1. Product and Company Identification
Important Note: As a solid, manufactured article, exposure to hazardous ingredients is not expected with
normal use. This battery is an article pursuant to 29 CFR 1910.1200 and, as such, is not subject to the
OSHA Hazard Communication Standard requirement. The information contained in this Material Safety
Data Sheet contains valuable information critical to the safe handling and proper use of the product. This
MSDS should be retained and available for employees and other users of this product.
Commercial product name
INR18650-25R
Use of the substance/preparation
Lithium-Ion battery
Manufacturer
SAMSUNG SDI Co., LTD
Address
HQ: 150-20, Gongse-ro, Giheung-gu, Yongin-si, Gyeonggi-do, Korea
Company/undertaking identification
Emergency Contact(Chemtrec)
1-800-424-9300: US and Canada / 1-703-527-3887: International
Further Information
Battery-System: Lithium-Ion (Li-ion)
Nominal Voltage: 3.6 V
Rated Capacity: 2.5 Ah
Wh rating: 9.00 Wh
Anode (negative electrode): based on intercalation graphite
Cathode (positive electrode): based on lithiated metal oxide (Cobalt, Nickel, Manganese)
Remark:
The information and recommendations set forth are made in good faith and believed to be accurate as of
the date of preparation. SAMSUNG SDI Co., Ltd. makes no warranty, expressed or implied, with respect
to this information and disclaims all liabilities from reliance on it.
2. Hazards Identification
Route(s) of Entry
There is no hazard when the measures for handling and storage are followed.
Signs and Symptoms of Exposure
In case of cell damage, possible release of dangerous substances and a flammable gas mixture.
Page 1 of 8
![](/html/71/71d3/71d35aa4d1254c5ecae0e468b75a0168b065fb407b15c4f474e5fa0be79eb8f3/bg2.png)
SAMSUNG SDI Co., LTD
Polyvinylidene fluoride (PVdF)
Aluminium and inert materials
Date: March 27, 2014 Revision no.: 00
MODEL INR18650-25R
OSHA Hazard Communication: This material is not considered hazardous by the OSHA Hazard
Communication Standard 29CFR 1910.1200.
Special hazards for human health and environment
There is no hazard when the measures for handling and storage are followed.
In case of cell damage, possible release of dangerous substances and a flammable gas mixture.
3. Composition/information on ingredients
Hazardous components
Full text of each relevant R phrase can be found in heading 16.
Further Information
For information purposes:
(*) Main ingredients: Lithium hexafluorophosphate, organic carbonates
Because of the cell structure the dangerous ingredients will not be available if used properly.
During charge process a lithium graphite intercalation phase is formed.
Mercury content: Hg < 0.1mg/kg
Cadmium content: Cd < 1mg/kg
Lead content: Pb< 10mg/kg
4. First Aid Measures
General information
The following first aid measures are required only in case of exposure to interior battery components after
damage of the external battery casing.
Undamaged, closed cells do not represent a danger to the health.
After inhalation
Page 2 of 8
![](/html/71/71d3/71d35aa4d1254c5ecae0e468b75a0168b065fb407b15c4f474e5fa0be79eb8f3/bg3.png)
SAMSUNG SDI Co., LTD
Date: March 27, 2014 Revision no.: 00
MODEL INR18650-25R
Ensure of fresh air. Consult a physician.
After contact with skin
In case of contact with skin wash off immediately with plenty of
water. Consult a physician.
After contact with eyes
Rinse immediately with plenty of water, also under the eyelids, for at least 15
minutes. Seek medical treatment by eye specialist.
After ingestion
Drink plenty of water.
Call a physician immediately.
5. Fire Fighting Measures
Suitable extinguishing media
Cold water and dry powder in large amount are applicable.
Use metal fire extinction powder or dry sand if only few cells are involved.
Special hazards arising from the chemical
May form hydrofluoric acid if electrolyte comes into contact with water.
In case of fire, the formation of the following flue gases cannot be excluded:
Hydrogen fluoride (HF), Carbon monoxide and carbon dioxide.
Protective equipment and precautions for firefighters
Wear self-contained breathing apparatus and protective suit.
Additional information
If possible, remove cell(s) from fire fighting area. If heated above 125°C, cell(s) can explode/vent. Cell is
not flammable but internal organic material will burn if the cell is incinerated.
6. Accidental Release Measures
Personal precautions
Use personal protective clothing.
Avoid contact with skin, eyes and clothing.
Avoid breathing fume and gas.
Environmental precautions
Do not discharge into the drains/surface waters/groundwater.
Methods for cleaning up/taking up
Take up mechanically and send for disposal.
7. Handling and Storage
Handling
Advice on safe handling
Avoid short circuiting the cell. Avoid mechanical damage of the cell. Do not open or disassemble.
Advice on protection against fire and explosion
Keep away from open flames, hot surfaces and sources of ignition.
Page 3 of 8