solaredge P505, P500, P401 User Manual

Power Optimiser
For Australia Module Add-On
P401 / P500 / P505
25
YEAR
WARRANTY
POWER OPTIMISER
PV power optimisation at the module-level
Specically designed to work with SolarEdge inverters
Up to 25% more energy
Superior efciency (99.5%)
Mitigates all types of modules mismatch­loss, from manufacturing tolerance to partial shading
solaredge.com
Flexible system design for maximum space utilization
Fast installation with a single bolt
Next generation maintenance with module level monitoring
Module-level voltage shutdown for installer and reghter safety
Power Optimiser For Australia
Module Add-On
P401 / P500 / P505
Optimiser Model (Typical Module Compatibilty)
P401
(60&70 Cell modules)
P500
(for 96-cell
modules)
P505
(for higher current
modules)
INPUT
Rated Input DC Power
Absolute Maximum Input Voltage (Voc at lowe󰎯 temperature)
MPPT Operating Range 8 - 60 8 - 80 12.5-83 Vdc
Maximum Short Circuit Current (Isc) 11.75 10.1 14 Adc
Maximum Eciency 99.5 %
Weighted Eciency 98.8 %
Overvoltage Category II
OUTPUT DURING OPERATION (POWER OPTIMISER CONNECTED TO OPERATING SOLAREDGE INVERTER
Maximum Output Current 15 Adc
Maximum Output Voltage 60 60 85 Vdc
OUTPUT DURING STANDBY (POWER OPTIMISER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
Safety Output Voltage per Power Optimiser 1 ± 0.1 Vdc
(1)
400 500 505 W
60 80 83 Vdc
)
)
STANDARD COMPLIANCE
EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety), UL1741
RoHS Ye s
Fire Safety VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Maximum Allowed Sy󰎯em Voltage 1000 Vdc
Dimensions (W x L x H) 129 x 153 x29.5 129 x 153 x 33.5 129 x 162 x 59 mm
Weight (including cables) 655 750 1064 gr
Input Connector
Input Wire Length 0.16 / 0.9
Output Connector MC4
Output Wire Length 1.2 m
Operating Temperature Range -40 to +85 ˚C
Protection Rating IP68 / NEMA6P
Relative Humidity 0 - 100 %
(2)
MC4
(2)
(4)
(2)
MC4
0.16 m
(1) Rated power of the module at STC will not exceed the optimiser “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed (2) For other connector types please contact SolarEdge (3) Dual version for parallel connection of 2 modules; P/N: P485-4RMDMRM. In a case of odd number of PV modules in one 󰎯ring it is allowed to in󰎯all one P485 dual version power optimiser connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals (4) Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx
Single Phase
PV System Design Using a Solaredge Inverter
Minimum String Length (Power Optimisers)
Maximum String Length (Power Optimisers) 25 25 50
Maximum Nominal Power per String
Parallel Strings of Different Lengths or Orientations Ye s
(5) It is not allowed to mix P505 with P401/P500 in one 󰎯ring (7) It is allowed to in󰎯all up to 13,500W per 󰎯ring when the maximum power difference between each 󰎯ring is 2,000W (6) If the inverters rated AC power ≤ maximum nominal power per 󰎯ring, then the maximum power per 󰎯ring will be able to reach up to the inverters maximum input DC power Refer to: https://www.solaredge. com/sites/default/les/se-single-󰎯ring-power-optimizer-application-note-aus.pdf
© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2021/V01/ENG AUS. Subject to change without notice.
P401, P500 8 9 16
P505 6 8 14
(5)
HD-WAVE
(6)
(6000
5700
with SE8000H,
SE10000H)
Single Phase
(6)
5250
Three Phase
Residential
(6)
5625
Three Phase Commercial
(7)
11250
W