Sofradir ATOM 1024-73L, 1024-20L, 1024-20C, 1024-20G, 1024-40L User Manual

...
Page 1
TM
ATOM
1024 User Manual
TM
ATOM is a trademark of Sofradir-EC Inc.
Page 1
Page 2
Revision 1.0.28
March 2013
© Sofradir EC, Incorporated
A Sofradir Group Company
www.Sofradir-EC.com
This manual and the software described in it are copyrighted with all rights reserved. This manual and the software may not be copied, in whole or in part, except as pertains to the normal use of the product, such as backup copies, without written permission from Sofradir-EC Incorporated. The same copyright and restrictive notices must be duplicated on any authorized copies.
Page 2
Page 3
ATOM 1024 USER MANUAL ................................................................................................................................................. 1
1 ABOUT ......................................................................................................................................................................... 6
1.1 TRADEMARKS ................................................................................................................................................................... 6
1.2 LICENSING ....................................................................................................................................................................... 6
1.3 WARNINGS ...................................................................................................................................................................... 6
2 MODEL OVERVIEW ....................................................................................................................................................... 8
3 GETTING STARTED ....................................................................................................................................................... 9
3.1 UNPACKING ..................................................................................................................................................................... 9
3.2 WHAT YOU NEED TO GET STARTED ........................................................................................................................................ 9
3.2.1 ATOM 1024 SW Support Disk contents .............................................................................................................. 10
3.2.2 Additional Documents ........................................................................................................................................ 10
3.2.3 Frame Grabber support notes ............................................................................................................................ 10
3.3 FEATURES ...................................................................................................................................................................... 10
4 HARDWARE OVERVIEW ............................................................................................................................................. 11
4.1 CAMERA PANEL DESCRIPTION ........................................................................................................................................... 11
4.1.1 Camera Link ....................................................................................................................................................... 11
4.1.2 GigE .................................................................................................................................................................... 12
4.1.3 LVTTL .................................................................................................................................................................. 13
4.1.4 Continuous Zoom ............................................................................................................................................... 14
4.2 POWER INPUT JACK ......................................................................................................................................................... 15
4.2.1 Camera Link & GigE power input ....................................................................................................................... 15
4.2.2 LVTTL power input.............................................................................................................................................. 15
4.2.3 Continuous Zoom power input ........................................................................................................................... 16
4.3 DIGITAL VIDEO OUTPUT INTERFACE .................................................................................................................................... 17
4.3.1 Camera Link interface (C models) ...................................................................................................................... 18
4.3.2 GigE interface (G models) .................................................................................................................................. 18
4.3.3 LVTTL interface (L models) ................................................................................................................................. 19
4.4 CAMERA MOUNT (FOR C AND G MODELS) ........................................................................................................................... 21
4.5 LENSES.......................................................................................................................................................................... 21
4.5.1 Manual Focus (13mm & 50mm) ........................................................................................................................ 22
4.5.2 Fixed Focus (25mm & 50mm) ............................................................................................................................ 23
4.5.3 Continuous Zoom ............................................................................................................................................... 25
4.6 ACCESSORIES ................................................................................................................................................................. 26
5 INSTALLING PC SOFTWARE ........................................................................................................................................ 27
5.1 THIRD PARTY TOOLS ........................................................................................................................................................ 27
5.1.1 Pleora PureGEV .................................................................................................................................................. 27
5.2 SOFRADIR-EC TOOLS ....................................................................................................................................................... 32
5.2.1 ATOM GUI Application ....................................................................................................................................... 32
5.3 INSTALL THE PLEORA ETHERNET DEVICE DRIVER (FOR GIGE CAMERA MODELS) ............................................................................ 33
6 INSTALLING CAMERA FILES ........................................................................................................................................ 34
6.1 NI CAMERA FILE (*.ICD) ................................................................................................................................................... 34
6.2 CUSTOMIZE THE NI CAMERA FILE TO OPERATE WITH A DIFFERENT FRAME GRABBER ..................................................................... 35
7 GIGE CONNECTION CONFIGURATIONS (FOR GIGE CAMERA MODELS) ........................................................................ 36
7.1 CONFIGURE WINDOWS FIREWALL (FOR GIGE CAMERA MODELS) .............................................................................................. 36
Page 3
Page 4
7.2 CONFIGURE THE GIGE FOR POINT-TO-POINT CONNECTION (FOR GIGE CAMERA MODELS) .............................................................. 36
7.2.1 Configure the PC NIC for static IP address (for GigE camera models) ................................................................ 36
7.2.2 Restore NIC setup for network connection (DHCP delivered IP address) ........................................................... 37
7.3 JUMBO FRAMES/PACKETS SETUP (FOR GIGE CAMERA MODELS) ................................................................................................ 38
7.3.1 PC NIC setup for jumbo frames/packets ............................................................................................................ 38
7.3.2 Verify setup of jumbo frames/packets ............................................................................................................... 39
7.4 ENABLING SIMULTANEOUS CAMERA CONTROL AND IMAGE ACQUISITION (FOR GIGE CAMERA MODELS) ............................................ 39
8 GETTING AN IMAGE ................................................................................................................................................... 41
8.1 CONNECTING YOUR CAMERA AND POWERING ON .................................................................................................................. 41
8.2 ACQUIRE AN IMAGE ......................................................................................................................................................... 42
8.2.1 Camera Link interface ........................................................................................................................................ 42
8.2.2 GigE Video interface ........................................................................................................................................... 43
8.2.3 LVTTL interface ................................................................................................................................................... 50
8.3 TROUBLESHOOTING YOUR IMAGE (FOR GIGE CAMERA MODELS) ............................................................................................. 51
9 CAMERA CONFIGURATION AND ADJUSTMENT .......................................................................................................... 53
9.1 USER CONTROL .............................................................................................................................................................. 53
9.2 ATOMGUI APPLICATION OVERVIEW .................................................................................................................................... 53
9.3 SERIAL COMMAND INTERFACE OVERVIEW ............................................................................................................................ 53
10 USING THE ATOM CONFIG ...................................................................................................................................... 54
10.1 CONNECTING & SAFE SHUTDOWN ..................................................................................................................................... 54
10.1.1 Connect to ATOM Config .................................................................................................................................... 54
10.1.2 Safe Shutdown ................................................................................................................................................... 54
10.2 INFO TAB ...................................................................................................................................................................... 55
10.3 VIDEO TAB .................................................................................................................................................................... 56
10.3.1 Detector Disable ................................................................................................................................................. 56
10.3.2 External Sync & Edge Detection ......................................................................................................................... 56
10.3.3 Select Image Zoom ............................................................................................................................................. 58
10.3.4 Zoom Window .................................................................................................................................................... 58
10.3.5 Lens Selection (only for customers purchasing multiple lenses) ........................................................................ 59
10.3.6 Setting Output Video Dynamic Range (8-bit or 14-bit) ...................................................................................... 59
10.3.7 Setting Frame Rate ............................................................................................................................................ 59
10.3.8 Setting Output Correction (Corrected or Uncorrected) ...................................................................................... 59
10.3.9 Video Source & Test Pattern Selection ............................................................................................................... 60
10.4 IMAGE TAB .................................................................................................................................................................... 61
10.4.1 Select Palette (White-Hot, Black-Hot) ................................................................................................................ 61
10.4.2 Setting Manual Gain and Level settings ............................................................................................................. 62
10.4.3 Setting AGC cutoffs ............................................................................................................................................ 62
10.4.4 AGC (Automatic Gain Control) Window ............................................................................................................. 62
10.5 NUC TAB ...................................................................................................................................................................... 63
10.5.1 Initiating a Touchup (against the shutter) ......................................................................................................... 63
10.5.2 Initiating a Touchup (through Lens) ................................................................................................................... 64
10.6 LENS TAB (ONLY FOR CZ LENS CAMERAS) ............................................................................................................................. 64
10.7 DEFAULT VALUES ............................................................................................................................................................ 65
11 PHYSICAL DIMENSIONS DRAWINGS ....................................................................................................................... 66
11.1 STANDARD LENS DIMENSIONS ........................................................................................................................................... 66
11.1.1 Universal Lens Mount Inteface........................................................................................................................... 66
11.1.2 13mm (f1.1) Manual Focus Lens Dimensions ..................................................................................................... 67
11.1.3 25mm (f1.2) Athermal Fixed Focus Lens Dimensions ......................................................................................... 68
11.1.4 50mm (f1.2) Athermal Fixed Focus Lens Dimensions ......................................................................................... 69
11.1.5 50mm (f1.0) Manual Focus Lens Dimensions ..................................................................................................... 70
Page 4
Page 5
11.2 ATOM 1024-20 C MODEL PHYSICAL DIMENSIONS.............................................................................................................. 71
11.3 ATOM 1024 G MODEL INTERFACE PHYSICAL DIMENSIONS ................................................................................................... 72
11.4 ATOM 1024 L MODEL INTERFACE PHYSICAL DIMENSIONS .................................................................................................... 73
11.5 ATOM 1024 G (CZ 25-225MM) MODEL INTERFACE PHYSICAL DIMENSIONS ........................................................................... 74
11.6 ATOM 1024 G (CZ 25-150MM) MODEL INTERFACE PHYSICAL DIMENSIONS ........................................................................... 75
11.7 ATOM 1024 G (CZ 15-100MM) MODEL INTERFACE PHYSICAL DIMENSIONS ........................................................................... 76
12 SPECIFICATIONS ..................................................................................................................................................... 77
13 MAINTENANCE ....................................................................................................................................................... 78
13.1 CLEANING ..................................................................................................................................................................... 78
13.1.1 Non-Optical Surfaces.......................................................................................................................................... 78
13.1.2 Optical Surfaces ................................................................................................................................................. 78
13.2 REPLACING COMPONENTS ................................................................................................................................................ 78
14 WARRANTY ............................................................................................................................................................ 78
15 REPAIRS ................................................................................................................................................................. 79
15.1 RETURNING PRODUCTS FOR WARRANTY REPAIR ................................................................................................................... 79
15.2 RETURNING PRODUCTS FOR “OUT OF WARRANTY REPAIR ..................................................................................................... 80
16 CONTACT INFORMATION ....................................................................................................................................... 80
Page 5
Page 6
1 About
1.1 Trademarks
LabVIEW, National Instruments, and NI are registered trademarks of National Instruments Corporation.  Camera Link is a registered trademark of Automated Imaging Association  GEVPlayer is a registered trademark of Pleora Technologies Inc.  ATOMTM is a trademark of Sofradir-EC Inc.
1.2 Licensing
Software
“Software” is defined as machine-readable code or firmware, which is owned by or licensed to Sofradir-EC Incorporated, resides in Product memories, tapes, disks, CDs, or other media and provides operating instructions.
With respect to any Software that is furnished to BUYER and/or BUYER’s customers (“Recipient”) hereunder, the
Recipient is granted a non-exclusive, license to use the Software in conjunction with the Product(s) purchased, for the life of said Product. Notwithstanding the foregoing, the Recipient is not granted any title or ownership rights to the Software whatsoever. The Recipient is not authorized to reproduce, copy, modify, repair, decompile, reverse engineer, disassemble, reverse translate, or in any manner decode the Software. BUYER agrees to include and enforce terms no less stringent to its customers.
Use of the software on the camera, and included in any additional distribution media, is subject to the terms of the end user license agreement. You should not use the camera or any related software until you have read the end user license agreement. The complete end user license agreement is included on the "ATOM Software" CD included with your camera. By using the software, you signify that you have read the end user license agreement and accept its terms.
Remedies, Damages and Limitations
IN NO EVENT SHALL SOFRADIR-EC INCORPORATED BE LIABLE FOR INDIRECT, INCIDENTAL, SPECIAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, LOSS OF USE OR DATA OR INTERRUPTION OF BUSINESS, WHETHER SUCH ALLEGED DAMAGES ARE LABELED IN TORT, CONTRACT OR INDEMNITY, EVEN IF SOFRADIR-EC INCORPORATED HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, FURTHERMORE, DIRECT DAMAGES ARE STRICTLY LIMITED TO THE VALUE OF THE PRODUCT.
Actions, however asserted, shall be commenced within two years from the date the cause of action accrues; provided, however, an action for nonpayment may be commenced at any time within four years from the date the cause of action accrues.
1.3 Warnings
The ATOM 1024 camera and related firmware and software components are not designed or intended for use or resale in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communications systems, air traffic control, or other devices or systems in which a
Page 6
Page 7
malfunction of the camera hardware or software would result in foreseeable risk of injury or death to the operator of the device or systems, or to others.
Operating
Do not use a dedicated PoCL (Power over Camera Link) Frame Grabber with the camera.
Handling
Avoid touching the detector window. Install the dust cap when the lens is removed.
Avoid touching the lens. Install the lens cap when the camera is not in use.
Window cleaning
Cleaning of the window should only be considered in case of absolute necessity. Only use isopropyl alcohol and special lens paper for optics. Follow classical rules for optics cleaning (only translation motion without return, from the center to the edge, never use the paper twice, etc.).
Detector life
Avoid viewing very intense energy sources, such as the sun, lasers, electrical arcs, whether powered or not since this may cause damage to the detector or to its factory calibration.
Accessories
Use only the approved accessories and options with this product. Incompatible accessories may damage the camera, compromise equipment safety measures and/or provide inaccurate readings.
Restriction–of–Use Environments
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
The following disclaimers apply as non-standard, non-warrantied applications:
1. Unit is not intended for permanent, fixed-mount outdoor applications.
2. Unit is not designed to withstand immersion or exposure to rain.
3. Unit is not intended for exposure to salt water atmosphere.
4. Unit is not intended for dynamic-mount applications, such as on vehicles or heavy machinery, in which the transmitted vibration is continuously sustained.
5. Unit should be placed in a carrying case when not in use.
ITAR Restriction
Equipment described herein may require US Government authorization for export purposes.
Page 7
Page 8
ATOM Model
Lens
HFOV (nominal)
1024-73L (LVTTL)
13mm, f1.1 manual focus
73º
1024-73C (Camera Link)
1024-73G (GigE)
1024-20L (LVTTL)
50mm, f1.0 manual focus
OR
50mm, f1.2 fixed focus
20º
1024-20C (Camera Link)
1024-20G (GigE)
1024-40L (LVTTL)
25mm, f1.2 fixed focus
40º
1024-40C (Camera Link)
1024-40G (GigE)
1024-67/10G (GigE)
15-100mm, f1.4 continuous zoom
motorized focus
9.15-56º
1024-40/6.6G (GigE)
25-150mm, f1.4 continuous zoom
motorized focus
6.6-40º
1024-40/4.4G (GigE)
25-225mm, f1.4 continuous zoom
motorized focus
4.4-40º
2 Model Overview
Page 8
Page 9
3 Getting started
3.1 Unpacking
Carefully inspect the shipping container for damage. Remove the contents from the box and check for visible damage. Check if the following items are included:
1. Camera
2. Power Supply
3. CD/DVD Release Software Disk (which includes a copy of the User Manual)
4. Quick Start Guide
5. Additional Accessories ordered (Lens, cables)
3.2 What you need to get started
To setup and use the ATOM 1024 camera, the following items are needed:
ATOM™ 1024 Camera For L models, customer designed hardware is required to power the camera and access the video
stream.
Power Supply  PC running XP/Vista/Win7 with latest Service Packs installed and at least one of the following:
o 1000Base-T Ethernet interface (for cameras with GigE Video interface) o Camera Link Frame Grabber (for cameras with Camera Link interface)
Note: Do not use a “dedicated PoCL Frame Grabber to avoid damaging the Frame Grabber
and/or the PC. Use either a conventional Camera Link Frame Grabber or a “switchable” PoCL
Frame Grabber with SafePower which can detect if the camera is/is not PoCL compliant and handle accordingly.
Standard Cables
o Camera Link cable (for cameras with Camera Link) - Mini-Camera Link to Standard Camera Link
(SDR to MDR) cable
o Ethernet cable - (for cameras with GigE Video Port) - CAT-5e or better Ethernet cable
CD/DVD Release Disk (containing software and documentation)
Page 9
Page 10
3.2.1 ATOM 1024 SW Support Disk contents
1. ATOM 1024 Release Notes.pdf
2. ATOM 1024 User Manual.pdf (This manual)
3. Standard ATOM 1024 EULA 030612.pdf (End User License Agreement)
Folders:
ATOM SW – contains (GUI Application files, NI frame grabber configuration file (.icd) (Camera Link based cameras only), Readme.txt
Pleora – contains installer and documentation for GigE Vision software (for GigE based cameras only)
3.2.2 Additional Documents
The Quick Start Guide is a brief guide to get your Atom 1024 setup, installed and running. This document is included on the software CD as well as in the box with the camera.
At additional cost, the following documents are available:
Atom 1024 Advanced Interface Guide  Atom 1024 Software Development Kit
3.2.3 Frame Grabber support notes
Some Camera Link frame grabbers require a minimum pixel clock of 20MHz. The ATOM 1024 will need to be configured for XGA (1024x768) Video Output Resolution to produce the required pixel clock to use these frame grabbers. If VGA (640x480) Video Output Resolution is desired, use either the NI PCI-1426 or NI PCIe-1427 Camera Link frame grabbers which have been tested and work with the ATOM 1024 cameras.
3.3 Features
High Performance imaging High resolution XGA format (1024x768) with superb image detail and
excellent thermal sensitivity for increased range and detection performance
Short Thermal Time Constant for sharp images of objects in motion  Low power consumption for long battery life  Integrates easily into multiple platforms  External Sync feature  Motorized Continuous Zoom Lens support
Page 10
Page 11
Power
Camera Link
Camera Mount
4 Hardware Overview
Incorporating ULIS’s advanced all silicon microbolometer technology, the ATOM 1024 is a true High Definition
(XGA format) thermal imaging module specially designed for delivering high resolution analysis and optimal thermal sensitivity to a wide variety of applications.
The ATOM 1024’s small package and low power consumption coupled with its superior thermal image quality
makes for ideal integration within military and COTS thermal imaging systems, and an excellent choice for handheld, ground/airborne EOIR platforms, and advanced fusion based night visions systems.
4.1 Camera Panel Description
4.1.1 Camera Link
Above is an example of an ATOM 1024 with a Camera Link video interface (with an f 1.0 50mm manual focus lens)
See Section 4.2.1 for the power supply pin layout.  See Section 4.3.1 for more on the Camera Link video interface.  Camera Mount
Page 11
Page 12
Camera Mount
Power
GigE
4.1.2 GigE
Above is an example of an ATOM 1024 with a GigE video interface (with an f 1.2 50mm fixed focus lens)
See Section 4.2.1 for the power supply pin layout.  See Section 4.3.2 for more on the GigE video interface.
Page 12
Page 13
LVTTL Connector
4.1.3 LVTTL
Above is an example of an ATOM 1024 with an LVTTL video interface (with an f 1.0 50mm manual focus lens)
See Section 4.3.3 for the power supply pin layout.  See Section 4.3.3 for more on the LVTTL video interface.  The LVTTL model does not have a Camera Mount
Page 13
Page 14
Power
GigE
4.1.4 Continuous Zoom
The Continuous Zoom models come with a GigE video interface.
See Section 4.2.3 for the power supply pin layout.  See Section 4.3.2 for more on the GigE video interface.
Page 14
Page 15
NAME
Pin
PWR (6V)
1
Do Not Use
2
GND
3
Do Not Use
4
Do Not Use
5
4.2 Power input jack
4.2.1 Camera Link & GigE power input
Power input connection for 6V DC supply. The connector is a circular type receptacle (Hirose p/n HR10A-7R­5S(73)). See Figure 1 for connector pin location and Table 1: Power input connector pin-out for connector pin­out.
Figure 1: Power input connector pin ID
Table 1: Power input connector pin-out
4.2.2 LVTTL power input
See Section 4.3.3 for information on the LVTTL power input.
Page 15
Page 16
ATOM 1024 CZ 25-225mm
The parts included to power the CZ camera (with part numbers from TE Connectivity):
Power Supply 12V 1.5A minimum2-pin housing (770602-2)Crimps (770601-2) & Crimp Tool
(58517-1)
Negative Positive
422 Level Converter Board, as displayed above
ATOM 1024 CZ 25-150mm
4.2.3 Continuous Zoom power input
Page 16
Page 17
Physical
Display
FOV
Output
Frame
Frame
Rate
User
Zoom
#
Detector
Columns
# Display Columns
Actual
Electronic
Zoom
XGA-
VGA Dual
Mode
Wide
XGA
30
1
1024
1024
1
2
512
1024
2
3
341
1024
3.0029326
4
256
1024
4
Medium
VGA
60
1
640
640 1 2
320
640 2 3
213
640
3.0046948
4
160
640
4
Narrow
VGA
60
1
320
640 2 2
160
640 4 3
107
640
5.9813084
4
80
640
8
4.3 Digital Video Output Interface
Depending on the model, the Digital Video output interface will be LVTTL, Camera Link, or GigE. The digital video interface provides 14 bits of parallel pixel data, with clock signals identifying pixels (pixel clock),
lines (horizontal sync), and frames (vertical sync). It will be selectable between uncorrected raw, full amplitude resolution non-uniformity corrected, and 8-bit gain and level compensated image data. When operating in 8-bit mode, the output bits will occupy the most significant bit positions of the parallel output channel, with the unused bit positions set to zero values.
Video imaging can be managed by making three selections:
Input field of view This selection specifies the effective image field of view by adjusting the FPA
pixel region used to generate the output image. Output resolution Specify the resolution of the output signal Digital zoom level Apply an image zoom transformation between the input and output images
The following table identifies the video modes, and provides explicit input and output resolution information for each. Not all modes are supported on all models; grayed out entries and accompanying explanations are not supported for the system shipped with this document.
Table 2: Video Modes
When operating in the 1024x768 resolution, the FPA is configured to output the maximum resolution, with all pixels displayed. When a zoom command is applied in this mode, a smaller rectangular area of pixels centered in the original image will be digitally expanded to fill the 1024x768 output frame.
Page 17
Page 18
Video mode
Bits/pixel
NUC Applied
Gain/Level Applied
Zoom Applied
Polarity Selection Applied
Uncorrected raw
14
No
No
No
No
Corrected raw
14
Yes
No
No
No
Palletized
8
Yes
Yes
Yes
Yes
LED
Status
Off
No connection
Green
Connected
Blinking Green
Data is being transmitted or received
In addition to selecting the output signal resolution, the System Controller can also specify the pixel encoding and processing using the Video Tap serial command (Registers 0x11, 0x91). The output video modes supported by the ATOM 1024 Thermal Imaging Module are listed in the following table:
Table 3: Video Output Processing Modes
4.3.1 Camera Link interface (C models)
The Camera Link interface is compliant with the Base Camera Link standard which supports 5 LVDS pairs for the serialized video data and sync, 2 LVDS pairs for asynchronous serial communication, and 4 LVDS pairs for discrete control signals. The discrete control signals are not used with the ATOM 1024 Camera and are terminated. The connector is a Mini-Camera Link 26-pin 3M SDR receptacle. Power over Camera Link, PoCL, is not supported.
4.3.2 GigE interface (G models)
The GigE interface provides network connectivity to transmit high-speed video and control data at gigabit speeds. The connector is a RJ45 type connector with 2 LED’s to display network activity and connection speed.
4.3.2.1 Network Activity LED
Table 4: GigE Network Activity LED
4.3.2.2 Network connection speed LED
Page 18
Page 19
LED
Status
Off
No connection, 10Mbps connection,
100Mbps connection
Green
1Gbps connection
NAME
I/O
J1
(Pin)
J1
(Pin)
I/O
NAME
GND
I 1 70 I SHUTTER_PWR
GND
I 2 69 I SHUTTER_PWR
3.3V_PWR_IN
I 3 68
3.3V_PWR_IN
I 4 67 I 3.3V_PWR_IN
3.3V_PWR_IN
I 5 66 I 3.3V_PWR_IN
3.3V_PWR_IN
I 6 65 I 3.3V_PWR_IN
GND
I 7 64 I GND
GND
I 8 63 I GND
9 62
10
61
RS232_TX
I
11
60
RS232_RX
O
12
59
CC1(External
Sync)
I
13
58
CC2
I
14
57
15
56
16
55
17
54
Table 5: GigE Network connection speed LED
4.3.3 LVTTL interface (L models)
The LVTTL interface provides a connection to customer designed video output board. The video signals are 3.3V LVTTL and are not intended to be driven over a cable. The 70-pin camera connector interface supports, 14 bits of data, framing, clock and 2 asynchronous serial signals along with 2 control signals and power. The connector is a 70-pin 0.5mm pitch board to board 2mm height header (Hirose p/n DF17(2.0)-70DP-0.5V(57)). See Table 6 for connector pin-out.
Table 6: LVTTL connector pin-out
Page 19
Page 20
NAME
I/O
J1
(Pin)
J1
(Pin)
I/O
NAME
18
53
19
52
PCLOCK
O
20
51 O FRAME_SYNC
LINE_SYNC
O
21
50
22
49 O D12
23
48 O D13
GND
I
24
47 I GND
25
46 O D11
26
45 O D10
27
44 O D9
28
43 O D8
29
42 O D7
GND
I
30
41 I GND
31
40 O D6
32
39 O D5
33
38 O D4
D0
O
34
37 O D3
D1
O
35
36 O D2
3.3V_PWR_IN: 3.3V-3.45V Conditioned Power. SHUTTER_PWR: 3.3V-3.45V Conditioned Power. GND: Ground D [0:13]: 14 bits of data. PCLOCK: Clock used to synchronize the data. FRAME_SYNC: Frame Sync used to signal the start of a frame. LINE_SYNC: Line Sync used to signal the start of a line. RS232_TX: Serial Data received by the ATOM RS232_RX: Serial Data transmitted by the ATOM CC1: 3.3V LVTTL signal External Sync CC2: 3.3V LVTTL signal (for future use)
The 14-bit parallel data bus contains full-dynamic range RAW/NUC digital output with bad pixel correction. The ATOM 1024 system changes Output Video data on the falling edge of PCLOCK. The system receiving data from the ATOM 1024 system should latch it on the rising edge of this clock.
Page 20
Page 21
TXDFRAME
LINE SYNC
DATA 13:0
[1
Line1
Line2
LineN
Figure 2: Digital Interface Frame Timing
Number of active LINES in each active Frame is 768 for XGA and 480 for VGA modes.
4.4 Camera Mount (for C and G models)
The ATOM 1024 C and G models have a camera mount so the camera may be mounted on a tripod. The L models do not have a camera mount.
4.5 Lenses
ATOM 1024 lenses come in three different types:
Manual Focus  Fixed Focus  Continuous Zoom
Page 21
Page 22
4.5.1 Manual Focus (13mm & 50mm)
4.5.1.1 13mm f/1.1 Manual Focus 73° FOV
4.5.1.2 50mm f/1.0 Manual Focus 20° FOV
Page 22
Page 23
Inner Lens
Lock Ring
Grooves
4.5.2 Fixed Focus (25mm & 50mm)
4.5.2.1 Fixed focus (25mm f/1.2 40° FOV)
Adjusting the 25mm Fixed Focus Lens
The fixed focus lens allows the option to unlock and change the focus; then re-lock the lens in place with the lock ring.
1. While facing the camera, use
the grooves on the lock ring to turn it counterclockwise in order to unlock the inner lens.
2. Rotate the inner lens to the
appropriate new location.
3. While holding the inner lens in
place, use the grooves to turn the lock ring clockwise until it locks tight.
Important: Be careful to not overturn the lens; it will come off. Less than one full turn is required for the full range of focus. The minimum focus is 2 meters; a closer focus can be achieved with caution. For hyperfocal distance, focus the lens at 45 meters for focus from 25 meters to infinity. Focus the lens at 35 meters for focus from 17.5 meters to infinity.
Page 23
Page 24
Focus Grip
Lens Baffle
Locking thread
4.5.2.2 Fixed Focus (50mm f/1.2 20° FOV)
Adjusting the 50mm Fixed Focus Lens:
1. Rotate the Focus Grip to adjust your focus.
2. When the desired focus is reached, insert the supplied lockdown screw (replacement screw: Nylon Tip
18-8 SS Socket Set Screw 4-40 Thread, 1/8" Length McMaster part number: 90291A103) into the hole
circled below.
3. Hand-tighten the screw.
Note: Do not grip the Outer Lens to change focus as it will not adjust the focus; it can turn independently of the focus grip.
Special to the Athermal Lens:
You will notice that the Lens Baffle can expand and contract up to a few millimeters. When positioning your camera for use, be sure to leave room for the Lens Baffle to move freely in and out. Restricting the fluctuation of the Lens Baffle will negatively affect the Athermal functions of the lens.
Page 24
Page 25
4.5.3 Continuous Zoom
4.5.3.1 25-150mm f/1.4 Continuous Zoom motorized focus 6.6-40° FOV
4.5.3.2 25-225mm f/1.5 Continuous zoom motorized focus 4.4-40° FOV
Page 25
Page 26
4.5.3.3 15-100mm f/1.4 Continuous zoom motorized focus 9.15-56º FOV
4.6 Accessories
Camera Link Cable (Mini – Standard)
o 2m (915154) o 5m (915155) o 10m (915156)
Power Supply with serial cable (915288) Camera Link Frame Grabber Boards:
o 16MB PCI-1426/16 (915219) o 32MB PCI-1426/32 (915220) o PCI-1428 (915221) o PXI-1428 (915222) o PCIe-1427 (915223) o PCLe-1429 (915243)
Camera Link LVTTL Conversion Kit (915325)
Page 26
Page 27
Run the Setup application in the Pleora folder.
Click on the “eBUS-PureGEV Package” button to install the software.
5 Installing PC Software
5.1 Third Party Tools
When installing all of the third party software packages, take care to review the End User License Agreements associated with each. Sofradir-EC provides these packages on our installation media as a convenience, and takes no responsibility for performance and reliability, and provides no direct support for these products.
5.1.1 Pleora PureGEV
For information regarding Pleora release compatibility, please reference the release notes.
The Pleora PureGEV package includes an application to display video captured from a standard GigE Video camera. This application is named “GEVPlayer”, and may be useful in Gigabit Ethernet environments.
Page 27
Page 28
Click on the “Next” button to continue to
install the software.
Read the end-user software license agreement and click the bullet next to the statement of accept once the license agreement has been reviewed and agreed to.
Click on the “Next” button to continue.
Page 28
Page 29
Click on the “Next” button to continue. If the
default folder location is not acceptable click
on the “Change” button to edit the folder location then click on the “Next” button to
continue.
Click on the “Install” button to continue.
Page 29
Page 30
Click on the “Finish” button when completed.
Page 30
Page 31
Following a successful installation, these new items should appear on your Start menu under the Pleora Technologies Inc heading. Select the item for GEVPlayer to start the video acquisition application.
Page 31
Page 32
5.2 Sofradir-EC Tools
Review the Readme.txt file for ATOM GUI application installation instructions.
5.2.1 ATOM GUI Application
The ATOM GUI application is the program that allows you to send communications to your ATOM 1024 camera.
Initiating the ATOM GUI setup wizard will present you with a preliminary welcome screen. Click 'Next' to proceed to the installation folder.
The recommended settings will present the ATOM GUI installation path by default. A manual installation path can be selected by clicking browse, and selecting a folder through the explorer. Also, at this point you may select your preference as to how ATOM GUI may be accessed between accounts.
Click ‘Next’ to proceed to the next installation screen, and then next again to commence installation.
Your installation will proceed with a status bar at this point. Selecting cancel at any time prior to completion will abort the installation procedure. Once this has completed, click 'Close'.
Page 32
Page 33
5.3 Install the Pleora Ethernet device driver (for GigE camera models)
1. Run the Driver Installation Tool from All Programs > Pleora Technologies Inc. > eBUS SDK > Tools
2. Verify the current driver installed.
3. Select the driver from the Action pull down menu then click Install.
Page 33
Page 34
4. Click Install again to install the device driver.
5. Verify the Current Driver installed is an eBUS driver.
6. Click Close when done.
6 Installing Camera Files
Cameras using the Camera Link interface require camera files for the NI software to communicate between the NI frame grabber and the camera.
6.1 NI camera file (*.icd)
1. Locate the NI camera file (*.icd) on the CD/DVD Release disk or electronic mail.
2. Copy the NI camera file to: Vision Acquisition Software prior to 8.2.3 Place the *.icd file in <National Instruments>\NI-IMAQ\Data
Vision Acquisition Software 8.2.3 and later For Windows XP, place the *.icd in C:\Documents and Settings\All Users\Shared Documents\National
Instruments\NI-IMAQ\Data For Windows 7, place the *.icd in C:\Users\Public\Public Documents\National Instruments\NI-
IMAQ\Data
Page 34
Page 35
6.2 Customize the NI Camera File to operate with a different frame grabber
The distribution media, CD/DVD or electronic mail, contains a NI Camera File that is designed to work with the most popular NI Camera Link frame grabbers: the PCI-1426, and the PCIe-1427. If you have a different NI frame grabber, you can modify one of the provided camera files to work with your frame grabber using the NI Camera File Generator software. An installer for this package is provided on the distribution media in the folder “\National Instruments\Camera File Generator”.
To use the NI Camera File Generator to add support for additional frame grabbers, follow these steps on the PC that has the target frame grabber installed:
1. Verify that the SEC provided camera files (.icd) have been copied to the appropriate folder on your PC, as
described in the section above.
2. Run the NI Camera File Generator program.
3. On the initial screen, click on the button labeled “Open Existing Camera File.
4. Navigate to the NI camera file folder, and select one of the provided SEC camera files (e.g. Sofradir-EC
ATOM 1024.icd).
5. The program should notify you that the opened file does not support the installed frame grabber, and offer
to update it to include support. Click on the “Yes” button:
6. Click on the “File” item in the program’s menu bar, and save the camera file with a new name.
7. Close the NI Camera File Generator program.
8. You should now be able to select and use this new camera file from within the NI Measurement &
Automation application to display video. Note that if it is more convenient, the NI Camera File Generator program can also be used to display streaming video from the camera.
Page 35
Page 36
7 GigE Connection Configurations (for GigE camera models)
7.1 Configure Windows Firewall (for GigE camera models)
Configure Windows Firewall to allow GEV Player through.
1. From the Start menu, select Start > Control Panel
2. From the Control Panel, select the category System & Security, then Windows Firewall
3. From Windows Firewall, select Allow a program through Windows Firewall.
4. Put a check in the box for GEVPlayer. Note: If GEVPlayer is not listed, select the Add program button
and add it to the list.
5. If other firewall software is installed (e.g. Norton Internet Security), use the equivalent procedure to permit
access.
7.2 Configure the GigE for point-to-point connection (for GigE camera models)
7.2.1 Configure the PC NIC for static IP address (for GigE camera models)
The PC NIC will need to get an IP address, either from a DHCP server if in a typical network setup or manually programmed in a point-to-point connection.
1. From the Start menu, select Start > Control Panel
2. From the Control Panel, select Network and Sharing
Center
3. Right click on local network connection and select
Properties.
4. Select Internet Protocol Version 4 (TCP/IPv4) and
click the Properties button.
Page 36
Page 37
5. Select the “Use following IP address” bullet and enter 192.168.1.1 for the IP address and 255.255.255.0
for the Subnet mask. Note: The Subnet mask may automatically be filled in with 255.255.255.0 after the IP address is entered.
6. Click Ok when done.
7.2.2 Restore NIC setup for network connection (DHCP delivered IP address)
1. Select the “Obtain an IP address automatically” and
“Obtain DNS server address automatically” bullets.
2. Click Ok when done.
Page 37
Page 38
7.3 Jumbo frames/packets setup (for GigE camera models)
Before using Jumbo frames, make sure the PC NIC and Ethernet switches support Jumbo frames, otherwise the packets will be discarded.
7.3.1 PC NIC setup for jumbo frames/packets
For Windows 7,
1. Select Start
2. Right-click on Computer
3. Select Manage
4. Click on Device Manager on the left side
5. Click on Network Adapters in the center
6. Right-click on the Network Adapter being used
7. Select Properties
8. Click the Advanced Tab
9. Select Jumbo Frames from the list of properties and select the MTU size from the value pull-down
10. Click Ok when done and close the Computer Management window.
Page 38
Page 39
7.3.2 Verify setup of jumbo frames/packets
1. Open a Command Prompt window, Click on Start > Run, then type Cmd in the Run box and click Ok.
2. In the Command Prompt window, type the following and hit Enter
ping [–f] [–l size] [target name or IP address] ping –f –l 9000 192.168.0.133
3. Verify ping works.
7.4 Enabling simultaneous camera control and image acquisition (for GigE camera models)
For the user to control the camera while acquiring images, the Pleora GEV Player must be set as a data receiver and multicast mode must be used for streaming. Without multicast enabled, video can be displayed, but the camera controls are unavailable.
Important Note: Multicast mode uses IGMP and requires an IGMP compliant Ethernet switch if used in a network. If connecting point-to-point, an IGMP compliant Ethernet switch is not required.
1. Make sure GEV Player is setup correctly, (i.e. network, point-to-point, image size), and can acquire video.
2. Click the Stop button and the Disconnect button.
3. Launch AtomGui from your computer by clicking the AtomGui.exe application file.
4. Select your method of connection from the Interface pull-down menu.
5. Click the Connect button.
6. Select the Multicast check box as seen below.
Page 39
Page 40
7. From the GEV Player main screen, Select Tools then Setup.
8. From the Setup window, select Data receiver and Multicast.
9. Make sure that the Multicast address from the GEV Player matches the Atom Gui Multicast Address (as
shown above)
Page 40
Page 41
10. Click Ok
11. In GEV Player, Click the Select / Connect button.
12. Select your Gig-E interface and verify that the Access Status says “Control” highlighted in yellow.
13. Click OK
14. The GEV Player should now display video and the GUI can be used to control the camera.
Note: The Play and Stop button are not active as well as the GEV Device control button so if a change in image size is needed the GEV Player will need to be set back to Controller and Data receiver.
8 Getting an Image
8.1 Connecting your camera and powering on
1. Connect the digital video interface to the acquisition hardware with the appropriate cable. a. For LVTTL, connect the custom designed hardware, connected to the LVTTL 70-pin connector, to
the appropriate designed for ima acquisition hardware with an appropriate cable. Note: The custom designed hardware should have a video interface from which to connect to an
image acquisition device.
b. For Camera Link, connect the Mini-Camera Link connector to the Frame Grabber with a Camera
Link cable.
c. For GigE, connect the GigE Video RJ-45 connector to a network switch or directly to a PC’s
gigabit Ethernet port with a Cat-5e or better Ethernet cable. Note: Review the following and perform the necessary steps.
i. Update to the Pleora Ethernet Driver (See Section 5.3)
ii. Configure Windows Firewall (See Section 7.1) iii. Decide on either point-to-point or network connection iv. Configure NIC IP address (if point-to-point; See Section 7.2.1)
v. Configure Camera’s GigE IP address (if point-to-point) vi. Configure NIC for Jumbo packets (See Section 7.3)
vii. Configure switches for Jumbo packets
Additional Note: Try to acquire images without user control first. Once this is accomplished, configure the PC and cameras GigE Video interface to add simultaneous user control if needed.
2. Connect the Power Supply to the camera and plug into an AC outlet.
Note: After power is first applied, the shutter can be heard closing and opening.
Page 41
Page 42
8.2 Acquire an image
8.2.1 Camera Link interface
1. Launch Measurement & Automation Explorer (MAX) from the desktop shortcut or the start menu. (Make sure your Atom CD installation CD is in your computer before your first use.)
2. In the Configuration panel, select Devices and Interfaces > NI-IMAQ Devices.
3. Under the NI-IMAQ Devices the image acquisition hardware will show, select the image acquisition hardware to use, (i.e. img0 : NI PCIe-1427).
4. Select the channel of the image acquisition device.
5. For your first use, right-click on the
Channel item and select Open Camera. This will allow you to
browse to your Installation CD’s
camera file.
6. Navigate to your CD-drive containing the Atom1024 installation disk.
Navigate to AtomSW >
AtomGui for CameraLink > SofradirEC14BitCameraLink.ic d (as seen to the right).
7. For following uses, right-click
Channel, click the Camera drop-down and choose the Sofradir-EC selection (as seen to the right) and choose the appropriate camera.
8. From the Acquisition Parameters tab near the bottom of the window, setup the Width and Height.
9. Click Snap to acquire a single image or click Grab to continuously acquire images.
10. Right-Click the image and select Viewer Tools > Zoom to Fit for the full image.
Page 42
Page 43
8.2.2 GigE Video interface
Review the following and perform the necessary steps.
a. Update to the Pleora Ethernet Driver to improve performance (See Section 5.3) b. Configure Windows Firewall to allow GEV Player through (See Section 7.1) c. Configure for network or point-to-point connection d. If point-to-point connection, configure static IP addresses for PC NIC and Camera GigE port (See
Section 7.2.1) e. Configure for Jumbo packets (not required) (See Section 7.3) f. Use workaround steps to simultaneous use the GUI to control and GEV Player to acquire images
Acquire video by performing the steps for a network connection or point-to-point connection.
Note: There is a workaround needed to be performed in order to simultaneously use the GUI to control the camera and use GEV Player to acquire images. See Section 7.4 on the steps needed to be performed.
8.2.2.1 GigE Video interface network connection
1. Launch GEVPlayer from the desktop shortcut or the start menu.
2. Click the Select / Connect button.
3. Select the Gig-E interface.
4. If your device is not listed, select the “Show unreachable GigE Vision Devices” checkbox. Click on “Set IP Address” and enter an appropriate address and net mask.
Note: If more than one camera is located, verify the correct interface with the MAC address.
Page 43
Page 44
5. Click the Play button
6. Observe Error count is 0 and the Stream number of images is incrementing.
8.2.2.2 GigE Video interface point-to-point connection
1. Configure the PC’s NIC for a static IP address (Section 7.2.1)
2. Launch GEVPlayer from the desktop shortcut or the start menu.
3. Click the Select / Connect button.
4. Check the Show unreachable GigE Vision Devices.
Page 44
Page 45
5. Select the Gig-E interface.
Page 45
Page 46
6. Select the “Set IP Address…” button.
Page 46
Page 47
7. Enter a two as the last digit of the IP address and click OK.
Page 47
Page 48
8. Verify the IP Configuration is Valid now.
Page 48
Page 49
9. Select the GigE interface and click OK.
10. The following warning may be displayed. Click Ok. Note: It is recommended to go back and update the Ethernet device driver for improved performance (See Section 5.3).
Page 49
Page 50
11. Select the GEV Device control button
12. Setup Width, Height, PixelFormat (Mono14) and TestImageSelector (Off).
13. Click the Play button and observe Error count is 0 and the Stream number of images is incrementing.
8.2.3 LVTTL interface
Note: The LVTTL interface is intended to connect to custom designed hardware. The custom designed
hardware will provide an interface from which to acquire an image.
Note: The Camera Link LVTTL Conversion Kit (915325) can be used to image and benchmark the core camera
functions and allow for debugging customer interface hardware.
Page 50
Page 51
If the Gigabit Ethernet interface hardware is configured to generate a test pattern instead of live video from the camera, the displayed images will be a saw-tooth pattern that moves from right to left at a speed that depends on the configured image size.
Follow the instructions in Section 8.2.2 that describes configuring GEV Player in Unicast mode to resolve this problem.
Note that the camera may default to test pattern mode each time it is powered on.
If the image pixel configuration is not set to 14 bits per pixel, the resulting image will appear excessively noisy, and may show repeating patterns in areas of low contrast.
Follow the instructions in Section 8.2.2 that describes configuring GEV Player in Unicast mode to resolve this problem.
8.3 Troubleshooting your image (For GigE Camera Models)
This section contains images that illustrate the effects of common configuration problems.
Page 51
Page 52
If the image dimensions are not set correctly, you will see a correctly acquired and displayed image, but the image field of view will not be correct. You will likely see a smaller image area than expected.
If you see vertical banding of any size in the image, this may simply be the result of a mismatch between the display window size and the screen resolution.
If you see this effect, try resizing the window until the displayed image is clean.
In this example, a dramatic improvement to the image quality was achieved by just changing the window size.
Keep in mind that the display program is attempting to scale a 1024x768 pixel image into a variable sized window. Optimal image quality will be obtained if the display area is an integral multiple of the fundamental image size (e.g. 2x, 1x, 1/2x, 1/4x).
Page 52
Page 53
9 Camera configuration and adjustment
9.1 User Control
Camera control is implemented over the serial transmit and receive lines for the Camera Link video interface and packetized for the GigE video interface. The AtomGui sample application provides a user friendly interface for camera control, although individual commands can be arranged to read and write registers directly for testing and debugging purposes.
Note for Camera Link models: The AtomGui supports NI Frame Grabbers. If the user intends on using another manufacturer Frame Grabber and still needs camera control, the serial interface can be changed from the Camera Link serial lines to a separate serial interface requiring a Power Supply with Serial Cable accessory (915288) and a camera setting change. The Power Supply with Serial Cable serial port can be connected to a PC COM port and the AtomGui setup to use the PC COM port. Currently the serial port camera setting is not available to the user and will need to be sent back unless the camera was purchased with this configuration.
Note for GigE models: The AtomGui cannot control the camera at the same time video is acquired. If the user needs to control the camera while acquiring images, the GEV Player software can be setup as a Data Receiver with Multicast streaming enabled. A description of the workaround is in Section 7.4.
9.2 AtomGui application overview
The AtomGui sample application provides a user interface to control the camera. The GUI handles proper command formation and communication with point and click simplicity. Section 10 outlines each of the GUI screens while also displaying the read command byte mapping for each control.
9.3 Serial Command Interface overview
The Serial Command Interface utilizes the serial TXD and RXD signals within the video interface to exchange status and configuration information. Allowing lower level functionality, the user can formulate commands and interface with ATOM 1024 control registers directly. The user is then able to control FPGA operations for help in design debugging and production testing. And, to read and write FPGA registers (e.g. current operating/configuration settings) and SDRAM memory (e.g. test patterns, diagnostic frame captures), useful for debugging and manufacturing purposes.
Serial command exchanges are initiated by the external controller, with responses and acknowledgements generated by the ATOM 1024. The ATOM 1024 will not generate any asynchronous serial messages that are not a direct response to an external command or query.
The serial interface settings are 57600 baud, 8 bit data, 1 stop bit, no parity, and no flow control. The ATOM 1024 receives data on the TXD signal and transmits data on the RXD signal. The TXD and RXD serial signals are 3.3V LVTTL level signals and the TXD signal needs to be set high when the serial interface is idle.
Page 53
Page 54
10 Using the ATOM Config
10.1 Connecting & Safe Shutdown
The GUI requires only two files to operate: AtomConfig.exe and AtomSerialCmdLib.dll (both in the same directory).
10.1.1 Connect to ATOM Config
1. Launch AtomGui from your computer by clicking the AtomGui.exe application file.
2. Select the method of connection via the Interface pull-down menu.
Note: Depending on the number of Camera Link frame grabbers installed in the PC or if the frame grabber supports dual Base configuration, the Serial Port selection may be CAMERALINK0 or CAMERALINK1. There may be multiple cameras connected on a network that are discovered.
3. Click Connect to open camera connection.
4. Click Disconnect to close camera connection.
10.1.2 Safe Shutdown
Before unplugging your camera, be sure to click the Safe Shutdown button. The Safe Shutdown button will disable the detector and close the shutter before you power down the camera. Both actions help preserve camera and detector life.
Page 54
Page 55
10.2 Info Tab
The Info Tab displays hardware & firmware identification numbers, camera status, and the detector temperature (VTEMP).
Refresh the Status, Fault Indicators, and VTEMP values by pressing the Refresh button.
Initiate a self-test operation by pressing the “Self Test” button. This operation can take several minutes during
which the “Image ready” box will not be checked when you refresh the status information. When the test is
complete, “Image ready” will return to the checked state, and any error conditions detected during the test will be
reported among the “Fault indicators.“
Page 55
Page 56
10.3 Video Tab
The Video Tab is used to set the detector window format. The Video Tab can also configure the output video display resolution, output video zoom, output video data resolution, and enable video image correction. The Video Tab can also select from a live image and several test patterns.
10.3.1 Detector Disable
Selecting this checkbox will disable the detector. This is a function that is applied when using the safe shutdown button in order to preserve the detector.
10.3.2 External Sync & Edge Detection
The External Sync Tab is used to control the camera from an external timing source. The primary purpose is to allow the User to control and synchronize the Frame Rate to an external clock and secondarily to align the start of frame integration activity with external events. Full camera performance is achieved at rates approximately equal to the 30Hz frame rate used to calibrate the camera at manufacture time.
Use of the External Sync feature is flexible and can be used to slow the camera down to very low frame rates (e.g. sub 1Hz), with associated compromises in spatial noise performance and speed of 1NUC operations.
The balance of this section describes the signal connectivity, control and timing issues to use the External Sync feature.
The External Sync signal is driven from different access points depending on the I/O configuration. The signal is input is as follows:
In Camera Link camera models, the signal is accessed from the CC1 control line and Pair8 signals on
Camera Link interface). Pair8 signals are connected as follows:
o Camera end Pin 22 (PAIR8+) and Pin 9 (PAIR8-)
Page 56
Page 57
Symbol
Parameter
Min
Max
units X Time between frames
33.332
34.130 (Note 1)
ms
Frame Rate
1/X
29 (Note 1)
30.01
HZ
A
Active Sync edge to Detector
Frame Start
520
600
ns
B
Active Reset pulse edge to start
of Output Video Frame Valid
127.75
408.9
µs
C
Reset pulse to End of Output
Video Frame Valid
-163.55
385.4
µs
D
End of last line Integration to
Reset pulse
183
238.60
µs
o Frame grabber Pin 5 (PAIR8+) and Pin 18 (PAIR8-)
In LVTTL camera models the signal is accessed from J1 pin 13.  The External Sync signal exists in Gigabit Ethernet camera models and can be accessed via the Pleora
SDK as the same CC1 control line described in the Camera Link configurations. However, software control of this signal is impractical for precision timing in most host controlled situations and as a result this configuration is not formally supported. Some useful results may be obtained with specialized host hardware and/or operation at low frame rates, and the determination of successful operation is left to the user.
Figure 2a: External Sync Edge Triggering Timing Diagram with Zoom disabled
Table 7: External Sync Timing Parameters
Note 1: The camera will perform as calibrated within the specified Min to Max frame rate range. Operation higher than this range cannot occur; the rate is capped at the maximum 30.01Hz. Lower operation is possible with caveats of increased spatial noise.
Page 57
Page 58
All four corners aligned
The NUC that limits spatial noise depends on the thermal conditions around the pixels. These conditions include not only camera ambient temperature, but also effects such as the self heating generated by bias current applied during the integration time as well as the cooling that takes place in the interval between integration cycles. While NUC operations compensate for ambient temperature changes, this self heating and cooling is directly influenced by variations in frame rate and is not automatically compensated for in NUC adjustments. As a result, the External Sync control operated at rates below the specification will produce an image, but with increasing gain and offset errors. Offset error can be compensated by 1NUC operations when performed specifically at the Frame Rate driven by the External Sync signal. Failure to 1NUC at the current Frame Rate will result in poor imaging when operated outside the limits.
During a 1NUC operation, the camera accumulates video frames for each pixel’s offset computation. When performed at reduced Frame Rate, this operation takes proportionally longer to complete and may look like a non­responsive system at really low (e.g. < 0.5HZ) external clock rates.
In applications that require minimal system delay, note that enabling the Digital Zoom function adds one Frame delay between Detector and output Video.
10.3.3 Select Image Zoom
From the Video tab, click the bullet next to desired Zoom (1X, 2X, 3X, or 4X). The default value is 1X Zoom.
10.3.4 Zoom Window
The Zoom Window is, by default, turned off. To begin using the Zoom Window, you must align all the edges of the Zoom Window frame to all four corners of the live image (as displayed by the four arrows). Aligning the corners will ensure the accuracy of your crop box.
First, click Move and drag the Zoom frame to align the top left corner of the box. Click Resize, then click and drag the frame box to align the bottom right corner with the live image. Once your box is set, click Crop to select the area you would like to zoom to. To adjust the crop area, simply click Crop again and re-select the area. Once you are satisfied, click Activate to initiate the zoom. If you would like to cancel what you have done with the Zoom Window open, click Cancel.
Page 58
Page 59
Once your zoom area has been set, you may use the up and down arrows next to the text boxes to change the values in order to modify your zoom area. The X and Y values signify the origin of the zoom area, and the W and H signify the width and height of the zoom area, respectively. You may also toggle the zoom window on and off using the “Enabled” check box.
10.3.5 Lens Selection (only for customers purchasing multiple lenses)
This field is only present if your configuration file defines manual lens choices. If you have purchased more than one lens to connect to your ATOM 1024 camera, you would select which lens you are operating with from the dropdown menu.
In the example displayed to the right, a customer has purchased three different lenses; a 13mm, 25mm, and 50mm. When switching lenses, simply select the appropriate lens from the drop-down menu and the appropriate NUC table will be applied.
10.3.6 Setting Output Video Dynamic Range (8-bit or 14-bit)
From the Video tab, click the bullet next to 8 bits per pixel or 14 bits per pixel. The camera will default to be 8 bits per pixel.
Note: When operating in 8-bit mode, the output bits will occupy the most significant bit positions of the parallel output channel, with the unused bit positions set to zero values.
10.3.7 Setting Frame Rate
From the Video tab, click the bullet next to Normal or 1/3 Frame Rate. The Normal Frame Rate is 30hz. Note: Cameras are normally shipped as 30hz default. Special orders can modify factory defaults. The 10hz
option can be used in any interface; however the setting is intended to allow multiple cameras on a single GigE network segment.
10.3.8 Setting Output Correction (Corrected or Uncorrected)
From the Video tab, click the bullet next to Corrected or Uncorrected to enable or disable 1NUC and 2NUC processing. The camera’s default displays the Corrected image.
Note: When operating in 14-bit mode, the output image data will be selectable between uncorrected raw full amplitude resolution, and non-uniformity corrected. In 14 bit mode, palette, gain level adjustments, and zoom are not applied to the output image. In 8-bit mode, the output image data is always gain and level compensated.
Page 59
Page 60
Col Ramp (Black -> White)
Col Ramp (White -> Black)
Row Ramp (Black -> White)
Row Ramp (White -> Black)
10.3.9 Video Source & Test Pattern Selection
From the Video tab, click the bullet next to Test Pattern to change your video source from the Detector to the Test Pattern. There are six Test Patterns you may choose from: All White, All Black, Col Ramp (Black -> White), Col Ramp (White -> Black), Row Ramp (Black -> White), and Row Ramp (White -> Black).
Note: The test patterns are labeled as they appear for a White Hot scene. If you have selected Black Hot from the
Image tab, each test pattern will be reversed.
Page 60
Page 61
10.4 Image Tab
The Image Tab can set the palette, auto or manual gain and level, and AGC cutoff thresholds.
Palette – The Polarity settings configures the video as White-Hot or Black-Hot. The camera defaults to White-Hot. Gain Mode – The gain mode defaults to Automatic Gain. Manual Gain – The Gain setting allows manual gain span control of the digital outputs, similar to image contrast
with visible cameras.
Level Mode – The level mode defaults to Automatic Level. Manual Level – The Level setting allows manual gain level control of the digital outputs, similar to image
brightness with visible cameras. AGC Cold Cutoff The AGC Cold Cutoff specifies the percentage of the coldest pixels to be excluded from the
AGC calculation. AGC Hot Cutoff The AGC Hot Cutoff specifies the percentage of the hottest pixels to be excluded from the
AGC calculation.
10.4.1 Select Palette (White-Hot, Black-Hot)
From the Image tab, select White-Hot or Black-Hot from the Palette pull-down menu.
Page 61
Page 62
All four corners aligned
10.4.2 Setting Manual Gain and Level settings
1. From the Image tab, click the bullet next to Manual for Gain Mode and Level Mode.
2. Edit the value for Manual Gain and Manual Level in the up/down counter box or click and drag the slider.
10.4.3 Setting AGC cutoffs
From the Image tab, edit the value for Cold & Hot AGC Cutoffs in the up/down boxes or click and drag the sliders.
10.4.4 AGC (Automatic Gain Control) Window
The AGC Window is, by default, turned off. To begin using the AGC Window, you must align all the edges of the AGC Window frame to all four corners of the live image (as displayed by the four arrows). Aligning the corners will ensure the accuracy of your crop box.
First, click Move and drag the AGC frame to align the top left corner of the box. Click
Resize, then click and drag the frame box
to align the bottom right corner with the live image. Once your box is set, click
Crop to select the area you would like
AGC to be applied to. To adjust the crop area, simply click Crop again and re-select the area. Once you are satisfied, click Activate to initiate the AGC. If you would like to cancel what you have done with the AGC Window open, click Cancel.
Once your AGC area has been set, you may use the up and down arrows next to the text boxes to change the values in order to modify your AGC area. The X and Y values signify the origin of the AGC area, and the W and H signify the width and height of the AGC area, respectively. You may also toggle the AGC Window on and off using the “AOI Enabled” check box.
Bound Box: If selected, this will draw a box around your AGC Area of Interest
Invert Box: If selected, this will invert polarity of the pixels inside the Bound Box.
Page 62
Page 63
10.5 NUC Tab
The NUC Tab is used to initiate a Touchup (1 pt. NUC), and to enable or disable image processing including video noise reduction. The NUC tab also allows selection of the Auto 1NUC Threshold percentage which if the ambient temperature of the current plateau has changed by more than this percentage, a Touchup is automatically performed.
By default, the shutter mode is set to Automatic. By default, the Median Filter and Freeze Video During
Touchup will be on.
10.5.1 Initiating a Touchup (against the shutter)
1. From the NUC tab, click the “Touchup Now” button.
2. Observe an audible sound of the shutter being closed and opened.
Page 63
Page 64
10.5.2 Initiating a Touchup (through Lens)
1. From the NUC tab, change the Shutter Mode from Automatic to Manual by clicking the bullet next to Manual for Shutter Mode.
2. Place a uniform temperature object in front of the lens.
3. Click the “Touchup Now” button.
4. Remove the uniform object and verify the image.
10.6 Lens Tab (only for CZ lens cameras)
The Lens Tab is used for zoom and focus control with Motorized Continuous Zoom Lens.
The Zoom and Focus may be adjusted different ways:
Clicking the Wide, Mid, or Narrow (or Far &
Close) buttons
Using the up/down Coarse and Fine buttons  Clicking along the zoom or focus bar  Clicking and dragging the cursor across the bar  Manually entering in a value in the text box
Note 1: The changes to the Focus and
Zoom will be immediately reflected. Set All is not necessary to make changes.
Note 2: The NUC tables that are appropriate for selected ZOOM position are automatically selected and loaded when zoom level is changed.
Note 3: The camera will maintain proper Focus position for selected Zoom level until Focus position is manually changed by the user.
Page 64
Page 65
Tab
Field Name
Field Default
Video
Detector Disable
Detector enabled (unchecked)
Enable External Trigger
Disabled (unchecked)
Zoom
1X
Output Bits
8 bits per pixel
Frame Rate
Normal
Output NUC and BP Correction
Corrected
Video Source
Detector
Test Pattern Selection
All White
Edge Detection
Falling Edge
Image
Palette
White Hot *
Gain Mode
Automatic
Level Mode
Automatic
AGC Cutoff – Cold
5
AGC Cutoff – Hot
1
NUC
Enable 1NUC
Enabled
Enable 2NUC
Enabled
Enable BP Replace
Enabled
Enable Auto 1NUC on Plateau
Enabled
Enable Auto 1NUC on Threshold
Enabled
Shutter mode
Automatic
Shutter position
Open
Median Filter
Enabled *
Freeze Video During Touchup
Enabled
Auto 1NUC Threshold
10%
10.7 Default Values
This table shows the power-on defaults for all user controllable settings. The Atom camera will return to these configuration settings every time it is powered on.
* Factory configured: some cameras may have different default setting
Page 65
Page 66
11 Physical Dimensions Drawings
This section contains the physical dimension drawings for each permutation of the ATOM 1024 camera.
11.1 Standard lens Dimensions
11.1.1 Universal Lens Mount Inteface
Page 66
Page 67
Page 67
11.1.2 13mm (f1.1) Manual Focus Lens Dimensions
Page 68
Page 68
11.1.3 25mm (f1.2) Athermal Fixed Focus Lens Dimensions
Page 69
Page 69
11.1.4 50mm (f1.2) Athermal Fixed Focus Lens Dimensions
Page 70
Page 70
11.1.5 50mm (f1.0) Manual Focus Lens Dimensions
Page 71
Page 71
11.2 ATOM 1024-20 C Model Physical Dimensions
Note: Drawing displays the model without a lens mounted.
Page 72
Page 72
11.3 ATOM 1024 G Model Interface Physical Dimensions
Note: Drawing displays the model without a lens mounted.
Page 73
Page 73
11.4 ATOM 1024 L Model Interface Physical Dimensions
Note: Drawing displays the model without a lens mounted.
Page 74
Page 74
11.5 ATOM 1024 G (CZ 25-225mm) Model Interface Physical Dimensions
Page 75
Page 75
11.6 ATOM 1024 G (CZ 25-150mm) Model Interface Physical Dimensions
Page 76
Page 76
11.7 ATOM 1024 G (CZ 15-100mm) Model Interface Physical Dimensions
Page 77
Infrared Engine Model
ATOM 1024
FPA
Uncooled ASi Microbolometer
Size
1024 x 768
Pixel Pitch
17 µm
Frame Rate (full frame)
30 Hz
Thermal Time Constant
< 10 ms
Digital Output
LVTTL (L model), Gigabit Ethernet (G model), Camera Link (C model)
Size: (W x H x D) (w/o lens, Camera Link option)
61 x 69 x 66mm (2.4” x 2.7” x 2.6”)
Weight (w/o lens, LVTTL option)
< 250g
Weight (w/o lens, Camera Link option)
<390g
Weight (w/o lens, Gigabit Ethernet option)
<500g Input Voltage
6 – 12 VDC
Power Consumption
< 1.7W LVTTL; < 2.2W Camera Link < 3.6W Gigabit
Ethernet
Detector Thermal Sensitivity1
< 50 mK
Time to First Image
< 4 sec
Video Processing
Non-uniform Correction
Operational Temperature
-40°C to 60°C
Non-operation Temperature
-45°C to 70°C
12 Specifications
1
Normalized to unity transmission and f1.0 lens
Page 77
Page 78
13 Maintenance
13.1 Cleaning
13.1.1 Non-Optical Surfaces
The non-optical surfaces of the ATOM 1024 Camera can be cleaned with water, mild detergents, and a soft cloth.
13.1.2 Optical Surfaces
The optical surfaces of the lens should only be cleaned when visibly dirty. Care should be taken to avoid touching the exposed lens faces. Skin acid left behind with fingerprints can be damaging to coatings and lens substrates.
First use a jet of dry air or blow across the surface to remove any sand or abrasive particles before cleaning. If oil, water spots, or fingerprints form on the optical surfaces, clean as soon as possible using a soft cotton cloth and mild neutral soap diluted with lukewarm distilled water (1 part soap to 100 parts water), followed by reagent-grade isopropyl alcohol or acetone swab. Dust can be removed gently using an alcohol or acetone swab.
Note: Avoid swabs that incorporate plastic stems, as some plastics will dissolve in alcohol or acetone.
13.2 Replacing Components
There are no user serviceable parts inside the camera. For service, please contact Sofradir-EC.
14 Warranty
1) Seller warrants that at the time of delivery to the carrier, the Products are free from defects in material and workmanship. Any warranty described herein shall extend to the first ultimate user only for a period of one year from the date of shipment from Seller's factory except as otherwise stated in our written quotation.
2) Seller's obligation under this warranty shall be limited to furnishing a replacement for, or at Seller's option, repairing any part that, to the Seller's satisfaction, proves defective, provided such part is returned to the Seller's service facilities in New Jersey, all transportation charges paid (including freight, insurance, customs, duties, taxes, etc.). No part may be returned without Seller's prior return authorization approval.
3) Seller shall not be responsible for installation costs. In no event will any claim for labor in removing or replacing defective parts or for incidental or consequential damages be allowed.
Page 78
Page 79
4) No warranty is made as to Products which have not been installed, operated or maintained in accordance with Seller's instructions or the instructions contained in its operations or maintenance manuals when furnished by Seller, or which have been subject to misuse, abuse, accident or alteration or to improper or negligent use, maintenance, storage, transportation or handling.
5) Products not manufactured by Seller which are sold by Seller are covered exclusively by the original manufacturer's warranty and Seller may, at its option, assign to Buyer its warranty claims against the original manufacturer of defective Products in full settlement of Buyer's possible claims against Seller with regard to such Products.
6) Where Buyer is a distributor, financing company or similar entity acting for or on behalf of the initial user of the equipment, the warranty is transferable to the initial user only. In all other cases, the warranty is limited to the Buyer and is not transferable unless agreed to in writing by the Seller.
7) Caveat Emptor: The Warranty contained herein is exclusive and expressly in lieu of all other warranties, written, oral, implied or statutory, including but not limited to express or implied warranties of merchantability or of fitness. In addition, Seller shall not be liable for any loss, damage or injury of any nature, whether direct, indirect or consequential, in connection with or resulting from use of the Products.
15 Repairs
15.1 Returning Products for Warranty Repair
Return the product to your Authorized Dealer. Dealer will notify the service department by telephone before returning any product.
OR
Contact the manufacturer directly through the phone number and address provided on the contact sheet at the end of this booklet.
A Return Authorization (RA) number will be assigned by the service department. This number must be marked clearly on the outside of the package being returned.
Service department will provide a shipping address.
The following information must be included on the packing slip: Model and serial number of camera Your shipping address Your billing address (if different) Your fax, telephone numbers and/or email address Description of the problem Name of the point of contact Return authorization number
Page 79
Page 80
Repaired equipment will be returned prepaid (surface freight only). If goods are being returned from outside the United States, the shipper is responsible for all customs and brokerage charges.
15.2 Returning Products for “Out of Warranty” Repair
Following expiration of the warranty period, the owner is financially obligated to pay for any repairs that are required. The owner may either return their camera to their dealer, or, they may work with the manufacturer directly. If you choose to deal directly with the manufacturer, you may contact us through the phone number and address provided in the Contact Information section at the end of this booklet.
You are required to provide the following information: Model and serial number of camera Your shipping address Your billing address (if different) Your fax, telephone numbers and/or email address Description of the problem Name of the point of contact Return authorization number
You will be asked for payment of an evaluation fee prior to us starting work. Following evaluation, when the extent of the repairs is known, the manufacturer will contact you and estimate the total cost of the repair. If you choose not to have the repair completed, you will still be liable for the evaluation fee. If you choose to authorize the repair, the camera will be repaired and returned following receipt of payment.
16 Contact Information
Sofradir-EC Incorporated 373 Route 46 West Fairfield, NJ 07004 USA
Telephone: (973) 882-0211 Fax: (973) 882-0997 E-mail: service@sofradir-ec.com
Page 80
Loading...