Snell & Wilcox IQOTR30 Operator's Manual

IQOTR30
Single Mode Fiber Optic Transceiver for
3G/HD/SD-SDI Signals
Snell & Wilcox Ltd., Southleigh Park House, Eastleigh Road, Havant, Hants, PO9 2PE, United Kingdom.
For General Enquiry's contact: Tel: +44 (0) 2392 489000 Fax: +44 (0)23 9245 1411
For Technical assistance contact: Tel: +44 (0) 2392 489058 Fax: +44 (0) 2392 489057
Ftp: ftp://ftp.snellwilcox.com/support
© May 2009
Operator’s
Manual
Version 1 Issue 1 www.snellgroup.com IQOTR30
i
Contents
Module Description....................................................................................................................... 1
Rear Panel Views............... .... ... .................................................................................... ... ............ 2
IQOTR30 Rear Panel View...................................................................................................... 2
Order Codes................................................................................................................................. 3
Feature Summary......................................... ... .... ... ... ... .......................................... .... ... ... ............ 3
Technical Profile........................................................................................................................... 4
Warnings....................................................................................................................................... 7
Notes ............................................................................................................................................ 7
Connections.................................................................................................................................. 8
IQOTR30 Connections ...................................................... ... .... ... .......................................... .. 8
Card Edge Controls............ .... ... .......................................... ... ... ................................................... 9
IQOTR30 ................................................................................................................................. 9
Controlling the IQOTR30 from the RollCall Control Panel.......................................................... 10
Unit Status............................................................................................................................. 10
Input....................................................................................................................................... 11
Memory 1-16.......................................................................................................................... 13
Logging.................................................................................................................................. 14
RollTrack................................................................................................................................ 17
Setup ..................................................................................................................................... 19
Operation from an Active Control Panel ..................................................................................... 21
Information Window............................................................................................................... 21
Control Window .............................................................. ... ... .... ............................................. 21
Manual Revision Record............................................................................................................. 22
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 1
Module Description
The IQOTR30 is a fiber optic transceiver for bi-directional conversion of 3Gbps, HD and SD-SDI signals to 1310 nm wavelength optical signals.
Networkcontrolmonitoringintelligence,andBuilt-in
Intelligence
SDI TX
1
1
2
SDI RX
Signal
Equalisation
Fiber
Optic
Transmitter
CH 1 Fiber
Laser
Status
Monitor
I
n p u t
s
O u
t
p u t
s
SDI TX
CH 2 Fiber
Fiber RX
Input Light
Detect
Monitor
2
1
Re-clocker
Rate
Detection
Re-clock Bypass
Re-clocker
Rate
Detection
Re-clock Bypass
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 2
Rear Panel Views
IQOTR30 Rear Panel View
TX OUT
SDI OUT 1
IQOTR30
33-1A
2
1
SDI IN
RX SDI OUT
2
1
RX IN
These modules can only be fitted into ‘A’ style enclosures as shown below.
Enclosure order codes IQH3A-S-0, IQH3A-S-P
Enclosure order codes IQH3A-E-0, IQH3A-E-P, IQH3A-0-0, IQH3A-0-P
Enclosure order code IQH1A-S-P
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 3
Order Codes
Feature Summary
Reclocking for 3 Gbit/s, 1.5 Gbit/s HD-SDI and 270 Mbit/s SDI signals, or asynchronous operation for other frequencies (input range 50 Mbit/s to 3 Gbit/s)
Single mode fiber optic Transmitter for 3G/HD/SD-SDI and DVB ASI Signals
Output wavelength of 1310 nm
Active loop-through 3G/HD/SD-SDI outputs for each input in accordance with SMPTE424M, SMPTE292M, SMPTE259M and DVB ASI
Single mode fiber optic receiver for 3G/HD/SD-SDI and DVB ASI Signals
Input wavelength range 1260-1620 nm
3G/HD/SD-SDI outputs for CH 2 optical input, in accordance with SMPTE424M, SMPTE292M, SMPTE259M and DVB ASI
IQOTR30 IQOTR3033-1A
Single mode fiber optic transceiver for HD/SD-SDI. 1 x HD/SD­SDI input, 2 x HD/SD-SDI outputs, 1 x optical output. 1 x optical input, 2 x HD/SD-SDI outputs
IQOTR3033-1A3
Single mode fiber optic transceiver for 3G/HD/SD-SDI. 1 x 3G/ HD/SD-SDI input, 2 x 3G/HD/SD-SDI outputs, 1 x optical output. 1 x optical input, 2 x 3G/HD/SD-SDI outputs
IQOTR30-3G
Upgrade for IQOTR30 Single mode fiber optic transceiver to operate with 3Gbps signals
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 4
Technical Profile
Inputs and Outputs Signal Inputs (Tx)
Electrical 3 GBit/s HD-SDI, 1.485 GBit/s HD-SDI or 270 Mbit/s SD-SDI (asynchronous
operation available at other frequencies) Connector / Format BNC / 75 ohm panel jack Conforms to SMPTE 424M (HD level A)
SMPTE 292M (HD)
SMPTE 259M-C (SD) Inputs 1 Input Cable Length Up to 80m Belden 1694A @ 3 Gbit/s
Up to 180m Belden 1694A @ 1.5 Gbit/s
Up to 350m Belden 1694A @ 270 Mbit/s
Signal Inputs (Rx)
Optical 3 GBit/s HD-SDI, 1.485 GBit/s HD-SDI or 270 Mbit/s SD-SDI (asynchronous
operation available at other frequencies) Connector / Format SC/PC singlemode panel uniter Standard SMPTE 297-2006 Input 1
Signal Outputs (Tx)
Optical 3 GBit/s HD-SDI, 1.485 Gbit/s HD-SDI or 270 Mbit/s SD-SDI (asynchronous
operation available at other frequencies) Connector / Format SC/PC singlemode panel uniter Outputs 1 per channel Conforms to SMPTE 297-2006 Electrical 3 GBit/s HD-SDI, 1.485Gbit/s HD-SDI or 270 Mbit/s SD-SDI (asynchronous
operation available at other frequencies) Connector Format BNC/ 75 ohm panel jack
(Reclocked active loop through) Outputs 2 reclocked active loop through for CH1 SDI Input
1 reclocked active loop through for CH2 SDI Input Conforms to SMPTE 424M (HD level A)
SMPTE 292M (HD)
SMPTE 259M-C (SD)
Signal Outputs (Rx)
Electrical 3 GBit/s HD-SDI, 1.485 Gbit/s HD-SDI or 270 Mbit/s SD-SDI (asynchronous
operation available at other frequencies) Connector / Format BNC / 75 ohm panel jack
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 5
Conforms to SMPTE 424M (HD level A)
SMPTE 292M (HD)
SMPTE 259M-C (SD)
DVB/ASI (output 1 only) Outputs 2 outputs
Controls Card Edge Controls (also available via RollCall)
None
Functions Available via RollCall Only
Mode Auto, 3G, HD, SD Reclocker On/Off Laser Disable On/Off Rx Input Status Present, Loss/Unknown, Data Rate Logging Input 1 (2) Type
Input 1 (2) Data Rate
Input 1 (2) Present
Input 1 (2) Error
Input 1 (2) Loss
Tx Laser Bias High Warning
Tx Power Low Warning
Tx Power High Warning
Tx Laser Wavelength
Rx Power High Warning
Rx Power Low Warning
Rx Power Measurement RollTrack Controls On/Off, Index, Source, Address, Command, Status, Sending. RollTrack Outputs Unused
Input 1 (2) Present
Input 1 (2) Rate Unknown
Input 1 (2) Loss
Input 1(2) 3G
Input 1(2) HD
Input 1(2) SD
Tx Laser Bias High Warning
Rx Power High Warning
Rx Power Low Warning
Indicators
Power OK (Green) CPU OK (Green flashing) Input 1 (2) OK (Green), Bypass (Orange), Loss (Red)
Specifications Optical Outputs (Tx)
1310 nm Tx
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 6
Wavelength 1310 nm Spectral width
(FWHM)
>1.5 nm (typ)
Output power -2 dBm (±1 dBm) Extinction ratio >7.5:1 (typ) Transmission
distance
Up to 30 Km
Optical Inputs (Rx)
Input wavelength range
Min. 1260 nm
Max. 1620 nm Optical power input
range
> -3 dBm
< -18 dBm Detector damage
threshold
+3.5 dBm
Module Power Consumption
3.5W max
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 7
Warnings
All lasers used in this product are Class 1, in accordance with EN60825-1 as well as 21CFR 1040.10 and 1040.11
Laser light can be damaging to the eyes. Optical fibers and u niters sh ould be handled with great care.
The IQOTR30 is designed for use with Class 1 laser systems only. Ensure tha
t all outputs do not exceed Class 1 as doing so will impair the safety of the
system and may result in damage to the equipment.
Active fibers should not be handled unless thier source can positively be identified
as not exceeding Class 1 limits.
Notes
Note:
Optical uniters have shutters to prevent the ingress of dust. These shutters should only be opened when connecting optical fibe rs .
The ends of optical fibers should be clea
ned with a liquid fiber cleaner, using a cotton bud, to ensure that there is no dust present before they are plugged in (the uniter is polarized).
Do not disturb or handle the optical fibers.
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 8
Connections
IQOTR30 Connections
Optical Input (RX IN)
Optical input (Rx IN) to the module is via a single SC/PC singlemode panel uniter.
Electrical Input (SDI IN)
Electrical input (SDI IN) to the module is via a single BNC 75 ohm panel jack connector.
Optical Output (TX OUT)
There is a single optical output from the unit via an SC/PC singlemode panel uniter. The input source for this output is the SDI IN connector.
Electrical Outputs (SDI OUT 1)
There are two serial digital outputs via BNC 75 ohm panel jack connectors. The input source for these outputs is the SDI IN connector.
Electrical Outputs (RX SDI OUT)
There are two serial digital outputs via BNC 75 ohm panel jack connectors. The input source for these outputs is the RX IN connector.
TX OUT
SDI OUT 1
IQOTR30
33-1A
2
1
SDI IN
RX SDI OUT
2
1
RX IN
TX OUT
SDI OUT 1
IQOTR30
33-1A
2
1
SDI IN
RX SDI OUT
2
1
RX IN
TX OUT
SDI OUT 1
IQOTR30
33-1A
2
1
SDI IN
RX SDI OUT
2
1
RX IN
TX OUT
SDI OUT 1
IQOTR30
33-1A
2
1
SDI IN
RX SDI OUT
2
1
RX IN
TX OUT
SDI OUT 1
IQOTR30
33-1A
2
1
SDI IN
RX SDI OUT
2
1
RX IN
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 9
Card Edge Controls
IQOTR30
OKWARNINGERROR
POWER OK
CPU OK
OKWARNINGERROR
CH1 CH2
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 10
Controlling the IQOTR30 from the RollCall Control Panel
Unit Status
Information about the status of the unit is displayed in the Unit Status section on each RollCall Control Panel screen.
The first two lines of the Unit Status display the input status, detected rate, and input selection method for Input 1.
The third and fourth lines of the Unit St atus display the same inform ation for Input
2.
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 11
Input
The input screen enables the type of input signal to be selected.
Input 1 SDI Rate (SDI IN 1) / Input 2 SDI Rate (RX IN 2)
Auto: When selected, the unit will automatically detect and reclock any valid input signal, and the detected rate will be displayed in the Unit Status.
If anything else is detected, the output will not be reclocked. If the On Input
Loss / Mute option is selected, the output will be muted; or, if the On Input Loss / Pass option is selected, the output will be passed through.
SD/DVB-ASI (270 Mb): When selected, the unit will reclock only SD/DVB­ASI (270 Mb) signals.
When selected, the On Input Loss controls are greyed out and are inactive. If any other standard is applied to the unit, the output will be muted.
HD (1.5 Gb): When selected, the unit will reclock only HD (1.5 Gb) signals. When selected, the On Input Loss controls are greyed out and are inactive.
If any other standard is applied to the unit, the output will be muted.
3G (3 Gb): When selected, the unit will reclock only 3G (3 Gb) signals. When selected, the On Input Loss controls are greyed out and are inactive.
If any other standard is applied to the unit, the output will be muted.
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 12
Reclock Bypass: When selected, the unit will not reclock the input signal. If a supported rate is detected, the Unit Status will display the detected rate, otherwise, *** will be displayed.
If the On Input Loss / Mute option is selected, the output will be muted whenever a recoginized rate is not detected; or, if the On Input Loss / Pass option is selected, any signal standard, frequency, etc… will pass through.
Output 1 / Output 2
Mute: When selected, this option applies a mute on the output
On Input loss / Mute: When selected, if the Input signal is lost, the output signal will be muted.
On Input loss / Pass: When selected, if the input signal is lost, it will be passed unchanged.
Fiber Optic Tx 1
This section displays the following information about the fiber optic output signal:
Tx Wavelength
Laser Bias
Laser Bias State
Tx Power
Tx Power State
Laser OFF: Selecting this option disables the laser.
Laser OFF - On Input Loss: Selecting this option disables the laser if the input signal is lost.
Fiber Optic Rx 2
This section displays the following information about the fiber optic input signal:
Rx Power
Rx Power State
These controls only apply to the SDI outputs on the BNC. The laser output is controlled by the Laser OFF and Laser OFF - On Input Loss controls.
These controls only apply to the fiber optic output signal. The SDI outputs on the BNC are controlled by the Mute and On Input Loss
- Mute controls. When the unit is forced to a particular standard, the laser co ntrols
are not grayed out, and the laser will still be active if an incorrect standard is applied unless Laser OFF - On Input Loss is selected.
Note:
Note:
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 13
Memory 1-16
Use the Memory function to save up to 16 setups to be recalled later. Default memory names can be changed to provide more meaning ful descriptions.
To save settings:
In the Save Memory column, select a memory location, and then click Save. The current settings are saved and the memory appears in the Recall Mem
-
ory column.
To change a memory name:
In the Save Memory Name field, type the new memory name, and then cli­click S. To return the memory to its default value, click the preset button (P).
Use the Recall Memory function to recall the settings saved in a memory location. Last Recalled Memory displays the most recently recalled memory. An asterisk next to the name displayed in the Last Recalled Memory field indicates that one or more controls has been changed since the memory was recalled.
To recall a memory:
In the Recall Memory column, select the memory to recall. The recalled set­tings will be applied and the memory name will appear in the Last Recalled Memory section.
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 14
Logging
Information about several parameters can be made available to a logging device that is connected to the RollCall network.
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 15
Each logging screen comprises three columns:
Log Enable: Select the check boxes that correspond to the parameters for which log information should be collected.
Log Field: Displays the name of the logging field.
Log Value: Displays the current log value.
RollCall Log Fields
Log Field Log Value
SN= <Serial number> OS_VERSION= <Operating system version> BUILD_NUMBER= <Software build number> HARDWARE_VERSION= <Hardware version number> UPTIME= <Time since last restart> LICENSED_OPTIONS= <Currently licensed options> INPUT_N_IDENT= <Input ident> INPUT_N_NAME= <Input name> INPUT_N_TYPE= <Input type> INPUT_N_STATE= OK, WARN, FAIL INPUT_N_SDIRATE= <Input bitrate> OUTPUT_1_LASER_BIAS_STATE= OK, WARN, FAIL
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 16
OUTPUT_1_LASER_BIAS= <Current Laser Bias in mA> OUTPUT_1_TX_POWER_STATE= OK, WARN, FAIL OUTPUT_1_TX_POWER= <Tx Power in dbm> OUTPUT_1_WAVELNGTH= <Wavelegth in nm> INPUT_N_ RX_POWER_STATE= OK, WARN, FAIL INPUT_N_RX_POWER= <Rx power measurement>
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 17
RollTrack
The RollTrack settings allow information to be sent, by means of the RollCall network, to other compatible units on the same network.
Use the settings on the RollTrack screen to:
Enable or disable the RollTrack functions.
Configure up to 16 RollTrack outputs.
Specify the conditions that trigger RollTrack data transmission.
Set RollTrack destinations.
Specify the RollTrack commands to be sent.
RollTrack Sources
The RollTrack Source specifies the source of the information that triggers the tr
ansmission of data.
RollTrack Addresses
The full RollTrack Address comprises four sets of numbers. For example, 00
00:10:01*99. The first set, 0000 in the example, is the network segment code number. The second set, 10 in the example, identifies the (enclosure/mainframe) unit. The third set, 01 in the example, identifies the slot number in the unit. The fourth set, 99 in the example, is the RollCall ID of the destination unit - a user-
configured number that uniquely identifies the destination unit in a multi-unit system. If it is set to anything other than 00 the unit will respond to RollTrack commands. If left at 00, an incorrectly fitted unit may respond inappropriately.
RollTrack Commands
Each RollTrack command co mprises two sets of n
umbers, for example, 33039:3.
The first set, 33039 in the example, is the RollTrack command number, which identifies the command.
The second set, 3 in the example, is the value that is sent with the command.
Using RollTracks
To enable or disable RollTrack functions:
To enable the RollTrack functions, clear the Disable All check box.
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 18
To disable RollTrack functions, select the Disable All check box. To configure a RollTrack action:
1. Select the Index number. This identifies the RollTrack action being config-
ured. Up to 16 RollTrack actions can be created.
2. From the Source list, select the source of the information that will trigger Roll-
Track transmission.
3. Enter the RollTrack Address and click S. To return the address to its default
value, click the preset button (P).
4. Enter the RollTrack Command and click S. To return the value to its default,
click the preset button (P).
Viewing RollTrack Information RollTrack Sending and RollTrack Status display information about the status
of RollTracks. RollTrack Sending displays the information when the unit is actively sending a
RollTrack command:
No: The command is not being sent.
Yes: The command is being sent. RollTrack Status displays the status of the currently selected RollTrack Index:
OK: RollTrack message sent and received OK.
Unknown: RollTrack message has been sent but has not yet completed.
Timeout: RollTrack message sent, but acknowledgement not received. This
could be because the destination unit is not at the specified location.
Bad: RollTrack message has not been sent correctly, acknowledged at the
destination unit. This could be because the destina tio n unit is not of the type specified.
Disabled: RollTrack sending is disabled.
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 19
Setup
The Setup screen displays basic information about the unit. Use the functions on the screen to restart the unit, return all settings to their factory defaults, and to change the names of the inputs.
On the Setup screen, the following information is displayed:
Product: This displays the name of the module.
Software Version: This displays the currently installed software version
number.
Serial No: This displays the unit’s serial number.
Build: This displays the factory build number . This number identifies all
parameters of the unit.
KOS: This displays the operating system version number.
PCB: This displays the PCB revision number.
Licensed Options: This displays the unit’s currently lice nsed options. To reboot the unit, simulating a power-up/power-down cycle, click Restart. To reset all of the unit’s settings to their factory defaults, click Factory Defaults.
To reset all ot the unit’s settings to their factory defaults, leaving user memories intact, click Default Settings.
Resetting the unit to its factory defaults will also clear all the saved memory settings
Note:
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 20
Input 1 Name and Input 2 Name
These are the input names displayed in logging. To change the name of Input 1 or Input 2, type the name in the text field and click S. To return the name to its factory default, click P.
Version 1 Issue 1 www.snellgroup.com IQOTR30
Page 21
Operation from an Active Control Panel
The module can be operated from an active control panel via the RollCall™ network.
All operational parameters and selections described in the previous section are made using a system of menus displayed in the two LCD windows – the Information window and the Control window.
Information Window
The information window contains four lines of text indicating the current state of the unit.
Control Window
The Control window displays all selection menus and sub-menus. The main or top level menu allows various sub-menu s to be selected by pressing
the button adjacent to the required text line. Note that where a menu item is followed by three dots (...) this indicates that a
further sub-menu may be selected. Whenever a menu item is selected the parameters of that selection will be
displayed in the Information window of the front panel. Where the selection is purely a mode selection and does not enable a sub-menu, the text will become reversed (white-on-black) indicating that the mode is active. If the mode is not available for selection the text will remain normal.
Version 1 Issue 1 www.snellgroup.com IQOTR30
22
Manual Revision Record
Date Version Issue Change Comments
12/05/09 1 1 First Issue.
Loading...