GLX250-CF Cover Top Fan Kit
Designed for the following power supplies: GL250 Series and GL350 Series
What’s Included
• One cover with top fan
• Four M3 x 6mm countersunk screws
Recommended Assembly
1. Remove M3 x 6mm countersunk screws (4) and original cover.
2. Attach fan wires to SK4 or SK7 output connector for GL250 Series, SK5 or SK6
output connector for GLS350 Series and SK6 output connector for GLQ350 Series.
See Figures 1-3.
3. Place cover over power supply and align with base countersink holes.
4. Secure cover to base using the supplied M3 x 6mm countersunk screws (4).
Output Adj.
SK7
SK4
SK3
SK5
Figure 1: Fan connection for GL250 Series Figure 2: Fan connection for GLS350 Series
Output Adj.
SK4
SK5
SK6
SK3
Overall Dimensions
3.15 [80.0]
GL250 Series: 3.00 [76.2]
GLS350 Series: 3.64 [92.5]
GLQ350 Series: 3.50 [88.9]
2.17 [55.0]
-CF option
3.68 [93.6]
9.00 [228.6]
Figure 4: Mechanical Drawing—All Models
Notes
• All dimensions are in inches [mm].
• Ensure that the relevant safety standards (e.g. EN60950-1) are complied with, in
respect to creepage and clearance distances, and distances through insulation.
Technical Support
U.S.: (800) 377-4384 • International: (847) 268-6000
E-mail: tech@solahd.com • Web site: www.solahd.com
Output Adj.
SK6
SK4
SK3
SK5
Figure 3: Fan connection for GLQ350 Series
While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Ofce. All other product or service names are the property of their registered owners. ©2009 EGS Electrical Group, LLC. All rights reserved. Specications subject to change without notice.
P/N: A272-217 Rev 0 09/10/09 Ref: LPX250-CF