SolaHD Product Manual: Solatron Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA, A272-094 Manuals & Guides

Three-Phase Power Conditioner
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
CONTENTS
Important Safety Instructions � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 1
Receiving and Unpacking � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2
Moving and Lifting � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �2
Storage � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �2
Installation � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �3
Mechanical Considerations � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3 Electrical Considerations � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 To Maintain UL1012 Listing � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5 Lug Size Tables � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5
To Install the Solatron™ Unit � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
Startup � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
Normal Operation � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
Automatic Internal Bypass � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 8
Circuit Breaker Operation � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
Surge Suppression � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �9
Alarms � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
Remote Alarm Relay Dry Contacts� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
Status Indicator Lights � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
Maintenance � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
Maintenance Log � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 11
Specifications � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 13
Technical Support � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 14
Warranty � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 14
FIGURES
Figure 1: Component Layout � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3 Figure 2: Overview � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 Figure 3: Status Indicators � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Important Safety Instructions
The Solatron™ unit and related equipment must be installed, operated, and maintained in accordance with this manual� After complying with all of the information in this manual, it should be saved for future reference�
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
Only properly qualied and trained personnel should be permitted to install, service, and operate
this equipment� Follow all safe electrical work practices� Use all applicable personal protective equipment (PPE)�
The unit is intended to be installed where it is not accessible to the general public� Access to this
equipment must be limited to properly qualied and trained personnel.
Dangerous and potentially lethal voltages are present inside the enclosure of the unit; the hazard of
electric shock, arc ash, and explosion are present.
Under no circumstances should anyone be permitted to operate or energize the unit without all covers
in place, doors closed, and all safeguards in place�
Under no circumstances should anyone be permitted to reach into or perform any action within the
enclosure for maintenance, decommissioning, or other purposes without properly de-energizing and grounding the unit� The transformer coils must be discharged of any potential static charge�
The unit must be installed in accordance with all applicable federal, state, and local codes�
The unit enclosure must be properly grounded using the provided ground connections�
The unit must be installed a safe distance from any combustible material unless separated and shielded
by appropriate re resistance and heat dissipative barriers in accordance with the National Electrical Code™ (NEC™) and all applicable local codes.
The unit must only be installed in locations suitable for the level of protection afforded by the
enclosure type�
No claim is made that these instructions cover all possible details or variations in unit manufacture or
address all possible contingencies that might be encountered during the installation, operation, or maintenance of the unit�
All questions, concerns, informational needs, or problems that arise regarding receiving, unpacking,
moving, lifting, storing, installing, operating, or maintaining the unit which are not sufciently
addressed herein should be referred to SolaHD�
Page: 1
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Receiving and Unpacking
Prior to removing any shipping or packing material, the unit must be immediately inspected upon receipt for any indication of damage sustained during shipping� During unpacking, inspect the inside and outside of the unit for any dents, scrapes, bent or loose parts, water entry, moisture, or any other signs of damage� If there is any reason to believe that the unit has been damaged:
Note the damage on the shipping documentation and notify the carrier.
Document and photograph any damage found�
Contact the shipping company to le a claim if necessary or SolaHD Customer Service.
Moving and Lifting
The Solatron™ unit must be lifted by the base only using a pallet jack or forklift�
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
The center of gravity may not be in the center of the unit�
Use appropriate procedures for handling unbalanced loads�
Do not lift the Solatron™ from the top�
Ensure that the capacity of the lifting equipment is appropriately sized for lifting and moving
the Solatron™�
Contact SolaHD Technical Support if there are any questions or concerns regarding moving or lifting
the unit�
Storage
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
Prior to installation, the Solatron™ must be stored in a location which prohibits the entry of liquid or
moisture into the enclosure�
Condensation must not be allowed to form on the internal components�
Contact SolaHD Technical Support if there are any questions or concerns regarding storage�
Page: 2
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Installation
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
The Solatron™ unit must be installed in an area appropriate for industrial electrical equipment, which includes but is not limited to the following characteristics:
Concrete or other non-combustible, non-ammable oor adequate to support the weight of the unit.
Adequate ventilation�
Free from combustible or ammable materials, liquids, gases, or dust.
Secure from unauthorized access by the general public�
Consistent with the NEMA duty rating of the enclosure (NEMA 1).
Contact SolaHD Technical Support if there are questions or concerns regarding installation�
Mechanical Considerations
Cable entry and exit must be made through the sides or top of the enclosure. Cable entry and exit
penetrations must be made by the end user� Debris from creating cable penetrations must not be allowed on any component within the enclosure� The input and output connection locations and phase sequence are shown in Figure 1
The unit must be installed with the clearances shown in Figure 2� Only the top, front, and rear enclosure panels are removable� The front panel can only be removed with the
input circuit breaker handle in the OFF (OPEN) position.
Remote Alarm
Contacts
Output
Input Circuit
Breaker
Auxiliary Circuit
Breakers
(CB2, CB3)
Distribution Blocks
Control Board
Figure 1: Component Layout
Front View
Page: 3
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
6"
36"
36"
Status Indicator
Lights
See Detail A
12"
Figure 2: Overview
Mounting Holes
3/8" Clearance
Over-temp
Normal
Bypass
Detail A: Status Display Lights
25�5"
(4X)
(Front Panel)
25�25"
Figure 3: Status Indicators
Page: 4
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Electrical Considerations
The nominal input voltage applied to the Solatron™ unit shall be as listed on the unit nameplate� The nominal
operating frequency must match the nameplate frequency. The maximum continuous load must not exceed
the kVA nameplate rating� The unit must be grounded using the provided ground lugs�
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
The unit must be installed in a location appropriate for industrial electrical equipment, which includes but is not limited to the following characteristics:
Compliance with IEEE 519�
The input voltage waveform shall maintain 5% or less THD. If the THD percentage exceeds this value,
the unit’s performance may be adversely affected�
To Maintain UL1012 Listing
Each AC output power circuit shall be provided with overcurrent protection for all ungrounded conductors� The voltage rating of the overcurrent protection shall not be less than the rating of the circuit which with which it is used� The overcurrent protection device shall be a circuit breaker or a fuse evaluated
for use as branch circuit protection. The rating of the overcurrent protection device must meet NEC Article
240 requirements� The output overcurrent protection devices are not included with the unit and must be provided by the end
user or purchaser� Failure to install the output overcurrent protection devices voids the UL1012 listing for the unit�
Lug Size Tables
Input Circuit Breaker Lug Sizes (Copper wire only)
208V 240V 480V 600V
Cable
Range
20kVA #14-1/0 7Nm or 61.95in-lb. #14-1/0 7Nm or 61.95in-lb. #14-1/0 7Nm or 61.95in-lb. #14-1/0 7Nm or 61.95in-lb.
30kVA #14-1/0 7Nm or 61.95in-lb. #14-1/0 7Nm or 61.95in-lb. #14-1/0 7Nm or 61.95in-lb. #14-1/0 7Nm or 61.95in-lb.
50kVA #10-250mcm 14Nm or 123.91in-lb. #10-250mcm 14Nm or 123.91in-lb. #14-1/0 7Nm or 61.95in-lb. #14-1/0 7Nm or 61.95in-lb.
75kVA (2) 3/0-250mcm 18Nm or 159.31in-lb. #10-250mcm 14Nm or 123.91in-lb. #14-1/0 7Nm or 61.95in-lb. #14-1/0 7Nm or 61.95in-lb.
Cable
Range
20kVA #14-2/0
30kVA #14-2/0
50kVA #14-2/0
75kVA #4-500mcm 56.49Nm or 500in-lb. #4-500mcm 56.49Nm or 500in-lb. #14-2/0
Torque
208V 240V 480V 600V
Torque
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
Cable
Range
Output Distribution Block Sizes (Copper wire only)
Cable
Range
#14-2/0
#14-2/0
#14-2/0
Torque
Torque
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
Cable
Range
Cable
Range
#14-8: 5.6Nm or 50in-lb.
#14-2/0
#6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb.
#14-2/0
#6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb.
#14-2/0
#6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
Torque
Torque
Cable
Range
Cable
Range
#14-2/0
#14-2/0
#14-2/0
#14-2/0
Torque
Torque
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
#14-8: 5.6Nm or 50in-lb. #6-2/0: 13.56Nm or 120in-lb.
Page: 5
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
To Install the Solatron™ Unit
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
The following instructions must be followed� Contact SolaHD Technical Support with any questions
or concerns�
1� Ensure that all electrical circuits are properly de-energized and locked out� 2� Locate and access the input and output terminal blocks or lugs�
3� Ensure that cable entry points comply with the appropriate NEMA rating of the enclosure (NEMA 1). Cable
entry points should not be made through removable or panels�
4� Ensure that the enclosure and internal components are not damaged when installing source and load
cabling�
5� Route and restrain the source and load cabling within the enclosure such that it is not in contact with any
components, surface, or sharp corners�
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
Note that all source and load wiring must be installed in accordance with all applicable federal, state, and
local codes�
6� If required, install appropriately rated remote alarm cabling� Refer to the Alarms section for details and
contact ratings�
7� After installation of the source and load wiring, inspect all wiring and internal components for any sign
of damage� Ensure that all connections are tight and wires are secure� Report any signs of damage to components, connectors, or wiring insulation to SolaHD Technical Support prior to energizing the unit�
8� Ensure that the internal auxiliary circuit breakers (CB2 and CB3) are ON (CLOSED). 9� Replace all removable panels which were opened during installation�
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
Ensure that all retaining bolts are reinstalled�
Page: 6
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Startup
When powering the Solatron™ unit for the rst time, please follow these instructions to ensure normal operation. Note that the unit has been fully tested and calibrated and requires no user adjustments during
startup or during normal operation� If there are any questions or concerns, please contact SolaHD Technical
Support immediately. If any of the checks during startup are not satisfactory, do not continue to the next step,
and refer to the Troubleshooting section or contact SolaHD Technical Support�
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
Ensure that all installation requirements have been met�
All eld installed wiring must be complete and secure and the unit enclosure must be fully closed
and secured
1� Ensure that the input breaker is OFF (OPEN).
2� Turn ON the upstream source to apply voltage to the Solatron™.
3� Turn the input circuit breaker handle to the ON (CLOSED) position. This energizes the control
circuits and the transformers. After several seconds, the “Normal” light is illuminated indicating normal operation. The “Bypass” and “Overtemp” lights are not illuminated indicating that there are no alarm
conditions�
The Solatron™ is now in normal operation mode and is supplying regulated voltage to the load�
Normal Operation
The Solatron™ is considered to be in normal operation mode when the load is supplied with regulated voltage� The unit is in normal operation mode when the following conditions are met:
The input circuit breaker is ON (CLOSED).
The “Normal” status indicator light is illuminated.
If one or more of the normal conditions are not met, the load may not be supplied with power, or the power supplied to the load may be unregulated�
While in normal operation, the Solatron™ automatically regulates the output voltage to within the output voltage regulation range� The unit selects discrete transformer taps to regulate the output voltage�
Each phase of the Solatron™ is regulated independently to achieve optimum phase balance within the regulation range�
When the unit changes taps, it is not unusual to see a change in output voltage equal to approximately the
total output regulation range� The output regulation range is +/-3%, so the output voltage may change up to
6% during a tap change. The resulting output voltage remains within the output regulation range.
Page: 7
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Automatic Internal Bypass
The unit has an automatic internal bypass mode included with the objective of protecting the switching semiconductors in the event of failure modes which include but are not limited to:
Semiconductor malfunction
Severe over-currents
Control board malfunction
Power supply malfunction
The unit is in automatic internal bypass mode if either or both of the internal auxiliary circuit breakers (CB2 or CB3) are tripped. In most cases, the power to the load is maintained, but the output voltage is not regulated.
The unit is in automatic internal bypass mode if all of the following conditions are met:
The input circuit breaker is ON (CLOSED)
The “Bypass” status indicator light is illuminated
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
Note that while the automatic internal bypass mode protects the Solatron™ unit and maintains power
to the load, it does not cover all possible contingencies or failure modes�
The output terminals of the unit remain energized when in automatic internal bypass mode�
To return the Solatron™ unit from automatic internal bypass mode to normal operation mode:
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
The unit must be de-energized with the input breaker OFF (OPEN) before proceeding.
Step 1 – Verify that there are no exposed voltages in the electronics compartment.
Step 2 – Determine which auxiliary circuit breaker(s) have tripped.
Step 3 – Reset each tripped breaker�
Step 4 – Once all auxiliary circuit breakers are ON (CLOSED), replace all access panels and close all access
doors, and follow the instructions for returning the unit to normal operation (See Startup Section)�
Page: 8
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Circuit Breaker Operation
The input circuit breaker is mechanically operated by a handle on the front panel� To reset the input circuit
breaker, it must be turned OFF (OPEN) before it may be turned ON (CLOSED).
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
Do not operate the input breaker by any operating mechanisms other than those on the front panel
of the Solatron™�
Surge Suppression
The Solatron™ contains a transient voltage surge suppression device (SPD) unit which is wired to the input circuit breaker load terminals�
Alarms
Remote Alarm Relay Dry Contacts
The Solatron™ unit provides dry relay contacts for remotely monitoring the operating condition. Note that the dry relay contacts must be eld-wired, and no wire or cable is provided to make such connections.
The remote alarm contacts are one set of dry normally closed Form B contacts from a pilot relay available at DIN terminal blocks labeled “Remote Alarm”. During normal operation, the relay is energized. The relay is
de-energized for conditions where the unit may require attention which includes:
Automatic Internal Bypass mode (“Bypass” light is illuminated).
High temperate (“Overtemp” light is illuminated).
Input circuit breaker is OFF (OPEN).
Loss of utility power�
The unit is NOT in normal operation
Contact Ratings
Max� Switching Voltage 220VDC, 250VAC Rated Current 2A
Switching Power 60W, 62.5VA Min� Switching Voltage 100uV
30VDC, 2A, 60W (N.O. Only)
UL Contact Ratings
110VDC, 0�3A, 33W
220VDC, 0.27A, 60W 125VAC, 0.5A, 62.5W 250VAC, 0.25A, 62.5W
Page: 9
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Status Indicator Lights
The Solatron™ unit is equipped with three status indicator lights: “Normal”, “Overtemp”, and “Bypass”.
The function of the “Normal” light is to indicate that the unit is in normal operation mode. The “Overtemp” light is an indication that the transformer coils may be overheating. If the “Overtemp” light
is illuminated, the unit requires immediate attention� The unit may require cleaning, may have been overloaded, or may be in an environment with a high ambient temperature� Refer to the troubleshooting section for more information�
The “Bypass” light is an indication that the unit is in automatic internal bypass mode. If the “Bypass” light is illuminated, one or both of the internal auxiliary circuit breakers (CB2 and CB3) may need to be reset. Refer to
the troubleshooting section for more information�
Note that both the “Overtemp” and “Bypass” indicator lights activate the remote alarm contacts. If either of the “Overtemp” or “Bypass” lights are illuminated, the unit is not in normal operation, and the “Normal” light
is not illuminated�
Maintenance
The following items should be addressed at least annually as part of a responsible maintenance routine� If there are any questions regarding the functionality of the unit during any maintenance procedures, please contact SolaHD Technical Support�
The included log should be used to log and record maintenance activities�
General Condition
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
The Solatron™ unit must be completely de-energized, including power on the line side of the input
circuit breaker and any remote alarm contact power�
Failure to observe maintenance may degrade unit performance or cause load power interruption�
The entirety of the enclosure should be thoroughly examined for any signs of damage, moisture, or liquids.
All wires and cables should be inspected for signs of damaged insulation or overheating� SolaHD Technical Support should be contacted if any of these signs are present� The enclosure should be free from dust and debris� The unit should be cleaned in accordance with good cleaning practices for industrial electronic equipment�
Page: 10
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Maintenance Log
Installation Date: ________________ Model #: _______________________ Serial #: ______________
Inspection/
Maintenance Date
Personnel
Inspections Performed/
Actions Taken
Troubleshooting
!
WARNING
Failure to follow all instructions herein will cause death, severe injury, or significant equipment damage, and void the unit warranty�
Refer to the Important Safety Information section prior to troubleshooting�
The Solatron™ unit must be completely de-energized and locked out prior to troubleshooting�
In the event of alarm conditions or unexpected operation, please refer to the Troubleshooting Table on the next page as a guide to return Solatron™ unit to normal operation. Note that while many conditions are
described, no claim is made that all possible contingencies are covered� If the Troubleshooting Table is unclear, the condition is not listed, or the troubleshooting action does not remedy the condition, please contact SolaHD Technical Support: 1-800-377-4384 Option #2 or email: solahd�technicalservices@emerson�com�
Page: 11
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Troubleshooting Table
Condition Possible Causes Troubleshooting Action
The external ambient temperature exceeds the temperature rating
of the unit
The “Overtemp” indicator light is illuminated
The unit may have been overloaded
An auxiliary circuit breaker may have TRIPPED
One or more semiconductor devices may have failed
The “Bypass” indicator light is illuminated
The control board may have failed
The unit may have been overloaded
The input circuit breaker is TRIPPED The unit may have been overloaded
Take measures to reduce the ambient temperature or prevent
excessive heating
Conrm that the load does not exceed the nameplate rating of
the unit
Follow the steps in the automatic internal bypass section to return the unit to normal operation� If the unit continually enters internal automatic bypass mode, please contact SolaHD Technical Support�
Conrm that the load does not exceed the nameplate rating of
the unit
Conrm that the load does not exceed the nameplate rating
of the unit� Refer to the Circuit
Breaker Operation section for
resetting the circuit breaker�
The remote alarm contacts are closed
Page: 12
The unit may be in an alarm condition or de-energized
Re-energize the unit or refer to the status indicator lights on the front of the unit�
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
Specifications
Application
Model Number 63TXY3ZZ:
Nominal Input Voltage X = A (208V), B (240V), C (480V), D (600V)
Nominal Output Voltage Y = A (208V), B (240V), C (480V), D (600V)
Power Rating / Size ZZ = 20, 30, 50, or 75kVA
Phases - Frequency 3 phase, 60Hz nominal Input Voltage Range +10% to -25% of nominal input voltage Output Voltage Regulation +/-3% of nominal output voltage Connections 3 Wire plus ground (Delta) input, 4 Wire plus ground (Wye) output
Operating Characteristics
Regulation Variation None - regulation constant for 0 to 100% load Overload Capacity 1000% for 1 second, 500% for 5 seconds, 200% for 1 minute - 1000% fault clearing
Minimum Load No minimum load or part load limitations
Load Power Factor No limitations, compatible with all load types
Tap Switching No load current interruption on switching regardless of load or power factor Zero Crossing Sensitivity Tap switching not dependent on determining load current zero crossing
Harmonic Distortion No distortion added regardless of load or power factor Response Time 1 cycle typical regardless of load or load power factor
Efficiency 96% Typical EMI <0�2 gauss at a distance of 3 feet Insulation Resistance 100 megohms from winding to core measured at 500VDC Operating Frequency ±3% of nominal frequency
Noise/Surge Suppression & Short Circuit Protection
Noise Attenuation 150 dB at 100kHz common mode; 65 dB at 100 kHz normal mode
Surge Suppression Included, complies with ANSI/IEEE C26.41 Input Circuit Breaker Included, standard
Automatic Bypass Internal auxiliary circuit breakers; No load interruption on activation
Construction
Technology Electronically-controlled tap switching with series transformer
Switching Semiconductors Non-full power semiconductors - individual SCRs do not carry full unit current Controls Microprocessor-based control, RMS based measurements
Cooling Natural Convection Transformer Isolation: Delta-Wye
Enclosure NEMA 1
Environmental Requirements & Conditions
Audible Sound Level Meets or exceeds NEMA standards Temperature - Humidity Ambient 32 to 104°F (0 to 40°C) - Relative humidity 0-95% non-condensing Operating Altitude 0 to 10,000 ft� (3000m)
Page: 13
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
The information in this manual is provided as a guide for installation, operation, and maintenance� It does not
affect or exceed our obligations under the Terms and Conditions of Sale�
Note that unit specications are subject to change without notice.
Technical Support
Website: www�solahd�com Technical Support E-Mail: solahd�technicalservices@emerson�com Toll-Free: (800) 377-4384
USA: (847) 268-6651
Warranty
Please see the “Terms & Conditions of Sale” document within the product packaging.
While every precaution has been taken to ensure accuracy and completeness in this manual, Appleton Grp LLC d/b/a Appleton Group assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions�
Page: 14
Solatron™: Three-Phase Voltage Regulator — 20, 30, 50, 75 kVA
A272-094 Rev. 7 06/2019
The Emer son logo is a trademark an d service mar k of Emerson Ele ctric Co� Appleton Grp LLC d/b/a Appleton Group� SolaHD is a registered trademark of A ppleton Grp LLC � All othe r marks are the proper ty of their respecti ve owners� © 2019 Emers on Electric Co� All rights reserved�
United States (Headquarters)
Appleton Grp LLC 9377 W� Higgins Road
Rosemont, IL 60018
Unite d States
T +1 8 00 621 1506
Australia Sales Office
Baysw ater, V ictoria T +61 3 9721 0348
Korea Sal es Offic e
Seoul T +82 2 3483 1555
Europe
ATX SAS Espace In dustriel Nord
35, rue André Durouchez, CS 980 17
80084 Amiens Cede x 2
France T +33 3 2254 1390
China Sa les Offic e
Shanghai
T +86 21 3338 70 00
Canada
EGS Electrical Group Canada Ltd� 99 Unio n Street
Elmira ON , N3B 3L7
Canada
T +1 888 765 2226
Middle East Sales Office
Dammam, Saudi Arabia
T +966 13 510 3702
Asia Pac ific
EGS Priv ate Ltd�
Block 40 08, Ang Mo Kio
Ave 10,
#04 -16 TechPlace 1, Singapore 569625 T +65 6556 1100
Chile Sa les Offi ce
Las Condes
T +56 2928 4819
Latin America
EGS Comercializadora
Mexico S de RL de CV Calle 10 N°145 Piso 3
Col� San P edro de los Pin os Del� Álvaro Obregon
Ciudad de Mé xico. 01180
T +52 55 5809 5049
India Sales Office
Chennai T +91 44 3919 7300