
Power Optimizer
For North America
P370 / P400 / P401 / P485 / P505
25
YEAR
WARRANTY
POWER OPTIMIZER
PV power optimization at the module-level
Specically designed to work with SolarEdge
inverters
Up to 25% more energy
Superior efciency (99.5%)
Mitigates all types of module mismatch losses,
from manufacturing tolerance to partial
shading
Flexible system design for maximum space
utilization
solaredge.com
Fast installation with a single bolt
Next generation maintenance with modulelevel monitoring
Meets NEC requirements for arc fault
protection (AFCI) and Photovoltaic Rapid
Shutdown System (PVRSS)
Module-level voltage shutdown for installer
and reghter safety

Power Optimizer
For North America
P370 / P400 / P401 / P485 / P505
Optimizer model
(typical module compatibility)
P370
(for higher-power 60
and 72-cell modules)
P400
(for 72 & 96-
cell modules)
P401
(for high power 60
and 72 cell modules)
P485
(for high-voltage
modules)
P505
(for higher
current modules)
INPUT
Rated Input DC Power
Absolute Maximum Input Voltage
(Voc at lowe temperature)
MPPT Operating Range 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc
Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc
Maximum Eciency 99.5 %
Weighted Eciency 98.8 %
Overvoltage Category II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER
Maximum Output Current 15 Adc
Maximum Output Voltage 60 85 Vdc
(1)
370 400 485 505 W
60 80 60 125
(2)
(2)
83
Vdc
)
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc
STANDARD COMPLIANCE
Photovoltaic Rapid Shutdown Syem NEC 2014, 2017 & 2020 NEC 2014, 2017 & 2020 NEC 2014, 2017 & 2020
EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety), UL1741
Material UL94 V-0 , UV Resiant
RoHS Ye s
INSTALLATION SPECIFICATIONS
Maximum Allowed Syem Voltage 1000 Vdc
Compatible inverters All SolarEdge Single Phase and Three Phase inverters
Dimensions (W x L x H)
Weight (including cables) 655 / 1.4 750 / 1.7 655 / 1.4 845 / 1.9 1064 / 2.3 gr / lb
Input Connector MC4
Input Wire Length 0.16 / 0.52, 0.9 / 2.95
Output Wire Type / Connector Double Insulated / MC4
Output Wire Length 1.2 / 3.9 m / ft
Operating Temperature Range
Protection Rating IP68 / NEMA6P
Relative Humidity 0 - 100 %
(1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed
(2) NEC 2017 requires max input voltage be not more than 80V
(3) For other connector types please contact SolarEdge
(4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one ring, inalling one P485 dual version power optimizer connected
to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals
(5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details
(5)
-40 to +85 / -40 to +185 ˚C / ˚F
129 x 153 x 27.5 / 5.1 x 6
x 1.1
129 x 153 x 33.5 /
(4)
5.1 x 6 x 1.3
(3)
0.16 / 0.52 0.16 / 0.52, 0.9 / 2.95
129 x 153 x 29.5 /5.1 x 6
x 1.16
129 x 153 x 33.5 / 5.1
Single or dual MC4
(4)
(3)(4)
129 x 162 x 59 /
5.1 x 6.4 x 2.3
(3)
MC4
x 6 x 1.3
0.16 / 0.52 0.16 / 0.52 m / ft
mm
/ in
)
PV System Design Using a SolarEdge
Inverter
Minimum String Length
(Power Optimizers)
Maximum String Length (Power Optimizers) 25 25 50
Maximum Nominal Power per String
Parallel Strings of Different Lengths or Orientations Ye s
(6) For detailed ring sizing information refer to: http://www.solaredge.com/sites/default/les/ring_sizing_na.pdf
(7) It is not allowed to mix P485/P505 with P370/P400/P401 in one ring
(8) If the inverters rated AC power ≤ maximum nominal power per ring, then the maximum power per ring will be able to reach up to the inverters maximum input DC power. Refer to: https://www.solaredge.
com/sites/default/les/se-power-optimizer-single-ring-design-application-note.pdf
(9) For 208V grid: it is allowed to inall up to 7,200W per ring when the maximum power difference between each ring is 1,000W
(10) For 277/480V grid: it is allowed to inall up to 15,000W per ring when the maximum power difference between each ring is 2,000W
© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc.
All other trademarks mentioned herein are trademarks of their respective owners. Date: 02/2021/V02/ENG NAM. Subject to change without notice.
(6)(7)
P370, P400, P401 8 10 18
P485, P505 6 8 14
Single Phase
HD-Wave
(8)
(6000 with
5700
SE7600-US - SE11400-US)
Single phase
(8)
5250
Three Phase for
208V grid
(9)
6000
Three Phase for
277/480V grid
(10)
12750
W