SOCOMEC - Ref. : 875 645 D
3
PRELIMINARY OPERATIONS
1
2
4
3
For personnel and product safety
please read the contents of these
operating instructions car
Check the following points as soon as
you receive the package:
• the packing is in good condition,
GENERAL INFORMATIONS
The COUNTIS System comprises
energy metering products for balanced
or non-balanced 3- or 4-wire network.
This system comprises two products:
Tv2
• A
• ATiv2: a three-phase insulated single
: a non-insulated thr
active energy-meter, which does not
allow earthing CT of secondary.
or double rate active energy meter
allowing the CT secondary to be
earthed.
efully.
ee-phase
• the product has not been damaged
during transit,
the product reference number con-
•
forms to your order,
• the package contains the product as
well as the operating instructions.
These products are completely configurable (CT radio, network type and
pulse output value) and have a 7-digit
display which allows direct display of
consumption in kWh. They ar
e equip-
ped with a pulse output as standard.
PRESENTATION
COUNTIS ATv2 / ATiv2 SINGLE RATE
COUNT 105 A
a kWh display
b Total and partial meter display
, or scr
olling parameter settings
c Flashing LED consumption indicator (10 Wh/pulse)
d Validation/scrolling of parameter settings
4
SOCOMEC - Ref. : 875 645 D
PRESENTATION (continued)
1
2
5
4
3
COUNTIS
COUNT 119 B
ATiv2 DOUBLE RATE
a kWh display
b Total and partial meter display, or scrolling parameter settings
c Displays t1 and t2 rate meters
d Flashing LED consumption indicator (10 Wh/pulse)
ENG LI S H
INSTALLATION
Note:
The COUNTIS can be installed on a
DIN EN 50022 rail (DIN 43880).
Recommendation:
• Avoid close proximity with systems
generating electromagnetic distur
bances
• Avoid vibrations including accelerations of mor
cies lower than 60 Hz.
Note:
The minimum torque for the fixed
terminal is 0.8 Nm.
Recommendation:
We recommend that the auxiliary
voltage and the voltage inputs should
be protected with 0.5 A fuses or
BS 88 2A gG.
e than 1 G for frequen-
e Validation/scrolling of parameter settings
CLIMATIC ENVIRONMENT
o guarantee optimum operation, it is
T
ecommended that this device is used
r
between - 5 to + 45 °C with a relative
humidity of between 20 and 85
-
%.
CONNECTION
The Countis A
Tv2 and A
connection terminals of 1 to 6 mm
Tiv2 consist of
2
for
currents and voltages.
I, F)
SAFETY INSTRUCTIONS (U
,
To avoid damaging the device, take
care to observe the following before
connecting the device:
• indications on the casing,
• network fr
• maximum permanent voltage at
voltage input terminals of 400 V AC
20
±
equency: 50 or 60
%
phase/phase,
Hz,
• maximum permanent current of 7 A
(connection fr
mer(s)).
om curr
ent transfor
-
SOCOMEC - Ref. : 875 645 D
5
L
1
L
2
L
3
P
1
S
1
P
1
S
1
P
1
S
1
2
4
6
8
1
3
5
7
9
11
ATiv2
1
L
1
L
2
L
3
P
1
S
1
P
1
S
1
2
4
6
8
1
3
5
7
9
11
ATiv2
1
L
1
L
2
L
3
P
1
S
1
A
Tiv2
2
4
6
8
1
1
3
5
7
9
11
L
1
L
2
L
3
P
1
S
1
P
1
S
1
2
4
6
8
1
3
5
7
9
11
ATiv2
1
L
1
L
2
L
3
N
P
1
S
1
P
1
S
1
P
1
S
1
2
4
6
8
1
3
5
7
9
11
ATiv2
1
L
1
L
2
L
3
N
P
1
S
1
2
4
6
8
1
3
5
7
9
11
A
Tiv2
1
L
1
L
2
P
1
S
1
2
4
6
8
1
3
5
7
9
11
ATiv2
1
L
1
N
P
1
S
1
2
4
6
8
1
3
5
7
9
11
ATiv2
1
INSTALLATION (continued)
External counter
1
3
5
7
9
11
External power supply
4
6
2
8
10
12
14
t1 = 0 VAC
4
6
2
8
10
1
3
5
7
9
11
t2 = 230 VAC
NETWORK
Note:
If the current is badly connected or
there is poor current/voltage correspondence (negative energy) the counter will be stopped and the arrows t
flash.
CT earthing, for the ATiv2 only
3 WIRE WITH 1 CT (3 BL)4 WIRE WITH 1 CT (4 BL)
COUNT 106 C
3 WIRE WITH 2 CT (3 NBL)3 WIRE WITH 2 CT (3 NBL)
COUNT 108 C
COUNT 107 C
COUNT 109 C
Key to diagrams:
1 Fuses 0.5 gG or BS 88 2A gG
3 WIRE WITH 3 CT (3 NBL)4 WIRE WITH 3 CT (4 NBL)
COUNT 110 C
COUNT 111 C
TWO-PHASE (2 BL)SINGLE-PHASE (1 BL)
COUNT 112 C
RATE INPUT (t1 / t2)
COUNT 118 C
CONNECTING PULSE OUTPUT
The neutral has to be
connected for the dual
tarif ATiv2.
6
COUNT 147A
COUNT 35B GB
SOCOMEC - Ref. : 875 645 D
CONFIGURATION
:
Note
The device will automatically leave
the configuration menu if no buttons
are pressed for a period of 25
seconds.
Note:
Press the t button for a prolonged
period to scroll rapidly through the
configuration scr
short period to scroll through each
screen one-by-one.
eens. Press for a
KEYINSTRUCTION
+
For 3 seconds to access
access-code entry (CdE).
To enter code 21.
o validate the code and access to
T
the network programming (nET).
:
Note
A long press on the button t causes
rapid scrolling and a single short
press causes scrolling in steps of 5.
Note:
The values available depend on the
Ct ratio.
To select the network type, 1bL
(single phase), 2bL (two-phase),
3-4 nbL (unbalanced three-phase)
and 3-4 bL (balanced three-phase).
To validate the network programming
and go on to the current transformer
(CT) primary value.
o programme the primary value up
T
to 6000 A.
To validate the unit programming and
go on to the pulse output (PuLSES).
To go on to the weight of this output
(VAL).
To select the weight “0.1” for
kWh, “1” for 1 kWh, “10” for
0.1
kWh, “100” for 100
10
kWh.
ENG LI S H
SOCOMEC - Ref. : 875 645 D
To validate the programming of this
weight and go on to the pulse
duration (dur).
To select the duration from 60 to
900 ms.
To accept value and pass to partial
meter zero reset (rSET).
o select ‘rSEt nO’ (no reset to zero)
T
and ‘rSEt YES’ (reset to zero).
To confirm reset to zero and return to
network type pr
+
To confirm and quit programming.
ogramming.
7
TECHNICAL CHARACTERISTICS
ENCLOSURE
Connectionvia 1 to 6 mm2terminal shrouds
Weight300 g
Size
Protection class (front)IP40
FRONT PANEL
Green LCD/7 digits
Digit height8 x 4 mm
INPUTS
modular: 4 modules of 17.5 mm
Note:
The current inputs are insulated on
the ATiv2.
Note:
The Countis ATv2 and ATiv2 are autopowered from the V1 et V2 voltage
inputs.
CURRENT
Via transformer with
• configurable primary5 to 6000 A
• secondary5 A
Input consumption10 mA to 7 A (secondary)
Consumption≤ 1 VA
TENSION
Measurement range (Line/Line)230 V AC - 15% to 400 V AC + 20 %
Consumption≤ 0,5 VA
AUXILIARY POWER SUPPLY
Typeauto-powered
DC
/
10
1 VA
mA
Consumption≤
ACCURACY
Accuracy indexIEC 61036 class 1
PULSE OUTPUT
Reed relay (100 V DC - 0.5 A - 12 VA)
Pulse duration
Maximum tripping number
5 x 10
7
at 10 V
60 to 900 ms
TING CONDITIONS
OPERA
Operating temperature- 5 °C up to 45 °C
Storage temperature- 20 °C up to 70 °C
%
Relative humidity
STANDARDS
CE marking
Operating conditions
8
IEC 61000-4
SOCOMEC - Ref. : 875 645 D
/2-3-4-5-6-8-11
EN 50081-1
EN 50082-2
IEC 60068-2-6
IEC 60068-2-11
IEC 60068-2-30
85
ENG LI S H
SOCOMEC - Ref. : 875 645 D
9
SOCOMEC - Ref.: 875 645 D - 10/03
Industrial Switching & Protection Systems
www.socomec.com
COUNT 113 C
HEAD OFFICE
SOCOMEC GROUP
Switchgear and UPS
S.A. capital de 11 052 200 €
R.C. Strasbourg 5484500 149 B
SOCOMEC
1, rue de Westhouse - B.P. 10
F-67235 Benfeld Cedex - FRANCE
Tel. +33 (0)3 88 57 41 41 - Fax +33 (0)3 88 57 78 78