Power Optimiser
For Australia
Module Add-On
P401 / P500 / P505
25
YEAR
WARRANTY
POWER OPTIMISER
PV power optimisation at the module-level
Specically designed to work with SolarEdge
inverters
Up to 25% more energy
Superior efciency (99.5%)
Mitigates all types of modules mismatchloss, from manufacturing tolerance to partial
shading
solaredge.com
Flexible system design for maximum space
utilization
Fast installation with a single bolt
Next generation maintenance with module
level monitoring
Module-level voltage shutdown for installer
and reghter safety

Power Optimiser For Australia
Module Add-On
P401 / P500 / P505
Optimiser Model
(Typical Module Compatibilty)
P401
(60&70 Cell modules)
P500
(for 96-cell
modules)
P505
(for higher current
modules)
INPUT
Rated Input DC Power
Absolute Maximum Input Voltage
(Voc at lowe temperature)
MPPT Operating Range 8 - 60 8 - 80 12.5-83 Vdc
Maximum Short Circuit Current (Isc) 11.75 10.1 14 Adc
Maximum Eciency 99.5 %
Weighted Eciency 98.8 %
Overvoltage Category II
OUTPUT DURING OPERATION (POWER OPTIMISER CONNECTED TO OPERATING SOLAREDGE INVERTER
Maximum Output Current 15 Adc
Maximum Output Voltage 60 60 85 Vdc
OUTPUT DURING STANDBY (POWER OPTIMISER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
Safety Output Voltage per Power Optimiser 1 ± 0.1 Vdc
(1)
400 500 505 W
60 80 83 Vdc
)
)
STANDARD COMPLIANCE
EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety), UL1741
RoHS Ye s
Fire Safety VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Maximum Allowed Syem Voltage 1000 Vdc
Dimensions (W x L x H) 129 x 153 x29.5 129 x 153 x 33.5 129 x 162 x 59 mm
Weight (including cables) 655 750 1064 gr
Input Connector
Input Wire Length 0.16 / 0.9
Output Connector MC4
Output Wire Length 1.2 m
Operating Temperature Range -40 to +85 ˚C
Protection Rating IP68 / NEMA6P
Relative Humidity 0 - 100 %
(2)
MC4
(2)
(4)
(2)
MC4
0.16 m
(1) Rated power of the module at STC will not exceed the optimiser “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed
(2) For other connector types please contact SolarEdge
(3) Dual version for parallel connection of 2 modules; P/N: P485-4RMDMRM. In a case of odd number of PV modules in one ring it is allowed to inall one P485 dual version power optimiser
connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals
(4) Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx
Single Phase
PV System Design Using a Solaredge Inverter
Minimum String Length (Power
Optimisers)
Maximum String Length (Power Optimisers) 25 25 50
Maximum Nominal Power per String
Parallel Strings of Different Lengths or Orientations Ye s
(5) It is not allowed to mix P505 with P401/P500 in one ring
(7) It is allowed to inall up to 13,500W per ring when the maximum power difference between each ring is 2,000W
(6) If the inverters rated AC power ≤ maximum nominal power per ring, then the maximum power per ring will be able to reach up to the inverters maximum input DC power Refer to: https://www.solaredge.
com/sites/default/les/se-single-ring-power-optimizer-application-note-aus.pdf
© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc.
All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2021/V01/ENG AUS. Subject to change without notice.
P401, P500 8 9 16
P505 6 8 14
(5)
HD-WAVE
(6)
(6000
5700
with SE8000H,
SE10000H)
Single Phase
(6)
5250
Three Phase
Residential
(6)
5625
Three Phase
Commercial
(7)
11250
W