This manual contains information for the installation and operation of the KudosPro MC500
unit.
Software Version
Software version: 2.2.A.10
QT Library
KudosPro products use modified Qt Library under GNU LGPL:
http://doc.qt.io/qt-4.8/index.html
The Library, its modifications, and its use are covered by the terms of th is license.
Copyright and Disclaimer
Copyright protection claimed includes all forms and matters of copyrightable material and
information now allowed by statutory or judicial law or hereinafter granted, including without
limitation, material generated from the software programs which are displayed on the screen
such as icons, screen display looks etc.
Information in this manual and software are subject to change without notice and does not
represent a commitment on the part of SAM. The software described in this manual is
furnished under a license agreement and can not be reproduced or copied in any manner
without prior agreement with SAM or their authorized agents.
Reproduction or disassembly of embedded computer programs or algorithms pr ohibited.
No part of this publication can be transmitted or reproduced in any form or by any means,
electronic or mechanical, including photocopy, recording or any information storage and
retrieval system, without permission being granted, in writing, by the publishers or their
authorized agents.
SAM operates a policy of continuous improvement and development. SAM reserves the r ight
to make changes and improvements to any of the products described in this document
without prior notice.
Contact Det ails
Customer Support
For details of our Regional Customer Support Offices, please visit the SAM website and
navigate to Support/Contact Support.
www.s-a-m.com/support/contact-support/
Customers with a support contract should call their persona lized number, which can be found
in their contract, and be ready to provide their contract number and details.
Dieses Symbol weist den Benutzer auf wichtige Informationen
hin, die in der begleitenden Dokumentation enthalten sind.
Dieses Symbol zeigt an, dass gefährliche Spannung vorhanden ist.
Es befinden sich keine vom Benutzer zu wartenden Teile im Geräteinneren.
Dieses Gerät sollte nur von geschultem Personal gewartet werden
· Um das Risiko eines Elektroschocks zu reduzieren, setzen Sie das
Gerät weder Regen noch Feuchtigkeit aus.
· Stellen Sie immer sicher, dass das Gerät ordnungsgemäß geerdet
und verkabelt ist.
· Dieses Equipment muss an eine Netzsteckdose mit Schutzleiter
angeschlossen werden un d einen zuverlässig identifizierbaren Nullleiter haben.
· Die Netzsteckdose sollte nahe beim Gerät und einfach zugänglich sein.
Netzanschluss in anderen Ländern als der USA
Das Equipment wird im Normalfall mit einem Netzkabel mit Standard IEC
Anschlussbuchse und einem Standard IEC Anschlussstecker geliefert.
Sollten Sie den angeschweißten Stecker auswechseln müssen, entsorgen
Sie diesen bitte umgehend. Die farbliche Belegung des Netzkabels ist wie folgt:
GRÜN GELB E = Schutzleiter
BLAU N = Nulleiter
BRAUNL = P = Phase
Achtung: Wenn das Gerät zwei Anschlussbuchsen hat, stellen
Sie bitte sicher, dass beide Netzkabel mit der selben Phase in die
Netzsteckdose gesteckt werden.
Sicherheits-Warnhinweise
D
!
!
Die angeführten Service-/Reparatur-Anweisungen sind
ausschließlich von qualifiziertem Service-Personal
auszuführen. Um das Risiko eines lektroschoc ks zu
reduzieren, führen Sie ausschließlich die im
Benutzerhandbuch eschriebenen Anweisungen aus,
es sei denn, Sie haben die entsprechende Qualifikation.
Wenden Sie sich in allen Service-Fragen an qualifiziertes Personal.
!
ACHTUNG
Gefahr von Elektroschocks.
Abde ckungen nicht e ntfernen
Keine vom Benutz er zu wartend e Teile
Wenden Sie sich ausschließlich
an qualif iziertesPersonal
L=
PhaseN=NulleiterN=NulleiterL=Phase
E=
Schutzleiter
E=
Schutzleiter
Explicación de los Símbolos de Seguridad
Éste símbolo refiere al usuario información importante contenida
en la literatura incluida. Referirse al manual.
Éste símbolo indica que voltajes peligrosos están presentes en el interior.
No hay elementos accesibles al usuario dentro.
Esta unidad sólo debería ser tratada por personal cualificado.
Las instrucciones de servicio cuando sean dadas, son
sólo para uso de personal cualificado. Para reducir el
riesgo de choque eléctrico no llevar a cabo ninguna
operación de servicio aparte de las contenidas en las
instrucciones de operación, a menos que se esté
cualificado para realizarlas.
Referir todo el trabajo de servicio a personal cualificado.
· Para reducir el riesgo de choque eléctrico, no exponer este equipo
a la lluvia o humedad.
· Siempre asegurarse de que la unidad está propiamente conectada a
tierra y que las conexiones de alimentación están hechas correctamente.
· Este equipo debe ser alimentado desde un sistema de alimentación
con conexión a TIERRA y teniendo una conexión neutra fácilmente
identificable.
·
La toma de alimentación para la unidad debe ser cercana y fácilmente
accesible.
Conexión de alimentación en otros p aíses que no sean USA
El equipo es normalmente entregado con un cable de alimentación con un
enchufe hembra estándar IEC en un extremo y con una clavija estándar
IEC en el otro. Si se requiere eliminar la clavija para sustituirla por otra,
disponer dicha clavija de una forma segura.
El código de color a emplear es como sigue:
Advertencia Si la unidad tuviera dos tomas de alimentación, asegurarse
de que ambos cables de alimentación están conectados a la misma fase.
ESP
!
!
Advertencias de Seguridad
LNENL
E
Clavija
Aerea Macho
Enchufe
Aereo Hembra
VERDE/ AMARILLO conectado a E
(Conductor de protección a Tierra
-Earth en el original-)
AZUL conectado a N (Conductor Neutro -Neutral en el original-)
MARRÓN conectado a L (Conductor Fase -Live en el original-)
RIESGO DE CHOQUE ELECTRICO
NO QUITAR LAS PROTECCIONNES
ELEMENTOS NO ACCESIBLES AL
USUARIO.
SERVICIO SOLAMENTE A PERSONAL
CUALIFICADO
Questo simbolo indica l'informazione importante contenuta nei
manuali appartenenti all'apparecchiatura. Consultare il manuale.
Questo simbolo indica che all'interno dell'apparato sono presenti
tensioni pericolose. Non cercare di smontare l'unità.
Per qualsiasi tipo di intervento rivolgersi al personale qualificato.
Le istruzioni relative alla manutenzione sono ad uso
esclusivo del personale qualificato. E' proibito all'utente
eseguire qualsiasi operazione non esplicitamente
consentita nelle istruzioni. Per qualsiasi informazione
rivolgersi al personale qualificato.
· Per prevenire il pericolo di scosse elettriche è necessario non esporre
mai l'apparecchiatura alla pioggia o a qualsiasi tipo di umidità.
· Assicurarsi sempre, che l'unità sia propriamente messa a terra e che
le connessioni elettriche siano eseguite correttamente.
· Questo dispositivo deve essere collegato ad un impianto elettrico
dotato di un sistema di messa a terra efficace.
· La presa di corrente deve essere vicina all'apparecchio
e facilmente accessibile.
Connessione elettrica nei paesi diversi dagli Stati Un iti
L'apparecchiatura normalmente è spedita con cavo pressofuso con la presa
e spina standard IEC. Nel caso della rimozione della spina elettrica,
gettarla via immediatamente osservando tutte le precauzioni del caso.
La leggenda dei cavi è la seguente:
VERDE/GIALLO cavo connesso
ad "E" (terra)
BLU cavo connesso ad "N" (neutro)
MARRONE cavo connesso ad "L" ( fase)
Attenzione! Nel caso in cui l'apparecchio abbia due prese di corrente,
assicurarsi che i cavi non siano collegati a fasi diverse della rete elettrica.
I
!
!
Attenzione:
!
ATTENZIONE
LNENL
E
Presa volanteSpina volante
RISCHIO DI SHOCK ELETTRICO
NON CERCARE DI SMONTARE
L'UNITA PER QUALSIASI TIPO DI
INTERVENTO RIVOLGERSI AL
PERSONALE QUALIFICATO
Forklaring på sikkerhedssymboler
Dette symbol gør brugeren opmærksom på vigtig information
i den medfølgende manual.
Dette symbol indikerer farlig spænding inden i apparatet. Ingen bruger
servicerbare dele i apparatet på brugerniveau.
Dette apparat må kun serviceres af faglærte personer..
Serviceinstruktioner er kun til brug for faglærte
servicefolk. For at reducere risikoen for elektrisk
stød må bruger kun udføre anvisninger i
betjeningsmanualen.
Al service skal udføres af faglærte personer.
· For at reducere risikoen for elektrisk stød må apparatet ikke
udsættes for regn eller fugt.
· Sørg altid for at apparatet er korrekt tilsluttet og jordet.
· Dette apparat skal forbindes til en nettilslutning, der yder
BESKYTTENDE JORD og 0 forbindelse skal være tydeligt markeret.
· Stikkontakten, som forsyner apparatet, skal være tæt på apparatet
og let tilgængelig
.
Nettilslutning i andre lande end USA
Udstyret leveres normalt med et strømkabel med et standard IEC støbt løst
hunstik i den ene ende og et standard IEC støbt hanstik i den anden ende.
Hvis et af de støbte stik på strømkablet er defekt, skal det straks kasseres på
forsvarlig vis. Farvekoden for lederen er som følger:
GRØN/GUL leder forbundet til J (Jord)
BLÅ leder forbundet til 0
BRUN leder forbundet til F(Fase)
Forsigtig Hvis enheden har to lysnetindgange, skal der sørges for at
begge ledninger tilsluttes lystnetudgange fra den samme fase.
DK
!
!
!
Sikkerhedsadvarsler
!
FORSIGTIG
RISIKO FOR ELEKTRISK STØD
DÆKPLADER MÅ IKKEFJERNES
INGEN BRUGER SERVICERBARE
DELE SERVIC E MÅ KUN UDFØ RES
AF FAGLÆRTE PERSONER
F0J0F
J
Han-stikHun-stik
Förklaring av Säkerhetssymboler
Denna symbol hänvisar användaren till viktig information som
återfinns i litteraturen som medföljer. Se manualen.
Denna symbol indikerar att livsfarlig spänning finns på insidan.
Det finns inga servicevänliga delar inne i apparaten.
Denna apparat få endast repareras av utbildad personal.
Serviceinstruktioner som anges avser endast kvalificerad
och utbildad servicepersonal. För att minska risken för
elektrisk stöt, utför ingen annan service än den som
återfinns i medföljande d riftins truktion erna, om d u ej är
behörig. Överlåt all service till kvalificerad personal.
· För att reducera risken för elektrisk stöt, utsätt inte apparaten för
regn eller fukt.
· Se alltid till att apparaten är ordentligt jordad samt att strömtillförseln
är korrekt utförd.
· Denna apparat måste bli försörjd från ett strömsystem som är försedd
med jordadanslutning samt ha en neutral anslutning som lätt identifierbar.
· Vägguttaget som strömförsörjer apparaten bör finnas i närheten samt
vara lätttillgänglig.
Strömkontakter i länder utanför USA
Apparaten utrustas normalt med en strömkabel med standard IEC gjuten
honkontakt på ena änden samt en standard IEC gjuten hankontakt på den
andra änden. Om man måste avlägsna den gjutna hankontkaten, avyttra
denna kontakt omedelbart på ett säkert sätt. Färgkoden för ledningen är följande:
GRÖN/GUL ledning ansluten till E
(Skyddsjordad ledare)
BLÅ ledning ansluten till N (Neutral ledare)
BRUN ledning ansluten till L (Fas ledare)
Varning! Om enheten har två huvudsakliga elförsörjningar, säkerställ att
båda strömkablarna som är inkopplade i enheten arbetar från samma fas.
S
!
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVERS
NO USER SERVICEABLE PARTS
REFER SERVICING TO QUALIFIED
PERSONNEL ONLY
!
!
Säkerhetsvarningar
LNENL
E
Stickkontakt-HaneStickkontakt-Hona
Turvamerkkien selitys
Tämä merkki tarkoittaa, että laitteen mukana toimitettu kirjallinen
materiaali sisältää tärkeitä tietoja. Lue käyttöohje.
Tämä merkki ilmoittaa, että laitteen sisällä on vaarallisen voimakas jännite.
Sisäpuolella ei ole mitään osia, joita käyttäjä voisi itse huoltaa.
Huollon saa suorittaa vain alan ammattilainen.
Huolto-ohjeet on tarkoitettu ainoastaan alan
ammattilaisille. Älä suorita laitteelle muita
toimenpiteitä, kuin mitä käyttöohjeissa on
neuvottu, ellet ole asiantuntija. Voit saada sähköiskun.
Jätä kaikki huoltotoimet ammattilaiselle.
· Sähköiskujen välttämiseksi suojaa laite sateelta ja kosteudelta.
· Varmistu, että laite on asianmukaisesti maadoitettu ja että
sähkökytkennät on tehty oikein.
· Laitteelle tehoa syöttävässä järjestelmässä tulee olla
SUOJAMAALIITÄNTÄ ja nollaliitännän on oltava luotettavasti
tunnistettavissa.
· Sähköpistorasian tulee olla laitteen lähellä ja helposti tavoitettavissa.
Sähkökytkentä
Laitteen vakiovarusteena on sähköjohto, jonka toisessa päässä on muottiin
valettu, IEC-standardin mukainen liitäntärasia ja toisessa päässä muottiin
valettu, IEC-standardin mukainen pistoliitin. Jos pistoliitin tarvitsee poistaa,
se tulee hävittää heti turvallisella tavalla. Johtimet kytketään seuraavasti:
KELTA-VIHREÄ suojamaajohdin E-napaan
SININEN nollajohdin N-napaan
RUSKEA vaihejohdin L-napaan
Huom! Jos laitteessa on kaksi verkkojännitteen tuloliitäntää, niiden johdot
on liitettävä verkkopistorasioihin, joissa on sama vaiheistus.
O símbolo triangular adverte para a necessidade de consultar o
manual antes de utilizar o equipamento ou efectuar qualquer ajuste.
Este símbolo indica a presença de voltagens perigosas no interior
do equipamento. As peças ou partes existentes no interior do equipamento
não necessitam de intervenção, manutenção ou manuseamento por parte
do utilizador. Reparações ou outras intervenções devem ser efectuadas
apenas por técnicos devidamente habilitados.
As instruções de manutenção fornecidas são para
utilização de técnicos qualificados. Para reduzir o
risco de choque eléctrico, não devem ser realizadas
intervenções no equipamento não especificadas no
manual de instalações a menos que seja efectuadas
por técnicos habilitados.
· Para reduzir o risco de choque eléctrico, não expor este equipamento
à chuva ou humidade.
· Assegurar que a unidade está sempre devidamente ligada à terra e
que as ligações à alimentação estão correctas.
· O sistema de alimentação do equipamento deve, por razões de
segurança, possuir ligação a terra de protecção e ligação ao
NEUTRO devidamente identificada.
· A tomada de energia à qual a unidade está ligada deve situar-se na
sua proximidade e facilmente acessível.
Ligação da alimentação noutros países que não os EUA
O equipamento é, normalmente, enviado com cabo de alimentação com ficha
IEC fêmea standard num extremo e uma ficha IEC macho standard no extremo
oposto. Se for necessário substituir ou alterar alguma destas fichas, deverá
remove-la e elimina-la imediatamente de maneira segura.
O código de cor para os condutores é o seguinte:
Condutor VERDE/AMARELO ligado a E (Terra)
Condutor AZUL ligado a N (Neutro)
Condutor CASTANHO ligado a L (Vivo).
Atenção: Se a unidade tem duas fontes de alimentação assegurar que os
dois cabos de alimentação estão ligados a tomadas pertencentes à mesma fa se.
This equipment has two 3-pin IEC power sockets, on e for the main power su pply unit and one
for the redundant power supply unit.
The power supply is auto switching for input voltages in the ranges of 100 V to 240 V nominal.
No voltage adjustment procedure is required.
•This equipment has more than one power supply. To reduce the risk of electric
shock, plug each power supply into separate branch circuits employing separate
service grounds.
•Before performing any servicing or maintenance, disconnect and isolate the unit
from the mains input and from any product outputs.
•Do not operate this unit without an earth connection.
Power Cord Supplied
The equipment is shipped with a power cord with a standard molded IEC female plug on one
end and a standard mains plug on the other. If you are required to remove the molded mains
supply plug, dispose of the plug immediately in a safe manner.
The color code for the cord is as follows:
•GREEN/YELLOW lead connected to E (Protective Earth Conductor)
•BROWN lead connected to L (Live Conductor)
•BLUE lead connected to N (Neutral Conductor)
Laser Safety
This product operates with Class 1 laser products.
Caution: Use of controls or adjustments or performance of procedures other than those
specified herein may result in hazardous radiation exposure.
Ventilation
Although the unit is constructed to meet normal environmental requirements, ensure that
there is a free flow of air at the front, rear, and sides of the unit to dissipate the heat produced
during operation. Installations should be designed to allow for this.
Do not obstruct the ventilation holes on the right-side of the un it. Damage to the equipment
may result.
This equipment conforms to the following standards:
EN60950-1 2006
Safety of Information Technology Equipment
Including Electrical Business Equipment.
UL1419 (3rd Edition) - UL File E193966
Standard for Safety – Professional Video and Audio equipment.
EMC Standards
This equipment conforms to the following standards:
EN 55103-1: 1996 (Environment E4)
Electromagnetic Compatibility, Product family standard for audio, video, audio-visual and
entertainment lighting control apparatus for professional use. Part 1. Emission.
EN 55103-2: 1996 (Environment E2)
Electromagnetic Compatibility, Product family standard for audio, video, audio-visual and
entertainment lighting control apparatus for professional use. Part 2. Immunity.
FCC/ FR 47:Part 15, Class A
Federal Communications Commission Rules Part 15, Subpart B, Class A.
EMC Environment
The product(s) described in this manual conform to the EMC requirements for, and are
intended for use in, the controlled EMC environment (for example, purpose-b uilt broadcasting
or recording studios), and the rural outdoor envi ronment (far away from railways, transm itters,
overhead power lines, etc.) E4.
EMC Performance of Cables and Connectors
SAM products are designed to meet or exceed the requirement s of the app ropriate Eur opean
EMC standards. In order to achieve this performance in real installations it is essential to use
cables and connectors with good EMC characteristics.
All signal connections (including remote control connections) shall be made with screened
cables terminated in connectors having a metal shell. The cable screen sh all have a
large-area contact with the metal shell.
Coaxial Cables
Coaxial cables connections (particularly serial digital video connections) shall be made with
high-quality double-screened coaxial cables such as Belden 1694 or BBC type PSF1/2M.
D-type Connectors
D-type connectors shall have metal shells making good RF contact with the cable screen.
Connectors having “dimples” which improve the contact between the plug and socket shells
are recommended.
The MC500 offers one channel of frame rate or format conversion with a choice of four SDI
inputs and four SDI outputs. If the CVBS I/O option is fitted, CVBS A1 and A2 are inputs to the
MC500, and CVBS B1 and B2 are outputs.
1.5.1.16143100 – MC500 Base Model
1.5.1.26143110 – MC500 with CVBS Option
If the optional SFP connectors are fitted as receivers, they will not be available as
transmitters. Likewise, if fitted as transmitters, they will not be available as receivers.
Up, down, and cross conversion
ConversionLinear/motion compensated
Conversion processingStill process: Detects still images and applies an aperture with full (progressive)
vertical frequency response
Enhanced still: Adds field motion detection to still process. Prevents artifacts on
moving repetitive patterns
Aspect ratio conversion
AFD (SMPTE 2016), VI (RP186), WSS (L23)
(manual or auto)
Remote controlRemote control RollCall network (IP)
Web browserWeb applet (Java required)
Power
Input voltage range
100 to 240 VAC, 50/60 Hz 1.2 A (max), via three-pin IEC power socket
(primary & secondary)
Mechanical
Temperature range0 to 45°C operating
CoolingInternal fan, side venting
Weight3.2 kg approx
Case type1U, rack mounting
Dimensions44 mm x 430 mm x 400 mm (h, w, d)
Refer to “Safety Information” on page 3 before installing and connecting power to the unit.
3.1Unpacking the Unit
The unit is packed in a single cardboard box. Unpack the box carefully and check for any
shortages or shipping damage. Report any shortages or shipping damage to SAM
immediately.
The box contains the following items:
•KudosPro MC500 unit
•Two power cables
•Operator’s Manual CD
Retain any product packaging as it may be required if returning the unit to SAM.
3.2Rack Mounting the Unit
Ensure that sufficient space is available for the unit.
When installing the unit, place on a suitably specified and installed rack shelf and secure the
unit using the front rack ears.
3.3Ventilation
Ensure that there is a free flow of air at the front, rear, and sides of the unit to dissipate the
heat produced during operation. Installations should be designed to allow for this.
Do not obstruct the ventilation holes on the right-side of the un it. Damage to the equipment
may result.
The rear panel accommodates a CVBS option with AES unbalanced aud io and composite
video connections.
4.1.1CVBS Option
4.1.2Non-CVBS Option
Connections labeled I/O can be used as inputs or outputs.
4.2Input and Output Connections
LabelDescriptionConnector
SDI In 1, 2, 3, 4SDI inputs4 x BNC
SDI Out A1, A2, B1, B2SDI outputs4 x BNC
Analog Audio In (option)Analog audio inputs1 x 25-way D-type
Analog Audio Out (option)Analog audio outputs1 x 25-way D-type
AES Audio In (option)AES audio inputs4 x unbalanced BNC
AES Audio Out (option)AES audio outputs4 x unbalanced BNC
AES Audio I/O (option)Balanced AES audio
input/output
ReferenceAnalog reference input with
passive loop-through
CVBS In A1, A2 (option)Composite input2 x BNC
CVBS Out B1, B2 (option)Composite output2 x BNC
Option I/O ASignal input/output1 x dual SFP compatible
1 x 25-way D-type
2 x BNC
Option I/O BSignal input/output1 x dual SFP compatible
MonitorHDMI output1 x HDMI
Power APSU input (primary)1 x 3-pin IEC
Power BPSU input (secondary)1 x 3-pin IEC
If one of the reference connectors is not in use it must be fitted with a 75 Ohm BNC
terminating plug. If not terminated co rr ec tly, genlock performance may be degraded.
The Option sockets allow for up to two dual Small Form Factor Pluggable (SFP)
transceiver modules. The SFP modules can be used to add optional fiber connectivity, or
optional I/O using HD BNC connectors.
CHASSIS1CHASSIS1CHASSIS1
GND114GND114GND114
Ch 8 in +2Ch 8 out +2Ch 4 out +2
Ch 8 in -15Ch 8 out -15Ch 4 out -15
Ch 7 in +3Ch 7 out +3Ch 2 out +3
Ch 7 in -16Ch 7 out -16Ch 3 out -16
GND24GND24GND24
GND317GND317GND317
Ch 6 in +5Ch 6 out +5Ch 2 out +5
Ch 6 in -18Ch 6 out -18Ch 2 out -18
Ch 5 in +6Ch 5 out +6Ch 1 out +6
Ch 5 in -19Ch 5 out -19Ch 1 out -19
GND47GND47GND47
GND520GND520GND520
Ch 4 in +8Ch 4 out +8Ch 4 in +8
Ch 4 in -21Ch 4 out -21Ch 4 in -21
Ch 3 in +9Ch 3 out +9Ch 3 in +9
Ch 3 in -22Ch 3 out -22Ch 3 in -22
GND610GND610GND610
GND723GND723GND723
Ch 2 in +11Ch 2 out +11Ch 2 in +11
Ch 2 in -24Ch 2 out -24Ch 2 in -24
Ch 1 in +12Ch 1 out +12Ch 1 in +12
Ch 1 in -25Ch 1 out -25Ch 1 in -25
GND813GND813GND813
If no fiber option is fitted on the rear panel, do not remove th e safety covers from the op tion
slots.
Two dual fibre ports are available as an option. Each port can be configured as one of the
following:
•Dual receivers
•Dual transmitters
•Transceiver (Tx + Rx)
•Not fitted
If all the optional SFP connectors A1, A2, B1, and B2 are fitted as receivers, they will not
be available as transmitters. Likewise, if they are fitted as transmitters, they will not be
available as receivers.
4.3Control Connections
LabelDescriptionConnector
Network10/100 BaseT Ethernet
GPIGeneral Purpose Inputs. 1 x 9-way D-type
4.3.1GPI Pin Numbers
The GPIs are accessed via a 9-way D-type male connector. In the following table, GPI refers
to inputs.
The front panel provides a user-friendly interface for complete control of the unit. A dual
display shows the menu options and output signal, and various buttons provide easy access
to the unit’s features.
The display screens shown in this section are for reference an d guidance only, and may be
slightly different to those you see on your unit.
5.1Front Panel Layout
5.2Front Panel Dual Display
The dual display shows different variations depending on what is selected. Some examples
are as follows:
•On the Home screen, the display shows status information for the processing
channel:
•On a menu list, the display shows the menu options and current output signal:
•On a menu list with a menu option selected, for exam ple , Pro c Amp > Cont ra st, the
display shows the menu list and menu option:
•The left-side of the display shows the menu list.
•The right-side of the display shows either the output video or
the menu options.
Scrolls through the menu lists, selects menu options, and adjusts
values.
Control knob
•Rotate clockwise or anti-clockwise to scroll down or up
through a menu list or to adjust values on a menu option.
•Press to select a menu option or confirm changes.
Moves through the menu lists, selects menu options, and adjusts
values.
5-way navigation
buttons: Up, Down,
Left/Back, Right, and
Select
•Up and Down: Press to move up or down through a menu list.
•Left/Back and Right: Press to move forward or back through
a menu list or to adjust values on a menu option.
•Select: Press to select a menu option or confirm changes.
Home button (HOME)•Press to return to the default Home screen at any time.
The Shortcut buttons provide direct access to the corresponding
menus. The Alphanumeric buttons allow manual number and text
entry in a text box, and manual number entry for slider values.
Shortcut/
Alphanumeric buttons
Standby button
(STANDBY)
Control lock button
(CONTROL LOCK)
PSU status LEDs
(PSU A, PSU B)
Control status LEDs
(LOCAL, REMOTE)
•Buttons illuminated: You can press the Shortcut buttons to
access the corresponding menu.
•Buttons not illuminated: Indicates that a manual adjustment
or manual selection is available – for example, a slider value,
check box, or text box.
Turns the unit on or puts the unit into standby mode.
•Press once to turn the unit on, or press and hold to put the
unit into standby mode. When the unit is in standby mode,
the corresponding PSU LED is illuminated red.
•Press to lock or unlock the front panel controls.
Shows the status of the dual PSUs.
•PSU A illuminated green: PSU A (primary) in use.
•PSU B illuminated green: PSU B (secondary) in use.
•PSU illuminated red: Unit in standby (power saving) mode.
Shows the monitoring status.
•LOCAL illuminated: Local control present.
•REMOTE illuminated: RollCall Control Panel in use.
The front panel provides easy access to the unit’s menu structure. From the Home screen, a
main menu list provides access to various sub-menus. Each sub-menu option from the main
menu list has various screens and controls associated with it.
For detailed information of the options and controls available from each menu, see “Channel
Operation Menus” on page 44.
You can use either the Control knob or the 5-way navigation buttons to move through
menus and select menu options. For consistency, we will use the Control knob in the
following examples.
6.1Turning the Unit On
•Press the STANDBY button.
The PSU LED turns green and the SAM splash screen appears on the dual display.
After a few minutes, the Home screen appears.
6.2Home Screen
The Home screen shows the following information:
•Unit name
•IP address
•Input and output status
•Audio Status
You can return to the Home screen at any time by pressin g th e HOM E bu tto n .
The unit automatically defaults to the Home screen after a few minutes if no controls are
used.
6.3Accessing the Main Menu List
1.From the Home screen, press the Control knob.
The channel status is displayed.
2.Press the Control knob again to access the main menu list.
The main menu list is displayed.
•Rotate the Control knob clockwise to scroll down through a menu list, or
anti-clockwise to scroll up through a menu list.
6.5Selecting Menu Options
•When on a required menu, press the Control knob to select it.
6.6Adjusting Values
When you select a menu option that requires adjustment, such as Noise Rejection, you can
adjust the values by using the Control/Select knob or the alphanumeric buttons. The
Control/Select knob provides control for fine-tuning values in small increments. The
alphanumeric buttons are useful for quick entry of a specific value.
6.6.1Adjusting Values with the Control Knob
1.Navigate to the menu option slider that requires adjustment.
2.Rotate the Control knob clockwise to increase the value or anti-clockwise to decrease
the value.
3.Press the Control knob to set the value, then press it again on Done ( ) to confirm.
The menu option closes and returns to the menu list.
To reset any menu back to its pr eset value, from the menu op tion selected, pre ss and hold
the Control knob for a few seconds.
6.6.2 Adjusting Values with the Alphanumeric Buttons
1.Navigate to the menu option that requires adjustment.
2.Enter the required value using the Alphanumeric buttons.
3.Press the Control knob to set the value, then press it again on Done ( ) to confirm.
The menu option closes and returns to the menu list.
For more information about alphanumeric functions, see “Enterin g Alpha numeric Characters”
on page 29.
Occasionally you may need to enter alphanumeric characters manually. This could be when
setting an IP address or entering a memory name, for example.
To enter values manually:
1.Navigate to a menu option that requires manual text input, for example, Memory
Name.
2.On the text box, press the Control knob.
The text entry cursor appears.
3.Press the relevant Alphanumeric buttons, 1 to 8, repeatedly until the desired
character appears. If the next character you want is on the same button as the
present one, wait until the cursor blinks once before pressing the button again.
•To enter a space between char acters, press button 0.
•To enter a special character, such as the @ symbol, press button 9.
•To delete a character, press the Back button.
4.When you have finished entering the name, press the Control knob to set it, an d press
it again on Done to confirm.
6.8Resetting Menu Options to Preset Values
If you need to reset a menu option, such as a slider value, to its preset default value, do the
following:
•From the menu option selected, press and hold the Control knob for a few seconds
until the values are reset.
6.9Using Shortcuts
The Shortcut buttons provide access to the more commonly used menus.
For example, to access the Video menu:
•On the front panel, press the VIDEO Shortcut button.
The Video menu list is displayed.
Shortcuts are only available when the buttons are illuminated.
This section details all of the screens, menu lists, options, and controls available for setting up
the unit from the front panel.
For information about using the various front panel controls, see “Front Panel Features” on
page 25. For information about navigating menus, see “Operation Using the Front Panel” on
page 27.
The screens shown in this section are for guidance and reference only, and may be slightly
different to those on your unit.
7.1System
The System home screen shows status of the unit in use . You ca n access the System scr een
at any time and from any menu by pressing the SYSTEM Shortcut button.
7.2CVBS
The CVBS menu enables you to set up and view options for a video input source and the
video output signal. CVBS provides options for the two composite video input/output slots (if
the CVBS option is fitted).
Composite encoding and decoding options will have been chosen at the time of product
purchase. Y/C decoding is also available.
7.2.1 CVBS Decoder
Each slot has two composite video connections.
•Source: Use to select a video input source. If using a composite source, only one of
the two CVBS connectors are used.
•Input 1: Connection A1 contains the input composite signal.
•Input 2: Connection A2 contains the input composite signal.
•Y/C: When using Y/C signals both composite connectors are used, so this option
must be selected.
•ACC: The Automatic Chroma Control (ACC) examines the input burst amplitude and
adjusts chrominance gain to compensate for chroma level attenuation.
Note: Use this control when chroma levels are low compared to luminance. This may
occur when using YC installations or composite from RF links.
•CTI: The Chroma Transient Improver (CTI) examines the input video data. CTI
detects transitions of chroma and enhances chroma edges in order to artificially
restore lost color bandwidth.
Note: Use this control when the input video has chroma bandwidth limitations.
•Pedestal: When turned on, allows the composite source (NTSC only) to be treated as
if a pedestal is present.
•NTSC Hue: Adjusts the NTSC hue to correct tonal color changes.
The unit automatically detects the input standard.
7.2.2 CVBS Encoder
Each slot has two composite video connections.
•Source: Use to route the processing channel to the chosen CVBS encoder.
•Format: Specifies the CVBS output standard. The options are:
•PAL/NTSC
•PAL-M/PAL-N
•PAL/NTSC-J
7.2.3 Routing the Processing Channel
To route the processing channel output to a CVBS output:
1.From the System menu, select CVBS > CVBS Encoder B > Format.
2.Choose the format of the composite output, then select Done.
For example, to create a PAL composite output on slot B1 where the converted output has
been downconverted using the processing channel:
•Select CVBS > CVBS Encoder B > Format, PAL/NTSC, then select Done.
If an illegal signal such as HD video is routed to a CVBS encoder, there will be no output
signal from this connector.
The Genlock controls lock the output video clock to the genlock source (input or reference)
regardless of the video standard. If the genlock source and the video output are the same
frame rate, for example, 50 Hz or 59.94 Hz, Genlock locks the output to the vertical phase of
the genlock source, giving consistent and repeatable delay.
Lock to input wherever possible. Only lock to an external reference if necessary.
When attempting to pass non-PCM audio, ensure that Genlock is enabled. If using an
external reference, it must be clock-locked to the input video.
If Genlock is set to Free Run, non-PCM audio will always be corrupt.
7.5.1 Source Ch 1
The Source Ch 1 menu enables you to select options for a genlock source.
•Ref Lock: Locks the output video to the incoming reference.
•Ch 1 Input: Locks the output video to the channel 1 input.
•Free Run: Locks the output video to an internal reference clock.
7.5.2 Reference Status
Reference St atus shows the standard of the reference signal. If reference has been assigned
using the controls but an input signal is no t detected on th e assigned reference input, Curr ent
reference standard shows “Invalid input”.
7.5.3 Timing
7.5.3.1 Ch 1
The Timing controls enable you to specify the horizontal and vertical genlock timing.
•Vertical Timing: Adjusts the vertical timing of the output signal with respect to the
reference signal. The adjustment range is one output line in one-line steps. The
preset value is 0.
•Horizontal Timing: Adjusts the horizontal timing of the output signal with respect to
the reference signal. The adjustment range is one output frame in one-pixel steps.
The preset value is 0.
•Status: Shows the status of the currently assigned referen ce. For example, if genlo ck
is assigned to input 1, status shows “Ch 1 Input” followed by the current status of the
input. If there is no signal on the assigned reference, status shows “REF Loss”.
The Dolby menu enables you to set up the how the u nit handles Dolby audio. T he MC500 unit
supports Dolby D and E decoding as well as Dolby E transcoding when frame rate converting.
Dolby E encoding from a PCM input is not supported.
The Dolby encoder acts in tandem with the Dolby decoder: Dolby transcoding from one
frame rate to another is enabled. It is not possible to author Dolby audio from a PCM input.
Dolby transcoding means that a change to the Dolby frame rate is enabled, but a change to
the Dolby program format is not possible. For example, if the incoming video is at 50 Hz with
5.1+2 Dolby audio, when the MC500 is set to standards convert the video to 59 Hz, the Dolby
transcode function enables you to create 5.1+2 Dolby audio at 59 Hz. The output Dolby fr ame
rate follows the output video frame rate chosen for the processing channel.
Routing of the Dolby E decoded and transcoded outputs to embedded SDI is limited by
hardware. If the Dolby option is fitted, the output of this decoder/transcoder is only
available as embedded audio on SDI outputs A1 and A2, an d can be r outed to any AES o r
analog audio encoder (if fitted). See “Block Diagrams” on page 15.
For more information about the Dolby decoder and transcoder, see the KudosPro Dolby
Each Dolby slot houses a Dolby encoder and transcoder.
If the Dolby option is not fitted, the Dolby menus are grayed out.
•Decoder Source: Enables you to route the chosen incoming audio source (SDI or
AES) to the Dolby decoder. See “Block Diagrams” on page 15.
•Input Status: Shows the detected audio. If this shows as “PCM”, the incoming audio
is not Dolby and Dolby processing is not active.
•Decoder Format: Provides Dolby E/D source information. For example, in the case
of Dolby E, this could be 5.1+2, 7.1, 8x1 etc.
•Decoder Rate: Shows the frame rate of the incoming Dolby audio (50 Hz or 59 Hz).
•Decoder Version: Shows the version number of the Dolby decoder. The Dolby E
decoder and encoder both have their own software ver sion installed which is
independent from the rest of the unit. Dolby updates this software continually.
•Metadata Source: Enables you to choose whether to use the incoming Dolby
metadata when transcoding. Select the Decoder radio button to enable the metadata
or the None radio button to discard it.
•Dolby Delay Compensation: Enables you to select delay compensation to maintain
correct alignment.
•Encoder Version: Shows the version number of the Dolby encoder. The Dolby E
decoder and encoder both have their own software ver sion installed which is
independent from the rest of the unit. Dolby updates this software continually.
•SMPTE 2020 Output: Selects the output line on which to insert a SMPTE 2020
VANC packet if the output is enabled. The range is from line 8 to line 20 in one-line
steps.
It is possible to set a forced association in the SMPTE 2020 metadata which sets the
Secondary Data ID (SDID) values used to identify the VANC packets to 45/02 (pair 1).
To use this control, enable “SDID Pair 1 Forced Assoc” from the Dolby menu under
the sub-menu SMPTE 2020 Output. When enabled, the outgoing 2020 data will be
labelled 45/02 (pair 1).
•Packet Type: Selects a method of data mapping for output SMPTE 2020 VANC
packets.
•A: SMPTE 2020-2-2008.
•B: SMTE 2020-3-2008.
•Dolby Metadata Ou tpu t Line Status: Shows the actual output line number on which
the SMPTE 2020 VANC packet is embedded, as set on the SMPTE 2020 Output
slider. If no line number is selected, “OFF” is displayed.
Note: If the line selected is already in use (by VITC, for example), the VANC
embedding hierarchy will embed the SMPTE 2020 packet on the nearest available
line.
The Network menu provides access to the unit’s network details and setup.
7.7.1 Ethernet
The Ethernet controls enable you to view and set up all information relating to the unit’s
network connections.
•Current IP address: Shows the current IP address.
•Current IP Netmask: Shows the current netmask.
•Current IP Gateway: Shows the current gateway.
•MAC Address: Shows the unit's MAC address
•IP Configuration: Enables you to specify whether the unit is to use a DHCP or a
static IP address. See “Setting a Static IP Address” on page 38 and “Setting a DHCP
IP Address” on page 38.
•IP Address: Enables you to enter an IP address.
•IP Gateway: Enables you to enter a gateway address.
•IP Netmask: Enables you to enter a netmask address.
•Apply IP Changes: Applies any changes you make in the Ethernet menu.
•IP Configuration Status: Shows the current IP configuration.
•Interface Status: Shows the status of the Ethernet connection, for example, “100M
full duplex”.
Note: If Interface Status shows “down”, it means that no Ethernet connection is
detected.
To set a static IP address, you will need to enter all the following information: IP address,
IP gateway (even if you are not using an IP gateway), and IP netmask.
In the following example, we are setting a static IP address of 192.168.1.42.
To set a static IP address:
1.From the System menu, select Network > Ethernet > IP Configuration.
2.Select Fixed Address, then select Done.
3.Select IP Address.
4.Enter 192.168.1.42 using the Alphanumeric buttons, then select Done.
5.Select IP Gateway.
6.Enter 192.168.1.12 using the Alphanumeric buttons, then select Done.
7.Select IP Netmask.
8.Enter 255.255.255.0 using the Alphanumeric buttons, then select Done.
9.When all addresses are set, you must apply the changes. To do this:
•Select the Apply IP Changes button, then select Done.
The system updates and saves the changes made in the Ethernet menu.
You must disconnect the unit from your Local Area Network before setting a static IP
address to avoid IP conflicts on the network.
If the combination of IP address, IP gateway, and IP netmask is invalid, the system will not
update the IP address.
7.7.1.2 Setting a DHCP IP Address
•From the System menu, select Network > Ethernet > IP Configuration > DHCP, then
select Done.
If you make any changes to the settings in the Ethernet menu, you must select the Appl y IP
Changes button to confirm the changes.
7.7.2 RollCall
The RollCall menu enables you to view and set up the unit’s RollCall attributes.
The Front Panel menu enables you to customize some front panel features for ease of use.
7.8.1 Lock Front Panel
Lock Front Panel locks all of the front panel controls to prevent accidental changes to the
unit’s settings.
7.8.2 Brightness
The Brightness control enables you to adjust the brightness of the front panel display . Using a
lower setting can help save power and increase screen life.
The Memories menu enables you to save up to eight system-level memory setups and recall
them when required.
You can change the default memory names to more relevant ones if required.
Memories set at a system level store all system settings except for the following:
•Network > DHCP
•Network > IP Configuration
•Network > IP Gateway
•Network > IP Netmask
•RollCall > Unit Name
Settings stored in the system memories include:
•CVBS encoder or decoder settings (if fitted)
•Dolby option settings (if fitted)
•Genlock selection and adjustment
•AES and analog audio routing
•CVBS calibration
System memories do not store any processing channel data.
7.9.1 Memory Select
Memory Select lists the eight available memories.
7.9.2 Save Memory
Use the Save Memory button to save a new memory.
7.9.3 Recall Memory
The Recall Memory list recalls the settings saved in a memory location.
Reset to Defaults recalls the unit’s default memor y settings at both system and channel level.
All controls are reset to their preset values except for the following:
•Network > DHCP
•Network > IP Configuration
•Network > IP Gateway
•Network > IP Netmask
•RollCall > Unit Name.
Reset to Defaults does not affect user memories.
7.9.5 Factory Reset
Factory Reset clears all user memories. Make a note of any important settings before
performing a factory rest.
Factory Reset recalls the unit’s default memory settings at both system and channel le vel. All
controls and user memories are reset to their preset values.
The default settings for IP Configuration is to set the unit to DHCP. Any saved settings for IP
Address, IP Netmask, and IP Gateway are also lost when performing a factory reset. The unit
returns all three to their default settings, which are as follows:
•IP Configuration: DHCP
•IP Address: 192.168.151.1
•IP Netmask: 255.255.255.0
•IP Gateway: 192.168.151.200
7.9.5.1 Performing a Factory Reset
1.On the front panel, press the SYSTEM Shortcut button.
2.Select Memories > Factory Reset, then select Done.
3.Do one of the following to apply the changes:
•Select Network > Apply IP Changes, then select Done.
•Reboot the system.
If performing a factory reset via a remote link, when you select Apply IP Changes, the
remote link will be lost.
2.Select the text box.
The text entry cursor appears.
3.Press an Alphanumeric button, 1 to 8, rep eatedly until the de sired ch aracte r appear s.
If the next character you want is on the same button as the present one, wait u ntil the
cursor blinks once before pressing the button again.
•To enter a space between characters, press button 0.
•To enter a special character, such as the @ symbol, press button 9.
This section details all of the menu lists, options, and controls available for performing signal
processing, frame rate, and format conversions from the front panel.
For information about using the front panel controls, see “Front Panel Features” on page 25.
For information about navigating menus, see “Operation Using the Front Panel” on page 27.
The screens shown in this section are for guidance and reference only, and may be slightly
different to those on your unit.
8.1Home
The Home screen shows status of the unit in use. You can access the Home screen at any
time and from any menu by pressing the HOME button.
8.2Input
The Input menu enables you to specify a video input source.
8.2.1 Input Select
Input Select lists the available input sources.
You can choose from the following, where applicable:
•SDI 1–4
•CVBS A
•SFP A1, A2, B1, B2
The unit automatically detects the input standard.
8.2.2 Status
The Status list shows the current input status for any input. This is the same as the Input
Select list.
The Output menu enables you to apply various settings and adjustments to the video output
signal.
8.3.1 Output Standard
The Output Standard list enables you to specify the output standard of a conversion, for
example, 625 50i.
8.3.2 Current Output Standard
Current Output Standard shows the output standard currently in use, for example, 625 50i.
8.3.3 Blanking
•Embedded Audio:
•Enable (Default): enables embedded audio
•Blank: removes embedded audio
•SD Half Line:
•Pass (Default): enables source half lines
•Blank: will blank the source half lines. This can be useful for certain ARC
settings, for example, SD16:9AN to SD4:3 Fit to Width
8.3.4 Test Patterns
The Test Patterns list enables you to choose the type of pattern displayed on the output
picture. You can choose from Off, Black, Ramp, and Bars.
8.3.5 Scrolling Caption Generator
The Scrolling Caption Generator overlays a black text box with a user-defined caption onto
the output video. This is generally used as a setup or debug tool to help identify a video
stream on a monitor.
•Caption Entry: User-defined caption.
Note: Text can be no more than 19 characters.
•Caption Scroll: Enables slow-speed horizontal scrolling of the caption within the
black text box. Scrolling is from right to left, and wraps around for continuous display.
•Caption Enable: The master enable – turns the caption display on and off.
8.3.6 Default Output
On input signal loss, select “black” to set output to black (default), or “pattern” to set output to
the test pattern. See section 8.3.4 for selection of the test pattern.
If the test pattern has been set to black, then if default output is chosen to be “p attern” , the
output will go to black on input loss.
When Freeze is enabled, the output picture displays a frozen frame picture.
8.3.8 Legalization
All color video signals are ultimately coded as RGB for display on a picture monitor. The
Legalizer ensures that the output video stays within the legal RGB gamut limit, making it
suitable for the broadcast signal chain. To achieve this, the Legalizer reduces the gain equally
on all channels.
The level the legalizer scales down to is selected from the options on the front panel.
Anything in the RGB space above the selected level is scaled down to that level. Anything in
the RGB space below 0 mV is clipped to 0 mV. This is a good compromise between
minimizing hue change and raising apparent brightness.
Legalizer choices are:
•Off (Default)
•700mV
•721mV
•735mV
•746mV
8.3.9 Logo Control
Logo control enables static or animated graphics to be keyed on to the video output of a
channel.
Logo files are uploaded to the KudosPro unit using a SAM application.
The application is available for download under the “Support” tab at:
To upload logos onto the MC500, run the logo upload application on your PC. A dialog box
will appear as shown below:
Enter the IP address of your unit and browse to the folder con t aining yo ur require d logos (see
section 7.7.1 and 10.6.1 for a summary of how to set the unit's IP address). Then click on the
Install Logo button. This will upload the logo to your unit.
This stage can take up to a minute depending on the length of the logo. Short or static
logos will upload in a few seconds.
Once the logo file(s) have been uploaded to the KudosPro unit they will be automatically
displayed in the Logo Selection box.
•A number of image file types are supported by KudosPro. For a full list of currently
supported image file types see the Supported Image File types Application Note
•A logo file must contain a key. If no key is found the entire image will be displayed
i.e. a rectangle cut-out of the logo image size
•Maximum logo size of 400 Pixels by picture height (Max. 480 lines)
Logo naming convention:
•All logo files take the form <logo_name><specifier>.<extension>
where <logo_name> equals the directory's name.
•Logo filenames must be all in lowercase.
•A <specifier> of the form _<standard> indicates that this logo is intended for this
specific standard. If no _<standard> specifier is included, then this logo is the
default for any standards which do not have a standard-specific logo.
Possible values for <standard> are: 525i, 625i, 720p, 1080p and 1080i.
•A <specifier> of the form _<index> indicates that this file is part of a multi-file
sequence for an animated logo. Any non-negative decimal value may be used for
<index>. The files in a sequence are sorted in increasing order of their respective
<index>es by numerical value. Leading zeros do not affect the sort order, and it is
not required that the <index> values are contiguous, however all images in a
multi-file sequence must have the same width and height.
•If both _<standard> and _<index> specifiers are used, then they should be written
as _<standard>_<index>, not _<index>_<standard>.
•The <extension> is ignored, the KudosPro unit will auto-detect the actual image
format.
Example logo file names:
•sam_1080p.png - a logo file for use with 1080p signals
•sam_720p_01.bmp, sam_720p_02.bmp and sam_720p_03.bmp
- three logo files in a multi file sequence
Features and Functions:
•All logos are available to for all channels
•Up to 64 logos can be stored on a KudosPro unit
•RGB graphic formats are automatically converted to SD and HD color spaces and
levels
•YUV graphic formats are presented as is for SD and HD
•YUV range is assumed to be 16 (black) to 235 (white). Other values are clipped.
•Key channel levels for all graphic formats are 0 (off) to 255 (100% key)
•Animations are always displayed as a sequence, static frames cannot be selected
•The maximum animation duration depends on the logo image size.
For example an animated logo image with a 10% raster size overlaid on 60Hz signal
is limited to a maximum of 10 seconds
•Sequence capacity of 10,000 pixels maximum.
(approximately 44 Seconds for 150 x 50 Pixels at 60 Hz)
•Interlaced video standards will treat each image of the original sequence as a single
field of the resultant animation. Frame to field conversion is performed by simply
removing those lines which should not be present in a particular field.
•Animations will not be displayed in the logo selection box until the upload is complete
•Animations will always start from the first frame of the sequence on 'Take'
•Animations can be loaded as a sequence of still images or a sequence of moving
video (e.g. MPEG) files. One animation can be created from a sequence of files of
different file types so long as the image size is the same in each file
•Animations are displayed at the output-side frame r ate. If an anim ation is desig ned to
be played at 50fps but the current output standard is 59Hz it will play out faster than
designed.
Logo Control Setup:
•Logo Selection: Select a logo for the current channel:
Select a logo by clicking on the logo name. The selected logo is highlighted. Click on
None Selected if no logo is required for the channel.
•H Position: Set the position of the left edge of the logo image from the left of the
screen as a percentage of the screen size. Adjustment range 0 to 100%.
0 = left edge of the logo is at the left edge of the screen.
•V Position: Set the position of the lower edge of the logo image from the bottom of
the screen as a percentage of the screen size. Adjustment range 0 to 100%.
0 = lower edge of the logo is at the lower edge of the screen.
•Transparency: Set the transparency level of the logo from 0 to 100%.
100% = Invisible
•Pre-Shaped: Sets the key format to Pre-shaped when checked and Linear when
unchecked.
When the key format is set to Pre-shaped it is possible to simply cross-fade between
background and foreground. This changes the edge shape of the logo but the
pre-processing of the key means that the final result will be the intended edge shape.
When Pre-shaped is not checked a linear key format is used and cross-fades
between background + foreground and for eground so the key follows the sh ape of the
logo.
•Take: Enables and disables logo display on the video output of the channel.
When Take is checked the logo is displayed on the video output of the channel.
•State: Displays the state of the selected logo. Typically this would be “Logo load
complete”
•Logo Selected: Displays the name of the selected logo.
•Delete: Deletes the currently selected logo. If the logo is in use this action will fail.
The Video menu enables you to apply various types of signal processing to the signal being
converted, and includes Proc Amp and Enhance controls.
8.4.1 Proc Amp
The Proc Amp (Process Amplifier) enables you to correct video inconsistencies, such as
contrast.
•Enable: Enables the Proc Amp.
•Contrast: Adjusts the contrast. The adjustment range is -6 dB to 6 dB in 0.2 dB steps.
The preset value is 0 dB.
•Saturation: Adjusts the color saturation. The adjustment range is -6 dB to 6 dB in 0.2
dB steps. The preset value is 0 dB.
•Black Level: Adjusts the black level. The adjustment range is -100 mV to 100 mV.
The preset value is 0 mV.
•Gamma: Adjusts the gamma curve. The adjustment range is 0.4 to 1.7 in 0.1 ste ps.
The preset value is 1.0.
•YC Offset: Adjusts the horizontal chroma shift, for use when correcting upstream
luma-chroma displacement. The adjustment range is -20 to 20 in steps of 2 luma
clocks.
At the input picture edge, zero chroma is shifted into the active picture area. If the
ARC is set to show less than the full width of the input picture, valid input picture
chroma is shifted into the output picture area.
The Nonlinear Enhancer defines the amount of enhancement applied to a video to help
regain lost detail. This could be as a result of degraded material, post production processes,
or because the initial capture conditions were not ideal.
The controls enable you to apply enhancement to the low, medium, and high frequency
bands, and to create a custom setting if required.
For more information about enhance processing, see the KudosPro Enhancer Application
•Level: Adjusts the level of enhancement from 0 to 192. The preset value is 0.
•Mode: Preset controls.
•Low: Sets Level to 2 and Noise Rejection to 15% for the selected frequency
band.
•Medium: Sets Level to 4 and Noise Rejection to 15% for the selected frequency
band.
•High: Sets Level to 6 and Noise Rejection to 15% for the selected frequency
band.
•Super: Sets Level to 8 and Noise Rejection to 15% for the selected frequency
band.
•Manual: Enables you to manually adjust the Gain and Noise Rejection controls.
•Frequency Band: S pecifies the frequency band to which the enhancement is
applied. You can choose from Low, Medium, and High.
•Noise Rejection: Enables you to manually adjust the Gain and Noise Rejection
controls. The adjustment range is 0 to 100 in steps of 1. The preset value is 0.
8.4.3 Enhance – Conversion Aperture
The Conversion Aperture menu enables you to control the horizontal and vertical rescaler
apertures from a range of presets.
8.4.3.1 Preset
Preset returns all settings to their default values.
The Convert menu enables control of motion processing to improve the conversion
performance of stationary content.
8.5.1 Motion Processing
•Motion Process: Enables motion compensation.
•Enhanced Motion: When used together with the Still Process option, Enhanced
Motion detects constant motion and applies a n aperture with full (progressive) ve rtical
frequency response.
•Still Process: Uses powerful motion detection techniques to extract the maximum
resolution from interlaced sources while format or standards converting. The benefits
of this processing are prominent on static logos and computer-generated overlays.
•Enhanced Still: Adds field motion detection to still processing. This prevent s artifact s
on moving repetitive patterns.
•Enhanced Film: Applies an aperture with full progressive frequency response where
the input is film transported by an interlaced video rate input, with cadence enabled.
•Enhanced De-interlace: Replaces missing lines with a gradient between the
previous and following lines. This control improves the appearance of de-interlaced
images and is useful when dealing with complex shapes.
•Clean Cut: Prevents temporal filtering across a cut in scenes, which can result in
several frames either side of the cut being a mix of the two different scenes.
For more information about motion proc essing and en hanced film settings, see the KudosPro Still Mode Application Note and KudosPro Film Mode Application Note, under the “Support”
tab at:
•Clean Edge Upconversion: Enables the Texture Adaptive Upconversion (TAU)
process. TAU helps to adapt away any horizontal ringing (vertical edges), co mmon in
very high-frequency graphics.
Input Cadence enables you to define any cadence associa ted with the input video.
•Film Cadence: Enables the processing of film-originated content transported by a
cadence.
•59 Cadence: For standards with a field rate of 59 Hz and with cadence enabled, you
can choose either 2:2 or 2:3 (psf).
Note: Standards with field rate of 50 Hz and with cadence enabled are interpreted as
2:2.
•2:3 Source: Selects whether a 2:3 cadence is determined automatically or derived
from the input timecode.
•Automatic: The cadence detection circuit automatically detects the cadence.
This is useful when the source material contains mixed cadences.
•Input Timecode: Defines the relationship between timecode and the 2:3
sequence. This is useful when the source material contains known, continuous
2:3.
•2:3 Start Hour: Sets the starting hour for the timecode (when 2:3 Source is set to
Input Timecode). The adjustment range is from hour 0 to hour 23 in one-hour steps.
8.5.4 Output Cadence
Output Cadence enables you to define the required cadence of the output video.
•Film Cadence: Enables the cadence of the output content.
•59 Cadence: For standards with a field rate of 59 Hz, you can choose either 2:2 or 2:3
(psf) cadence generation.
Note: Standards with field rate of 50 Hz are interpreted as 2:2.
•2:3 Source: Selects whether a 2:3 cadence is free-running or derived from the output
timecode.
•Free Run: In Free Run mode the output 2:3 cadence is undefined. The output
will have continuous 2:3, but may vary from conversion to conversion.
•Output Timecode: Defines the point at which the 2:3 sequence starts relative to
timecode.
•2:3 Start Hour: Sets the starting hour for the timecode (when 2:3 Source is set to
Output Timecode). The adjustment range is from hour 0 to hour 23 in one-hour steps.
The Aspect Ratio Control (ARC) menu enables you to determine the aspect ratio of a pictu re
from a range of options, or to adjust the size and position of the picture manually.
8.6.1 Sync Mode
The Sync Mode control disables the ARC feature when input and output formats are the
same. This gives the lowest latency.
8.6.2 Signaling Detected
Signaling Detected shows the status of any aspect ratio signaling detected at the input.
8.6.3 Sidebar Keying & Output Crop
The Sidebar Keying & Output Crop functionality provides post ARC cropping of the output
picture and allows a second video picture to be keyed into the cropped area. When output
cropping is enabled, the actual size of the output picture does not change, just how much of
the active picture remains visible. The portion that is “cropped” is either default black (in
Output Crop mode) or is replaced by a secondary video picture (in Sidebar Key mode) – the
“cropped” portion still forms part of the output picture.
For more information about sidebar keying, see the Sideba r Keyer Application Note under the
“Support” tab at:
•Off: Disables both Output Crop and Sidebar Keying.
•Output Crop: Crops the output picture. In this mode the cropped area is black by
default. The cropped area is defined using the Output Crop Position controls. See
“Output Crop Position” on page 55.
•Sidebar Key: Keys a second video picture into the cropped area, as defined using
the Output Crop Position controls (see “Output Crop Position” on page 55). When
selected, the source of the second video picture is becomes available in the Sidebar
Key Source menu. See page 55.
If the sidebar key option is available, the Sidebar Key Source control will also be present. This
control becomes active when Sidebar Key mode is selected. Firstly a border is set up around
the active picture using the separate Output Crop Position controls. This control then selects
the secondary video source to be keyed over the border area.
In order for this to work correctly, the following rules must be met:
•Sidebar Key Source must be of the same format and frame rate to the output video
standard for this channel.
•If the key source selected is of a d if fer ent st a ndard to th e main vid eo ou tput st an dard,
only Output Crop Mode is available.
•Ensure the key source has the correct vertical genlock alignment. If not, the sidebar
key will not have the correct vertical position.
The available sidebar key sources vary depending on the product variant:
•Single-channel product: all video inputs are available.
•Dual-channel product: all video inputs are available.
All video inputs is Serial SDI, CVBS, and SFP.
Sidebar Key Source options that are not available to the product are hidd en from the selection
list (for example, the output of the second channel in a single-channel product, or SFP input if
no SFP rear is fitted).
Sidebar Key Source options that are not suitable are grayed out from the selection list (for
example, the source is the not the same output standard as the video it is being “keyed” into,
or SFP 2 is actually a TX so is not available as an input.
8.6.3.3 Output Crop Position
The Output Crop position controls enable you to adjust which portion of the video picture is
visible by applying a border around the outside of the picture. The controls do not alter the
output active picture size – each control separately defines a percentage of the picture to be
replaced by a border . In Output Cro p mode, the border is d efault black. In Sidebar Key mo de,
the border is the “key” area replaced by the secondary Sidebar Key video source.
Controls are paired: top with bottom and left with right. A pair of controls has limitations to
prevent an overlap. The rule is that only 99% o f the picture can be cropped, either horizon tally
or vertically. For example, if Top is set to 50%, Bottom cannot exceed 49%.
•Top: Crops the output picture, from the top-edge down. The adjustment rang e is 0%
to 99% in 1% steps (0%). The default is 0%.
•Bottom: Crops the output picture, from the bottom-e dg e up . The ad justm ent r ange is
0% to 99% in 1% steps. The default is 0%.
•Left: Crops the output picture , from the lef t-ed ge right. The adjustment ra nge is 0% to
99% in 1% steps. The default is 0%.
•Right: Crops the output picture, from the right-edge left. The a djustment range is 0%
to 99% in 1% steps. The default is 0%.
Post Scaling Control enables you to adjust the size and position of the picture manually.
•Post Scaling Enable: Enables the Post Scaling controls.
•Size: Adjusts the size of the whole output image while maintaining aspect ratio. The
adjustment range is 80% to 120% in 1% steps. The preset value is 100%.
•Aspect: Adjusts the aspect ratio of the output image. The adjustment range is 70% to
150% in 1% steps. The preset value is 100%.
•Pan: Adjusts the horizontal position of the output image . The adjustment ran ge is -50
to 50 in steps of 1. The preset value is 0.
•Tilt: Adjusts the vertical position of the output image. The adjustment range is -50 to
50 in steps of 1. The preset value is 0.
8.6.5 Scaler Config – Presets
If no input aspect signaling is available and the conversion required is always from a known
input aspect ratio to another known input aspect ration, one of the standard presets may be
selected. The presets are sub-divided into SD to SD cross conversion, SD to HD/3G up
conversion, and HD/3G to SD down conversion.
These presets are only active when the Use Presets check box is selected.
8.6.5.1 SD Input is 702
SD Input is 702 is an additional ARC preset mode, which is available for incoming content
that uses a 702 sample line rather than a 720 sample line. If the incoming content uses a 702
sample line, select the check box. This introduces an additional H scaling factor of 720/702,
resulting in a slight horizontal stretch.
This control only has an effect on SD inputs.
702 input introduces an additional H factor of 720/702.
SD Output is 702 is an additional ARC preset mode, which is available for outgoing content
that requires a 702 sample line rather than a 720 sample line. If the outgoing content requires
a 702 sample line, select the check box. This introduces an additional H scaling factor of
702/720, resulting in a slight horizontal squeeze.
This control only has an effect on SD outputs.
SD Output 702 introduces an additional H scaling factor of 702/720.
8.6.5.3 SD Cross Conversion – Select Standard Preset
LB = letterbox, h-crop = horizontal crop, ana = anamorphic.
When using input aspect signaling with an SD or HD input source, it is possible to set a
default input ARC setting. If, for any reason, the input aspect signaling cannot be detected,
the ARC assumes this default setting.
•Force Input Format: Enables manual ARC control, which will force the aspect ratio
conversion if the input aspect signaling cannot be detected.
•SD Input Format: The SD input format.
•Normal: Default 4:3 aspect ratio.
•Anamorphic: Horizontally squeezes a widescreen image to fit a standard 4:3
aspect ratio.
•16:9 Letterbox: Preserves the original aspect ratio of film shot in a widescreen
aspect ratio, with bars visible at the top and bottom of the screen.
•14:9 Letterbox: A 14:9 letterbox image in a 16:9 frame.
•HD Input Format: The HD input format.
•Normal: Default 4:3 aspect ratio.
•14:9 Pillarbox: A 14:9 pillarbox image in a 16:9 frame.
•4:3 Pillarbox: A 4:3 pillarbox image in a 16:9 frame.
The Output Config functions define which of the supported aspect signaling st andards defines
the input of the ARC.
8.6.7.1 Conversion Scaling
Conversion Scaling enables you to set fixed ARC output aspects.
•Fit to Height: Scales the image to fit the height of the screen while maintaining the
aspect ratio.
•Fit to Width: Scales the image to fit the width of the screen while maintaining the
aspect ratio.
•14:9: Can scale either a 4:3 image for viewing on a 16:9 screen, or a 16:9 image for
viewing on a 4:3 screen. This is a compromise in order to maintain the aspect ratio of
the image, but will crop some of the image in the process (top and bottom when
viewing 16:9 and left and right when viewing 4:3).
See “Input Signaling ARC Conversions” on page 62 for a list of possible ARC conversions
using input signaling and a combination of SD Output Format and Conversion Scaling
controls.
8.6.7.2 SD Output Format
When the output video is SD, this control enables you to set fixed output aspects for the ARC.
•Normal: Default aspect ratio.
•Anamorphic: Horizontally squeezes a widescreen image to fit a standard 4:3 aspect
ratio.
It is possible to manually fix the output aspect of the ARC when using input signaling. The
input to the ARC is then defined by the dynamic input signaling.
The following sections show the ARC conversions possible using input signaling and a
combination of SD Output Format and Conversion Scaling controls. For each of the
conversions there are four columns of images. The first column shows the source image in
various formats, with each format described in the accomp anyin g input signal. The next three
columns show the output image format when the Fit to Width, 14:9, or Fit to Height
Conversion Scaling controls are selected.
Alternate center cut is off by default. When off, behavior on receipt of certain specific AFD
codes ignores protected regions. When Alternate center cut is on, the ARC beha vior for these
six specific codes will be to remove any Black bars and also remove the grey bars that will
leave the “Alternative Centre”. The Alternative centre will therefore be stretched to fit the
screen so that the whole “white area” fills the screen. This will override Fit to width, 14:9 and
Fit to height setting, so that all three give the same output result. It also overrides the
“SD Output Format” control (“Anamorphic” or “Normal”). See SMPTE ST 2016-1 :2009,
pages 7, 8 and 9.
The behavior with Alternate center cut on and off is shown in the table below:
AFD Format
Interpretation with
Alternate Centre Cut Off
4:3 AFD 134:34:3 Alt 14:9
4:3 AFD 1416:9LB16:9LB Alt 14:9
4:3 AFD 1516:9LB16:9LB Alt 4:3
16:9 AFD 134:3PB4:3PB Alt 14:9
16:9 AFD 1416:916:9 Alt 14:9
16:9 AFD 1516:916:9 Alt 4:3
The Output Signaling Config controls define which of the supported aspect signaling
standards defines the input of the ARC.
8.6.9.1 SMPTE 2016
The SMPTE 2016 controls define how the SMPTE 2016 signaling is con f igured . T he co ntrol s
also enable you to choose the output line number on which output signaling is embedded.
•Mode: Four modes of operation are available.
•Auto: Automatically generates an output SMPTE 2016 signal with AFD data that
matches the output aspect of the ARC.
•Pass: Passes input signal information through the unit unchanged when SMPTE
2016 is selected as the input signaling source.
The output signal may not represent the actual aspect of the output image. If no
SMPTE 2016 signal is present at the input, no SMPTE 2016 signal will be output.
•Force: Generates an output SMPTE 2016 signal with AFD data that matches
what is selected in the Force Mode Config – SMPTE 2016 list. The list contains
16 AFD codes for coded frame AR of 4:3, and eight AFD codes for a coded frame
AR of 16:9.
•Delete: Disables embedding of SMPTE 2016 output signaling in the output video.
•Output Line PAL: Selects the line number on which SMPTE 2016 signaling is
embedded when the video output format is 625. The range is from line 7 to line 22 in
one-line steps. The default is line 12.
•Output Line NTSC: Selects the line number on which SMPTE 2016 signaling is
embedded when the video output format is 525. The range is from line 11 to line 19 in
one-line steps. The default is line 11.
•Output Line HD: Selects the line number on which SMPTE 2016 signaling is
embedded when the video output format is HD. The range is from line 9 to line 20 in
one-line steps. The default is line 11.
•Output Line Status: Shows the output line number on which SMPTE 2016 signaling
is embedded. If no line number is selected, “OFF” is displayed.
In the SD domain, take care to avoid a line clash if embedded VITC and SMPTE 2016 are
both enabled. VITC will take priority and overwrite the SMPTE 2016 packet if the same
output line is selected for both.
The Video Index (VI) Config controls enable you to specify VI signaling output actions.
VI is valid for both 625 and 525 output video formats. The lines used are:
•625: Field 1 line 11, field 2 line 324.
•525: Field 1 line 14, field 2 line 276.
VI signaling supports two output formats, which are the two versions of the SMPTE RP 186
specification.
•Mode: Output options.
•Auto: When Output Format is set to SMPTE, Auto generates an output VI signal
conforming to SMPTE RP 186-95 with scanning system information that matches
the output aspect of the ARC. If Output Format is set to AFD, Auto generates an
output VI signal conforming to SMPTE RP 186-08, with scanning system
information and AFD that matches the output aspect of the ARC.
•Pass: When either VI SMPTE or VI AFD is selected as the input signaling
source, any valid SMPTE RP 186-95/08 input signal is passed through to the
output unchanged irrespective of what output format is set. For both output
formats, the output signal may not repr esent the actual aspect of the output
image. If no VI signal is present at the input, then no VI signal will be output.
•Force: When Output Format is set to SMPTE, Force generates an output
SMPTE RP 186-95 signal with scanning system information that matches what is
selected in the Force Mode Config – SMPTE RP 186 list. 4:3 and 16:9 are
available, but the actual code used is determined by the output video standard:
625 or 525.
When Output Format is set to AFD, Force generat es an ou tpu t SM PTE RP
186-08 signal with scanning system information and AFD codes that match what
is selected in the Force Mode Config – AFD list. The list contains eight AFD
codes for scanning 4:3 system information, and eight AFD codes for scanning
16:9 system information. The actual scanning system information used is
determined by the output video standard: 625 or 525.
•Delete: Disables embedding of any SMPTE RP 186-95/08 o utput signaling in the
output video.
•Output Format: Output format options.
•SMPTE: Generates output VI signaling conforming to SMPTE RP 186-95,
carrying just the scanning system information relating to the output aspect of the
ARC.
•AFD: Generates output VI signaling conforming to SMPTE RP 186-08. This
carries the scanning system information as well as AFD codes relating to the
output aspect of the ARC. (This specification was originally generated as
ARDSPEC1 by several Major UK broadcasters and later incorporated into
SMPTE RP 186 2008 version.)
•VI Pass Data: Allows passing of VI user bits data to the output video. Note that the
input signaling source selected has to match the selected output format.
The L23 Config controls define how the output ETSI EN 300 294 signaling is configured. This
signaling format is generally referred to as WSS or Line 23 (L23), as this is the default line
used to carry this signal in 625. WSS is only valid for 625 output video formats and is only
supported for 625 output video format.
WSS signaling supports two output format s: ETSI EN 300 294, an d a non- st and ard varia nt of
ETSI EN 300 294.
•Mode: Output options.
•Auto: If Output Format is set to ETSI, Auto generates an output WSS signal
conforming to ETSI EN 300 294, with AFD codes that match the outpu t aspect of
the ARC. If Output Format is set to AFD, Auto generates an output WSS signal
conforming to L23, with scanning system information and AFD codes that match
the output aspect of the ARC.
•Pass: When either L23 ETSI or L23 AFD is selected as the input signaling
source, any valid ETSI EN 300 294 input signal is passed through to the output
unchanged irrespective of what output format is set. For both output formats, the
output signal may not represent the actual aspect of the output image. If no WSS
signal is present at the input, then no WSS signal will be output.
•Force: When Output Format is set to ETSI, Force generates an output ETSI EN
300 294 signal with AFD codes that match what is selected in the Force Mode
Config – ETSI list. The list contains eight AFD codes.
When Output Format is set to AFD, Force generates an output ETSI EN 300 294
signal that is modified to carry VI scanning system information and AFD codes
that match what is selected in the Force Mode Config – AFD list. The list contains
eight AFD codes for scanning 4:3 system information, and eight AFD codes for
scanning 16:9 system information. The actual scanning system information used
will always be 625, as WSS is only supported in 625 video output.
•Delete: Disables embedding of ETSI EN 300 294 output signaling in th e outp ut
video.
•Output Format: Inserts L23 information in either AFD or ETSI format.
•ETSI: Generates output WSS signaling conforming to ETSI EN 300 294, carrying
just the AFD codes relating to the output aspect of the ARC.
•AFD: Generates output WSS signaling conforming to ETSI EN 300 294;
however, payload of the signal has alternative meaning: it has been modified to
carry Video Index Scanning system information and AFD codes relating to the
output aspect of the ARC. (This specification was originally generated as L23
spec by several major UK broadcasters and manufacturers. It has never been
released as an official standard).
•Input Line: WSS information is generally carried in the fist half of line 23; however, if
the information is required on a different line, use the slider to specify the line on
which it is carried in the input. The range is from line 10 to line 23 in one-line steps.
Note: ETSI EN 300 294 signaling will only be extracted from this line number if the
video input format is 625.
•Output Line: WSS information is generally carried in the first half of line 23; however,
if the information is required on a different line, use the slider to specify the line on
which it is carried in the output. The range is from line 10 to line 23 in one-line steps.
Note: ETSI EN 300 294 signaling will only be extracted from this line number if the
video input format is 625.
•Output Line Status: Shows the output line number on which WSS information is
carried. If no line number is selected, “OFF” is displayed
•AFD User Bits:
•Force User Bits Value: Forces the value set on the User Bits Value slider into
the L23 output.
•User Bits Value: Sets the line on which the four additional user bits are carried.
WSS output signaling is only available in SD 625 output video format.
8.6.10 Output Signaling Config – Force Mode Config
Force Mode Config enables you to define the scanning system information and AFD codes
inserted in the output signaling when Force is selected for any of the following three signaling
types: SMPTE 2016, VI SMPTE RP 186, and WSS ETSI EN 300 294.
•SMPTE 2016: When SMPTE 2016 output signaling mode is set to Force, this control
offers a list of 16 AFD codes for coded frame AR of 4:3 an d the same AFD codes for a
coded frame AR of 16:9. Selecting one will generate a SMPTE 2016 output signal.
•SMPTE RP186: When VI output signaling mode is set to Force and output format is
set to SMPTE, this control offers a list of two scanning system information codes: 4:3
and 16:9. The actual code used is determined by the output video standard: 625 or
525. Selecting one will generate a SMPTE RP 186-95 output signal.
•AFD: When VI or L23 output signaling modes are set to Force, and their output
formats are set to AFD, this control offers a list of eight AFD codes for scanning
system information of 4:3, and eight AFD codes for scanning 16:9 system information.
The actual scanning system information used is determined by the output video
standard: 625 or 525. Selecting one will generate the following output signaling:
•SMPTE RP 186-08: VI mode = Force, Output Format = AFD.
•ETSI EN 300 294 (with SMPTE RP 186-08 payload): L23 mode = Force, Output
Format = AFD.
•ETSI: When WSS output signaling mode is set to Force and output format is set to
ETSI, this control offers a list of eight AFD codes. Selecting one will generate a ETSI
EN 300 294 output signal.
For schematic information on audio routing, see “Block Diagrams” on page 15.
AES and analog audio are controlled at a frame level, not at a channel level.
To route the AES and analog audio outputs, see “Audio Routing” on page 32.
For more information about audio routing, see the Audio Processing Application Note under
The Status list shows the status of the audio output pairs.
The audio status display information is as follows:
•P = PCM
•L = Loss
•N = Non-PCM
8.7.2 Control
The Control menu enables you to adjust the gain of the audio channels
8.7.2.1 Gain
•Pair 1–8 L/R: Adjust the gain of the left and right channels of the audio pairs. The
adjustment range is -12 dB to 12 dB in 0.1 dB steps. The preset value is 0 dB.
8.7.2.2 Tone Frequency
The Tone Frequency slider adjusts the frequency of the test tones. The adjustment range is
0.1 KHz to 10 KHz in 0.1 KHz steps. The preset value is 0
•Each embedded pair (EMB1/2 to EM15/16) has its own individual tone generator.
•AES can be balanced or un-balanced. Only four pairs of AES can be processed.
•Analog audio processing is limited to four pairs.
•Analog and AES outputs are derived from Embedded pairs, hence test-tones follow
Embedded audio settings.
8.7.2.3 Dolby E Alignment Offset
The Dolby E Alignment Offset slider sets the guard-band position of any output pair
containing Dolby E, to allow for downstream processing. By default, the position of the
guard-band is set automatically, and is dependent on the output standard.
8.7.2.4 Delay
The Delay controls enable you to set delay pa ir offsets and the audio delay relative to the
video delay.
•Global Delay Pair Offsets: Global delay offsets for pair 1–8.
•Global Delay: Global delay settings for pair 1–8.
•Pair 1–8: Adjusts the audio delay offset for ea ch of the eig ht audio ch annel p airs.
The adjustment range is -40 ms to 200 ms in 1 ms steps.
The preset value is 0 ms.
•Pair 1–8 Total: Shows the current total pair delay.
•Audio: Adjusts the audio delay relative to the video delay. The adjustment range
is -40 ms to 200 ms in 1 ms steps. The preset value is 0 ms.
•Audio Total: Shows the current total audio delay.
•Video Total: Shows the current total video delay.
Global delay is applied to all channels. Individual channel delays are added/subtracted
from this delay.
For more information about audio control, see the Audio Processing Application Note under
the “Support” tab at:
The Shuffle menu contains the output information from the audio processors, as defined on
the Routing screen.
8.7.3.1 Output Pairs 1–8 L/R
•Process Pairs Source: For each of the output pairs, 1–8, you can select the audio
source to be routed to the output.
Note: Certain rules determine which combinations are valid. An invalid combination
will force the output to silence. The following table shows the rules that govern output
pair combinations:
Non-PCMPCMToneSilenceLoss
Non-PCMN or FFFFF
PCMFPPPF
ToneFPTPF
SilenceFPPSF
LossFFFFF
P = PCM, N = non-PCM, S = silence, T = test tone, F= forced mute (silence).
•Invert Phase: Enables you to invert the phase of the left and right audio channels.
This control is useful for dealing with input audio discrepancies.
•Control: Control options.
•Use Routing: Routes the audio output from the audio processor.
•Tone: Makes the audio input source a test tone.
•Silence: Mutes the audio input source.
For more information about audio routing, see the Audio Processing Application Note under
the “Support” tab at:
The Timecode menu enables you to set up and control the unit’s timecode options for VITC
(Vertical Interval Timecode), LTC (Linear Timecode), and ATC (Ancillary Timecode).
For HD video inputs, ATC LTC and ATC VITC timecode data formats are supported. For HD
video outputs, the timecode data format is fixed to ATC VITC. This is present in all HD video
outputs if Follow Input mode is selected (with a valid input timecode detected), or if Generate
mode is selected.
For SD video inputs, VITC, ATC LTC and ATC VITC timecode data formats are supported.
For SD video outputs, the timecode data format is fixe d to VITC. This is present in all SD
video outputs if the VITC Enable check box is selected, and either Follow Input mode is
selected (with a valid input timecode detected), or Generate mode is selected.
Where the input frame rate is 29.97 fps, both drop frame and no n-drop frame modes are
supported. For 29.97fps outputs, timecode can be configured as either drop frame or
non-drop frame.
External LTC timecode is not supported.
8.8.1 Source (HD/SD)
The Source controls enable you to choose a timecode type from the input: LTC or VITC for
HD, and VITC, ATC LTC, or ATC VITC for SD.
For HD video standards, the supported input timecode format is ATC. This means that
timecode data formatted as LTC, VITC, or both will be detected at the input; however, only
one format can be selected.
•LTC: Select ATC LTC only if detected when video input is HD.
•VTIC: Select ATC VITC only if detected when video input is HD.
If the selected format is not detected at the input, no timecode processing will be available.
For SD video standards, the supported input timecode formats are VITC and ATC. As with
HD, A TC can mean that timecode data formatted as LTC, VITC, or both will be detected at the
input; however, only one format can be selected.
•VITC: Select VITC only if detected when video input is SD.
•ATC LTC: Select ATC LTC only if detected when video input is SD.
•ATC VTIC: Select ATC VITC only if detected when video input is SD.
If the selected format is not detected at the input, no timecode processing will be available.
8.8.2 Status
Status reports which type of embedded timecode is detected within the video input to this
processing channel.
•Follow Input: The input timecode is read every frame and the actual time elapsed
since timecode 00:00:00:00 is calculated. This elapsed time is then converted into an
output timecode that matches the output video frame, and inserted into the output.
There is an additional process to compensate for clock offset between in and out,
which will generate repeated or skipped timecodes as necessary, just as happens
when synchronizing at the same standard. If the output is clock-locked to the input,
this process has no effect.
•Generate: The unit generates the output timecode internally to match the output
video standard. You can specify a start time in the Timecode Entry field. See
““Timecode Entry” on page 77”.
•Input Trigger: The unit generates the output timecode from a specified input
timecode trigger. You can specify a trigger and start time in the Input Trigger Entry
and Output Timecode Entry fields.
8.8.4 VITC Enable
VITC Enable embeds the VITC in the SD output.
This control only enables the embedding of VITC. In order for VITC to be present in the
output SD video, a valid timecode must be detected at the input when in Follow Input
mode, or when Generate mode is selected.
8.8.5 Output Line (525)
The Output Line (525) slider selects the output line on wh ich VITC is placed when the channel
output is 525. The range is from line 11 to line 17 in one-line steps. The default is line 14.
8.8.6 Output Line (625)
The Output Line (625) slider selects the output line on wh ich VITC is placed when the channel
output is 625. The range is from line 7 to line 20 in one-line steps. The default is line 19.
The line number stated is the first of the two lines used to embed VITC. The second line
will always be the line selected + 2. For example, the default line for 525 is 14. Therefore
VITC will be embedded on lines 14 and 16.
8.8.7 Output Line Status
Output Line Status shows the actual output line number on which SD VITC packets are
inserted. If no line number is selected, “OFF” is displayed.
If the line selected is already in use, the VANC embedding hierarchy will place the SD
VITC packet on the nearest available line.
8.8.8 Input Trigger Entry
In the Input Trigger Entry field you ca n enter a value to specify when the output timecode
starts. Once set, the output timecode will start when the video source input timecode reaches
the trigger value set in the Input Trigger Entry field.
In the Output Timecode Entry field you can enter a value to specify when the output timecode
starts. Once set, the output timecode will start when the input timecode reaches the trigger
value set in the Input Trigger Entry field.
8.8.10 Timecode Entry
In the Timecode Entry field you can enter a value to specify when the internally generated
timecode starts. Once set, the internally generated timecode will start when you select the
Timecode Load button.
8.8.11 Timecode Load
Timecode Load enables you to manu ally trigger the internally ge nerated timecode, as defined
in the Timecode Entry field.
8.8.12 On Timecode Loss
On Timecode Loss defines how the embedded output timecode should behave if input
timecode cannot be detected.
•Freeze: On timecode loss, the output timecode will freeze at the last valid detected
input value, until the valid input returns.
•Free Run: On timecode loss, the output timecode will switch to free-run and generate
its own timecode starting from the last valid detected input value, until the valid input
returns.
8.8.13 Non Drop Frame
Output timecode always follows the correct count sequence for the output standard, except
when following an input timecode that does not represent actual time (except if the input is
flagged as 59 non-drop).
Drop Frame operates as follows:
•When converting timecode from 29/59 Hz to 29/59 Hz standards, the output
drop-frame type automatically matches the input (the Drop Frame control has no
effect).
•When using the internal timecode generator with a 29/59 Hz output standard, the
drop-frame type is determined by the Drop Frame control.
•When converting 23 Hz inputs to anything, follow input will give a broken sequence.
The Metadata menu enables you to control a set of closed captions and teletext subtitle
information.
Incoming SD or HD closed captions and subtitles are converted to the correct format in the
HD or SD output when upconverting or downconverting at the same frame rate.
8.9.1 Closed Captions
Closed Captions covers CEA-608 and CEA-708 specified captioning. Although these
specifications support captioning in multiple video standards, CEA-608 is only supported in
525 input or output as a line 21 signal. CEA-708 is only supported in 59 Hz HD video
standards as a VANC packet with a Caption Distribution Packet (CDP) payload.
Closed Caption pass-through is possible if a valid input closed caption is pres en t an d inp u t
and output video standards are the same.
Closed Caption transcoding is supported from CEA-608 to CEA-708 by taking the decoded
bytes from the line 21 signal and inserting them into the compatibility byte within the CDP.
Transcoding from CEA-708 to CEA-608 is possible if the CDP contains a compatibility bytes,
which are extracted and encoded as an output line 21 signal.
Closed captions are automatically detected in the input video, and the detected format shown
in the Status window. For closed captions to be embedded in the output video, they must be
enabled. User control for on which line to embed CEA-708 is provided, but CEA-608 is always
fixed at line 21.
•Input Status: Shows if CEA-608 or CEA-708 captions are detected on the input.
•CEA-608/708 Output Enable: Enables embedding of CEA-608 captioning as a line
21 signal in 525 output video, and CEA-708 captioning as an embedded VANC
packet in 59 Hz HD output video.
Note: The Output Enable controls only enable embedding of output closed captioning.
For closed captioning to be present in the output video, valid input closed captioning
must be detected, and you must select the correct output standard to support
pass-through or transcoding.
•CEA-708 Output Line: Selects the output line on which to insert CEA-708 VANC
packets. The range is from line 8 to line 20 in one-line steps. The default is line 10.
•CEA-708 Output Line Status: Shows the actual output line number on which
CEA-708 VANC packets are inserted. If no line number is selected, “OFF” is
displayed.
Note: If the line selected is already in use, the VANC embedding hierarchy will place
the CEA-708 packet on the nearest available line.
The unit can pass World System Teletext (WST) for SD and RDD-08 or SMPTE 2031 teletext
for HD. You can enable or disable teletext output and specify the input and output lines used.
Teletext covers World System Teletext (WST) subtitles, SMPTE RDD-08 and SMPTE 2031.
For WST and RDD-08, only subtitle information is supported or processed. SMPTE 2031
VANC packets may be teletext subtitles, non-subtitles, or inverted teletext.
WST is only supported in 625 input or output encoded signals. RDD-08 is only supported in
50 Hz HD video standards as a VANC packet with a Subtitling Distribution Packet (SDP)
payload. Teletext subtitle transcoding is supported from WST to RDD-08 by taking the
decoded bytes from the WST signal and inserting them into the payload within the SDP (see
below). Transcoding from RDD-08 to WST is only possible if the SDP contains valid subtitles,
which are extracted and encoded as an output WST signal.
Menu ChoiceOperation
625 captions•WST (Default)
•CEA-608
SD VBI setupWST Origin Line 7 to 22•Off (default)
•Enable
WST Origin Line 7 to 22
Reports WST status of each input line
Status
WST OP Line 7 to 22
Reports status of each output line
Status
Allow WST Remap•Off (default)
•Enable
WST Origin Line Select from 7 to 22 using slider or numeric entry
Default is line 10
WST Origin Line Status Reports status of the origin line
WST Output LineSelect from 7 to 22 using slider or numeric entr y
Default is line 10
WST Output Line Status Reports the chosen output line
Note: Only one WST origin line may be remapped
Teletext pass-through is possible if a valid input teletext subtitle is present and input and
output video standards are the same. For SD video that uses a large number of WST VBI
(where the VBI may have multiple lines of WST and 2 Timecode lines) the unit can
encode/decode/transcode up to 15 lines of WST. In up and down conversion applications, this
would use up to 3 RDD-08 (OP47) packets. RDD08 OP47 allows for 15 lines of WST to be
encoded. SMPTE2031 allows only 5 lines of WST to be encoded.
You can select which input lines of WST are encoded on the output (see instructions for SD
VBI line setup below). For the lines selected the status of WST being detected on that line is
reported back.
The unit allows for up to 15 lines of WST to be selected on the input. If valid WST is detected
on the selected lines, they will be placed on the same lines on the output. The status for each
line will be reported back.
It is also possible to remap one WST origin line. In this case, select Allow WST remap (see
menu list table on page 79). If valid WST is detected on the line selected by “WST origin line”
it will be put on the line selected by the user control “WST output line”.
Only one WST origin line may be remapped.
625 Input - HD Output
In applications where the video is upconverted, you can select which lines of WST are
encoded.
1.If RDD08 (OP47) conversion is selected, then up to 15 lines can be encoded in the
RDD-08 packet. A maximum of 3 packets are allowe d on the output, each with
individual line number controls. The number of output RDD-08 packets on the output
is decided by the number of valid WST lines decoded on the input. The first five WST
lines are encoded in the first RDD-08 packet, th e next 5 in the seco nd RDD-08 p acket
and so on.
2.If SMPTE2031 conversion is selected, then the first 5 lines selected on the input are
encoded in the 2031 packet. Each single WST line corresponds to one SMPTE2031
packet on the output. All packets will be placed on the same line selected by the user
control (see control Output Line All PKTs in the menu list table on page 79). The Data
Unit ID can be set to Teletext, Non-Teletext or Inverted Teletext.
HD Input - HD Output
You can select which input HD WST packet is to be decoded - RDD-08 or SMPTE2031.
Cross-conversion between the packet types is allowed. The option to select individual WST
lines contained in the input packets is still available using the WST origin and status menu
items. This is because both the SMPTE2031 and RDD-08 packet contain within them the
original source SD line number information. The input line selection refers to this line number
and not the ANC packet position line number.
HD Input - 625 Output
You can select which input HD WST packet is to be decoded - RDD-08 or SMPTE2031. You
can specify which lines of WST to encode on the output using the WST origin and menu item.
The WST lines will be encoded on the line number information encoded within the input HD
packet, unless “Allow WST rema p” is selected in which case you can change the line number
for one WST line on the output (similar to the SD to SD case described above).
The Memory menu enables you to save up to eight memory setups and recall them when
required.
You can change the default memory names to more relevant ones if required.
Memories set at a channel level save all parameters associated with the processing channel
including:
•Input routing
•Output standard and aspect ratio controls
•Video processing settings such as proc amp settings and enhancer parameters
•Conversion options such as Still Process
•Signaling parameters
•SDI output audio routing
•PCM audio controls (gain, delay, L/R swap)
•Timecode settings
•Closed caption processing choices
8.10.1 Memory Select
Memory Select lists the eight available memories.
8.10.2 Save Memory
Use the Save Memory button to save a new memory.
8.10.3 Recall Memory
The Recall Memory list recalls the settings saved in a memory location.
8.10.4 Reset to Defaults
Reset to Defaults recalls all the unit’s default memory settings at a channel level. All controls
are reset back to their preset values.
2.Select the text box.
The text entry cursor appears.
3.Press an Alphanumeric button, 1 to 8, rep eatedly until the de sired ch aracte r appear s.
If the next character you want is on the same button as the present one, wait u ntil the
cursor blinks once before pressing the button again.
•To enter a space between characters, press button 0.
•To enter a special character, such as the @ symbol, press button 9.
•To delete a character, press the Back button.
To save a memory name:
•From the Save Memory menu, select Save Memory.
8.11RollCall
The RollCall menu enables you to name the unit for use remotely with the RollCall Control
Panel. For more information on the RollCall Control Panel, see page 84.
8.12Logging
Logging defines what parameter information is made available to a logging device attached to
the RollCall network.
You can select to enable logging and view the status of the following parameters:
•Input Ident
•Input Standard
•Input State
•Output Ident
•Output Standard
•MSG Status
MSG Status shows a confirmation message that the log server is running.
In addition to the front panel, the RollCall Control Panel enables you to control the MC500 unit
through various different screens.
Refer to the RollCall Control Panel Installation & Operator’s Manual for information on
installation and setup of the RollCall Control Panel.
9.1Opening the System Setup Screens
The system setup screens contain all of the menu lists, options, and controls available for
setting up the unit.
To open the system setup screens:
•At the top of the RollCall network tree, right-click the product name and select
Connect.
The Input screen is displayed.
9.2Opening the Channel Operation Screens
The channel operation screens contain all of the menu lists, options, and controls available
for performing signal processing, fra m e ra te , an d for m at conversions.
To open the channel operation screens:
•On the RollCall network tree, double-click the channel name.
The list at the top-left of each screen shows each template
screen available for the unit in use.
To select a different template screen, choose one from the
list. Alternatively, right-click anywhere on-screen in an
opened template and choose one from the list.
9.4Unit Status Windows
The Unit St atus windows at the top of ea ch scr ee n d isp lay infor matio n abou t th e status of the
unit.
The Unit Status window on a system setup screen shows the IP address of the unit, the
reference status, and the software version.
The Unit Status window on a channel operation screen shows the input, output, and audio
status of the channel.
The audio information line (shown here as Analog 2 PCM) cycles through the audio input
sources every few seconds, showing the status of each one in turn.
The audio status display information is as follows:
•PCM: Audio is PCM
•Mute: Audio is muted
•Tone: Audio is a test tone
•DolbyE: Audio is Dolby
•Loss: Audio is unavailable or invalid
The Unit Sta tus information is also present on the System screen and the Home screen on
the front panel.
In addition to the front panel and the RollCall Control Panel, the web applet enables you to
control the MC500 unit from a web browser. The appearance and controls are the same as
the RollCall Control Panel.
For information about the RollCall Control Panel template screens and controls, see “RollCall
Control Panel System Setup Screens” on page 87 and “RollCall Control Panel Channel
Operation Screens” on page 102.
To use the web applet you must have Java installed on your PC.
To start the web applet:
1.Enter the IP address of the unit into your web browser and press Enter.
The Kudos Configuration screen appears.
2.Click the Control Applet icon.
After a few moments the template screen appears.
You can now use the web applet to control the unit as detailed at the start of this
section.
This section details all of the screens, menu lists, options, and controls available for setting up
the unit from the RollCall Control Panel.
The screens shown in this section are for guidance and reference only, and may be slightly
different to those on your unit.
10.1Genlock
The Genlock screen provides controls that lock the output video clock to the genlock source
(input or reference) regardless of the video standard. If the genlock source and the video
output are the same frame rate, for example, 50 Hz or 59.94 Hz, Genlock locks the output to
the vertical phase of the genlock source, giving consistent and repeatable delay.
Lock to input wherever possible. Only lock to an external reference if necessary.
When attempting to pass non-PCM audio, ensure that Genlock is enabled. If using an
external reference, it must be clock-locked to the input video.
If Genlock is set to Free Run, non-PCM audio will always be corrupt.
10.1.1 Source
The Source menu enables you to select options for a genlock source.
•Ref Lock: Locks the output video to the incoming reference.
•Ch 1 Input: Locks the output video to the channel 1 input.
•Free Run: Output video is locked to an internal reference clock.
10.1.2 Current Reference Standard
Current Reference Standard displays the standard of the reference signal. If reference has
been assigned using the controls but an input signal is not detected on the assigned
reference input, Current Reference Standard shows “Invalid input”.
The Timing controls enable you to specify the horizontal and vertical genlock timing.
•Vertical Timing: Adjusts the vertical timing of the output signal with respect to the
reference signal. The adjustment range is one output line in one-line steps. The
preset value is 0.
•Horizontal Timing: Adjusts the horizontal timing of the output signal with respect to
the reference signal. The adjustment range is one output frame in one-pixel steps.
The preset value is 0.
•Status: Shows the status of the currently assigned referen ce. For example, if genlo ck
is assigned to input 1, Status shows “Ch 1 Input” followed by the current status of the
input. If there is no signal on the assigned reference, Status shows “REF Loss”.
The CVBS screen enables you to set up and view options for a video input source and the
video output signal. CVBS provides options for the two composite video input/output slots (if
the CVBS option is fitted).
Composite encoding and decoding options will have been chosen at the time of product
purchase. Y/C decoding is also available.
10.4.1 CVBS Decoder
Each slot has two composite video connections.
•Source: Use to select a video input source. If using a composite source, only one of
the two CVBS connectors are used.
•Input 1: Connection A1 contains the input composite signal.
•Input 2: Connection A2 contains the input composite signal.
•Y/C: When using Y/C signals both composite connectors are used, so this option
must be selected.
•ACC: The Automatic Chroma Control (ACC) examines the input burst amplitude and
adjusts chrominance gain to compensate for chroma level attenuation.
Note: Use this control when chroma levels are low compared to luminance. This may
occur when using YC installations or composite from RF links.
•CTI: The Chroma Transient Improver (CTI) examines the input video data. CTI
detects transitions of chroma and enhances chroma edges in order to artificially
restore lost color bandwidth.
Note: Use this control when the input video has chroma bandwidth limitations.
•Pedestal: When turned on, allows the composite source (NTSC only) to be treated as
if a pedestal is present.
•NTSC Hue: Adjusts the NTSC hue to correct tonal color changes.
The unit automatically detects the input standard.
The Dolby screen enables you to set up the how the unit handles Dolby audio. The MC500
unit supports Dolby D and E decoding as well as Dolby E transcoding when frame rate
converting. Dolby E encoding from a PCM input is not supported.
The Dolby encoder acts in tandem with the Dolby decoder: Dolby transcoding from one
frame rate to another is enabled. It is not possible to author Dolby audio from a PCM input.
x
Dolby transcoding means that a change to the Dolby frame rate is enabled, but a change to
the Dolby program format is not possible. For example, if the incoming video is at 50 Hz with
5.1+2 Dolby audio, when the MC500 is set to standards convert the video to 59 Hz, the Dolby
transcode function enables you to create 5.1+2 Dolby audio at 59 Hz. The output Dolby fr ame
rate follows the output video frame rate chosen for the processing channel.
For more information about the Dolby decoder and transcoder, see the KudosPro Dolby
Each Dolby slot houses a Dolby encoder and transcoder.
If the Dolby option is not fitted, the Dolby menus are grayed out.
•Decoder Source: Enables you to route the chosen incoming audio source (SDI or
AES) to the Dolby decoder. See “Block Diagrams” on page 15.
•Metadata Source: Enables you to choose whether to use the incoming Dolby
metadata when transcoding. Select the Decoder radio button to enable the metadata
or the None radio button to discard it.
•Dolby Delay Compensation: Enables you to select delay compensation to maintain
correct alignment.
•SMPTE 2020 Output: Selects the output line on which to insert a SMPTE 2020
VANC packet if Output Enable is selected. The range is from line 8 to line 20 in
one-line steps.
It is possible to set a forced association in the SMPTE 2020 metadata which sets the
Secondary Data ID (SDID) values used to identify the VANC packets to 45/02 (pair 1).
To use this control, enable “SDID Pair 1 Forced Assoc” from the Dolby menu under
the sub-menu SMPTE 2020 Output. When enabled, the outgoing 2020 data will be
labelled 45/02 (pair 1).
•Packet Type: Selects a method of data mapping for output SMPTE 2020 VANC
packets.
•A: SMPTE 2020-2-2008.
•B: SMTE 2020-3-2008.
•Input Status: Shows the status of the Dolby encoders and if the Dolby is valid.
•Decoder Rate: Shows the frame rate of the incoming Dolby audio (50 Hz or 59 Hz).
•Decoder Format: Shows the current decoder format. For example, in the case of
Dolby E, this could be 5.1+2, 7.1, 8x1 etc.
•Decoder Version: Shows the version number of the Dolby decoder. The Dolby E
decoder and encoder both have their own software ver sion installed which is
independent from the rest of the unit. Dolby updates this software continually.
•Encoder Version: Shows the version number of the Dolby encoder. The Dolby E
decoder and encoder both have their own software ver sion installed which is
independent from the rest of the unit. Dolby updates this software continually.
•Dolby Metadata Ou tpu t Line Status: Shows the actual output line number on which
the SMPTE 2020 VANC packet is embedded, as set on the SMPTE 2020 Output
slider. If no line number is selected, “OFF” is displayed.
Note: If the line selected is already in use (by VITC, for example), the VANC
embedding hierarchy will embed the SMPTE 2020 packet on the nearest available
line.
The Network screen provides access to the unit’s network details and setup.
10.6.1 Ethernet
The Ethernet controls enable you to view and set up all information relating to the unit’s
network connections.
•IP Configuration Status: Shows the current IP configuration.
•Current IP Address: Shows the current IP address.
•Current IP Gateway: Shows the current IP gateway.
•Current IP Netmask: Shows the current IP netmask.
•IP Configuration: Enables you to specify whether the unit is to use a DHCP or a
static IP address. See “Setting a Static IP Address” on page 96 and “Setting a DHCP
IP address” on page 96.
•IP Address: Enables you to enter an IP address.
•IP Gateway: Enables you to enter a gateway address.
•IP Netmask: Enables you to enter a netmask address.
•Interface Status: Shows the status of the Ethernet connection.
Note: If status is shows “down”, it means that no Ethernet connection is detected.
•Apply IP Changes: Applies any changes you make in the Ethernet menu.
To set a static IP address, you will need to enter all the following information: IP address,
IP gateway (even if you are not using an IP gateway), and IP netmask.
In the following example, we are setting a static IP address of 192.168.1.42.
To set a static IP address:
1.From the System Menu, select Network.
2.Under IP Configuration, select Fixed Address.
3.In the IP Address box, enter 192.168.1.42 and then click S.
4.In the IP Gateway box, enter 192.168.1.12 and then click S.
5.In the IP Netmask box, enter 255.255.255.0 and then click S.
Note: To return any box to its default value, click P.
6.When all addresses are set, you must apply the changes. To do this:
•Click Apply IP Changes.
The system updates and saves the changes made in the Ethernet menu.
You must disconnect the unit from your Local Area Network before setting a static IP
address to avoid IP conflicts on the network.
If the combination of IP address, IP gateway, and IP netmask in invalid, the system will not
update the IP address.
10.6.1.2 Setting a DHCP IP address
1.From the System Menu, select Network.
2.Under Ethernet > IP Configuration, select DHCP.
3.Click Apply IP Changes.
If you make any changes to the settings in the Ethernet menu, you must click Apply IP
Changes to confirm the changes.
10.6.2 RollCall
The RollCall controls enables you to view and set up the unit’s RollCall attributes for use
remotely with the RollCall Control Panel.
To change the name of the unit:
1.In the Change Name field, type a new name for the unit.
2.To save the memory name, click S. To return the memory to its default value, click P.
The Memories screen e nables you to save up to eight system- level memory setup s and recall
them when required.
You can change the default memory names to more relevant ones if required.
Memories set at a system level store all system settings except for the following:
•Network > DHCP
•Network > IP Configuration
•Network > IP Gateway
•Network > IP Netmask
•RollCall > Unit Name
Settings stored in the system memories include:
•CVBS encoder or decoder settings (if fitted)
•Dolby option settings (if fitted)
•Genlock selection and adjustment
•AES and analog audio routing
•CVBS calibration
System memories do not store any processing channel data.
10.8.1 Creating and Saving Memories
1.In the Memory Select column, choose a memory.
2.In the Change Name field, type a new name for the memory.
3.To save the memory name, click S. To return the memory to its default value, click P.
4.To save the memory, click Save Memory.
The new memory name appears in the Memory Select column.
The Recall Memory button recalls the settings saved in a memory location.
To recall a memory:
1.In the Memory Select column, choose a memory you want to recall.
2.Click Recall Memory.
The recalled settings are applied.
10.8.3 Reset to Defaults
The Reset to Defaults button recalls the unit’s default memory settings at both system and
channel level. All controls are reset to their preset values except for the following:
•Network > DHCP
•Network > IP Configuration
•Network > IP Gateway
•Network > IP Netmask
•RollCall > Unit Name.
Reset to defaults does not affect user memories.
10.8.4 Factory Reset
Factory Reset clears all user memories. Make a note of any important settings before
performing a factory rest.
Factory Reset recalls the unit’s default memory settings at both system and channel le vel. All
controls and user memories are reset to their preset values.
The default settings for IP Configuration is to set the unit to DHCP. Any saved settings for IP
Address, IP Netmask, and IP Gateway are also lost when performing a factory reset. The unit
returns all three to their default settings, which are as follows:
•IP Configuration: DHCP
•IP Address: 192.168.151.1
•IP Netmask: 255.255.255.0
•IP Gateway: 192.168.151.200
10.8.4.1 Performing a Factory Reset
1.From the System menu, select Memories > Factory Reset.
2.Do one of the following to apply the changes:
•From the Network screen, click Apply IP Changes.
•Reboot the system.
If performing a factory reset via a remote link, when you press Apply IP Changes, the
remote link will be lost.