Roof Fan Motor Installation
You need to have the 2nd 250 roof ashing installed (around 90cm plus) from the skylight roof ashing, to allow installation
of the vent duct, fan motor and vent cap.
Note: Select ashing as required, not standard with this kit.
Diagram A
Diagram B
Diagram D
Diagram C
Step 5: Select a suitable Fan Motor Assembly location approximately 3 to 4 feet (1 m) from intake hole toward roof or side-wall vent. Fan Motor Assembly can be installed at any angle without affecting performance. The arrow printed on Fan
Motor Assembly shows airow direction. Point the arrow away from ceiling xture intake and toward the roof or side-wall vent
(Diagram E). To secure Fan Motor Assembly, screw four (4) 1 in (25 mm) screws through Mounting Brackets on Fan Motor Assembly into building structure.
Step 6: Install 150mm piece of exi air duct from ventilation
housing to inlet of fan motor (Diagram F). Note: For best vent performance, make air duct run as short as possible with minimum bends.
Step 7: Fit the narrow end of the 150mm x 250mm white plastic reducer over end of vent duct running from the fan motor, and secure with foil tape (Diagram G).
Step 8: Then place 150mm x 250mm reducer at the top
of turret opening in roof ashing, and secure with foil tape
(Diagram H).
IMPORTANT NOTICE
250 Terracotta Flashing/Vented Fit and secure the extension turret ring to the turret of the
ashing before proceeding with Step 8 - above
Vent Vap Installation Step 9: Drill a 5mm diameter hole in each of the 3 legs,
10mm up from the end of leg. Place vent cap over top of the
ashing/fan unit with one leg centred front face of the ashing
turret.
It may be necessary to cut out a small section on the side of vent cap - opposite adjacent the two back legs, to make it
easier when xing screws. Using the three pre-drilled holes as a guide, drill a 3mm pilot hole into turret of the ashing – then
secure vent cap with stainless dome screws (Diagram I).
Diagram F
Diagram G
Diagram H
Diagram I
Diagram E
Loading...