REQUIREMENTS Feeder measurement & control
Energy breakdown & allocation Load analysis & management Event monitoring Detection & storage of network perturbations Form factor
DIRIS A10 DIRIS A20 DIRIS A40 / A41 DIRIS A60
4 modules panel mounted 96x96 panel mounted 96x96 panel mounted 96x96
Functions
MEASUREMENT Currents, voltages, frequency, active, reactive and apparent power, power factor Predictive power Voltage/current unbalance; Tangent Temperature(s) Average currents, voltages and frequency Average power ENERGY MANAGEMENT Energy meters (cl. 0.5S IEC 62053-22; cl. 2 IEC 62053-22) Pulse meter Load curves QUALITY ANALYSIS AND EVENT DETECTION THD 3U, 3V, 3I/In Individual harmonics 3V, 3U, 3I/In (level 63) Sag, swell and outages, overcurrent RMS 1/2 period curve backup Alarm output MEASUREMENT AND EVENT HISTORY Load curves Events & Alarms Maximum average power Maximum average currents
* 1 configurable
References
>
DIRIS A10
DIRIS A10 DIRIS A10 with RS485 Jbus/Modbus communication
>
DIRIS A20
DIRIS A20 110 to 400 V AC and 120 to 350 V DC supply
Module 1 output 4825 0080 RS485 JBUS/MODBUS communication module 4825 0082
>
DIRIS A40 / A41
DIRIS A40 110 to 400 V AC and 120 to 350 V DC supply DIRIS A40 12 to 48 V DC supply DIRIS A41 110 to 400 VAC and 120 to 350 VDC supply DIRIS A41 12 to 48 VDC supply
>
DIRIS A60
DIRIS A60 110 to 400 V AC and 120 to 350 V DC supply
4825 0010 4825 0011
4825 0200
4825 0201 4825 1201 4825 0202 4825 1202
4825 0207
DIRIS A10 DIRIS A20 DIRIS A40 / A41 DIRIS A60
1…4 option 1…4 option
1* 2…6 option 2…6 option
level 51 level 51 level 63 level 63
1* 1* option 2…6 option 2…6 option
kW kW
in option
-/
•/•
>
Module option: DIRIS A40 / A41 / A60
Pulse outputs module 4825 0090 RS485 JBUS/MODBUS communication module 4825 0092 RS485 PROFIBUS-DP communication module 4825 0205 Ethernet Module 4825 0203 Ethernet module with RS485 gateway 4825 0204 Temperature module 4825 0206 Analogue outputs module 4825 0093 Monitoring or control/command module 4825 0094 Memory module (DIRIS A40/A41) Functional earth module 4825 0087
4825 0097
Associated current transformers
Primary
wound CT
T2RB
TRB
Accuracy
0,2s version
W
H
D
d
cable d (mm) 21 22,5 18 22 17.5 26 28 32 44 44 85 100 20 50 80 80
W
bar x 1 (mm) 20x5 30x10 20x5 30x10 30x10 40x10 50x12 63x10 123x30 20x30 50x80 80x120 80x160
H
bar x 2 (mm) 20x10 30x5 40x10 50x10 100x10 bar x 3 (mm) 80x10 100x10
Primary (A)
Secondary (A) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5
0,5 0,5-1 1 1 1 0,5-1 0,5-1 0,5-1 0,5-1 0,5-1 0,5 0,5 0,5-1 0,5 0,5 0,5
H (mm)
88.5
W (mm)
D (mm)
5 ... 4025 ...
150
Others types of transformers in our catalogue.
Through cable CT
TCA 21T2CA
115
• 115 100
50 ... 300
225
78,5
150 ... 600
Three phase Bar or cable-through CT Split-core CT
TCB3
18-20
115
100 ... 250 250 ... 600
TCB3
22-30
150
TCB
17-20
49.5 50
60 ... 400
TCB
26-30
78,5
50 ... 750
TCB
28-30
49.9 68
50 ... 600
TCB
32-40
88.5 71 58
50 ... 1000
TCB
44-50
101.5 86 58
100 ... 1250
TCB
44-63
108.5 96 58
200 ... 1600
TCB
85-100
187.5 172
750 ... 3000
TCB
T0 23 TO 58 TO 812 TO 816
100-125
187.5
106
100 ... 400
152 125
250 ... 1000
172
1000 ... 4000
198
246
155
250 ... 1500
195
1000 ... 5000