The SDN family of DIN Rail power supplies have industry
leading performance with a true industrial grade design
and high quality that meets difficult industrial environmental conditions including high shock, vibration, and wide
temperature ranges over the long life cycle of industrial
equipment.
Features
Industrial grade design.
-10oC to 60oC operation without derating.
Indefinite short circuit, overvoltage and
overtemperature protection.
- Powers high inrush loads without shutdown
or foldback.
- Rugged metal case and DIN connector.
Class 2 rated for DeviceNetTM models.
Narrow width on rail for space critical applications.
Contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Related Products
SDP Series
SFL Series
SCP Series
SCL Series
Applications
Industrial control
Process control
Machine control
DeviceNet
TM
8312
UL 508 Listed
IND. CONT.
EQ.
18 WM, EI91000
UL 1950
E137632
CUL/CSA-C22.2
No. 234-M90
2
EMV and
Low Volt.
Directive
25
2
Power Supplies
SDN Specifications (Single Phase)
Description
Nominal Input Voltage
-Range18-32 VDC85-132/176-264VAC
-FrequencyN/A47 - 63 Hz
Nominal Input Current
-Inrush current max.typ. < 5.1 Atyp. < 25 Atyp. < 15 Atyp. < 30 Atyp. < 85 A
Efficiency (Losses
Nominal Output Voltage
-Tolerance< 1% overall< 2% overall
3
-Ripple
Nominal Output Current
-Peak Power
(calculated at 24 Volt
levels)
-Current Li mit
Holdup Time
Parallel Operation
EMC
-Emissions
-Immunity
Approvals
General
Protection/S afety
Status Indicators
Installation
-Fusing
-Mounting
-C onne ct io ns
-Case
-Free Space
H x W x D (inches/mm)
Weight (lbs/g)
Temperature
War ra n ty
1
Input current ratings are conservatively specified with low input, line conditions, worst case efficiency values and power factor spikes.
Input current at nominal input line settings will be typically half these values.
2
Losses are heat dissipation in watts at full load, nominal input line.
3
Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
4
SDN20-24-100 can replace the SDN20-24-200. The units is the same size as the -200 with both 115 and 230 VAC capability
2
)
via front panel selector switch. -100 units come set at 115 VAC. -200 units are 208/230 only.
26
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
SDN 8-5-24SDN 2.5-24-100SDN 4-24-100SDN 5-24-100SDN 10-24-100SDN 20-24-100
DC 24 V
1
1.5 A. / 2.9 A1.3 A. / 0.7 A2.6 A. / 1.4 A6A / 2.8 A typical12 A/6 A
80% typ (8 W)> 90% typ (6 W)> 90% typ (12 W)> 90% typ (24 W)> 90% typ (48 W)
5 VDC
< 50 mVpp< 20 mVpp
8 A (40 W)2.5 A (60 W)
N/A
Foldback
> 10 ms> 20 ms> 16 ms
SDN 2.5; SDN 5 and SDN 10 may be paralleled by brute force - see the RED options on the proceeding pages. The SDN20 and 30 may
be paralleled by selecting the "P" position of the switch on the bottom of the unit.
EN50082-1,-2 Class B EN55011, EN55022 Radiated and Conducted
EN60950; EN60204; UL508 Listed, cULus; UL1950, cRUus, SDN4 & 2.5 - Class 2 LPS; CE (LVD 73/23 & 93/68/EWG,
EMC 89/336 & 93/68/EWG; Transient Handling VDE 0160/W2. SDN 8-5-24 complies to all of the above;
Approvals pending (SELV < 42 V).
Protected against short-circuit, overload, open-circuit. Overvoltage protection (OVP) for output set @32 V ±10%.
Protection class I (IEC536), degree of protection: IP20 (VDE 0470, IEC 529) Safe low voltage: SELV (acc. EN60950).
Green LED on, when V
Internally fused, however external 10 A slow acting fusing for the input is recommended. (SDN 20 requires a 20A, B-type circuit breaker).
Outputs are capable of providing high currents for short periods of time for inducti ve load startup or switching. Fusing may be required for
wire/loads if 2x Nominal O/P current rating cannot be tolerated.
Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set SDN-PMBRK required).
Input: screw terminals, connector size range: 1.5...6 mm (solid) respectively. 0.5...4 mm (flexible) Output: two connectors per output,
current hand li ng c ap ac ity 30 A ea ch.
Fully enclosed metal housing with fine ventilation grid to keep out small parts (e.g., screws).
25 mm above and below
4.88 x 1.97 x 4.04
Storage: -25 oC...+85 oC operation. 10o-70oC; 0o-60oC full power with operation to 70oC possible with a linear derating to
half power from 60
2x Nom inal Curre nt
< 2 sec.
Co nst ant Curren t
Type with Foldback
OK. See SDN - RED options for DC or Relay Contact.
out
-10 mm in front
(124 x 50 x 103)
1lb (460g)1.5lbs (620g)2.2lbs (1100g)3lbs (1520g)
o
C to 70oC.
Fax-on-Demand #: (877) 888-9329, Document #:
Contact Technical Services at (800) 377-4384 with any questions.
CaseFully enclosed metal housing with fine ventilation grid to keep out small parts (e.g., screws).
Free Space
H x W x D (inche s/mm)
Weight (lbs/g)
Temperature
Warranty
1
Input current ratings are conservatively specified with low input. Line conditions, worst case efficiency values
and power factor spikes. Typical input current at nominal input line settings will be typically half these values.
2
Losses are heat dissipation in watts at full load, nominal input line.
3
Ripple/noise is stated as typical values when measured with a 20 MHz, bandwidth scope and 50 Ohm resistor.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
1
3
SDN 5-24-480SDN 20-24-400SDN 20-24-480SDN 30-24-480SDN 40-24-480
3PH AC380-480 VAC,
Auto Range
3.0 A. / 0.5 A3 x 1.5 A3 x 2.0 A3 x 3.0 A
2
)
> 90% typ (12 W)> 90% typ (48 W)> 90% typ (72 W)> 90% typ (96 W)
5 A20 A30 A40 A
6 A25 A30 A45 A
Constant Current
2x Nominal for 2 sec.
> 10 ms> 11 ms> 11 ms
The SDN20/30 may be passively paralleled by selecti ng the "P" position of the switch on the bottom of the unit. The SDN40 contains
active current balancing. (For Critical Redundant applicati ons, see External Redundant Option Module (SDN-RED) that includes external
diodes and monitori ng circuitry).
EN50081-1, EN50082-2 C lass B EN55011, EN55022 Radiated and Conducted
Protected against short-circuit, overload, open-circuit. Overvoltage protection (OVP) for output set @32 V ±10%.
Protection class I (IEC536), degree of protection: IP20 (VDE 0470, IEC 529) Safe low voltage: SELV (acc. EN60950). Three phase
uni ts have phase loss protection where unit will shutdown when one or two phases are lost. The supplies will operate with one phase
lost if loading is 70% of nominal power.
DC Ok LED: Green LED on, when V
overload conditions [14 V (10 V < V
SDN20 (14 V) and SDN30 (10V); SDN40 has DC OK and Red for Overload; where V
SDN40 only; (Hi gh = 24 V, Low = Signal Ground). Temp Warning Signal: High/Good; Power good High/Good; Remote on/off, Off = Low.
Current Sense (I
See external SDN-RED module for DC OK and Isolation Diode protection on SDN20, 30 and 40.
External 10 A slow acti ng circuit protecti on for the input is recommended. Outputs are capable of providing high currents for shor t
periods of time. Fusing may be required for wire/loads if 2x Nominal O/P current rating cannot be tolerated.
Simple snap-on system for DIN Rail TS35/7.5 or TS35/15 or chassis-mounted (optional screw mounting set
SDN-PMBRK required).
Input: screw terminals, connector size range : 1.5...6 mm (so lid) res pecti vely. 0 .5...4 mm (flexible ) Output: two connectors per output,
current handling capacity 30 A each (40 A on the SDN40).
measure, 1 V per 10 A with measure resistor > 100 k Ohm resp. 10 mA per 10A I
out
25 mm above and below
-15 mm in front
o
C...+85 oC Operation. _10o-60oC full power with operation to 70oC possible with a linear derating
o
3PH AC380 V3PH AC480 V
C to 70oC.
Fax-on-Demand #: (877) 888-9329, Document #:
Contact Technical Services at (800) 377-4384 with any questions.
Catalog Number
Inpu t
Output
Constant Current
until Hiccup off at V
2x Nominal for 2 sec.
OK or V
out
< V
set nominal - 2 Volts);.and flashing re d for short ci rcuit condi tions (V
out
out
4.88 x 8.94 x 4.04
(124 x 227 x 103)
24 - 28 VDC Adj.
< 20 mVpp< 50 mVpp
Constant Current
<14 V,
out
> V
set nominal - 2 Volts; Overload LED: Indicator LED for Overload is red for
out
out
Insta llatio n
3 years
unti l Hi cc up o ff
at V
out
2x Nominal for 2 sec.
= <V
out
out
70 mm above and below
25 mm left and right
-15 mm in front
4.88 x 9.72 x 4.45
(125 x 247 x 113)
8312
3PH AC380-480 VAC,
Auto Range
<10 V,
nomi nal - 2 Volt s.
with meas. Resistor < 100 Ohm.
out
Constant Current
2x Nominal for 2 sec.
<=14V (10V);
out
4.92 x 11.10 x 4.45
(125 x 282 x 118)
2
27
2
Power Supplies
SDN Series Dimensions
Catalog
Number
SDN 2.5-24-100 (RED)4.88 (124)1.97 (50)4.04 (103)
SDN 4-24-1004.88 (124)2.91 (74)4.04 (103)
SDN 5-24-100 (RED)4.88 (124)2.91 (74)4.04 (103)
SDN 8-5-244.88 (124)1.97 (50)4.04 (103)
Catalog
Number
SDN 10-24-100 (RED)4.88 (124)5.39 (137)4.04 (103)
SDN 20-24-100; -200,
-400; -480
SDN 30-24-4804.88 (124)9.72 (247)4.45 (113)
SDN 40-24-4804.92 (125)11.10 (282)4.45 (113)
Fax-on-Demand #: (877) 888-9329, Document #:
28
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Contact Technical Services at (800) 377-4384 with any questions.
4.88 (124)8.94 (227)4.04 (103)
Dimensions - inches (mm)
HWD
Dimensions - inches (mm)
HW D
8312
Power Supplies
SDN Series Mounting
DIN Rail Mounting
Snap on the DIN Rail:
1. Tilt unit slightly backwards
2. Put it onto the DIN Rail
3. Push downwards until stopped
4. Push at the lower front edge to lock
5. Shake the unit slightly to ensure that the retainer
has locked
Alternative Screwing-on: Using the optional SDN-PMBRK
accessory, the unit can also be screwed onto plane
surfaces (without DIN Rail).
Detachment from DIN Rail:
Chassis Mounting
Instead of snapping a Sola SDN
Series Unit on the DIN Rail, you
can also screw it on by means
of the screw mounting set
SDN-PMBRK.
This set consists of two
aluminum profiles, which
replace the existing two profiles
at the back of the unit.
Notes:
You need one SDN-PMBRK per unit.
In addition, two screws are required per SDN-PMBRK
(e.g. M5 x 12), which are not included with the set.
Exchanging the
Profiles
a. At the unit:
1. Remove the
screw from the
profile.
2. Pull the profile
outwards to
remove.
Fax-on-Demand #: (877) 888-9329, Document #:
Contact Technical Services at (800) 377-4384 with any questions.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Press button downwards (to unlock) and remove the unit
from the DIN Rail.
Dimensions
b. Push the
SDN-PMBRK
profile into the
groove as far as
possible. Secure
with screw.
Note the orientation:
The profile fits into the groove only as shown here.
8312
2
29
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.