Softena SOF-CS, SOF-BBS Technical Manual

Page 1
© 2017 erie water treatment TM-EN-SOF-CS_BBS-Rev2017.03
Technical Manual
WATER SOFTENER
Models:
Page 2
TABLE OF CONTENT
Page 2
Table of content ....................................................................................................................... Page 2
Warning & Safety instructions ................................................................................................. Page 3
Operating conditions & Requirements .................................................................................... Page 4
Installation ............................................................................................................................... Page 5
Commissioning ......................................................................................................................... Page 6
Electronic control panel ........................................................................................................... Page 7
Maintenance ............................................................................................................................ Page 11
Hydraulic flow diagrams - Eco .................................................................................................. Page 13
Hydraulic flow diagrams - Eco+ ................................................................................................ Page 14
Troubleshooting ....................................................................................................................... Page 15
Electrical wiring diagrams ........................................................................................................ Page 17
Default configuration parameter settings - SOF-CS ................................................................. Page 18
Default configuration parameter settings - SOF-BBS .............................................................. Page 19
Exploded view - SOF-CS - System ............................................................................................ Page 20
Exploded view - SOF-CS - Cover assembly ............................................................................... Page 22
Exploded view - SOF-BBS - System .......................................................................................... Page 24
Exploded view - Valve body assembly - Eco ............................................................................ Page 26
Exploded view - Valve body assembly - Eco+ ........................................................................... Page 28
Exploded view - SOF-CS - Valve head assembly ....................................................................... Page 30
Exploded view - SOF-BBS - Valve head & timer assembly ....................................................... Page 31
Technical data - SOF-CS-Eco ..................................................................................................... Page 32
Technical data - SOF-CS-Eco+ ................................................................................................... Page 33
Technical data - SOF-BBS-Eco .................................................................................................. Page 34
Technical data - SOF-BBS-Eco+ ................................................................................................. Page 35
Page 3
WARNING & SAFETY INSTRUCTIONS
Page 3
Before you begin the installation of the appliance, we advise you read
and carefully follow the instructions contained in this manual. It contains important information about safety, installation, use and maintenance of the product. The actual system that you have received, may differ from the pictures/illustrations/descriptions in this Technical Manual.
Failure to follow the instructions could cause personal injury or damage
to the appliance or property. Only when installed, commissioned and serviced correctly, the appliance will offer you many years of trouble-free operation.
The appliance is intended to 'soften' the water, meaning it will remove
hardness minerals; it will not necessarily remove other contaminants present in the water. The appliance will not purify polluted water or make it safe to drink!
Installation of the appliance should only be undertaken by a competent
person, aware of the local codes in force. All plumbing and electrical connections must be done in accordance with local codes.
Before setting up the appliance, make sure to check it for any externally
visible damage; do not install or use when damaged.
Use a hand truck to transport the appliance. To prevent accident or
injury, do not hoist the appliance over your shoulder. Do not lay the appliance on its side.
Keep this Technical Manual in a safe place and ensure that new users are
familiar with the content.
The appliance is designed and manufactured in accordance with current
safety requirements and regulations. Incorrect repairs can result in unforeseen danger for the user, for which the manufacturer cannot be held responsible. Therefore repairs should only be undertaken by a competent technician, familiar and trained for this product.
In respect of the environment, the appliance should be disposed of in
accordance with Waste Electrical and Electronic Equipment requirements. Refer to national/local laws and codes for correct recycling of this appliance.
Page 4
OPERATING CONDITIONS & REQUIREMENTS
Page 4
OPERATING PRESSURE MIN-MAX: 1,4-8,3 bar / 20-120 psi
this appliance is configured to perform optimally at an
operating pressure of 3 bar (45 psi) ±½ bar (7 psi); in case of a lower or higher operating pressure the performance may be affected negatively!
check water pressure regularly; it may fluctuate severely
depending on the time of day, the day of the week or even the season of the year.
take into account that night time water pressure may be
considerably higher than day time water pressure.
install a pressure reducer ahead of the appliance if necessary. install a pressure booster, if it is likely that water pressure may
drop below the minimum.
OPERATING TEMPERATURE MIN-MAX: 2-48 °C / 35-120 °F
do not install the appliance in an environment where high
ambient temperatures (e.g. unvented boiler house) or freezing temperatures can occur.
the appliance cannot be exposed to outdoor elements, such as
direct sunlight or atmospheric precipitation.
do not install the appliance too close to a water heater; keep at
least 3 m (10 ft) of piping between the outlet of the appliance and the inlet of the water heater; water heaters can sometimes transmit heat back down the cold pipe into the appliance; always install a check valve at the outlet of the appliance.
ELECTRICAL CONNECTION:
the appliance only works on 24 VAC; always use it in
combination with the supplied transformer.
make sure to plug the transformer into a power outlet, which is
installed in a dry location, with the proper rating and over­current protection.
Page 5
INSTALLATION
Page 5
PREPARATION BRINE CABINET
(only for SOF-CS-)
Picture 1&11.a
To facilitate the installation, you may want to remove the salt lid and main cover from the brine cabinet.
PLACEMENT BRINE CABINET
(only for SOF-BBS-)
This 2-tank system consists of a pressure tank with control valve and a separate brine cabinet. Place both items at the desired installation location, no more than 1 meter apart.
INLET & OUTLET
In case of high concentration of impurities in the inlet
water, we recommend the installation of a sediment filter, ahead of the appliance.
We strongly recommend the use of flexible hoses to
connect the appliance to the water distribution system; use hoses with a large diameter in order to limit the pressure loss.
If the appliance is not equipped with the factory bypass
(optional), we strongly recommend to install a 3-valve bypass system (not included with this product!) to isolate the appliance from the water distribution system in case of repairs. It allows to turn off the water to the appliance, while maintaining (untreated) water supply to the user.
WITH FACTORY BYPASS (optional)
Picture 2
= mains water supply (untreated water) = inlet of appliance (untreated water) = outlet of appliance (treated water) = house/application (treated water)
1. Screw the factory bypass onto the elbow connections of
the appliance (&); make sure to install the gasket seals. Tighten the nuts firmly by hand.
2. Screw the connection kit with nuts onto the factory
bypass (&); make sure to install the gasket seals. Tighten the nuts firmly by hand.
3. Connect the mains water supply to the adaptor on the
inlet port of the factory bypass ().
4. Connect the house/application to the adaptor on the
outlet port of the factory bypass ().
WITH 3-VALVE BYPASS SYSTEM (not included)
Picture 3
= inlet of appliance (untreated water) = outlet of appliance (treated water)
1. Install the 3-valve bypass system.
2. Screw the connection kit with nuts onto the elbow
connections of the appliance (&); make sure to install the gasket seals. Tighten the nuts firmly by hand.
3. Connect the 3-valve bypass system to the adaptors on the
in () and out () elbow connections.
4. Connect the mains water supply to the inlet of the 3-valve
bypass system.
5. Connect the house/application to the outlet of the 3-valve
bypass system.
DRAIN
We recommend the use of a stand pipe with P-trap. To prevent backflow from the sewerage system into the
appliance, always install and use the included drain adaptor with air gap and double hose barb, to connect the drain hoses to the sewerage system.
Always use separate drain hoses for the control valve
(discharge of rinse water) and the brine cabinet's overflow.
Lay-out the drain hoses in such a way that pressure loss
is minimized; avoid kinks and unnecessary elevations.
Make sure that the sewerage system is suitable for the
rinse water flow rate of the appliance.
Picture 4
1. Install the drain adaptor to the sewerage system; it fits
over a 32 mm pipe or inside a 40 mm pipe adaptor. Ensure a permanent and watertight connection.
2. Connect a 13 mm hose to the drain solenoid of the control
valve (); secure it by means of a clamp.
3. Run the drain hose to the drain adaptor and connect it to
one of the hose barbs; secure it by means of a clamp. This drain line operates under pressure, so it may be installed higher than the appliance.
4. Connect a 13 mm hose to the brine cabinet overflow
elbow; secure it by means of a clamp.
5. Run the drain hose to the drain adaptor and connect it to
the other hose barb; secure it by means of a clamp. This drain line does NOT operate under pressure, so it may NOT be installed higher than the appliance.
BRINE CABINET (only for SOF-BBS-)
Picture 5
1. Run the polytube from the brine cabinet to the control
valve.
2. Insert the polytube into the Quick-Fit brine line
connection on the control valve ().
Page 6
COMMISSIONING
Page 6
ELECTRICAL
Picture 6
1. Plug the transformers output lead into the socket on the
appliances power cord; secure it by means of the TwistLock clamp.
2. Plug the transformer into an electrical outlet.
PRESSURIZING
1. Make sure the bypass system is in 'bypass' position.
2. Make sure the electronic controller of the appliance is in
service mode.
3. Open the mains water supply.
4. Open a cold treated water faucet nearby the appliance
and let the water run for a few minutes until all air is purged and all foreign material that may have resulted from the installation is washed out; close the tap.
5. Gently pressurize the appliance, by putting it into service:
factory bypass:
1. open the 'outlet' valve;
2. slowly open the 'inlet' valve.
3-valve bypass:
1. close the 'bypass' valve;
2. open the 'outlet' valve;
3. slowly open the 'inlet' valve.
6. After 2-3 minutes, open a cold treated water faucet
nearby the appliance and let the water run for a few minutes until all air is purged from the installation and the resin bed is rinsed (it is normal for the rinse water to show some discoloration!); close the tap.
7. Check the appliance and all hydraulic connections for
leaks.
After the first regenerations of the appliance, some
slight discoloration of the treated water might occur. This is totally harmless and will disappear rapidly!
BRINE CABINET
1. Add water conditioner salt to the brine cabinet.
ELECTRONIC CONTROL PANEL
1. Program the electronic controller.
ADJUSTMENT RESIDUAL HARDNESS
WITH FACTORY BYPASS (optional)
In practice the residual hardness is influenced by the
inlet pressure, flow rate and hardness of the incoming untreated water. When adjusting the residual hardness, make sure these conditions are similar to the actual operating conditions.
Picture 7
1. Adjust the residual hardness of the water that leaves the
appliance, by means of the adjusting screw, incorporated in the ‘outlet’ valve of the factory bypass: to raise the residual hardness: turn the screw counter
clockwise.
to reduce the residual hardness: turn the screw
clockwise.
8. Measure the residual water hardness with a water
hardness test kit; readjust if necessary.
PERFORM REGENERATION
1. Manually initiate a regeneration, by pressing the scroll
button; the display will show:
2. Leave the appliance in this position; the countdown timer
will countdown to 0 sec and start a regeneration.
Regen in 10 sec
Page 7
ELECTRONIC CONTROL PANEL
Page 7
Picture 8
symbol
button
function
SCROLL
to advance to the next
parameter
UP
to increase the value of the
parameter
DOWN
to decrease the value of the
parameter
POWER-UP
After power-up the display will show the 5-digit Part Number of the electronic board and the installed software version.
POWER FAILURE
In the event of a power failure, the program will remain stored in the NOVRAM® during an undefined period, while an incorporated SuperCap will maintain the correct time of day during a period of several hours; consequently, in case of prolonged power failure, the time of day might not be maintained; if this happens, the time of day will be reset to 8:00 when the power supply is re-established, while the indication will flash, indicating that the time of day needs to be set.
When the power failure occurs during the execution of an automatic regeneration, the appliance will immediately return to the service mode; when the power supply is re­established, the appliance will resume the regeneration.
TIMER FAILURE
In the event of a timer failure, the display will show the message:
The buzzer, if enabled (see Basic Settings), will beep continuously. If powering off/on the appliance doesn’t solve
this problem, professional service is required.
MAINTENANCE REMINDER
Only available if the maintenance reminder function has
been activated and programmed by your supplier!
Once the maintenance interval is reached, the following will happen:
1. the display will intermittently show the message:
2. the buzzer, if enabled (see Basic Settings), will beep 3
times every hour. While the appliance will continue to operate normally, it is recommended to have preventive maintenance performed by a professional.
To reset the maintenance reminder, simply access the
configuration parameters programming mode.
SERVICE MODE
In service mode the display shows: on 1
st
line: the time of day and the remaining capacity;
on 2
nd
line: the total volume of water used since
commissioning.
REGENERATION MODE
In regeneration mode the display shows the actual regeneration cycle and, where relevant, the total remaining regeneration time and remaining cycle time:
The appliance can be reset to service mode at any time by pressing the scroll  button, as such manually advancing it through the regeneration cycles.
CHECKING THE FLOW METER
In case of water usage, the remaining capacity counter in the service display will count back per unit, i.e. per litre. This way the correct functioning of the water meter can be verified.
MANUAL REGENERATION
It is possible to manually initiate an immediate regeneration or a delayed regeneration (at the preprogrammed time of regeneration).
1. Press the scroll
button; the display will show:
If the control panel is left in this position, the
countdown timer will countdown to 0 sec and start an immediate regeneration.
To cancel this mode, press the scroll
button before the countdown timer has reached 0 sec; the display will show:
8:01 1000L – TotVol: 1234567L
BRINE FILL
REGEN PENDING
Rgn:XXX CycY:ZZZ
8:01 1000L – Maintenance Now
Service Required
Regen in 10 sec
Regen @ 2:00
Page 8
ELECTRONIC CONTROL PANEL
Page 8
If the control panel is left in this position, a delayed
regeneration will be started at the indicated
preprogrammed time of regeneration.
To cancel this mode, press the scroll
button repeatedly; the control panel will return to the service mode.
PROGRAMMING INSTRUCTIONS -
BASIC SETTINGS
Before entering the programming mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode; any changes made will NOT be saved!
1. Press the scroll
button and hold it for 2 sec until the
display shows:
Press the up
or down  button to set the
language.
2. Press the scroll
button again; the display will show:
Press the up
or down  button to set the time of
day.
3. Press the scroll
button again; the display will show:
Press the up
or down  button to set the unit of measure for water hardness. Make sure it is identical to the unit of measure of the water hardness test kit or water analysis report that is used to determine the hardness of the incoming untreated water!
4. Press the scroll
button again; the display will show:
Press the up
or down button to set the hardness
of the incoming untreated water.
5. Press the scroll
button again; the display will show:
Press the up
or down  button to enable or
disable the buzzer.
6. Press the scroll
button again; the display will show:
Press the up
or down  button to save the settings
into the NOVRAM® and exit the programming mode.
PROGRAMMING INSTRUCTIONS -
CONFIGURATION PARAMETERS
All configuration parameters on this appliance have
been pre-programmed in the factory, to offer optimal performance in a wide range of applications and situations. See table at the end of this manual for default configuration parameter settings.
Before entering the programming mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode; any changes made will NOT be saved!
1. Press the scroll
button and hold it for 6 sec until the
display shows:
2. Within 10 sec, press the up
button; the display will
show:
Press the up
or down  button to set the units of
measure (Metric or US).
3. Press the scroll
button again; the display will show:
Press the up
or down button to activate the
maintenance reminder function by setting the maintenance interval, or deactivate the maintenance reminder function.
4. Press the scroll
button again; the display will show:
Press the up
or down  button to set the
exchange capacity per litre of resin.
5. Press the scroll
button again; the display will show:
Resin:XXX liters
MaintInt: OFF
Language:English
Set time: 8:01
Set hardn: XX °f
HardUnit: °f
Exit
Buzzer: ON
System Check
Units:Metric
ExCap:5.1°f M3/L
Page 9
ELECTRONIC CONTROL PANEL
Page 9
Press the up
or down  button to set the volume
of resin.
6. Press the scroll
button again; the display will show:
Press the up
or down  button to set the number
of days between regenerations.
7. Press the scroll
button again; the display will show:
Press the up
or down  button to set the length of the regeneration cycle.
Press the scroll
button again to advance to the next
regeneration cycle.
Eco
Eco+
Refill
Cycle 1
Cycle 1
Brine preparation
Cycle 2
Cycle 2
Backwash
/
Cycle 3
Brine draw/slow rinse
Cycle 3
Cycle 4
Fast rinse
/
Cycle 5
8. Press the scroll
button again; the display will show:
Press the up
or down  button to set the
regeneration mode: Dlyd/Immd: when the remaining capacity equals
the reserve capacity, a delayed regeneration is started at the programmed time of regeneration; however when the remaining capacity equals 0 before the programmed time of regeneration is reached, an immediate regeneration is started.
Immediate: when the remaining capacity equals
0, an immediate regeneration is started.
Delayed: when the remaining capacity equals the
reserve capacity, a delayed regeneration is started.
9. Press the scroll
button again; the display will show (only when the regeneration mode was set to 'Delayed' or 'Dlyd/Immd'):
Press the up
or down  button to set the time of
regeneration.
10. Press the scroll
button again; the display will show (only when the regeneration mode was set to 'Dlyd' or 'Dlyd/Immd'):
Press the up
or down  button to set the reserve
capacity: Variable: the reserve capacity is calculated
automatically, based on the registered daily water usage.
Fxd: press the scroll
button again and press the
up  or down button to set the reserve capacity to a fixed amount.
11. Press the scroll
button again; the display will show:
Press the up
or down  button to set the function
of auxilliary contact 1 and auxiliary contact 2: Regen: aux. contact is powered during entire
regeneration (does not include refill and brine preparation cycles!).
Chlor.Cell: aux. contact is powered at start of
brine draw/slow rinse cycle. Press the scroll  button again and press the up  or down  button to set the duration of activation of the chlorination cell.
Maintenance: aux. contact is powered when
Maintenance Reminder is triggered.
Error: aux. contact is powered when timer failure
occurs.
12. Press the scroll
button again; the display will show:
Press the up
or down  button to save the settings
into the NOVRAM® and exit the programming mode.
Exit
AUX: Regen
Override: 7 days
Cycle 1: XXX sec
Regen:Dlyd/Immd
Regen @ 2:00
Rsrv Variable
Page 10
ELECTRONIC CONTROL PANEL
Page 10
DIAGNOSTICS MODE
In the Diagnostics mode several operating parameters
can be consulted; particularly during a service intervention, these parameters can be helpful to identify the cause of a problem or malfunction.
Before entering the Diagnostics mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode!
Accessing the Diagnostics mode
1. Press the scroll
button and hold it for 6 sec until the
display shows:
2. Within 10 sec, press the down
button; the display will
show:
You are now in the Diagnostics mode. Press the scroll
button to advance to the next
diagnostics parameter.
Available diagnostics parameters
Regen X days ago: number of days since last
regeneration.
In Srvc: total number of days in service. # of Regens: number of regenerations since installation. TotVol: total volume of treated water since installation. LastSet: number of days since last change of configuration
parameter or hardness of incoming untreated water.
InstFlow: instantaneous flow rate through appliance. AvgVol: calculated average daily water usage. LastRgn@: consumed capacity at last regeneration. Capacity: calculated capacity between regenerations. MaintCnt: current status of maintenance reminder
counter (counting up).
MP Resets: number of resets of microprocessor (for
factory purpose only).
Memory Reset: number of corrupt memory start-ups (for
factory purpose only).
CapToUse: remaining capacity. Fill: length of refill cycle of last regeneration. Reserve: calculated reserve capacity. EZ3P5f EZ3PB r14: software version.
Exiting the Diagnostics mode
1. Press the scroll
button repeatedly until the display
shows:
Press the up
or down  button to exit the
Diagnostics mode.
Exit
System Check
Regen XXdays ago
Page 11
MAINTENANCE
Page 11
RECOMMENDATION
Notwithstanding the reliability of the appliance, we strongly recommend to have it serviced and maintained on a regular basis by a competent and duly trained technician. He will be able to determine the appropriate maintenance interval for the appliance, depending on your specific application and the local operating conditions. The advantages of performing regular maintenance are: regular check of the local operating conditions (water
quality, pressure, etc);
regular control and adjustment of the settings of the
appliance, to guarantee it operates at maximum efficiency;
minimize the risk of unexpected break-down. Contact your dealer or installer for more information, or visit our website.
ROUTINE CHECKS
Regularly the user should perform a basic check to verify if the appliance is functioning correctly, on the basis of the following control points:
1. Check settings of electronic control panel.
2. Measure water hardness before/after appliance.
3. Check drain line from control valve; there shouldn’t be
any water flow (unless appliance is in regeneration).
4. Check drain line from brine cabinet overflow; there
shouldn’t be any water flow.
5. Check appliance and surrounding area; there shouldn’t be
any water leakages.
BYPASSING THE APPLIANCE
Occasionally it may be necessary to put the appliance hydraulically in bypass, i.e. to isolate it from the water distribution system; f.e.:
in case of an urgent technical problem; when it is not necessary to supply treated water to the
house/application (refill swimming pool, irrigation,...).
WITH FACTORY BYPASS (optional)
Picture 9.a
SERVICE POSITION
= inlet valve to appliance is OPEN = outlet valve from appliance is OPEN
Picture 9.b
BYPASS POSITION
= inlet valve to appliance is CLOSED = outlet valve from appliance is CLOSED
Picture 9.c
MAINTENANCE POSITION
= inlet valve to appliance is OPEN = outlet valve from appliance is CLOSED
WITH 3-VALVE BYPASS SYSTEM (not included)
Picture 10.a
SERVICE POSITION
= bypass valve is CLOSED = inlet valve to appliance is OPEN = outlet valve from appliance is OPEN
Picture 10.b
BYPASS POSITION
= bypass valve is OPEN = inlet valve to appliance is CLOSED = outlet valve from appliance is CLOSED
Picture 10.c
MAINTENANCE POSITION
= bypass valve is OPEN = inlet valve to appliance is OPEN = outlet valve from appliance is CLOSED
WATER CONDITIONER SALT
Picture 11
The appliance needs 'brine' for its periodic regenerations. This brine solution is made from water, that is automatically dosed in the brine cabinet by the control valve, and water conditioner salt. The user should make sure that the brine cabinet is always kept full of water conditioner salt. Therefore he should periodically check the salt level inside the brine cabinet and refill it if necessary. The salt lid can be removed completely to facilitate refilling.
Ideally the level of water conditioner salt inside the brine cabinet is kept between 1/3 and 2/3. A lower level of water conditioner salt can cause insufficient brine saturation, resulting in a loss of softening capacity. A higher level of water conditioner salt can cause salt bridging (hard crust or salt bridges in the brine cabinet). When you suspect salt bridging: carefully pound on the outside of the brine cabinet to
break loose the salt bridges;
using a broom (or like blunt tool) carefully push the salt to
break it apart;
pour warm water over the top of the salt to dissolve it.
APPEARANCE
To retain the appearance of the appliance, simply wipe it with a damp cloth or clean it with a mild soap solution; never use abrasive cleaners, ammonia or solvents.
RESIN CLEANER
Other contaminants (f.e. iron) present in the feed water can cause the resin bed to foul up, resulting in a loss of softening capacity. An approved resin cleaner can be used periodically to thoroughly clean the resin bed.
Page 12
MAINTENANCE
Page 12
SANITIZING THE APPLIANCE
This appliance is manufactured from premium quality material and assembled in safe conditions to assure it is clean and sanitary. If installed and serviced correctly, this appliance will not infect or contaminate your water supply. However, as in any 'device' plumbed-in in your water distribution system, a proliferation of bacteria is possible, especially in case of 'stagnant water'. Therefore this appliance is equipped with a 'days override' feature, that will automatically rinse the resin bed periodically, even in case of low or absence of water usage.
If the power supply to the appliance is disconnected for a longer period of time, we recommend, when the power supply is re-established, to manually initiate a complete regeneration.
Page 13
HYDRAULIC FLOW DIAGRAMS - ECO
Page 13
SERVICE REFILL BRINE PREP. BRINE DRW SLOW RINSE
SERVICE REFILL
BRINE PREPARATION BRINE DRAW / SLOW RINSE
Page 14
HYDRAULIC FLOW DIAGRAMS - ECO+
Page 14
SERVICE REFILL BRINE PREP. BACKWASH BRINE DRAW SLOW RINSE FAST RINSE
SERVICE REFILL
BRINE PREPARATION BACKWASH
BRINE DRAW / SLOW RINSE FAST RINSE
Page 15
TROUBLESHOOTING
Page 15
PROBLEM
CAUSE
SOLUTION
Hard (untreated) water to service
Open or defective bypass
Close or replace bypass
Appliance in regeneration
Wait until regeneration finishes or manually advance regeneration to end
No salt in brine cabinet
Add salt and initiate regeneration manually
Salt bridging
Break salt bridge(s) and initiate regeneration manually
Change in raw water hardness
Measure the hardness of the incoming untreated water and adjust programming accordingly
Appliance fails to regenerate
Refer to problem “Appliance fails to regenerate
Control valve fails to draw brine
Refer to problem “Valve fails to draw brine”
Decreasing exchange capacity of resin
Clean or replace resin bed
Loss of resin
Refer to problem “Loss of resin”
Leak at riser tube
Verify that riser tube is seated correctly and is not cracked
Residual hardness in treated water
Bypass not completely closed
Close bypass
Appliance is overrunning its softening capacity Measure the hardness of the incoming untreated water and adjust programming accordingly
Verify operation of flow meter
Appliance fails to regenerate
Faulty electrical supply
Verify electrical service (fuse, transformer,...)
Defective flow meter
Verify operation of flow meter
Defective PCB
Replace PCB
Defective drain solenoid
Replace drain solenoid
Control valve does not switch to regeneration position
Check operating pressure; must be higher than 1,4 bar
Appliance uses too much salt
Excessive water in brine cabinet
Refer to problem “Excessive water in brine cabinet
System regenerates too frequently
Measure the hardness of the incoming untreated water and adjust programming accordingly
Excessive water in brine cabinet
Improper brine draw
Refer to problem “Improper brine draw
Improper setting of refill cycle
Verify setting of refill cycle
Missing refill flow control
Verify that refill flow control is installed and properly sized
Leak from control valve to brine cabinet
Clean or replace plunger and solenoid diaphragm of refill solenoid
Check seal between brine draw check ball and brine draw restrictor
Salt taste in treated water
Improper setting of brine draw/slow rinse cycle
Verify setting of brine draw/slow rinse cycle
Excessive water in brine tank
Refer to problem “Excessive water in brine tank”
Improper brine draw
Refer to problem “Improper brine draw
Loss of water pressure
Mineral or iron build-up in resin tank
Clean resin bed and control valve; increase regeneration frequency
Plugged lower and/or upper distributor
Verify that distributors are free of debris
Crushed lower and/or upper distributor
Replace distributor(s)
Drain line from control valve flows continuously
Appliance in regeneration
Wait until regeneration finishes or manually advance regeneration to end
Drain solenoid stuck in open position
Clean drain solenoid
Defective PCB
Replace PCB
Drain line from brine cabinet overflow flows continuously
Excessive water in brine cabinet
Refer to problem “Excessive water in brine cabinet
Leak between control valve and pressure tank
Verify seal between control valve and pressure tank
Control valve fails to refill brine tank
Improper setting of refill cycle
Verify setting of refill cycle
Plugged refill flow control
Clean refill flow control
Refill solenoid not opening
Verify operation of refill solenoid
Loss of resin
Lower and/or upper distributor damaged
Replace distributor(s)
Leak between riser tube and upper distributor
Verify that riser tube is seated correctly and is not cracked
Page 16
TROUBLESHOOTING
Page 16
PROBLEM
CAUSE
SOLUTION
Improper brine draw
Low operating pressure
Check operating pressure; must be higher than 1,4 bar
Plugged injector and/or brine draw restrictor
Clean injector and/or brine draw restrictor
Plugged injector filter
Clean injector filter
Restricted drain line
Verify drain line for kinks or restrictions
Restricted brine line
Verify brine line for kinks or restrictions
Leak in brine line
Verify brine line and connections for air leakage
No water in brine tank
Refer to problem “Control valve fails to refill brine tank”
Eco+ only: backwash solenoid remains open
Verify operation of backwash solenoid
Page 17
ELECTRICAL WIRING DIAGRAMS
Page 17
ECO
= flow meter    = power lead = auxilliary contacts (24 VAC, max. 500mA) = refill solenoid (white) = drain solenoid  = key pad
ECO+
= flow meter    = power lead = auxilliary contacts (24 VAC, max. 500mA) = refill solenoid (white) = backwash solenoid (black)  = drain solenoid = key pad
Page 18
DEFAULT CONFIGURATION PARAMETER SETTINGS - SOF-CS
Page 18
Model
SOF-CS-Eco-
Resin
11
15
20
26
32
Units
Metric
Metric
Metric
Metric
Metric
MaintInt (mths)
OFF
OFF
OFF
OFF
OFF
Exchange capacity per liter resin (°f M3/L)
(1) (2)
4,5
4,5
5,1
5,1
5,1
Resin (liters)
11
15
20
26
32
Override (days)
7 7 7 7 7
Cycle 1: REFILL (sec)
(2)
242
330
440
572
704
Cycle 2: BRINE PREPARATION (min)
15
15
15
15
15
Cycle 3: BRINE DRAW/SLOW RINSE (min)
55
75
93
118
144
Regen
Dlyd/Immd
Dlyd/Immd
Dlyd/Immd
Dlyd/Immd
Dlyd/Immd
Regen @
2:00
2:00
2:00
2:00
2:00
Rsrv
Variable
Variable
Variable
Variable
Variable
Auxilliary contact 1
Regen
Regen
Regen
Regen
Regen
Auxilliary contact 2
Regen
Regen
Regen
Regen
Regen
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit. (2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Model
SOF-CS-Eco+-
Resin
11
15
20
26
Units
Metric
Metric
Metric
Metric
MaintInt (mths)
OFF
OFF
OFF
OFF
Exchange capacity per liter resin (°f M3/L)
(1) (2)
4,5
4,5
5,1
5,1
Resin (liters)
11
15
20
26
Override (days)
7 7 7
7
Cycle 1: REFILL (sec)
(2)
242
330
440
572
Cycle 2: BRINE PREPARATION (min)
15
15
15
15
Cycle 3: BACKWASH (min)
3 3 3
3
Cycle 4: BRINE DRAW/SLOW RINSE (min)
55
75
113
138
Cycle 5: FAST RINSE (min)
2 2 2
2
Regen
Dlyd/Immd
Dlyd/Immd
Dlyd/Immd
Dlyd/Immd
Regen @
2:00
2:00
2:00
2:00
Rsrv
Variable
Variable
Variable
Variable
Auxilliary contact 1
Regen
Regen
Regen
Regen
Auxilliary contact 2
Regen
Regen
Regen
Regen
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit. (2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Page 19
DEFAULT CONFIGURATION PARAMETER SETTINGS - SOF-BBS
Page 19
Model
SOF-BBS-Eco-
Resin
11
32
Units
Metric
Metric
MaintInt (mths)
OFF
OFF
Exchange capacity per liter resin (°f M3/L)
(1) (2)
4,5
5,1
Resin (liters)
11
32
Override (days)
7
7
Cycle 1: REFILL (sec)
(2)
242
704
Cycle 2: BRINE PREPARATION (min)
15
15
Cycle 3: BRINE DRAW/SLOW RINSE (min)
55
144
Regen
Dlyd/Immd
Dlyd/Immd
Regen @
2:00
2:00
Rsrv
Variable
Variable
Auxilliary contact 1
Regen
Regen
Auxilliary contact 2
Regen
Regen
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit. (2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Model
SOF-BBS-Eco+-
Resin
11
26
Units
Metric
Metric
MaintInt (mths)
OFF
OFF
Exchange capacity per liter resin (°f M3/L)
(1) (2)
4,5
5,1
Resin (liters)
11
26
Override (days)
7
7
Cycle 1: REFILL (sec)
(2)
242
572
Cycle 2: BRINE PREPARATION (min)
15
15
Cycle 3: BACKWASH (min)
3
3
Cycle 4: BRINE DRAW/SLOW RINSE (min)
55
138
Cycle 5: FAST RINSE (min)
2
2
Regen
Dlyd/Immd
Dlyd/Immd
Regen @
2:00
2:00
Rsrv
Variable
Variable
Auxilliary contact 1
Regen
Regen
Auxilliary contact 2
Regen
Regen
(1) When the Hardness Unit is changed in the Basic Settings, the Exchange capacity per liter resin is automatically converted to the new Hardness Unit. (2) When the Exchange capacity per liter resin is changed, the refill cycle time needs to be adjusted accordingly.
Page 20
EXPLODED VIEW - SOF-CS - SYSTEM
Page 20
Page 21
EXPLODED VIEW - SOF-CS - SYSTEM
Page 21
Item
PN
Description
Remark
(*)
1
PT/0918/CP
Pressure tank, 9x18
Eco 11L, Eco+ 11L
PT/0924/CP
Pressure tank, 9x24
Eco 15L, Eco+ 15L
PT/1024/CP
Pressure tank, 10x24
Eco 20L 
PT/0935/CP
Pressure tank, 9x35
Eco 26L, Eco+ 20L
PT/1035/CP
Pressure tank, 10x35
Eco 32L, Eco+ 26L
2 E8000
Softening resin
 3
38528
Riser tube assembly with deflector
to be cut to length
4 287/166
Top distributor
 5
568/303/6
Connection kit ¾” male
6
541NCX9B/J80
Valve body assembly
Eco 
541NCX4B/J8G
Valve body assembly
Eco+ 11L, Eco+ 15L, Eco+ 20L
541NCX4B/J8J
Valve body assembly
Eco+ 26L
7
28/298/11
Transformer 230/24V - 50 Hz, 24VA, EuroT plug
 8 Cover assembly
9
39065
Thumb screw (2x)
 10
38544
Salt lid
 11
H1015/2
Brine line polytube
to be ordered per meter
12
38519
Brine line filter
 13
H1016/2
Brine well cap, top
14
DM/A6EU6
Quick-fit elbow 3/8”
 15
38530
Brine valve assembly 464
to be cut to length
16
BW3.5/0403
Brine well, 403 mm
Eco 11L, Eco+ 11L
BW3.5/0538
Brine well, 538 mm
Eco 15L, Eco 20L, Eco+ 15L
BW3.5/0823
Brine well, 823 mm
Eco 26L, Eco 32L, Eco+ 20L, Eco+ 26L
17
H1016/4
Brine well cap, bottom
18
38548
Screw rivet, brine well
19
39089
Cabinet body, mini
Eco 11L, Eco+ 11L
39090
Cabinet body, midi
Eco 15L, Eco 20L, Eco+ 15L
39091
Cabinet body, maxi
Eco 26L, Eco 32L, Eco+ 20L, Eco+ 26L
20
38532
Overflow assembly
21
39004
Dome label ‘erie water treatment’
22
39099
Label ‘Softena’ (mini)
Eco 11L, Eco+ 11L
39100
Label ‘Softena’ (midi)
Eco 15L, Eco 20L, Eco+ 15L
39101
Label ‘Softena’ (maxi)
Eco 26L, Eco 32L, Eco+ 20L, Eco+ 26L
23
74267
Cable clamp
to be ordered per meter
24
38522
Drain hose
25
74163
Air gap with double hose barb
26
38521
Clamp, drain hose (4x)
(*) Recommended Spare Part
Page 22
EXPLODED VIEW - SOF-CS - COVER ASSEMBLY
Page 22
Page 23
EXPLODED VIEW - SOF-CS - COVER ASSEMBLY
Page 23
Item
PN
Description
Remark
(*)
1
38511
Thumb screw, PCB cover
 2
38545
PCB cover
3
15/102
Screw, PCB
4
74280
Printed Circuit Board
Eco 
74279
Printed Circuit Board
Eco+  5
38551
Cover assembly
6
72685
Backwash solenoid cable (black)
Eco+  7
72686
Refill solenoid cable (white)
 8
72761
Drain solenoid cable
 9
72760
Flow meter cable
10
70971
Power cord
11
72263
Twist lock clamp, power cord
(*) Recommended Spare Part
Page 24
EXPLODED VIEW - SOF-BBS - SYSTEM
Page 24
Page 25
EXPLODED VIEW - SOF-BBS - SYSTEM
Page 25
(*) Recommended Spare Part
Item
PN
Description
Remark
(*)
1
PT/0918/BA
Pressure tank 9x18
Eco 11L, Eco+ 11L
PT/1035/BA
Pressure tank 10x35
Eco 32L, Eco+ 26L
2
E8000
Softening resin
3
39004
Dome label ‘erie water treatment’
4
39099
Label ‘Softena’ (mini)
Eco 11L, Eco+ 11L
39100
Label ‘Softena’ (midi)
Eco 32L, Eco+ 26L
5 J/0918(W)
Tank jacket, mini
Eco 11L, Eco+ 11L
J/1035(W)
Tank jacket, maxi
Eco 32L, Eco+ 26L
6
38528
Riser tube assembly with deflector
to be cut to length
7 287/166
Top distributor
 8
J/09
Tank jacket cover 9”
Eco 11L, Eco+ 11L
J/10
Tank jacket cover 10”
Eco 32L, Eco+ 26L
9 568/232
Nut, connection kit (2x)
10
74129
Adaptor ¾” BSP male plastic (2x)
11
71110
Gasket, connection kit (4x)
 12
72639
Bypass with mixing valve
optional
13
541N89/J80/SOF
Valve body & timer assembly
Eco 11L, Eco 32L
541N84/J8G/SOF
Valve body & timer assembly
Eco+ 11L
541N84/J8J/SOF
Valve body & timer assembly
Eco+ 26L
14
28/298/11
Transformer 230/24V - 50 Hz, 24VA, EuroT plug
 15 Brine cabinet cover
included in item 26
16
H1015/2
Brine line polytube
to be ordered per meter
17
74179
Brine line filter
 18
H1016/2
Brine well cap, top
19
DM/A6EU6
Quick-fit elbow 3/8”
 20
38530
Brine valve assembly 464
to be cut to length
21
BW3.5/0375
Brine well
Eco 11L, Eco+ 11L
BW3.5/072
Brine well
Eco 32L, Eco+ 26L
22
H1016/4
Brine well cap, bottom
23
38522
Drain hose
to be ordered per meter
24
74163
Air gap with double hose barb
25
38521
Clamp, drain hose (4x)
26
39105
Brine cabinet, mini
Eco 11L, Eco+ 11L
39106
Brine cabinet, maxi
Eco 32L, Eco+ 26L
27
38547
Screw rivet
28
38532
Overflow assembly
Page 26
EXPLODED VIEW - VALVE BODY ASSEMBLY - ECO
Page 26
Page 27
EXPLODED VIEW - VALVE BODY ASSEMBLY - ECO
Page 27
Item
PN
Description
Remark
(*)
1
15/90
Screw, solenoid retainer (4x)
2 413/134/24
Solenoid
3
541/229
Retainer, solenoid
4
413/58
Guide, solenoid
5 413/62
Spring, solenoid plunger
6 74099
Plunger, solenoid
7 74098
Diaphragm, solenoid
8 15/222
Screw, back cap (4x)
9 541/286/3
Back cap
10
74258
Brine elbow
11
74022
Brine draw restrictor 1,0 mm (black)
12
541/275
Check ball
13
568/385/2/A
Refill flow control 0,25 gpm
14
541/206
Gasket, back cap
15
541/239
Spring, check disc
16
541/246
Check disc
17
15/89
Screw, cover plate (3x)
18
541/221
Cover plate, injector
19
428/5
Injector disc #5
20
541/325
Gasket, injector
21
74179
Filter, injector
22
72609
Locking plate, drain flow adjuster
23
15/76
Screw, locking plate
24
541/254
Spring clip
25
186/118
O-ring, brine plug
26
541/273
Brine plug
27
72467
Union gasket (2x)
28
72542
Elbow, inlet
29
19/19
Clip, drain flow adjuster
30
186/134
O-ring, drain flow adjuster (2x)
31
541/238
Drain flow adjuster
32
529/244
O-ring, drain port
33
467/216
Seal, body stem
34
72605
Body stem
35
185/024/1
O-ring, seat insert (small)
36
541/204
Seat insert
37
185/029/1
O-ring, seat insert (large)
38
72602
Main diaphragm
39
72507
Retainer, main diaphragm
40
72245
Washer, main diaphragm
41
72552
Screw, main diaphragm
42
516/221
Spring, main diaphragm
43
15/90
Screw, adapter ring (2x)
44
185/67/4
O-ring, tank
45
541/232
Adapter ring
46
185/214/1
O-ring, riser tube
47
541/218
Riser insert 1,050”
48
185/029/1
O-ring, riser insert
49
541/257/1
Valve body (incl. 467/216)
50
72543
Elbow, outlet
51
72544
Impeller
52
72545
Hub, Impeller
A RK/413
Repair kit solenoid diaphragm
B
RK/541/244
Repair kit body stem and seat
C
72611
Repair kit body stem
(*) Recommended Spare Part
Page 28
EXPLODED VIEW - VALVE BODY ASSEMBLY - ECO+
Page 28
Page 29
EXPLODED VIEW - VALVE BODY ASSEMBLY - ECO+
Page 29
Item
PN
Description
Remark
(*)
1
15/90
Screw, solenoid (6x)
2
413/134/24
Solenoid (2x)
3
541/229
Retainer, solenoid
4
413/58
Guide, solenoid (2x)
5
413/62
Spring, solenoid plunger (2x)
 6
74099
Plunger, solenoid (2x)
 7
74098
Diaphragm, solenoid (2x)
 8
15/222
Screw, back cap (4x)
9
541/274/3
Back cap
10
74258
Brine elbow
11
74022
Brine draw restrictor 1,0 mm (black)
12
541/275
Check ball
 13
568/385/2/A
Refill flow control 0,25 gpm
14
541/206
Gasket, back cap
15
541/239
Spring, check disc
16
541/246
Check disc
17
15/89
Screw, cover plate (3x)
18
541/221
Cover plate, injector
19
428/5
Injector disc #5
 20
541/325
Gasket, injector
 21
74179
Filter, injector
 22
72609
Locking plate, drain flow adjuster
23
15/76
Screw, locking plate
24
541/254
Spring clip
25
186/118
O-ring, brine plug
26
541/273
Brine plug
27
72467
Union gasket (2x)
 28
72542
Elbow, inlet
29
19/19
Clip, drain flow adjuster
30
186/134
O-ring, drain flow adjuster (2x)
31
541/238
Drain flow adjuster
32
529/244
O-ring, drain port
33
467/216
Seal, body stem
34
72605
Body stem
 35
185/024/1
O-ring, seat insert (small)
36
541/204
Seat insert
37
185/029/1
O-ring, seat insert (large)
38
72602
Main diaphragm
 39
72507
Retainer, main diaphragm
40
72245
Washer, main diaphragm
41
72552
Screw, main diaphragm
42
516/221
Spring, main diaphragm
43
15/90
Screw, adapter ring (2x)
44
185/67/4
O-ring, tank
 45
541/232
Adapter ring
46
185/214/1
O-ring, riser tube
47
541/218
Riser insert 1,050”
48
185/029/1
O-ring, riser insert
49
541/257/1
Valve body (incl. 467/216)
50
72543
Elbow, outlet
 51
72544
Impeller
 52
72545
Hub, Impeller
A
RK/413
Repair kit solenoid diaphragm
B
RK/541/244
Repair kit body stem and seat
C
72611
Repair kit body stem
(*) Recommended Spare Part
Page 30
EXPLODED VIEW - SOF-CS - VALVE HEAD ASSEMBLY
Page 30
Item
PN
Description
Remark
(*)
1
15/87
Screw, valve head
2
72216
Valve head
3
541/300/G
Drain flow control 2,0 gpm
Eco+ 11L, Eco+ 15L, Eco+ 20L
541/300/J
Drain flow control 2,6 gpm
Eco+ 26L
4 185/115/1
O-ring, drain line adaptor
5
74018
Nut, drain solenoid
6
74016
Drain line adaptor
7
74019
Gasket, drain solenoid
8
74023
Drain solenoid
(*) Recommended Spare Part
Page 31
EXPLODED VIEW - SOF-BBS - VALVE HEAD & TIMER ASSEMBLY
Page 31
Item
PN
Description
Remark
(*)
1
72263
Twist lock clamp, power cord
2
70971
Power cord
 3
72519
Flow meter cable
 4.a
71681
Backwash solenoid cable (black)
Eco+  4.b
71682
Refill solenoid cable (white)
 5
72561
Drain solenoid cable
 6
74023
Drain solenoid
 7
74019
Gasket, drain solenoid
8
74016
Drain line adaptor
9
74018
Nut, drain solenoid
10
185/115/1
O-ring, drain line adaptor
11
541/300/G
Drain flow control 2,0 gpm
Eco+ 11L
541/300/J
Drain flow control 2,6 gpm
Eco+ 26L
12
72216
Valve head
13
74262
Screw, timer housing (2x)
Standard metric thread (ISO)
14
74189
Timer mounting bracket
15
15/87
Screw, valve head (4x)
16
28/8/28
Strain relief (2x)
17
74026
PCB housing back
18
15/102
Screw, PCB (2x)
19
74280
Printed Circuit Board
Eco 
74279
Printed Circuit Board
Eco+  20
74230
PCB housing front assembly
Standard metric thread (ISO)
Page 32
TECHNICAL DATA - SOF-CS-ECO
Page 32
Technical specifications:
Model
SOF-CS-Eco
Resin (Ltr)
11
15
20
26
32
Operating pressure min/max (bar)
1,4/8,3
Operating temperature min/max (°C)
2/48
Electrical connection (V/Hz)
230/50
(1)
Maximum power consumption (VA)
17
Hydraulic connection inlet/outlet
¾” BSP Male
(1) Supplied with 24V transformer
Performances @ 3 bar operating pressure
(2)
:
Model
SOF-CS-Eco
Resin (Ltr)
11
15
20
26
32
Nominal exchange capacity (m³x°f)
50
68
102
133
163
Nominal exchange capacity (m³x°d)
28
38
58
75
93
Service flow rate @∆p 1 bar (m³/hr)
2,3
2,1
2,2
2,0
2,0
Recommended maximum service flow (m³/hr)
(3)
1,1
1,5
2,0
2,6
3,2
Salt usage per regeneration (kg)
(4)
1,4
1,9
2,5
3,3
4,0
Rinse water usage per regeneration (Ltr)
(4)
59
80
101
128
156
(2) Indicative numbers, performances depending on operating conditions and water quality (3) Flow rate at which softening process is still executed adequately (4) Maximum salt/water usage as brining is proportional (minimum of 60%)
Dimensions & weights:
Model
SOF-CS-Eco
Resin (Ltr)
11
15
20
26
32
Width (mm) (W)
573
Height (mm) (H)
667
807
807
1.086
1.086
Depth (mm) (D)
345
Depth, including bypass (mm)
418
Height inlet/outlet (mm)
514
654
654
933
933
Height inlet/outlet, including bypass (mm)
520
660
660
939
939
Weight (kg)
18,5
24,0
28,5
35,5
41,0
Weight, including bypass (kg)
19,0
24,5
29,0
36,0
41,5
Maximum salt storage capacity (kg)
50
75
75
125
125
Page 33
TECHNICAL DATA - SOF-CS-ECO+
Page 33
Technical specifications:
Model
SOF-CS-Eco+
Resin (Ltr)
11
15
20
26
Operating pressure min/max (bar)
1,4/8,3
Operating temperature min/max (°C)
2/48
Electrical connection (V/Hz)
230/50
(1)
Maximum power consumption (VA)
21
Hydraulic connection inlet/outlet
¾” BSP Male
(1) Supplied with 24V transformer
Performances @ 3 bar operating pressure
(2)
:
Model
SOF-CS-Eco+
Resin (Ltr)
11
15
20
26
Nominal exchange capacity (m³x°f)
50
68
102
133
Nominal exchange capacity (m³x°d)
28
38
58
75
Service flow rate @∆p 1 bar (m³/hr)
2,3
2,1
2,0
2,1
Recommended maximum service flow (m³/hr)
(3)
1,1
1,5
2,0
2,6
Salt usage per regeneration (kg)
(4)
1,4
1,9
2,5
3,3
Rinse water usage per regeneration (Ltr)
(4)
97
118
158
197
(2) Indicative numbers, performances depending on operating conditions and water quality (3) Flow rate at which softening process is still executed adequately (4) Maximum salt/water usage as brining is proportional (minimum of 60%)
Dimensions & weights:
Model
SOF-CS-Eco+
Resin (Ltr)
11
15
20
26
Width (mm) (W)
573
Height (mm) (H)
667
807
1.086
1.086
Depth (mm) (D)
345
Depth, including bypass (mm)
418
Height inlet/outlet (mm)
514
654
933
933
Height inlet/outlet, including bypass (mm)
520
660
939
939
Weight (kg)
19,0
24,0
30,5
36,5
Weight, including bypass (kg)
19,5
24,5
31,0
37,0
Maximum salt storage capacity (kg)
50
75
125
125
Page 34
TECHNICAL DATA - SOF-BBS-ECO
Page 34
Technical specifications:
Model
SOF-BBS-Eco
Resin (Ltr)
11
32
Operating pressure min/max (bar)
1,4/8,3
Operating temperature min/max (°C)
2/48
Electrical connection (V/Hz)
230/50
(1)
Maximum power consumption (VA)
17
Hydraulic connection inlet/outlet
¾” BSP Male
(1) Supplied with 24V transformer
Performances @ 3 bar operating pressure
(2)
:
Model
SOF-BBS-Eco
Resin (Ltr)
11
32
Nominal exchange capacity (m³x°f)
50
163
Nominal exchange capacity (m³x°d)
28
93
Service flow rate @∆p 1 bar (m³/hr)
2,3
2,0
Recommended maximum service flow (m³/hr)
(3)
1,1
3,2
Salt usage per regeneration (kg)
(4)
1,4
4,0
Rinse water usage per regeneration (Ltr)
(4)
59
156
(2) Indicative numbers, performances depending on operating conditions and water quality (3) Flow rate at which softening process is still executed adequately (4) Maximum salt/water usage as brining is proportional (minimum of 60%)
Dimensions & weights:
Model
SOF-BBS-Eco
Resin (Ltr)
11
32
Brine tank width x depth (mm x mm)
290x310
Brine tank height (mm)
435
905
System depth (pressure tank & valve) (mm)
270
278
System depth, including bypass (mm)
372
380
System height (mm)
594
1.030
Height inlet/outlet (mm)
501
937
Height inlet/outlet, including bypass (mm)
507
943
Weight (kg)
16,0
38,0
Weight, including bypass (kg)
16,5
38,5
Maximum salt storage capacity (kg)
30
65
Page 35
TECHNICAL DATA - SOF-BBS-ECO+
Page 35
Technical specifications:
Model
SOF-BBS-Eco+
Resin (Ltr)
11
26
Operating pressure min/max (bar)
1,4/8,3
Operating temperature min/max (°C)
2/48
Electrical connection (V/Hz)
230/50
(1)
Maximum power consumption (VA)
21
Hydraulic connection inlet/outlet
¾” BSP Male
(1) Supplied with 24V transformer
Performances @ 3 bar operating pressure
(2)
:
Model
SOF-BBS-Eco+
Resin (Ltr)
11
26
Nominal exchange capacity (m³x°f)
50
133
Nominal exchange capacity (m³x°d)
28
75
Service flow rate @∆p 1 bar (m³/hr)
2,3
2,1
Recommended maximum service flow (m³/hr)
(3)
1,1
2,6
Salt usage per regeneration (kg)
(4)
1,4
3,3
Rinse water usage per regeneration (Ltr)
(4)
97
197
(2) Indicative numbers, performances depending on operating conditions and water quality (3) Flow rate at which softening process is still executed adequately (4) Maximum salt/water usage as brining is proportional (minimum of 60%)
Dimensions & weights:
Model
SOF-BBS-Eco+
Resin (Ltr)
11
26
Brine tank width x depth (mm x mm)
290x310
Brine tank height (mm)
435
905
System depth (pressure tank & valve) (mm)
270
278
System depth, including bypass (mm)
372
380
System height (mm)
594
1.030
Height inlet/outlet (mm)
501
937
Height inlet/outlet, including bypass (mm)
507
943
Weight (kg)
16,5
32,5
Weight, including bypass (kg)
17,0
33,0
Maximum salt storage capacity (kg)
30
65
Page 36
Page 36
Page 37
Page 37
Page 38
Page 38
Page 39
Page 39
Page 40
Manufactured & Assembled by
erie water treatment
a division of Aquion, Inc.
www.eriewatertreatment.com