Sofratec EB2000 User Manual

Page 1
PAGE 1
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Rev. 2.0 - 06/03
EB2000
87.5 ÷ 108 MHz FM 2000W TRANSMITTER
Page 2
PAGE 2
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
CONTENTS
1 INTRODUCTION....................................................................................................3
2 GENERAL DESCRIPTION ...................................................................................4
3 TECHNICAL FEATURES .....................................................................................5
4 TECHNICAL SPECIFICATIONS..........................................................................8
5 INSTALLATION AND USE....................................................................................9
5.1 FOREWORD TO INSTALLATION ............................................................9
5.2 PLACING THE APPARATUS ....................................................................10
5.3 WIRING INTO THE MAINS.....................................................................11
5.4 SYSTEM CONNECTION ...........................................................................12
5.5 LF CONNECTION AND PRESETS ..........................................................13
5.6 OPERATION................................................................................................18
6 COMMANDS AND PROGRAMMING..............................................................21
6.1 PASSWORD ORGANISATION.................................................................21
6.2 FACTORY DEFAULT PASSWORDS........................................................22
6.3 MENU AND COMMANDS DESCRIPTION ...........................................23
7 SERVICE AND MAINTENANCE .......................................................................33
8 GUARANTEE.........................................................................................................34
9 SERVICE MANUAL..............................................................................................35
9.1 INTERNAL DESCRIPTION ......................................................................35
DRAWINGS
EB2000, top & front assembly view EB2000, rear internal view
EB2000, general electric diagram (E1024) EB2000, exciter assembly electric diagram (E0909) SEXC25AL5, auxiliary power regulator board (E0805A) EXC25CON, cpu controller and display board (E0838) EXC1K05IN, input & interface board (E0911) EXC25MB, lf and rf control mainboard (E0837) SEXC23COD2, stereo encoder board (E0868) SEXC25MOD, FM exciter board (E0839) ASEXC25AM5, 25W FM driver amplifier (E0691) ASRFB2K0RF, 2KW amplifier assembly (E1018) SRFB2K0LP, 2KW low pass filter (E1017) SRFB500W, 500Wamplifier module SRFB1K5ALM, 48V/70A SMPS regulator module
EXB 2000 USER AND MAINTENANCE MANUAL
Page 3
PAGE 3
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
EXC 2005
87.5 ÷ 108 MHz FM 2000W TRANSMITTER
1. INTRODUCTION
The EB2000 series transmitters are the result of experience gained by SOFRATEC during years of
producing FM broadcast equipment, transmitters, stl and stereo encoders.
These transmitters were specifically designed to comply with the latest international standards and the requirements of advanced broadcasters, meeting tighter specifications than usually required, at an affordable cost.
Great care went into besides the producing a Hi-Fi-quality modulated signal, with low residual noise and distortion. RF signal is free from spurious and harmonic components to a higher degree than required by CCIR, European, USA and most other national standards.
In order to obtain this outstanding performance, SOFRATEC strongly recommend to rely on qualified personnel to install and verify the equipment which builds up the radio station, i.e. the transmitter, the possible stl and power amplifier, the corresponding antennas, cables and connectors. This will assure the best performance and stability in time.
To this aim, we especially recommend that our equipment should not be tampered with by unskilled personnel and our after-sale service is available to customers for any technical problem. Before proceeding to the installation, please carefully read at least the general installation part of this manual, to gain confidence with the equipment.
The transmitters are very stable and changes to the internal pre-setting other than frequency and few other options are not usually required but, if they are, once again we repeat that they must be carried out by skilled personnel, with the proper instruments and service documentation. Improperly tampering with the settings may harm the apparatus or jeopardize the guaranteed performance.
THIS EQUIPMENT COMPLIES WITH ALL RELEVANT EMI/EMC AND SAFETY REQUIREMENTS, ETSI EN300384, ETS300447 AND EN60215 STANDARDS.
NO INTERNAL ADJUSTMENT OR PRESETTING IS REQUIRED DURING NORMAL OPERATIONS. THE APPARATUS SHALL BE PROPERLY EARTHED AND BE OPERATED WITH ALL THE COVERS CLOSED TO PREVENT ELECTRICAL HAZARDS AND COMPLY WITH EMC STANDARDS.
——— MAINS VOLTAGE MAY KILL ———
Page 4
PAGE 4
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
2. GENERAL DESCRIPTION
The EB2000 is a 2000W rated, direct-synthesis, FM-modulated transmitter. Being digitally controlled, it is extensively on field programmable by front panel or remotely in every respect: frequency, power, channel sensitivity, preemphasis, functioning mode (mono, stereo, external mpx), clock and date and many other parameters without adjusting or replacing any part. A powerful 3-levels password management permits a very high degree of security and privacy as may be required in different situations. The apparatus requires little or no maintenance and its simple modular layout allows easy stage testing and servicing.
As required by various national standards, these transmitters incorporate sophisticated low-pass audio filters on mono and stereo channels, and a sharp acting modulation limiter, which is usually set at a peak deviation slightly higher than 75 kHz. Its intervention may nevertheless be avoided, if required, by pre-setting its threshold at a deviation higher than 150 kHz.
Output frequency is phase-locked to a temperature-compensated crystal oscillator, which ensures superior precision and stability. A very low noise, low distortion VCO produces a harmonic-free, spurious-free signal. A lock control circuit inhibits the presence of power on the output until the apparatus is on the right frequency, when it is turned on.
To lower the noise threshold further, the low-frequency inputs are fitted with balanced input circuitry. The input level is precisely adjustable over a broad range, by means of a 0.5dB stepwise variable attenuators. The transmitter has an auxiliary input, specifically designed for RDS and SCA encoders. A modulation output permits to control other transmitters or STL's with the same internally processed high-quality mpx signal.
The alphanumeric display permits easy and accurate metering, adjustment and continuous monitoring of modulation levels, power, operation and internal parameters. Such details may be externally available on the same RS232 I/O port that may be used to remotely control the transmitter. In addition to the serial I/O, some signals (RF power, On the air state, Disable line) are available on a parallel I/O socket for easy interfacing with others analog controllers or supervisory systems.
A top-quality stereo encoder may be factory installed as option and even retrofitted later in the field, requiring minimum technical skill. The powerful internal software and monitoring functions recognise its presence and enable its functions.
The RF power amplifier employs a broadband design and has plenty of reserve: the output power is feed ack controlled for increased stability to a higher level than the nominal one. High reflected power is limited to prevent output stage degradation; direct power is accordingly continuously reduced so as not to exceed the reflected power safety level. A sturdy telecom-grade high efficiency switch-mode power supply permits operation in a very wide and noisy mains environment.
The temperature alarm circuitry reduce the output power in case of high room or esternal temperature, trying to stay on the air in spite of the adverse conditions.
Page 5
PAGE 5
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
3. TECHNICAL FEATURES
3.1 FRONT PANEL COMMANDS AND SIGNALLING
The EB2000 front panel is clean and easy to control. The wide alphanumeric display and the control
keyboard permit a simple self-explanatory menu-driven navigation through the various options.
Great care was taken in the design of the software to allow a natural approach to the controls and allow operation and programming in every respect of the apparatus without needing to extensively read the user's manual.
The password management, hides some functions and prevents tampering with the most critical options and data to unauthorised people.
The on/stand-by key does not power off the apparatus, which is still locked on frequency and ready to transmit as soon as the key is pushed or a remote command is sent.
Some leds signal at a glance proper functioning and warning states.
Page 6
PAGE 6
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
IN CASE OF DUCTING OF THE VENTILATION AIR,
AN EXTERNAL EXTRACTING FAN IS REQUIRED.
LEFT
AUDIO INPUT
RIGHT
REMOTE
2 Signal -
1 Ground
3 Signal +
231
20k-100k
MODULATION
MONITOR RS232AUX MPX
10-100000 Hz
RF OUTPUT
50 OHM
MADE IN ITALY
0678
ABSOLUTELY REMOVE POWER CORD FROM MAINS
GROUND
UPPER AND BOTTOM COVERS ARE REQUIRED TO
ELECTRICAL SHOCKS, DO NOT REMOVE ANY PANEL.
MEET BOTH SAFETY AND EMI REQUIREMENTS.
CIRCUITS AT THE REAR OF THIS PANEL ARE
CONNECTED TO MAINS VOLTAGE. TO PREVENT
CAUTION!
POWER
ON
I PANNELLI DI CHIUSURA SUPERIORE ED INFERIORE
PRIMA DI CAMBIARE I FUSIBILI INTERNI, DISCONNETTERE
SONO RICHIESTI PER LA CONFORMITA' AGLI STANDARD
DI SICUREZZA E DI EMISSIONE ELETTROMAGNETICA.
ASSOLUTAMENTE IL COLLEGAMENTO ALLA RETE
NON RIMUOVERE LE COPERTURE. INOLTRE ENTRAMBI
RETE. PER EVITARE RISCHI DA SCOSSA ELETTRICA
SUL RETRO DI QUESTO PANNELLO SONO DIRET-
TAMENTE ACCESSIBILI CIRCUITI A TENSIONE DI
BEFORE REPLACING INTERNAL FUSES.
ATTENZIONE!
E' RICHIESTO UN GRUPPO DI ASPIRAZIONE ESTERNO.
IN CASO DI CONVOGLIAMENTO DELL'ARIA DI VENTILAZIONE
4500VA (RFB2001)
230Vac 50/60Hz
2500VA (RFB1001)
OFF
0678
SISTEMI
ELETTRONICI
IN CASE OF DUCTING OF THE VENTILATION AIR,
AN EXTERNAL EXTRACTING FAN IS REQUIRED.
LEFT
AUDIO INPUT
RIGHT
REMOTE
2 Signal -
1 Ground
3 Signal +
231
20k-100k
MODULATION
MONITOR RS232AUX MPX
10-100000 Hz
RF OUTPUT
50 OHM
MADE IN ITALY
0678
ABSOLUTELY REMOVE POWER CORD FROM MAINS
GROUND
UPPER AND BOTTOM COVERS ARE REQUIRED TO
ELECTRICAL SHOCKS, DO NOT REMOVE ANY PANEL.
MEET BOTH SAFETY AND EMI REQUIREMENTS.
CIRCUITS AT THE REAR OF THIS PANEL ARE
CONNECTED TO MAINS VOLTAGE. TO PREVENT
CAUTION!
POWER
ON
I PANNELLI DI CHIUSURA SUPERIORE ED INFERIORE
PRIMA DI CAMBIARE I FUSIBILI INTERNI, DISCONNETTERE
SONO RICHIESTI PER LA CONFORMITA' AGLI STANDARD
DI SICUREZZA E DI EMISSIONE ELETTROMAGNETICA.
ASSOLUTAMENTE IL COLLEGAMENTO ALLA RETE
NON RIMUOVERE LE COPERTURE. INOLTRE ENTRAMBI
RETE. PER EVITARE RISCHI DA SCOSSA ELETTRICA
SUL RETRO DI QUESTO PANNELLO SONO DIRET-
TAMENTE ACCESSIBILI CIRCUITI A TENSIONE DI
BEFORE REPLACING INTERNAL FUSES.
ATTENZIONE!
E' RICHIESTO UN GRUPPO DI ASPIRAZIONE ESTERNO.
IN CASO DI CONVOGLIAMENTO DELL'ARIA DI VENTILAZIONE
4500VA (RFB2001)
230Vac 50/60Hz
2500VA (RFB1001)
OFF
0678
SISTEMI
ELETTRONICI
3.2 REAR PANEL CONNECTORS
All transmitter inputs and outputs are allocated on the rear panel. They are:
- The audio channels input sockets on balanced female XLR-type connectors
- The wide-band external processed / stereo or composite signal input on a grounded unbalanced BNC connector
- The frequency limited (20k ÷ 100kHz) auxiliary channel input on a grounded, unbalanced BNC connector
- The LF modulation output for monitoring, RDS external synchronisation or re­broadcasting purpose, BNC-type
- The inverted wired RS232 DB9 female remote serial control port
- The remotr parallel control port, DB9 male type
- The RF antenna connector, N-type
- The hot centre-pin on the "EXTERNAL" BNC input is physically in parallel with the signal + input (pin 3) on the mono/right channel XLR socket. For this reason both connectors cannot be used at the same time.
On the left side of the panel it is located the mains power switch, the power cord and
an earth screw for system earthing in addition to the ground conductor on the cord. The power switch trips if an overcurrent condition should occur.
Please note that the transmitter is usually factory pre-set for 220-240 Vac nominal mains voltage. If requested, 110-120 Vac range must be internally set on the mains tranformer board.
Page 7
PAGE 7
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Note that:
- The hot centre pin of the "EXTERNAL" BNC input (MPX or stereo inout) is physically parallel to the "+ input" signal (pin 3) on the mono/right channel XLR socket. For this reason, you cannot use both connectors at the same time.
On the left side of the panel are located the mains power switch, the power cord and an earth screw for a separated earthing system as well as the ground conductor on the cord. Should an over­current condition take place, the power switch would trip and stop the device.
Page 8
PAGE 8
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
4. TECHNICAL SPECIFICATIONS
- Frequency range: 87.5 ÷ 108 MHz
- Modulation: FM, 75 kHz peak deviation: 180k F3E mono 256kF3E stereo
- Passo di sintesi:10/100 kHz
- Frequency error: <200 Hz
- Frequency drift: <250 Hz in operating temperature <100Hz/year
- RF output power: 300 ÷ 2000W ± 0,5 dB
- Max reflected power: 160W
- Harmonic products RF: <-67 dB, -72dB
- Spurious products RF: <-85 dB (- 95 dB)
- RF output power impedance: 50 ohm
- RF output power connector: 7/16”
- Audio/Mpx input level: -3.5 ÷ +12.5dBm @ ± 75kHz deviation
- Audio/Mpx input impedance:
10k ohm/600 ohm, balanced./unsbalanced
- Common mode input: >50 dB, >60dB tip. (20÷15000 Hz)
- Audio input connectors: XLR female
- Auxiliary/Mpx input level:
-12.5 ÷ +3.5dBm @±7.5 kHz dev.
-24 ÷ -8dBm @±2 kHz dev.
- Aux channel input impedance: 10k ohm
- Mpx and aux input connectors: BNC
- Mpx output level: 0 ÷ +10 dBm @ ±75kHz dev.
- Preenphasis time costant: 0/50/75 µs ±2%
- S/N ratio, mono: >70 dB, 73 tip. (30÷20000Hz)
- S/N ratio, stereo: >66 dB, 68 tip. (30÷20000Hz)
- Modular distortion: <0.05% 0.02% tip. @ 75kHz dev. <0.2% 0.05% tip. @ 150kHz dev. ( limiter threshold>150 kHz)
- Stereo crosstalk: >50 dB with ext. encoder
>60 dB (100÷5000 Hz) >50 dB (30÷15000 Hz) with int. encoder
- Audio channels frequency response: 30 Hz ÷ 15 kHz ±0.1dB
- Attenuazione fuori banda audio: >50 dB @ F19 kHz
- Deviation limiter: adjustable betw. 0 > +7 dB
- Mpx input frequency response: 10 Hz÷100kHz ±0.1dB
- Aux input frequency response: 10÷ 100 kHz ±0.2dB
- I/O liner: Disable RF, Forward power On-the-Air, Allarm. RS232 for monitoring control
- Mains supply requirements: 230 Vca ±15% 50/60 Hz 4800 VA/3600W @ 2000 W output
- Operating temperature range: 0÷35° C recomm.
-10÷45 °C max.
- Dimensions without handless: 483 x 310 x 570 mm rack std. 19” 7 u
- Weight: ca. 47 Kg
SYSTEM AND PROTECTION CONTROLS
- Block against emission on spurious frequencies
- Reflected power and over temperature
- Modulation limiter
>75 dB, 78 tip. (CCIR)
Page 9
PAGE 9
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
I
5. INSTALLATION AND USE
5.1 FOREWORD TO INSTALLATION
Although in most cases no special instruments are required, have skilled personnel install the apparatus. To make best use of the apparatus’s capabilities and prevent damage to the unit, comply with the recommendations throughout this manual.
When in doubt, or if any technical problems should arise during the installation procedure, SOFRATEC strongly recommend the apparatus not be tampered with in any way by unskilled personnel and will be glad to supply qualified after-sale service.
The EB2000 has many features of a hi-fi apparatus and should be installed and audio-wired with the same care, avoiding earth loops as much as possible. When these conditions are met, the transmitter performs superbly.
As a rule, the user should not have access to the inside of the apparatus for normal installation and use. Tampering with the factory settings makes the guarantee null and void and might also affect apparatus’ performance, causing costly damage.
Before proceeding further, make sure that mains voltage corresponds to the factory-set value (usually 220/240 Vac). In case it differs, jumpers must be internally set on the mains supply termination board of the apparatus as described further on the manual. This must be done by skilled technicians.
NO ADJUSTMENT OR INTERNAL PRESETTING IS REQUIRED FOR NORMAL OPERATIONS. THE APPARATUS SHALL BE PROPERLY EARTHED AND BE OPERATED WITH ALL THE COVERS CLOSED TO PREVENT ELECTRICAL HAZARDS IN OPERATION AND FULLY COMPLY WITH CE EMI AND SAFETY REQUIREMENTS.
NEVER TOUCH THE INSIDE OF THE APPARATUS WITHOUT FIRST DISCONNECTING IT FROM THE MAINS. DANGEROUS AC, DC AND RADIO-FREQUENCY VOLTAGES ARE PRESENT INSIDE AND BECOME ACCESSIBLE WHEN THE COVERS ARE RE­MOVED.
——— MAINS VOLTAGE MAY KILL ———
WARNING !
Page 10
PAGE 10
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
5.2 PLACING THE APPARATUS
Install apparatus in a dry, sheltered but well-ventilated room away from dust, moisture, insects and vermin (mice). Place apparatus as close as possible to the antenna to prevent excessive power loss in the cables. If this is not feasible, use antenna cables of suitable cross­section.
Room size shall be such that the apparatus can be placed in an upright position and that technical personnel can easily carry out routine or extraordinary maintenance. The minimum recommended size is 2.5m x 2m, and 2.2m high when there is no other broadcasting or support equipment nearby.
For the best results the operating temperature must be comprised in the +10 ÷ +35 °C range. Higher temperatures up to +45 °C, while allowed in the specifications, are not recommended as they will reduce the life of the apparatus.
This conditions cannot generally be met when the exhaust cooling air is not ducted outside and is fed back into the room. This is even truer if more than one apparatus is installed in the same location. An efficient ventilation system is thus required in the room. Air exchange in the room shall have a minimum flow-rate of 500 metres cubed per hour or more.
If the apparatus is fitted in a rack system, the back door of the rack cannot usually be fixed in place. If a completely closed assembly is needed, a suitable ventilation extraction unit must equip the system. To aid air ducting, an optional flange may be retrofitted on the ventilation outlet to which a duct can be attached to convey hot air outside. In this case remember that the EB2000 internal fans are low-pressure units: some sort of external air extraction blower is than imperative on the exhaust air duct.
Vents in the walls and any other openings shall be fitted with a metal grating to keep rodents out, and with a dust filter. Make absolutely certain that no water can seep through the vents or the air exhaust duct or antenna-cable grommet, and that the floor cannot be flooded during heavy rainfall. If not impedited by proper air filtering, insects in some location may be conveyed in the internal heatsink, accumulating on it and finally obstructing it, causing overtemperature alarm.
Even moisture and/or dust, when contained in the air or in the room in excessive quantity, may cause condensation build-up in the amplifier. When the system is periodically switched on and off, this can trigger destructive electric arcs and short circuits and thus cause damage that is not covered by the guarantee.
Page 11
PAGE 11
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
I
5.3 WIRING INTO THE MAINS
The transmitter is powered by a single-phase line. Mains capacity must be at least 3kVA and the nominal
voltage is 230Vac. In some countries, where 115Vac is the norm, this voltage must be internally set
in the factory or by skilled people before installation. When both the the mains voltages are available, always prefer the higher one, to decrease the power loss on the mains line.
The apparatus is now working in the pre-set mode, delivers power and can be accessed to be
programmed or simply to monitor its functions through the keyboard and the front panel display.
The first request at the turn-on will be entering the password for the required level of authorisation/security. The apparatus is factory pre-set with the first 2 levels disabled: this will permit to set most of the operating parameters, including power, frequency, input levels, clock and date. Some more critical parameters will require the upper 3rd level: be sure to know it if you need this access.
In case the passwords are disabled as factory preset, repeatedly press "ESCAPE" key to access to keyboard functions
THE TRANSMITTER WILL ALWAYS TURN-ON IN THE SAME STATE AS IT WAS IN THE LAST TIME IT WAS TURNED OFF FROM MAINS, I.E. POWER, FREQUENCY AND EVEN ON OR STAND-BY CONDITION. WHEN YOU TURN ON THE REAR PANEL MAINS SWITCH, EVEN IF THE APPARATUS IS JUST FACTORY DELIVERED, BE READY FOR THIS EVENT.
WARNING!
Page 12
PAGE 12
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
5) Turn on the rear panel mains switch, then turn on the front panel on/stand-by switch to operate the transmitter and check that:
- All leds and the display briefly light on and off for the initial check.
- The yellow "STAND-BY" led turns off, while the "ON" green led on the cap of the stand-by switch, turns on.
- The green "Local" led must light up immediately and the upper green “Lock” led must also light up after some seconds, when the frequency is locked.
- When locked the RF power will rapidly increase to the pre-set level in a mild ramped mode
- When the preset power is reached, the "On the air" led will light completely, if the power is set >50W. Till that moment it will turn off and on, signalling that the RF power is on but not correct.
Whilst the power supply regulator accepts a wide input voltage (190 ÷ 250 Vac), operation near the lower
input voltage on high impedance lines must be avoided: if the line drops more than 10 volt at full load, the low line sense circuitry may trigger an oscillating turn-on / turn-off cycle, which is very dangerous. In this cases adopt an external line stabiliser.
To allow nominal 115V mains operation (100 ÷ 130 Vac), some jumpers must be properly set on the
input transformer terminal board, inside the apparatus. To do that, the power cord must be disconnected from the mains, the top cover must be removed and the transformer voltage terminals must be accessed.
5.4 SYSTEM CONNECTION
1) Connect the N-type output connector, marked “RF OUT” to the antenna or successive RF amplifier with top-grade 50-ohm shielded cable. Low-attenuation type cable must be used for antenna connection: in this case we suggest Celflex or similar 1/2" cable. Bigger cables must be connected with smaller section pig-tails, to avoid mechanical stress on the output connector.
2) Connect the LF inputs as required for operation and detailed in the following chapters for various situations. If needed wire the serial and/or parallel remote control I/O ports as required, or skip this step to a subsequent moment.
3) Turn off the mains rear switch and connect the transmitter to the mains and to the ground system.
4) Before turning on the transmitter set if possible frequency and power separately on a dummy load, in order to avoid system problems at the first turn-on of the equipment. Refer to the appropriate programming section of this manual for the procedure, if not known.
Page 13
PAGE 13
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
6) The first task to manage when turning on the apparatus as factory delivered is to enter the passwords.
At least the 3rd (the highest) level must be immediately changed: if any unauthorised people change it or you loose it, there is no way to change it for security reasons and the apparatus may become unmanageable. Gaining again access to the apparatus will require factory reprogramming or changing of the internal CPU. For this reason be sure to write down and keep it immediately in a secure place: there is no way to read it after you have programmed down and confirmed it. For practically any parameters that may require some setting in the field, the 2nd level password is enough and may be used for any standard service requirement. The main purpose of the existence of the 3rd level is a security assurance for the user in case he loses control on the lower password levels and wants to gain it back.
7) If not already done, adjust frequency and RF power as required and check reflected power on the transmitter display. To this aim search for RF power menu and read the corresponding value of direct and reflected output power. For proper operation, the reflected power reading should typically be less than 10% of the direct power value, 100W max. Any higher reading may indicate that the antenna or the output connectors are not properly connected or functioning.
8) Check and/or set clock and data and all transmission parameters as required, i.e. channel sensitivity and deviation, mono/stereo, preemphasis etc. Refer to the appropriate section of the manual.
5.5 LF CONNECTION AND PRESETS
LF wiring and impedance selection
EB2000 supports balanced or unbalanced signals with selectable input impedance. The audio inputs are basically balanced and have selectable 600/10k ohm resistive impedance,
which generally factory pre-set at 10k ohm. They can be connected to the balanced output of a professional mixer or to the unbalanced one of a cheaper unit without appreciable degradation.
Selection of the input impedance is one of the very few pre-sets that may be done only internally.
For this purpose you must gain internal access by removing the upper cover. To avoid any risk, remove mains connection before doing it. 16 Phillips screws must be unscrewed to remove the cover. Be sure to put them back into their place again when done, for EMI/EMC and safety compliance.
Pre-set of input impedance is easily done by accordingly selecting the jumpers JP1 and JP2 located
on the input board just on the rear of the input connectors, as shown on the previous drawing. Impedance selection is silk-screened on the component mask of the board.
LF audio mono or stereo inputs are “XLR” female connectors. They should be connected to the
output of the mixing table, or of any audio-processor that drives it, a balanced coaxial cable connected to pin 3 (+) and pin 2 (-). The cable shield, connected to the ground through of the driving equipment, has to be connected to pin 1.
Page 14
PAGE 14
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
In case of unbalanced drive, input pin 2 shall be short-circuited with ground and shield on pin 1, while the signal shall be available on pin 3. Higher impedance selection, in this case, will be 5 kohm instead of 10 kohm.
With balanced drivings signals, the connecting canles to the audio source may be far longer than 100-m.
Mpx or an externally processed signal, usually an unbalanced one, can be connected to the female BNC connector, marked "MPX", which is internally parallel wired to the "RIGHT" channel connector: for this reason it is not possible to connect signals to these two connectors at the same time. Higher impedance position is 5 kohm in this case too.
If the distance exceeds several tens of metres, use 75-ohm (RG59) or 92-ohm (RG62) cables.
The auxiliary-channel connector is also of the grounded BNC female type. Use 50-ohm (RG58) or 75-ohm (RG59) cables for the connection to the driver. The same applies to the monitor "MODULATION" output, if needed.
Pre-emphasis setting
Low frequency mono and stereo channel signals have to be adequately “pre-emphasised”. Standard preemphasis time constant is 50 and 75µs, the former being usually factory pre-set. Check whether this is correct for your country (it is usually correct for any European country and most of the Pacific and South American areas). It is not correct for USA standards, which require 75µs.
If above correction is needed, simply set it on the "mode" FCC frame of the transmitter menu, which also includes mono/stereo operation and frequency. See appropriate section further on in this manual.
LF input level range, setting and requirements
In the following paragraph we will refer to 0 dBm as the audio signal which produces 1mW on 600 ohm, i.e. a 775 mVrms / 2200 mVpp sine. Irrespective of the impedance and the non-sinus form of the signal, we will continue to assume 0 dBm as a LF signal whose peak is + (or -) 1100 mV.
Page 15
PAGE 15
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
In the same way, when talking of the modulation, we will generally assume 0 dB as the signal which
produces 100% maximum allowed modulation, i.e. 75 kHz deviation.
There is no absolute worldwide standard regarding LF peak level as modulation signal for a transmitter, nor for the mean deviation. Many broadcasters use 0 or +6 dBm as LF peak level for 100% modulation, USA often uses +10 dBm.
Many European countries specify +6dBm for 40 kHz deviation (which is assumed to be a "mean" modulation). This allows 5.5 dB headroom to 75 kHz (max) deviation, i.e. +11.5 dBm for 100% modulation.
A higher level minimise system and ambient noise. A too high level may over-stress the input circuitry of the transmitter, reducing the dynamic distortion-free range over the nominal level (headroom). It may also be costly to produce a broad sygnal with the required quality.
For this reason SOFRATEC recommend, whenever possible, to adopt +6 ÷ +11.5 dBm as nominal peak level for audio modulation purpose.
EB2000 transmitter series allows to set a "variabile" LF level on the main channel/s ranging -3.5 ÷ +12.5 dBm to be set for 100% modulation, with almost no difference in modulation performances, if high quality signal is provided. Even at the higher level, at least +6 dB headroom is additionally allowed: i.e. up to 150 kHz deviation, with no distortion. Obviously this deviation is not allowed by any broadcast standard and the limiter threshold in this case should be set at its maximum to permit undistorted performance.
The auxiliary channel’s level ranges -12 ÷ +4 dBm to produce 10% modulation, i.e. 7.5kHz deviation. Consequently typical input levels for an SCA-type signal (10% max. admissible deviation) are 0.2 ÷ 1.0 V
rms
/ 566 ÷ 2830 mVpp, when the input is set between -11.5 and +2.5 dB. All the same,
an RDS-type signal could be accommodated in the 0.052 ÷ 0.33 V
rms
/ 150 ÷ 930 mVpp level range, to produce the standard peak deviation of 2 kHz, as above. In case a higher deviation is required for RDS (some broadcast authorities set it to 3 or even 4 kHz deviation instead of the standard 2kHz ) a higher signal level preset sensitivity of the auxiliary input, is needed.
Regulating the nominal input level for 0 dB modulation on the transmitter is an easy task. From the proper menu field you can see the variation in real-time, while the input level is being adjusted, in 0,5dB steps. The modulation is reported in kHz as absolute deviation, and in dB with reference to 75kHz.
In this field, the reported deviation includes any other auxiliary signal as pilot tone, when in stereo, and RDS or SCA signals, if used at the moment. To measure only the audio input channel signal, go to the Left/Right level menu.
The auxiliary channel level is equally easy to set, being measured as sensitivity in dB and as deviation in kHz. Remember that, in this case, 0dB corresponds to 7.5kHz deviation, i.e. 10% max allowed total standard modulation. In this way the typical level for RDS is -11.5dB for 2 kHz deviation. This menu field accounts only for deviation due to auxiliary signal. To see the added effect on the total deviation, go to the MPX menu.
Due to the peculiar characteristics of the RDS signal and the measuring sampling, the reading is slow to stabilise in case of sudden level variarions and tends sometimes to slightly flicker in few tenths of a dB. Allow enough time to stabilise and take the higher deviation reported as the right one.
Page 16
PAGE 16
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
The transmitter’s internal limiter is of the peak-clipping type; this means that as soon at it cuts in, modulation distortion increases sharply. For this reason, the modulation signal should be kept under control to prevent intervention of the limiter. Do not over-estimate this problem: occasional action of the limiter is mostly unperceivable.
The cut-in limiter threshold, when enabled, is factory pre-set to +2.5 dB (100 kHz peak value). It may be set from 0 dB (75 kHz) up to +7.1 dB (170 kHz). This threshold value is mostly specified in the various national standards, and tolerance to short over-modulating peaks varies from country to country. Some countries do not permit the user to disable the limiter or change the level. Some countries do not allow the user to disable the limiter or change its threshold. Note that the limiter action begins slightly after the pre-set level, with no action at all till that. The difference between the threshold level and hard clipping is some 0.5dB.
In any case, the modulation peak value that is internationally admitted for FM is 75 kHz for peaks that are not extremely short. For this reason, the limiter’s cut-in threshold should never be too high. It is highly recommended to use an external multi-band limiter to optimise modulation, with higher tolerance for any audio-signal peaks. Such devices momentarily reduce the amplifier circuits’ gain if the threshold is exceeded and prevent severe, significant distortion.
Any external compressor, limiter or audio meter must be frequency compensated with the same time constant of the pre-emphasis to modulate or monitor deviation properly.
Therefore the audio level shall be constantly and correctly monitored and adjusted to prevent, as much as possible, the internal limiter from cutting in. Besides the audio level should be as high as possible, to achieve the best signal/noise ratio on reception.
The tendency to over-process audio signals is common in many local broadcasting stations: some sort of processing is advisable and we recommend using a top grade multiband compressor, but not to compress the signal too much as this impairs the original dynamics.
The audio response of the EB2000 transmitter is extremely flat, without any perceivable loss on low and high audio frequency: for this reason large frequency alterations of the audio signal supplied by using a so-called “frequency equaliser,” are not advisable. An increase of the low and high frequency contents of the audio signal by more than a few dB can cause general degradation of modulation dynamics and improper functioning of the limiter.
Page 17
PAGE 17
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
RS232 port
The RS232 port manages only Tx, Rx and Return data signals, with no handshake. Being the signals "inverted wired", you only need a simple serial cable of the pin-to-pin type, directly wired to the suitable connectors - usually female DB9 or DB25 - which must be connected to a PC port. Besides, you need a male connector - DB9 type - to be wired to the transmitter end.
Parallel REMOTE port
This port accommodates some lines for simple direct control / monitor on a DB9 male connector. They are:
- Pin 1, 5, 8 Ground.
- Pin 2, On The Air: a +12V/10k signals that the transmitter delivers, subtantial RF power,
- Pin 3, Direct power: a signal proportional to direct power is present, with a pseudo square
law. Range is 0-5Vdc / 1k impedance. On EB2000 5V stands for 3000W.
- Pin 6, RF enable: a shorted circuit to ground disables RF. output ≈ +10V/1mA.
- Pin 7, Alarm: logic low signal means alarm. Correct functioning is signalled by +12V/10kΩ.
Maximum current sinking capability <10mA.
Page 18
PAGE 18
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
5.6 OPERATION
Mono Broadcasting, from a monophonic audio source through main mono channel:
1) Wire the “right” (or mono) input connector to the corresponding audio source as described in the "system connection" section. No connection to the "left" channel input is needed. The signal runs through the channel processor and is 15-kHz filtered and pre-emphasised.
2) Select the "MODE" command menu (cf. relevant section on the manual) and select "MONO R" operating mode. Confirm or change also 50 or 75µs pre emphasis as required.
Mono Broadcasting, from a stereophonic audio source through the optional internal
stereo-encoder:
1) Wire both the "left" and “right” input connector to the corresponding audio source as required for stereo transmission. The audio signals will run through the channel processors and will be 15-kHz filtered and pre-emphasised on both channels. The internal stereo-encoder will blend the stereo input source to transmit in mono. In this case the transmitter is already pre set for stereo operation if needed, simply reversing transmission mode to "stereo", inside the aforementioned.
2) Select the "MODE" command menu and select "MONO L+R" operating mode. Confirm or change also 50 or 75µs preemphasis as required.
Note that it is possible, acting on the internal stereo-encoder, to blend the left and right channel or
select only one of them, without changing the modulation sensitivity. Refer to the stereo-encoder description to do that.
Mono or Stereo Broadcasting from a Radio-Link Receiver or an External Encoder:
1) In this case, the signal is already multiplexed and pre-emphasised. Use the “MPX” input. The signal skips the coding and filtering stages and therefore is not pre-emphasised.
2) Select the "MODE" command menu and select the "EXT MPX" operating mode. While it is anyway advisable to select the proper preemphasis time-constant as required in your country, in this position this selection is not influent.
Stereo Broadcasting from a stereophonic audio source through the optional internal
stereo-encoder:
1) Wire the XLR-type modulation input connectors, marked “Left” (channel) and “Right” (channel), to the output of the two channels from the mixer or stereo source. They will be internally 15-kHz filtered and pre-emphasised signal.
Page 19
PAGE 19
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
2) Select the "MODE" command menu and select the "STEREO" operating mode. Confirm or change 50 or 75µs preemphasis as required.
Operation with a RDS or SCA Encoder:
1) Wire the BNC-type “Aux” connector to the output of the RDS or SCA Encoder. If the internal optional stereo-encoder is used, wire the "MODULATION" BNC output to the pilot-tone synchronisation input of the RDS encoder, if present.
2) Select the "AUX" command menu and push "ENTER" to vary the channel sensitivity. Adjust both transmitter sensitivity and/or the level of the external generator for the deviation required, as explained in the previous manual sections. Consider that 0dB modulation reading (not the input level) in this field means 10% total modulation or 7.5kHz deviation, i.e. the standard pre-setting for a SCA auxiliary channel. In the case of RDS, a reading of -11.5dB or 2kHz is the correct value of modulation.
3) Total modulation and deviation may be read on the "MPX" display field, plus any other composite signal available present.
Modulation Adjustment with broadcast signal:
Check the overall modulation level for adequacy, as follows:
1) Select the display menu field "MPX": the total modulation will be displayed, both in dB and as deviation in kHz. An analog moving bar and a digital peak reading are contemporary shown.
2) Send a sufficiently constant musical signal to modulator input, check that the measure hovers around 0 dBm and moves higher during signal peak only and by no more than 1 or 2 dB. For any other reading, adjust the mixer’s “MASTER” volume until the above conditions are obtained. The red “Limiter” alarm LED should never or rarely light up, as this would indicate distortion.
If the limiter is set just above 75 kHz, the red LED will light up above 0dB and the
modulation measured will never show a much greater value. Factory pre-set is 100 kHz (+2.5 dB).
Check of Pilot tone on Stereophonic Transmission:
In case of internal stereo-encoder, no allowance is externally provided to change the pilot tone level,
which is would internally pre-set for 9-10% of modulation, i.e. -21 ÷ -20dB or 7 ÷ 7.5kHz corresponding to the standard deviation of . In case the stereo multiplex signal it is provided by a separate external stereo-encoder, it must be measured in absence of audio modulation and any other auxiliary signal as below described:
Page 20
PAGE 20
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
I
1) Disconnect any signal from the external stereo-encoder input and any RDS or SCA signal.
2) Select the display menu field "MPX" and check the pilot tone, which must be now the only signal avalable. The standard level is that previously stated, i.e. 9-10% or -21 ÷ -20dB, and may be adjusted accordingly on the external stereo-encoder to suit the request.
3) Reconnect any previously disconnected signal as done.
Very low power level transmission:
EB2000 transmitter is not suggested for use at power levels less than 250W and definitely not at
<100 Watt, as with some power and frequency combinations (usually at less than 20 Watt), some sub-harmonic and/or spurious signals may be generated and the power level stability is not so good as at higher power. In addition to that, it may be dangerous to use a transmitter which may generate a very higher power level if improperly set.
Threefase if low power level transmission is imperative, adjust it very carefully and also pre-set
the maximum output power which may be adjusted by main regulation: the software permits to adjust the max RF output level (cfr. relevant section in the manual). Carefully check with a spectrum analyser that the transmitter is workly properly at and just below the operating power.
The installation of the transmitter is thereby completed. Many other monitoring and control
facilities are provided by the internal display and software and are remotely accessible. Navigation through the menu driven software is suggested and encouraged to gain confidence with the options: no extensive training is needed for the most common options. Neverthless some options are hidden for security purpose and always require the password. Read the relevant section of the manual to know all possible functions which are adjustable.
SOFRATEC success in your work, we remind you that we are always available for further
information or to tackle any specific problem.
OPERATION WITHOUT THE ANTENNA OR WITH A FAULTY ANTENNA
CONNECTION MAY CAUSE DEGRADATION AND POSSIBLE DESTRUCTION OF THE FINAL STAGE. THIS FAILURE IS NOT COVERED BY THE GUARANTEE.
WARNING!
Page 21
PAGE 21
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
6. COMMANDS AND PROGRAMMING
The transmitter permits exhaustive control of all transmission parameters and complete programmability and monitoring facilities through the various software controls via the front panel keyboard and display. The same functions are remotely addressable with proper software, which is not included as a standard option other than some simple demo programs.
For a description of remote capability see the proper section on the manual. In this section we will examine the front panel menu-driven operational capability.
6.1 PASSWORD ORGANISATION
The password organisation is set in 3 security levels, each having its own password. A higher level permits to change the lower levels authorisations and passwords.
Each password is composed of 4 alphanumeric characters, including extended capital and lower case ones and several special symbols. We suggest using a wide range of characters as the security level raises, so as to increase the possible combinations. No password is ever shown: it is always
masked by dummy characters as "...." or "****". Nevertheless it may be always changed with the
higher level authorisation. Here is the purpose of each level:
Level 1: Lower security level. It is needed to access to most of the monitoring and control menu
fields, not permitting to alter or programming any operating parameter. It is factory pre­set to "off" state by default, penabling the user navigation through the transmitter's monitoring menu information. SOFRATEC suggest leaving it in its state if a high privacy level is not needed. If set to "on" it will show the default menu field #00 (c.r. menu tree), requiring password for any other information or pre-set. Failure to insert a correct password of any level will impede any other access to the commands for the time-out length (usually 3 minutes). No change of the functioning mode is done in case of incorrect password input. No information is available on the display regarding the transmitter functioning.
Level 2:Service level. This password is needed for any functioning set-up as frequency and
power, sensitivities, clock and date etc. Its use is reserved to service technicians who need wide access to the transmitter presets and functions. While the default factory state is "off", SOFRATEC suggests changing the default state and password immediately at the first power on, to prevent unauthorised people from tampering with the transmitter commands, if the default word is known or the state is set to "off".
Page 22
PAGE 22
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Level 3:Highest security level. It is always "on" by default and resets anyway to "on" after
the display time-out, for security purpose. Its knowledge is deserved only to very
few people and must be immediately entered after set up and kept in a safe place: there is no way to read it after you have set it and confirmed into the transmitter.
This password must be immediately changed at the first pre-set of the apparatus: if any unauthorised people tamper with it or you lose it, there is no way to change it if you do not know the correct word for security reasons and the apparatus may become unmanageable. Gaining again access to the apparatus will require factory reprogramming or changing the internal CPU. For any parameters that may require some setting in the field, the 2nd level password is enough and may be used for any standard service requirement. The main purpose of the existence of the 3rd level is a security assurance for the user if he loses control on the lower level password. Only very few critical parameters, like limiter permission or control require this password, as in some countries this functions are not allowed to be freely chosen.
6.2 FACTORY DEFAULT PASSWORDS
These are the factory default password:
Level 1: P001
Level 2: P002
Level 3: ABCD
For what previously said, be sure to change at least the 3rd and possibly the 2nd level as soon
as you receive and turn on the apparatus.
For security purpose the 3rd level password may be factory changed from the default value
before the transmitter is shipped, in consequence of a specific final customer request.
Page 23
PAGE 23
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
The hierarchical tree of the menu is depicted in the following table, with a small number near the left side of each field for easy reference. In the following pages we will examine each menu field and option.
All of the first column fields require the first level password authorisation to be navigated. Similarly practically all the second column fields require the second level authorisation, as some in the third column. The third level is required only by some functions in this last column.
11
00
01 21 31
02 22 32
03
04
05 25
06
07 27 37
08
09 29 39
12
13 23
14
YES/NO
LEV.1
****
ELAPSED TIME
EXEC SW RESET?
SET PASSWORD
CONF. PASSWORD
T=+25°C
01 JAN 01 17:22
SET DATA & TIME
AUTO POWER DOWN?
23:00-06:00 P=50%
FREQUENCY MODE
VS2 Vs+ Vs-
28V +12.5V -12.7V
FM 100.0 MHz
M= MONO PR= OFF
MPX LIMIT LEVEL
AUTOCONTROL
LEFT level -3.0dB
######### 0 |
SET MPX GAIN
MAX REFL POWER
AUTOCONTROL
SET DIR POWER
AUX L R MPX
Vers. 1.0
DIR POWER 25W
REF POWER 0.0W
MPX 75KHz +7.1dB
ENTER PASSWORD
CODE
SIEL - MILANO - ITALY
Vers. 1.0
SET AUX GAIN
SET MODE, PREENF.
& FREQ.
AUX -11.0dB
######### |
L######## 0 |
R######## 0 |
RIGHT level -4.0dB
X25 S/W
6.3 MENU AND COMMANDS DESCRIPTION
Page 24
PAGE 24
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Navigation through the menu fields is quite straight forward and natural, with the direction keys: The "up" and "down" keys scroll the fields vertically, while the "left" and "right" keys scroll the menu horizzontally . Moving to the right maybe impeded by the password permission, while returning to left is always possible.
The "enter" key changes from scrolling to programming mode, if allowed in the field.
Another push on the "enter" key will confirm the input data. When in program mode, the up and down keys will change the character, while the left and right key will move the cursor on the field. Pushing on the "escape" key will abort the input while repeated escape commands will reset the menu field to the default one (#00).
A local input time-out will automatically escape the command mode resetting input data if this is not confirmed in 60 seconds after the last variation.
Few minutes of experiments will enable most users to gain confidence with control keys and menu and to be able to access all main features of the transmitter, without any previous training.
Anyway it is impossible to discover hidden functions without the proper password permission.
Start menu
The start menu field is the unnumbered one on the top of the menu tree. It is shown only when the apparatus is turned on from the mains or when it reset via software or hardware, so that it will show the software version and the initialization step, when all the leds and the display will be turned on and off for testing purposes. Any subsequent key input will turn this menu field to the next, which requests a valid password code.
Menu #11: Initial Password
This field requests to input a valid password code. When the input is confirmed by the "enter" key, the word will be compared with the memorised passwords table and, if recognised, the corresponding security level will be allowed. If the password is incorrect or the input is terminated by an "escape", the password will be signalised as invalid and the security level allowed will be that actually in memory, i.e. 0 (no permission at all), 1 or 2.
If the security level is already "off" for the 1st and the 2nd level f actory pre-set,as there is no need to input any password to freely navigate in the menu tree and to set the essential operating parameters.
When the password is recognised as valid and the corresponding level is displayed, press on escape key will turn on the default menu field #00.
ENTER PASSWORD
....
Page 25
PAGE 25
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Menu #00: Default Message
This field shows the default message and the software release. It is the field that will be initially
displayed or to which pressing repeaterly you can get back, after the "escape" key.
If authorised by the 3rd level permission, going to the command mode and by pushing "enter", will change the first row of this field with a custom 20 characters long message e.g. the following organisation name:
Menu #01: Direct & Reflected Power
This field shows the direct and reflected power actually delivered.
Going to the command mode, with the 2nd level password authorisation, will allow to set a new direct
RF output power. See menu #21.
Menu #02: Multiplex Signal Level (Output Modulation)
This field shows the present peak modulation in dB referred to 75kHz and as deviation in kHz. A pseudo-analog moving bar will contemporary change according to the modulation, leaving a peak mark at its end for 1 or 2 seconds. A vertical bar (|) on this line marks the 0dB position.
Command mode, with the 2nd level password authorization, permits to set the LF input channel sensitivity. See menu #22.
Right key instead permits to access to limiter setup and threshold. See menu #32.
MPX 75.0kHz + 0.0dB ############# O|
NORTH-WEST RADIO X25 SW rev. 1.0
Dir Power: 1002 W Refl Power: 26 W
SOFRATEC - NICE -FRANCE X25 SW rev. 1.0
Page 26
PAGE 26
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Menu #03: Left & Right Signal Level in dB
This field shows the present left and right peak modulation in dB referred to 75kHz.
The reading is adequately accurate with real audio signals. Some steady state test tone especially at very low audio frequency may beat with the discrete ADC conversion sometimes producing reading uncertainty (aliasing). In this case the MPX level reading will anyway produce correct overall modulation measure.
Menu #04: Left & Right Signal Level as analog moving bar
This field shows the present left and right peak modulation as two moving bars. A vertical line marks 0dB position and the same considerations as in the previous menu are still valid.
Menu #05: Auxiliary Signal Level Modulation (SCA, or RDS)
This deviation field shows the present modulation due to an auxiliary SCA or RDS signal in kHz, and a peak level expressed in dB referred to 7.5kHz 10% of max peak modulation. Usual level for SCA signal is instead, higher and tipically 0dB (7.5kHz) . The standard modulation of the RDS usual level is "kHz i:e: - 11,5 dB.
Command mode, with the 2nd level password authorization, permits to set auxiliary input channel sensitivity. See menu #25.
LEFT level - 3.0dB RIGHT level - 4.5dB
L########### O | R######### O |
AUX 2.0kHz -11.2dB #########O |
Page 27
PAGE 27
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Menu #06: Aux, Left, Right and Mpx level in dB
This field contemporary summarisesthepresent modulation in dB of the auxiliary, left, right and
multiplex signal as seen in their own menu fields - AUX - L - R - MPX
Menu #08: Internal Voltages
This field shows the internal regulated voltages. In the EB2000 Vs2 is comprised between +18 and +22V, depending on factory adjustment. Vs+ is +12.5 ±0.3V, Vs- is -13.0V (+1/-3V). A marked difference from these values, may indicate mis-fuctioning.
Menu #09: Temperature, Data and Clock
This field shows the internal temperature, the present data and clock. To set data and clock it is required to goto the command mode, with the 2nd level password authorisation. See menu #29.
Two temperature sensors read the room (A) and the output stage heatsink (H) temperature. The room temperature is really that of the exhaust ventilation air and it is taken just behind the front panel. It is usually 2 - 3 °C higher than the external temperature at full output power: i.e. nearly +47 °C assuming an external temperature of +45 °C (the maximum allowed).
The heatsink temperature is usually 10 -13°C higher than the room temperature full power.
Being the maximum allowed temperature limit +45°C, the transmitter progressively reduces its output power when the ambient temperature is reported higher than 55°C or the heathsink is higher than 65°C. There is 5°C overtemperature range in which the equipment is allowed to work at reduced performance. Besides, the equipment may reliably work in an ambient which is even 10°C higher than the maximum nominal range, at less than maximum output power or for reduced lengths of time.
Consider that the higher the ambient temperature, the lower the MTBF. As rule of thumb the life is halved each 10° C the temperature is increased. Assuming 10 years operating life at +25°C, which is not unrealistic, it may become 2.5 years at +45°C.
Vs2 Vs+ Vs­+20.2V +12.4V -12.9V
AUX L R MPX
-11.2 -3.0 -4.5 +0.0
T(A/H): +30°C +40°C 01 JAN 02 17:22:10
Page 28
PAGE 28
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Menu #12: Elapsed Time
This field shows the elapsed time and whether the transmitter is on the air or in stand-by with
the mains applied. There is no way to change the reading.
Menu #13: Password Management
This field shows the password status and allows the user to change the code and/or the status in command mode, when in possession of the necessary level authorisation for that level or a for higher one. No code is ever shown and no access is permitted to a level higher than that the current authorisation.
If the password is unknown, lost or if it was undeliberately changed it, it is possible to changer level status and code when in possession of the higher password. In this case the lower level passwords be changed and confirmed; no possibility still being to know was what the old password. This means that it is always possible to change the 1st or 2nd level passwords, even if they are unknown, if respectively the 2nd or 3rd level password are correctly entered.
If the password or the status is changed, it is always required to confirm the correct password for that level.In case a lower password permission is actually entered in regard to the needed action, it is possible to input the higher level passwords either performing a software reset, if permitted, or turning off and on the mains voltage through the rear mains switch or an external switch.
The 3rd level authorisation, when set, will stay valid only till a display time-out is performed, i.e. usually 3 minutes after the last command. Simply navigating through the menu or performing some action will extend the time-out.
If the password status is set to on for the level 1, a hung-up follows after the time-out. This is intentional to prevent unauthorised people from browsing the transmitter parameter. Transmitter performance will be unaffected by this condition. Any attempt to access the transmitter will cause the password request: if an invalid password is entered, it needs to wait for the time-out to permit a new attempt or to remove the mains power to the apparatus, causing a hardware reset. Even in this case, the first request will be a valid password input.
ELAPSED TIME 000356 HOURS
PASSWORD LEVEL X code=**** status=OFF
Page 29
PAGE 29
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Menu #14: Software Reset
This field permits to execute a software reset if in possession at least of level 1 password authorisation. The main purpose of this reset is permitting to input a new password level; its action is similar to turning off and on the mains to the apparatus. A software reset will lead to a small interruption of the RF output power which will be re-established in 1-2 seconds, while lock on frequency will not be lost. No transmission or sensitivity parameter is lost in consequence of software or hardware reset.
To execute a software reset the "ENTER" key must be pressed twice
Menu #21: Output Power Set
This field derives from #01, in command mode. The direct power value blinks and acting on the up and down keys the numeric value varies. The output power will vary in real time. Confirming the final value with an "enter", will write the new setting in the enduring memory of the apparatus. Escaping will abort the change. A local time-out will automatically delete the input if the input it self not confirmed in 30s from the last change.
Menu #22: Multiplex, Left & Right Input Level Set
This field in command mode, with the 2nd level password authorisation, permits to set LF input channels sensitivity, i.e. multiplex, left and right channel. Keep in mind that the multiplex and the right signals share the same channel and the sensitivity is set to the same value for both right (or multiplex) and left channels, with a differential error <0.2dB at any level. Allowed range is -3.5 ÷ +12.5 dBm.
The first line of the display shows the actual modulation, while the bottom line shows the input level for 100% modulation. Increasing the nominal input level will accordingly decrease the modulation, if the modulatotion signal is constant.
NO
Dir Power: 990 W Refl Power: 22 W
MPX 75.0kHz + 0.0dB Nom.input = + 6.0dBm
EXEC SOFTWARE RESET?
Page 30
PAGE 30
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Menu #23: Password Confirmation
This field is displayed when password code or mode is changed on menu #13. It requires to input the same password code as in the current level which is to be changed. Failure to do so will show the following message:
This display stops input mode for 5 second and than permits to exit (and possibly to try again) with the escape key.
Menu #25: Auxiliary channel Input Level Set
This field in command mode, with the 2nd level password authorisation, permits to set the auxiliary channels input sensitivity. Allowed range is -12 ÷ +4 dBm to produce 10% modulation, i.e. 7.5kHz deviation or 0dB in the upper line of the display.
Menu #27: Mode, Preemphasis and Frequency Set
In this field it is possible to set the transmission "modes" (MONO R, STEREO, MONO L+R, EXT MPX), the preemphasis time-constant (0, 25, 50 & 75 µs) and the frequency in step of 10 or 100kHz as pre-set on menu #37. The access to this last menu is performed directly from the main frequency menu #07, pressing the "right" key.
Left and right keys change the input fields whilst the up and down keys change the various options or increase/decrease the frequency.
CONFIRM PASSWORD
....
INVALID PASSWORD!
....
AUX 2.0kHz -11.2dB Nom.input = + 0.0dBm
STEREO PR=50us FM 102.43 MHz
Page 31
PAGE 31
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Menu #29: Date and Time Set
This field is the command mode display of menu #09, with the 2nd level password authorisation and
permits to set date and time.
As in the previous menu, the left and right keys change the input fields while the up and down keys
increase/decrease the date and time.
Menu #31: Maximum Reflected Power Set
This field permits to set the maximum reflected power level. Default value is nearly 90W and in any
case this power is hardware limited to 100/120W for security reason.
Auto Control on the lower line is not yet operative and could be absent in other software releases.
Menu #32: Limiter Set
This field, with the 2nd level authorisation, permits to set the limiter action. The right/left keys toggle
the limiter on and off. The up/down keys vary the threshold level.
Auto Control on the lower line is not operative in some software releases. When it is, it will dynamically reduce the input sensitivity to allow distorsionless limiting if pre-set to ON. Even in this case it will be wise not to exceed the limiter threshold to avoid "pumping" effect on the modulation.
Refl.Pw limit 87 W Auto Control OFF
T(A/H): +30°C +36°C 01 JAN 02 17:22:10
MPX limit + 7.1dB Auto Control OFF
Page 32
PAGE 32
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Menu #37: Frequency mode
This field, with the 3rd level authorisation, permits to set the frequency step variation between
100 and 10kHz.
Menu #39: Power-down setup
This field, with the 2nd level authorisation, permits to preset the "power-down" mode.
If this mode is on, the output power will be automatically decreased to the pre-set percentage in the time period set on the bottom line. The scaled power is approximate and must be tested and/or adjusted before final setup, if critical.
FREQUENCY MODE 100kHz / STEP
AUTO POWER-DOWN OFF 23:00--06:00 P=50%
Page 33
PAGE 33
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
7. SERVICE AND MAINTENANCE
Since the EB2000 is forced-air cooled by an internal low-pressure fan, it is subjected to clogging
by dust.
It is therefore recommended to install the apparatus in rooms that are not excessively dusty and sheltered from dust. Place apparatus above floor level on a stable stand/rack, in such a way to permit good ventilation. Depending on the environment it is suggested to internally clean the equipment with a soft brush or compressed air at fixed time intervals, from 6 to 12 months.
Other than this, because of the high-quality materials used in their manufacture, if it is installed as set forth under “INSTALLATION AND USE,” it will not require special maintenance for quite some time.
After a few years of continuous service, it is recommended that the apparatus be overhauled in the factory or in a specialised laboratory, where the characteristics can be checked against the initial ones and re-calibration can be done when needed.
It is especially important that the power supply be over-hauled when the apparatus have been working at high temperatures, over 30 / 35 °C.
Never change the internal calibrations to avoid altering the transmitter declared perform­ances.
Page 34
PAGE 34
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
8. GUARANTEE
Like all SOFRATEC's solid state equipment, this transmitter carries a one-year guarantee on all their components with the exclusion of the final RF power transistor, which may be damaged by faulty output connections.
This guarantee is null and void if the apparatus is tampered with or if failure is due to improper use, wrong installation or external causes, such as mains overvoltage or excessive moisture in the environment.
This guarantee covers work done exclusively in our laboratories and in those of our agreed representatives.
The goods shall be delivered carriage prepaid to the laboratory and shall be returned freight forward.
This guarantee does not cover any consequential damage due to non-operation or faulty operation.
Page 35
PAGE 35
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
I
9. SERVICE MANUAL
9.1 INTERNAL DESCRIPTION
The EB2000 transmitter comprise several internal modules, as can be seen in the drawing “General
view” and in the "General wiring diagram", both comprised in this manual:
-The CPU controller and display board
-The LF and RF control main-board
-The stereo-encoder module (optional)
-The FM synthesiser module
-The RF driver amplifier
-The RF power amplifier array
-The main regulated power supply
-The auxiliary regulated power supply
For the detailed description of each module on the following pages, always refer to the
corresponding electrical diagram, in the relevant section of the manual.
THIS SECTION IS ONLY AIMED TO GENERAL EXPLANATION, REFERENCE AND SERVICE PURPOSE BY SKILLED PERSONNEL. AS EXPLAINED IN THE PREVIOUS SECTIONS, INTERNAL ADJUSTMENTS ARE NOT REQUIRED DURING NORMAL OPERATION. TAMPERING WITH INTERNAL SETTINGS VOIDS THE WARRANTY, MAY HARM THE APPARATUS AND JEOPARDIZE THE GUARANTEED PERFORMANCE. COMPONENT VALUES SHOWN MAY VARY FOR PRODUCTION REQUIREMENTS.
DUE TO THE TECHNOLOGY USED, MOST MODULES AND ESPECIALLY THOSE IN SMT ARE NOT INTENDED TO BE REPAIRED IN CASE OF FAILURE AND MUST BE REPLACED WITH NEW ONES.
WARNING!
Page 36
PAGE 36
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
THE CPU CONTROLLER AND DISPLAY
This circuit board is basically simple. It contains the CPU, the keyboard and few other circuits
which we will briefly discuss.
The CPU has 3 digital 8-bit ports and an analog one. This latter is the interface with the analog signals that must be measured in the transmitter. A fast peak rectifier built around IC4 drives one of these analog lines. All audio or lf modulation plus some steady state signals are multiplexed to its input by IC3, so requiring only one peak rectifier and increasing the number of the analog channels. One analog channel reads the internal temperature through the TR3 sensor, while a second temperature input is performed by the line AN3, for the heatsink temperature sensing.
The simple specialised IC6 performs clock and date functions as a stand-alone unit, backed­up by a battery which keeps circuit active for a long time when power is off.
The keyboard switch array is sequentially scanned one hundred times in a second to determine if a key was pushed. IC5, a serial to parallel converter, drives the front-panel leds and the display backlighting with TR2.
The alphanumeric display is a separate module, connected to the board by a small flat-cable. 11 digital lines from the CPU drive this module. The internal board trimmer RT1 regulates the LCD contrast and may be used to change it for different situations. A separate power supply current for the backlight leds is provided by R41 and R42: these resistors become quite hot when the display is full on and their heat somenow influence the internal temperature read by TR3.
No other regulation is provided on the board. The precision of the measurements is guaranteed by design by the precision of the components and the reference voltage source IC1.
Page 37
PAGE 37
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
THE LF AND RF CONTROL AND PROCESS MAIN-BOARD
This is the most complex board in the transmitter and supports the LF input processing, with level adjustment, audio-pass filtering and limiting. It also carries the RF control section and the I/O interfaces and interconnects the various transmitter modules with flat-cables.
Its electrical diagram is splitted in two sheets for clarity purpose: they will be examined in sequence.
In the first diagram sheet are allocated the I/O interfaces, both the audio and the digital ports and the analog RF control. Let's start to briefly consider each block diagram.
In the upper left side of the diagram are located the audio channels amplifier/buffers made with 6 op-amp sections of IC1 and IC2. Two impedance selector jumpers for the audio channels leads the pack and a protection network made by resistors and diodes protects the inputs from occasional static discharges, as required for CE compliance. Four unity-gain active buffers follow and then two balanced to unbalanced signal converters, which drive the electronic attenuator in the 2nd sheet.
The last op-amp in IC2 (d), amplifier the auxiliary channel input with a -0.1dB upper corner band >>200 kHz and drives the third channel of the electronic attenuator.
On the lower left of the diagram are the RS232 interface (IC5) and the parallel remote I/O active interface with its protection network, built around TR1, TR2 and TR3. A wired or pull-up makes the logic levels <1V as 0 and 10-12V for 1.
On the lower right section of the diagram it is located the RF power controller.
The RF direct and reflected power signals coming from the output directional coupler are amplified by IC3 in two symmetrical circuits.
The direct-power control circuit, built around IC4a continuously drives the RF output stage gain, varying the supply voltage to the RF driver transistor and the regulated voltage of the output transistor. The reflected-power limiting circuit IC4b only acts on the same loop when the IC3b output voltage is greater than the threshold set by the voltage on the R49/R50 network. A third and fourth section of IC4 filter and buffer the signal coming from the CPU and set the reference level for the output power loop. TR4 disable the RF output when the synthesiser is not locked on the correct frequency.
In the upper right section of the sheet is shown the control bus connector to the CPU, which carries the digital control lines on the lower pins and the analog lines on the upper ones. From this connector comes the power supply too: only +12.5V and -12.5V are used in the board.
Let's now go to the second sheet of this diagram.
Beginning from the upper left side, we find IC8, which makes a 3-channel digitally controlled attenuator. It separately manages left, right and auxiliary channel, while the external multiplex signal is processed in the same channel as the right one. 3 buffers/amplifier follow each channel: IC7a, IC8a and IC12a. The output of the first two amplifiers drive the pre-emphasis stages, whose time constants can be digitally set at 0, 50 and 75µs, through the analog gates of IC9. A limiter stage follows, built around D8 and D9 diodes acting as clippers. By varying the limiter’s reference voltage driven by the CPU though IC13a, the limiter threshold level +Vl & -Vl can be adjusted. RT4, if present, impose a ceiling to the limiter.
Page 38
PAGE 38
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
The signal is then sent to the stereo-encoder circuit’s input sections if present. In the mean time, the signal on the mono right channel path is sent to a low-pass filter, consisting of the section built around IC10 and IC11, which attenuates the frequencies above 15 kHz, for operation in mono.
The switch IC14 selects the signal issuing from the non-pre-emphasised input section through R124 or from the pre-emphasis-and-filter section through R128 or from the stereo­encoder through R131. IC12b buffers the chosen signal and mix it with that issuing from the auxiliary channel. When required the diode D17 further limits the resulting total signal. The latter is then sent to the FM modulating/exciting circuit via IC12c buffer circuit and adjusted in level by RT6 as required. A separate section of IC12 separately buffers the modulation signal for monitoring purpose, and sends it to the modulation output connector.IC15 deserialise the digital signal sent by the CPU to control the transmission channels with IC14 and preemphasis action with IC9. Two output lines from IC15 are used to latch the remote output lines "Failure" and "On the air".
THE STEREO-ENCODER MODULE
The encoding circuit uses an 8-step switching technique, which ensures excellent perfor­mance with a relatively simple circuit. Besides, by this technique, the first harmonics that are associated with the resulting stereo multiplex signal are the 7th and 9th (266 and 342 kHz); this simplifies the design of the low-pass filter on this signal.
The audio signal is filtered beyond 15 kHz by the two precision active low-pass filters built around IC1 ÷ IC4. It is then buffered by IC3d and IC4c and applied to the encoding circuit comprised in IC8. Another higher frequency low-pass filter follows to remove higher order harmonic products. This filter too is made with highly precise active circuitry built around IC5 and IC6a, b. The latter section (c) of IC6 performs phase equalisation. The four analog switches comprised in IC7 permit to select the mono or the stereo-encoded signal and to slightly vary the encoder gain to adjust for the 90% audio modulation in stereo vs. 100% in mono. Two jumpers on BD1 permit to select either Left or Right or Left+Right channel for mono operation, with no output level change. As factory configured, both jumpers are installed, to mix Left and Right channel for "MONO L+R" operation.
Circuits IC10, IC11 make the encoder’s time base; IC9 synthesizes the 19kHz pilot frequency, which is filtered and buffered by IC5a. A separate 1Vpp output is provided on J2 to drive carrier synchronisation on a possible external RDS generator.
Page 39
PAGE 39
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
THE SYNTHESISED OSCILLATOR
It’s a classical phase-locked-loop circuit with 10-kHz step synthesis across the entire FM band.
The very low-noise, fundamental-frequency VCO consists of a FET-oscillator transistor TR5, modulated by the varactor diode set D4÷D7, which also sets the operating frequency. The circuit is sensitivity compensated vs. carrier frequency variation so that its modulation gain varies less then 0.5 dB across the entire operating range.
Modulation distortion is typically lower than 0.03% with over 90 dB S/N ratio in the mono mode in the 30 - 20,000 Hz band.
The RF signal is buffered and amplified by three successive transistors TR6 ÷ TR8, from which is derived the feedback signal to the PLL and the drive signal for the output RF stage. This latter is composed by two small mosfet transistors TR9 and TR10 and attains some 900 mW output level (+29 dBm) over the full FM range. To correctly operate TR9 and TR10 require a gate bias voltage, which is factory pre-set by RT1.
The digital PLL circuit is entirely comprised in IC2, whose frequency reference is derived from a highly precise temperature compensated oscillator (TCXO1) running at 12.8MHz.
To correctly operate on the chosen frequency, IC2 must be serially programmed with complex data. This task is done by the transmitter CPU through 3 control lines.
IC1 either performs loop filtering from IC2 frequency comparator output to the varactor diodes and lock detection. Note that bias voltage is removed from output transistors through TR4 and TR3 to turn­off RF when the PLL is not locked on the right frequency. The control loop was designed to ensure that cross-talk added to stereo-composite signal is below -55 dB at 30 Hz, and is virtually not influent at just slightly higher frequencies.
THE RF DRIVER AMPLIFIER
This stage is designed with one high gain mosfet RF power transistor, which has some 17 dB gain, in a broadband design.
A resistive input attenuator (R2, R3, R4), when present, enhances matching with the previous stage and contributes to insulate the two stages. A broadband matching network feeds the transistor gate and and the one follows the transistor drain.
The available output power is well over 25W on the whole FM range, with 28V power supply. To limit that power up to nearly 20W, a lower power supply voltage is applied, usually 20V.
Page 40
PAGE 40
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
The transistor gate is biased by zener network and a resistive trimmer which adjusts the idle current of the transistor. RT1 is usually set so that to provide some 200mA drain current, with +12Vdc control voltage applied and no RF input. Varying the control voltage towards a negative supply progressively disables the amplifier transistor, so effectively acting as an AGC input.
In fact the power management circuit, in a closed loop driven by the output sense circuitry, varies this voltage. This will accordingly vary the output power to obtain the pre-set value and cope with alarm and start-up conditions.
The low-pass section and the directional coupler circuit shown in the electrical diagram and allowed in the board are not always present, because they are not needed for the driver.
THE RF POWER AMPLIFIER ARRAY
This stage is designed with two 500W amplifier modules, coupled with an input splitter and an output combiner. A low-pass in incorporated in the latter togheter with a directional coupler.
The whole assembly is contained in a fully screened box, which may be accessed from the bottom of the transmitter, removing the bottom cover. A quick description of each stage follows.
The input RF power splitter
The purpose of this simple board is mainly to divide the input RF drive power in two identical signals, one for each power amplifier module, providing a good insulation between each output port (>20 dB, typ. 23 dB minimum on the whole FM band).
This is done by a Wilkinson type printed coupler, followed by the balancing resistor array R21 ÷ R24.
A directional coupler senses the input RF level and RT1 is regulated to provide the overdrive protection circuit trip at the right maximum input level. The board supports also the direct (or forward) and reflected detector sensitivity trimmers, whose input comes from the output board.
Two additional lines support the RF module bias (or AGC) line and the temperature sensing PTC thermistor on the heatsink.
Page 41
PAGE 41
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
The RF power amplifier modules
These modules are built around a couple of "Gemini type" Mos-fet transistors each one forming
a 300W push-pull amplifier.
Discrete Wilkinson-type couplers equip both the input and the output module section, doing the job of dividing and recombining the input and output signals, providing a suitable insulation between the transistors.
A small balancing resistor R1 is mounted on the input splitter, while a much bigger resistor R14 is mounted in the output combiner.
A group of C, R and L RF decoupler and dampening components are mounted on the positive supply line of each amplifier, plus a small value resistor, R12 and R13, for possible separate current detection of each supply leg.
The gate bias is separately adjusted through R15 and R16 on each section. Do not tamper the factory bias preset values!The full power output of the whole module exceeds 600W, to provide some room for coupling losses on the combining stages of higher power amplifiers, like the same EB2000.
The output RF power combiner, LPF and coupler
This module is symmetric to the input power splitter and is another printed Wilkinson coupler, whose power management capability is obviously much higher than the input board. In this case the power balancing resistors are high power devices, whose centre connection is referred to ground through an inductor, which discharges any static electricity on the antenna up to a relevant amount of power.
The power combiner is followed by a printed low-pass filter, which attenuates the harmonic products generated by the amplifiers.
3 directional sample lines derive two rectified voltages proportional to the direct and reflected output power and a RF signal for external monitoring purposes.
Page 42
PAGE 42
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
THE MAIN POWER SUPPLY REGULATOR
This module performs an efficient regulation of the raw dc input, nominally 140V ±15%
to that much lower, needed by the RF output power modules, nominally 48V. Being its efficiency very high, very little heat is produced in the regulation process. The nominal current capability of the regulator is much higher than requested, and approaches 70A @ 48V.
A control I/O connector on an upper daughter board permits a remote control of the regulator by the apparatus controller, i.e. output on/stand-by, current and voltage monitoring, status prompting and alert.
The regulated voltage is dynamically varied by the ALC control with the output power, to maintain high efficiency at reduced power levels, proportionally decreasing the generated heat amount. The voltage varies in the range 30 to 48V, the higher one being measurable only when the apparatus is set at the maximum output power.
A fast 80A semiconductor-grade protection fuse is screwed on the board: it may be fused by the crowbar protection in case of switching transistor damage. If this happens a first attempt to replace the fuse may be accomplished, after having verified the integrity of the power transistors. Usually something is broken so causing the fuse blow-up.
Reparation of this module in the field is very difficult if any component other than the fuse and/or a power transistor failed. It is suggested to substitute the module with a new one and send back the damaged unit to the factory for inspection and possible reparation.
Page 43
PAGE 43
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
THE AUXILIARY POWER SUPPLY REGULATOR
Even this small power supply regulator is a high-efficiency, low-voltage switch-mode type. Its input
is derived by the main nominally regulated +48V.
The main switch-mode regulator is buit around IC1, which controls the conduction duty-cycle of its internal series-pass power MOSFET to obtain a 28.0 ±0.1VCd regulated voltage. The oscillation frequency is fixed, nearly 100 kHz.
L1 and C26/C27 form the main integration cell, which averages the pulsed voltage at IC1 output. A second filtering cell, L2, C28/C29 further removes high frequency noise contents from the main regulated output.
A 30V zener diode, D8, is in parallel with the main regulated output, for safety purpose. Should the internal switch transistor fail short, D8 would break-down blowing the series input fuse on the board, avoiding more costly overvoltage damages to the rest of the transmitter. It is imperative not to pass the nominal +28.0V (+0.1V max) on the main regulated output, to avoid overstress on this component and consequent failure. Neverthless in this apparatus, the main regulated voltage is usually set to +20V and limited to 22-23V max, as needed by the RF driver amplifier to deliver 18 to 20W.
Another lower power switch-mode IC regulator derives the auxiliary regulated +12.5V voltage (±0.5V/0.5A, average) and a losely regulated -12.5 ±1V.
The efficiency of the whole circuitry is very high and manages a substantial amount of power versus mains voltage changes, dissipating little energy, so keeping overall temperature low with no extensive heatsinking, required by linear regulators.
Page 44
PAGE 44
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
EXB2000 TRANSMITTER - FRONT & TOP ASSEMBLY VIEW
Page 45
PAGE 45
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
EB2000 TRANSMITTER - REAR INTERNAL VIEW
Page 46
PAGE 46
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
EB2000 TRANSMITTER - GENERAL ELECTRICAL DIAGRAM
Page 47
PAGE 47
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
EB2000 TRANSMITTER - EXCITER ASSEMBLY ELECTRICAL DIAGRAM
Page 48
PAGE 48
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
COMPONENT LAYOUT
SEXC25AL5 -- AUXILIARY POWER REGULATOR BOARD
ELECTRICAL DIAGRAM
Page 49
PAGE 49
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SEXC25CON -- CPU CONTROLLER & DISPLAY BOARD
ELECTRICAL DIAGRAM
Page 50
PAGE 50
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SOLDER SIDE
COMPONENT SIDE
SEXC25CON - CPU CONTROLLER & DISPLAY BOARD
COMPONENTS LAYOUT
Page 51
PAGE 51
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
COMPONENT LAYOUT
SEXC1K05IN - INPUT & INTERFACE BOARD
ELECTRICAL DIAGRAM
Page 52
PAGE 52
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
COMPONENTS MAY VARY DUE TO PRODUCTION ADJUSTMENTS
SEXC25MB - MAINBOARD / I/O & RF CONTROL SECTION
ELECTRICAL DIAGRAM - 1 of 2
Page 53
PAGE 53
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SEXC25MB - MAINBOARD / LF PROCESS SECTION
ELECTRICAL DIAGRAM - 2 of 2
Page 54
PAGE 54
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SEXC25MB - MAINBOARD
COMPONENT LAYOUT
Page 55
PAGE 55
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SEXC23COD2 - STEREO ENCODER BOARD -
ELECTRICAL DIAGRAM
Page 56
PAGE 56
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SEXC23COD2 - STEREO ENCODER BOARD
COMPONENT LAYOUT
Page 57
PAGE 57
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
COMPONENTS MAY VARY DUE TO PRODUCTION ADJUSTMENTS
SEXC25MOD - FM EXCITER BOARD -
ELECTRICAL DIAGRAM
Page 58
PAGE 58
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SEXC25MOD - FM EXCITER BOARD
COMPONENT LAYOUT
Page 59
PAGE 59
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
ASEXC25AM5 - FM 25W POWER AMPLIFIER
ELECTRICAL DIAGRAM
Page 60
PAGE 60
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
ASEXC25AM5 - FM 25W POWER AMPLIFIER
COMPONENT LAYOUT
Page 61
PAGE 61
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
ASRFB2K0RF - 2KW AMPLIFIER ASSEMBLY
- ELECTRICAL DIAGRAM
Page 62
PAGE 62
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SRFB1K0LP - 2-PORT RF OUTPUT COMBINER & LPF
ELECTRICAL DIAGRAM
Page 63
PAGE 63
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SRFB500W - 500W AMPLIFIER MODULE
ELECTRICAL DIAGRAM
Page 64
PAGE 64
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SRFB500W - 500W AMPLIFIER MODULE
COMPONENT LAYOUT
Page 65
PAGE 65
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SRFB1K5ALM - 48V/70A SMPS REGULATOR
ELECTRICAL DIAGRAM - POWER SECTION
Page 66
PAGE 66
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SRFB1K5ALM - 48V/70A SMPS REGULATOR
ELECTRICAL DIAGRAM - CONTROL SECTION
Page 67
PAGE 67
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SRFB1K5ALM - 48V/70A SMPS REGULATOR
COMPONENT LAYOUT - POWER SECTION
Page 68
PAGE 68
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
SRFB1K5ALM - 48V/70A SMPS REGULATOR
COMPONENT LAYOUT - CONTROL SECTION
Page 69
PAGE 69
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Page 70
PAGE 70
SOFRATEC BROADCAST EQUIPMENT WWW.sofratec.com - e-mail : info@sofratec.com Tel: +33 4 93 01 99 99 Fax: +33 4 93 01 99 71
EB 2000 USER AND MAINTENANCE MANUAL
Loading...