SolaHD SVL Series Data Sheet

SVL Essential DIN Rail Series
SVL Series power supplies are perfect for high volume, controlled environment applications where essential features are the only requirement. When space inside an enclosure is at a premium, their small footprint makes these power supplies an excellent alternative to embedded open frame switchers. The DIN rail mounting capability provides quicker
and easier installation while allowing for design exibility.
These power supplies range from 15 to 480 Watts in 5, 12, 24 and 48 Volt combinations.
Applications
• Test and Measure Equipment
• Scanners
• Instrumentation
• Printers Peripheral
• ATM Machines
• Semiconductor Fabrication Equipment
• Vending Machines
Features
• Universal Input
• Protection
- Short Circuit
- Over Voltage
- Overload
- Over Temperature
• Power Factor Correction
• Convection Cooling
• Blinking OCP Diagnostic
• DC OK LED
• DC OK Relay for >120 Watts models
• Two year limited warranty
Power Supplies
E61379
Certifications and Compliances
All Models
- UL 508, CSA C22.2 No. 107.1
- UL 60950-1/CSA C22.2 No. 60950-1, 2nd Edition
- IEC/EN60950-1, 2nd Edition
- Model SVL 1-24-100, SVL 3-5-100, SVL 4-12-100,
• RoHS Compliant
Listed, Ind. Control Equipment, E61379
Recognized Component, ITE, E137632
SVL 2-24-100 were evaluated for NEC Class 2
outputs.
E137632
3
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
1
3
Power Supplies
SVL Specifications <120W
Description
Input Voltage Range
- AC Range
- DC Range
- Frequency
Nominal Current
- Inrush Current max,
Efficiency
Leakage Current
Power Factor Correction
Nominal Voltage
- Tolerance
Voltage Adjustable Range
- Ripple (25 °C)
PARD (25 °C)
Nominal Current
Max. Power
Holdup Time at full load (25 °C)
Rise Time at full load (25 °C)
Start Up at full load (25 °C)
Regulation
Operating Temperature
Relative Humidity
Storage temp
Power Derating
Shock
Vibration
Overvoltage Protection
Overload Protection
Over Temperature Protection
Short Circuit
MTBF
Galvanic Isolation
Emissions
Immunity
H x W x D in (mm)
Unit Weight
Shipping Weight
LED Signals
DC OK Relay Contact
Warranty
1. DC input range is not listed in safety le it is only to conrm product functional performance.
1
2
IEC60068-2-6: sine wave; 10 Hz to 500 Hz at 2 g, 0.35 mm displacement, three axes for 60 min each operational and 5 Hz to 500 Hz at
SVL 3-5-100 SVL 1-24-100 SVL 6-5-100
0.5 A @ 115 Vac
0.3 A @ 230 Vac
35 A @ 115 Vac 65 A @ 230 Vac
79% typ 88% typ 80% typ
5 V 24 V 5 V
5-5.5 V 24-28 V 5-5.5 V
3 A 1.25 A 6 A
15 W 30 W
IEC60068-2-27: half sine wave 10 G, single axis for a duration of 11 ms operational and 50 G three axes for duration
2.09 grms, three axes for 20 min each non-operational
6.3-7.4 V, Latching 30-34.8 V, Latching 6.3-7.4 V, Latching
Hiccup mode, non-latching (auto-recovery when the fault is removed)
>350 khrs (115 Vac/230 Vac @ 25 °C) as per Telcordia SR-332 issue 3 Jan 2011.
I/P to O/P: 3 K Vac; I/P to GND: 1.5 K Vac; O/P to GND: 0.5 K Vac
EN55022 (CISPR22) Class B, EN55011 Class B, EN61000-6-3, EN61000-6-4, EN61000-3-3, EN61204-3, EN61000-3-2 Class A
EN55024, EN61000-6-1, EN61000-6-2 (EN61000-4-2, 3, 4, 5, 6, 8, 11, 12) Level 3, Performance Criteria A
2.95 x 0.82 x 3.52
(75.0 x 21.0 x 89.5)
0.242 lb (110 g) 0.368 lb (167 g)
0.309 lb (140 g) 0.419 lb (190 g)
Catalog Number
Input
85-264 Vac
100–240 Vac
120-375 Vdc
50/60 Hz
0.8 A @ 115 Vac
0.4 A @ 230 Vac
<1 mA @ 240 Vac
Meets EN61000-3-2 Class A
Output
+/-2%
<75 mVp-p
<75 mVp-p
20 ms typ. @ 115 Vac
100 ms typ. @ 230 Vac
<100 ms
<3000 ms @ 115 Vac, <1500 ms @ 230 Vac
<0.5% Line and <1% Load
Environmental Data
-20 °C to +70 °C
5 to 95% RH Non-condensing
-40 °C to +85 °C
See derating tables.
of 11 ms each non-operational
Protections
Hiccup
No component damage, latch mode
Reliability
EMC
General
GREEN light = DC OK , OCP = blinking
No
2 year
0.9 A @ 115 Vac
0.5 A @ 230 Vac
35 A @ 115 Vac 60 A @ 230 Vac
2.95 x 1.18 x 3.52
(75.0 x 30.0 x 89.5)
2
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
SVL Specifications <120W
Description
Input Voltage Range
- AC Range
- DC Range
- Frequency
Nominal Current
- Inrush Current max.
Efficiency
Leakage Current
Power Factor Correction
Nominal Voltage
- Tolerance
Voltage Adjustable Range
- Ripple (25 °C)
PARD (25 °C)
Nominal Current
Max. Power
Holdup Time at full load (25 °C)
Rise Time at full load (25 °C)
Start Up at full load (25 °C)
Regulation
Operating Temperature
Relative Humidity
Storage temp
Power Derating
Shock
Vibration
Overvoltage Protection
Overload Protection
Over Temperature Protection
Short Circuit
MTBF
Galvanic Isolation
Emissions
Immunity
H x W x D in (mm)
Unit Weight
Shipping Weight
LED Signals
DC OK Relay Contact
Warranty
1. DC input range is not listed in safety le it is only to conrm product functional performance.
1
2
SVL 4-12-100 SVL 2-24-100 SVL 4-24-100
1.0 A @ 115 Vac
0.6 A @ 230 Vac
Meets EN61000-3-2 Class A Active PFC >0.9
12 V 24 V
12-15 V 24-28 V
4 A 2.1 A 4 A
48 W 50 W 96 W
20 ms typ. @ 115 Vac 90 ms typ. @ 230 Vac
IEC60068-2-27: half sine wave 10 G, single axis for a duration of 11 ms operational and 50 G three axes for duration
IEC60068-2-6: 10 Hz to 500 Hz at 2 g, 0.35mm displacement, three axes for 60 min each operational and 5 Hz to 500 Hz at
2.09 grms, three axes for 20 min each non-operational
16-18.7 V, Latching 30-34.8 V, Latching
Hiccup mode, non-latching (auto-recovery when the fault is removed)
>350 khrs (115 Vac/230 Vac @ 25 °C) as per Telcordia SR-332 issue 3 Jan 2011.
I/P to O/P: 3 K Vac; I/P to GND: 1.5 K Vac; O/P to GND: 0.5 K Vac
EN55022 (CISPR22) Class B, EN55011 Class B, EN61000-6-3, EN61000-6-4, EN61000-3-3, EN61204-3, EN61000-3-2 Class A
EN55024, EN61000-6-1, EN61000-6-2 (EN61000-4-2, 3, 4, 5, 6, 8, 11, 12) Level 3, Performance Criteria A
2.95 x 1.18 x 3.52
(75.0 x 30.0 x 89.5)
0.390 lb (177 g) 0.698 lb (317 g)
0.478 lb (217 g) 0.816 lb (370 g)
Power Supplies
Catalog Number
Input
85-264 Vac
100–240 Vac
120-375 Vdc
50/60 Hz
1.0 A @ 115 Vac
0.6 A @ 230 Vac
35 A @ 115 Vac 60 A @ 230 Vac
<1 mA @ 240 Vac
Output
+/-2%
<75 mVp-p
<75 mVp-p
<100 ms
<3000 ms @ 115 Vac, <1500 ms @ 230 Vac
<0.5% Line and <1% Load
Environmental Data
-20 °C to +70 °C
5 to 95% RH Non-condensing
-40 °C to +85 °C
See derating tables.
of 11 ms each non-operational
Protections
Current foldforward and then hiccup
No component damage, latch mode
Reliability
EMC
General
GREEN light = DC OK , OCP = blinking
No
2 year
3
1.2 A @ 115 Vac
0.6 A @ 230 Vac
25 ms typ. @ 115 Vac 50 ms typ. @ 230 Vac
2.95 x 1.77 x 3.93
(75.0 x 45.0 x 100.0)
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
3
3
Power Supplies
SVL Specifications >120W
Description
Input Voltage Range
- AC Range
- DC Range
- Frequency
Nominal Current
- Inrush Current max.
Efficiency
Leakage Current
Power Factor Correction
Nominal Voltage
- Tolerance
Voltage Adjustable Range
- Ripple (25 °C)
PARD (25 °C)
Nominal Current
Max. Power
Holdup Time at full load (25 °C)
Rise Time at full load (25 °C)
Start Up at full load (25 °C)
Regulation
Operating Temperature
Relative Humidity
Storage temp
Power Derating
Shock
Vibration
Overvoltage Protection
Overload Protection
Over Temperature Protection
Short Circuit
MTBF
Galvanic Isolation
Emissions
Immunity
H x W x D in (mm)
Unit Weight
Shipping Weight
LED Signals
DC OK Relay Contact
Warranty
1. DC input range is not listed in safety le it is only to conrm product functional performance.
1
2
56-67.2 V, Latching, re-power to recover 28.8-35.2 V, latching, re-power to recover
SVL 2-48-100 SVL 5-24-100 SVL 10-24-100 SVL 20-24-100
2.20 A @ 115 Vac
1.40 A @ 230 Vac
Meets EN61000-3-2 Class A Active PFC >0.95
48V 24V
44-56 V 22-28 V
<120 mVp-p <100 mVp-p
<150 mVp-p <120 mVp-p
2.5 A 5 A 10 A 20 A
120 W 240 W 480 W
IEC60068-2-27: half sine wave 10 G, single axis for a duration of 11 ms operational and 50 G three axes for duration
IEC60068-2-6: sine wave; 10 Hz to 500 Hz at 2 g, 0.35 mm displacement, three axes for 60 min each operational and 5 Hz to 500 Hz at
2.09 grms, three axes for 20 min each non-operational
105- 50% of rated load; constant current at >20 V output and hiccup at <20 V output.
SVL 2-48-100: constant current at >40 V output and hiccup at <40 V output, auto-recovery
No component damage, latch mode,
Hiccup mode, non-latching (auto-recovery when the fault is removed)
>700 khrs (115 Vac & 230 Vac @ 25 °C) as per Telcordia SR-332 issue 3 Jan 2011.
I/P to O/P: 3 K Vac; I/P to GND: 2 K Vac; O/P to GND: 0.5 K Vac
EN55022 (CISPR22) Class B, EN55011 Class B, EN61000-6-3, EN61000-6-4, EN61000-3-3, EN61204-3, EN61000-3-2 Class A
EN55024, EN61000-6-1, EN61000-6-2 (EN61000-4-2, 3, 4, 5, 6, 8, 11, 12) Level 3, Performance Criteria A, SEMI F47 @ 200 Vac
4.84 x 1.57 x 4.63
(123.6 x 40.0 x 117.6)
1.19 lb (540 g) 1.76 lb (800 g) 2.87 lb (1300 g)
1.46 lb (660 g) 2.09 lb (950 g) 3.20 lb (1452 g)
Catalog Number
Input
85-264 Vac
100–240 Vac
120-375 Vdc
50/60 Hz
20 A typ.@ 115 Vac 40 A typ.@ 230 Vac
88% typ
<1 mA @ 240 Vac
Output
+/-2%
10 ms typ.@ 115 Vac 16 ms typ @ 230 Vac
<100 ms
<1000 ms @ 115 Vac & 230 Vac
<0.5% Line and <1% Load
Environmental Data
-20 °C to +70 °C
5 to 95% RH Non-condensing
-40 °C to +85 °C
See derating tables.
of 11 ms each non-operational
Protections
re-power to recover
Reliability
EMC
General
GREEN light = DC OK , OCP = blinking
Yes
2 year
2.8 A @ 115 Vac
1.4 A @ 230 Vac
4.87 x 2.36 x 4.63
(123.6 x 60.0 x 117.6)
5.4 A @ 115 Vac
2.7 A @ 230 Vac
40A typ.@ 115 Vac 80A typ.@ 230 Vac
4.87 x 3.37 x 5.06
(123.6 x 85.5 x 128.5)
4
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
SVL Derating Tables
Power Derating Curve For PSU
Power Supplies
3
110%
100%
90% 80% 70%
60%
50%
40% 30%
20%
Percentange Of Max Load (%)
10%
0%
-20 -10 010
110%
100%
90% 80% 70%
60%
50%
40% 30%
20%
Percentange Of Max Load (%)
10%
0%
-20 -10 010
15 Watt - 96 Watt Models
20 30 40
Ambient Temperature (°C)
230 Vac and 115 Vac
110%
100%
90% 80% 70% 60% 50% 40% 30% 20%
10%
Percentange Of Max Load (%)
0%
70
6050
-20 0
240 Watt Models
20 40 6050 70
Ambient Temperature (°C)
230 Vac
120 Watt and 480 Watt Models 120 Watt - 480 Watt Models
110%
100%
90% 80% 70%
60%
50%
40% 30%
20%
Percentange Of Max Load (%)
10%
0%
20 30 40
Ambient Temperature (°C)
230 Vac 115 Vac
70
6050
85 90 95 100 115 230 264
Input Voltage (Vac)
115 Vac
SVL Series Dimensions
H
Catalog Number
SVL 3-5-100
SVL 1-24-100
D
W
SVL 6-5-100
SVL 4-12-100
SVL 2-24-100
SVL 4-24-100
SVL 2-48-100
SVL 5-24-100
SVL 10-24-100
SVL 20-24-100
2.95 (75.0) 0.82 (21.0) 3.52 (89.5)
2.95 (75.0) 0.82 (21.0) 3.52 (89.5)
2.95 (75.0) 1.18 (30.0) 3.52 (89.5)
2.95 (75.0) 1.18 (30.0) 3.52 (89.5)
2.95 (75.0) 1.18 (30.0) 3.52 (89.5)
2.95 (75.0) 1.77 (45.0) 3.93 (100.0)
4.84 (123.6) 1.57 (40.0) 4.63 (117.6)
4.84 (123.6) 1.57 (40.0) 4.63 (117.6)
4.87 (123.6) 2.36 (60.0) 4.63 (117.6)
4.87 (123.6) 3.37 (85.5) 5.06 (128.5)
Contact Technical Services at (800) 377-4384 with any questions.
Dimensions - inches (mm)
H W D
5
Visit our website at www.solahd.com.
Loading...