Snell Advanced Media IQSDA42, IQSDA41 User Manual

Page 1
www.s-a-m.com
User Manual
IQSDA41
Single/Dual-Channel 12G/3G/HD/SD-SDI Re-clocking Distribution Amplifier with RollCall
IQSDA42
Multi-Channel 12G/3G/HD/SD-SDI Re-clocking Distribution Amplifier with RollCall
Page 2
IQSDA41/42 Information and Notices
Issue 1 Rev 1 Page 2 © 2017 SAM
Information and Notices
Copyright and Disclaimer
Copyright protection claimed includes all forms and matters of copyrightable materia l and information now allowed by statutory or judicial law or hereinafter granted, including without limitation, material generated from the software programs which are displayed on the screen such as icons, screen display looks etc.
Information in this manual and software are subject to change without notice and does not represent a commitment on the part of SAM. The software described in this manual is furnished under a license agreement and can not be reproduced or copied in any manner without prior agreement with SAM or their authorized agents.
Reproduction or disassembly of embedded computer programs or algorithms prohibited. No part of this publication can be transmitted or reproduced in any form or by any means,
electronic or mechanical, including photocopy, recording or any information storage and retrieval system, without permission being granted, in writing, by the publishers or their authorized agents.
SAM operates a policy of continuous improvement and development. SAM reserves th e ri ght to make changes and improvements to any of the products described in this document without prior notice.
Contact Details
Customer Support
For details of our Regional Customer Support Offices please visit the SAM website and navigate to Support/24/7-Support.
www.s-a-m.com/support/247-support/
Customers with a support contract should call their personalize d number, which can b e found in their contract, and be ready to provide their contract number and details.
Page 3
IQSDA41/42 Safety Information
Issue 1 Rev 1 Page 3 © 2017 SAM
Safety Information
Erklärung der Sicherheitssymbole
Dieses Symbol weist den Benutzer auf wichtige Informationen hin, die in der begleitenden Dokumentation enthalten sind.
Dieses Symbol zeigt an, dass gefährliche Spannung vorhanden ist. Es befinden sich keine vom Benutzer zu wartenden Teile im Geräteinneren. Dieses Gerät sollte nur von geschultem Personal gewartet werden
· Um das Risiko eines Elektroschocks zu reduzieren, setzen Sie das
Gerät weder Regen noch Feuchtigkeit aus.
· Stellen Sie immer sicher, dass das Gerät ordnungsgemäß geerdet und verkabelt ist.
· Dieses Equipment muss an eine Netzsteckdose mit Schutzleiter angeschlossen werden und einen zuverlässig id entifizierbaren Nullleiter haben.
· Die Netzsteckdose sollte nahe beim Gerät und einfach zugänglich sein.
Netzanschluss in anderen Ländern als der USA
Das Equipment wird im Normalfall mit einem Netzkabel mit Standard IEC Anschlussbuchse und einem Standard IEC Anschlussstecker geliefert. Sollten Sie den angeschweißten Stecker auswechseln müssen, entsorgen Sie diesen bitte umgehend. Die farbliche Belegung des Netzkabels ist wie folgt:
GRÜN GELB E = Schutzleiter BLAU N = Nulleiter BRAUN L = P = Phase
Achtung: Wenn das Gerät zwei Anschlussbuchsen hat, stellen Sie bitte sicher, dass beide Netzkabel mit der selben Phase in die Netzsteckdose gesteckt werden.
Sicherheits-Warnhinweise
D
!
!
Die angeführten Service-/Reparatur-Anweisungen sind ausschließlich von qualifiziertem Service-Personal auszuführen. Um das Risiko eines lektroschocks zu reduzieren, führen Sie ausschließlich die im Benutzerhandbuch eschriebenen Anweisungen aus, es sei denn, Sie haben die entsprechende Qualifikation. Wenden Sie sich in allen Service-Fragen an qualifiziertes Personal.
!
ACHTUNG
Gefahr von Elektrosc hocks.
Abde ckunge n nicht entfernen
Keine vom Benutzer zu wa rtende Teile
Wenden Sie sich ausschließlich
an qualifi zi ertesPersonal
L=
PhaseN=NulleiterN=NulleiterL=Phase
E=
Schutzleiter
E=
Schutzleiter
Explicación de los Símbolos de Seguridad
Éste símbolo refiere al usuario información importante contenida en la literatura incluida. Referirse al manual.
Éste símbolo indica que voltajes peligrosos están presentes en el interior. No hay elementos accesibles al usuario dentro. Esta unidad sólo debería ser tratada por personal cualificado.
Las instrucciones de servicio cuando sean dadas, son sólo para uso de personal cualificado. Para reducir el riesgo de choque eléctrico no llevar a cabo ninguna operación de servicio aparte de las contenidas en las instrucciones de operación, a menos que se esté cualificado para realizarlas. Referir todo el trabajo de servicio a personal cualificado.
· Para reducir el riesgo de choque eléctrico, no exponer este equipo
a la lluvia o humedad.
· Siempre asegurarse de que la unidad está propiamente conectada a tierra y que las conexiones de alimentación están hechas correctamente.
· Este equipo debe ser alimentado desde un sistema de alimentación con conexión a TIERRA y teniendo una conexión neutra fácilmente identificable.
·
La toma de alimentación para la unidad debe ser cercana y fácilmente
accesible.
Conexión de alimentación en otros p aíses que no sean USA
El equipo es normalmente entregado con un cable de alimentación con un enchufe hembra estándar IEC en un extremo y con una clavija estándar IEC en el otro. Si se requiere eliminar la clavija para sustituirla por otra, disponer dicha clavija de una forma segura. El código de color a emplear es como sigue:
Advertencia Si la unidad tuviera dos tomas de alimentación, asegurarse de que ambos cables de alimentación están conectados a la misma fase.
ESP
!
!
Advertencias de Seguridad
LNENL
E
Clavija
Aerea Macho
Enchufe
Aereo Hembra
VERDE/ AMARILLO conectado a E (Conductor de protección a Tierra
-Earth en el original-) AZUL conectado a N (Conductor Neutro -Neutral en el original-) MARRÓN conectado a L (Conductor Fase -Live en el original-)
RIESGO DE CHOQUE ELECTRICO NO QUITAR LAS PROTECCIONNES ELEMENTOS NO ACCESIBLES AL USUARIO. SERVICIO SOLAMENTE A PERSONAL CUALIFICADO
Page 4
IQSDA41/42 Safety Information
Issue 1 Rev 1 Page 4 © 2017 SAM
Simboli di sicurezza:
Questo simbolo indica l'informazione importante contenuta nei manuali appartenenti all'apparecchiatura. Consultare il manuale.
Questo simbolo indica che all'interno dell'apparato sono presenti tensioni pericolose. Non cercare di smontare l'unità. Per qualsiasi tipo di intervento rivolgersi al personale qualificato.
Le istruzioni relative alla manutenzione sono ad uso esclusivo del personale qualificato. E' proibito all'utente eseguire qualsiasi operazione non esplicitamente consentita nelle istruzioni. Per qualsiasi informazione rivolgersi al personale qualificato.
· Per prevenire il pericolo di scosse elettriche è necessario non esporre
mai l'apparecchiatura alla pioggia o a qualsiasi tipo di umidità.
· Assicurarsi sempre, che l'unità sia propriamente messa a terra e che le connessioni elettriche siano eseguite correttamente.
· Questo dispositivo deve essere collegato ad un impianto elettrico dotato di un sistema di messa a terra efficace.
· La presa di corrente deve essere vicina all'apparecchio e facilmente accessibile.
Connessione elettrica nei paesi diversi dagli Stati Uniti
L'apparecchiatura normalmente è spedita con cavo pressofuso con la presa e spina standard IEC. Nel caso della rimozione della spina elettrica, gettarla via immediatamente osservando tutte le precauzioni del caso. La leggenda dei cavi è la seguente:
VERDE/GIALLO cavo connesso ad "E" (terra) BLU cavo connesso ad "N" (neutro) MARRONE cavo connesso ad "L" ( fase)
Attenzione! Nel caso in cui l'apparecchio abbia due prese di corrente, assicurarsi che i cavi non siano collegati a fasi diverse della rete elettrica.
I
!
!
Attenzione:
!
ATTENZIONE
LNENL
E
Presa volante Spina volante
RISCHIO DI SHOCK ELETTRICO
NON CERCARE DI SMONTARE
L'UNITA PER QUALSIASI TIPO DI
INTERVENTO RIVOLGERSI AL
PERSONALE QUALIFICATO
Forklaring på sikkerhedssymboler
Dette symbol gør brugeren opmærksom på vigtig information i den medfølgende manual.
Dette symbol indikerer farlig spænding inden i apparatet. Ingen bruger servicerbare dele i apparatet på brugerniveau. Dette apparat må kun serviceres af faglærte personer..
Serviceinstruktioner er kun til brug for faglærte servicefolk. For at reducere risikoen for elektrisk stød må bruger kun udføre anvisninger i betjeningsmanualen. Al service skal udføres af faglærte personer.
· For at reducere risikoen for elektrisk stød må apparatet ikke
udsættes for regn eller fugt.
· Sørg altid for at apparatet er korrekt tilsluttet og jordet.
· Dette apparat skal forbindes til en nettilslutning, der yder
BESKYTTENDE JORD og 0 forbindelse skal være tydeligt markeret.
· Stikkontakten, som forsyner apparatet, skal være tæt på apparatet og let tilgængelig
.
Nettilslutning i andre lande end USA
Udstyret leveres normalt med et strømkabel med et standard IEC støbt løst hunstik i den ene ende og et standard IEC støbt hanstik i den anden ende. Hvis et af de støbte stik på strømkablet er defekt, skal det straks kasseres på forsvarlig vis. Farvekoden for lederen er som følger:
GRØN/GUL leder forbundet til J (Jord) BLÅ leder forbundet til 0 BRUN leder forbundet til F(Fase)
Forsigtig Hvis enheden har to lysnetindgange, skal der sørges for at begge ledninger tilsluttes lystnetudgange fra den samme fase.
DK
!
!
!
Sikkerhedsadvarsler
!
FORSIGTIG
RISIKO FOR ELEKTRISK STØ D DÆKPLADERMÅ IKKEFJERNES INGEN BRUGER SERVICERBARE
DELE SERVI CE M Å KUN UDFØRES
AF FAGLÆRTE PERSONER
F0J0F
J
Han-stik Hun-stik
Förklaring av Säkerhetssymboler
Denna symbol hänvisar användaren till viktig information som återfinns i litteraturen som medföljer. Se manualen.
Denna symbol indikerar att livsfarlig spänning finns på insidan. Det finns inga servicevänliga delar inne i apparaten. Denna apparat få endast repareras av utbildad personal.
Serviceinstruktioner som anges avser endast kvalificerad och utbildad servicepersonal. För att minska risken för elektrisk stöt, utför ingen annan service än den som återfinns i medföljande drifti nstrukti onerna, om du e j ä r behörig. Överlåt all service till kvalificerad personal.
· För att reducera risken för elektrisk stöt, utsätt inte apparaten för
regn eller fukt.
· Se alltid till att apparaten är ordentligt jordad samt att strömtillförseln är korrekt utförd.
· Denna apparat måste bli försörjd från ett strömsystem som är försedd med jordadanslutning samt ha en neutral anslutning som lätt identifierbar.
· Vägguttaget som strömförsörjer apparaten bör finnas i närheten samt vara lätttillgänglig.
Strömkontakter i länder utanför USA
Apparaten utrustas normalt med en strömkabel med standard IEC gjuten honkontakt på ena änden samt en standard IEC gjuten hankontakt på den andra änden. Om man måste avlägsna den gjutna hankontkaten, avyttra denna kontakt omedelbart på ett säkert sätt. Färgkoden för ledningen är följande:
GRÖN/GUL ledning ansluten till E
(Skyddsjordad ledare)
BLÅ ledning ansluten till N (Neutral ledare)
BRUN ledning ansluten till L (Fas ledare)
Varning! Om enheten har två huvudsakliga elförsörjningar, säk erställ att båda strömkablarna som är inkopplade i enheten arbetar från samma fas.
S
!
CAUTION
RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS
NO USER SERVICEABLE PARTS
REFER SERVICING TO QUALIFIED
PERSONNEL ONLY
!
!
Säkerhetsvarningar
LNENL
E
Stickkontakt-Hane Stickkontakt-Hona
Turvamerkkien selitys
Tämä merkki tarkoittaa, että laitteen mukana toimitettu kirjallinen materiaali sisältää tärkeitä tietoja. Lue käyttöohje.
Tämä merkki ilmoittaa, että laitteen sisällä on vaarallisen voimakas jännite. Sisäpuolella ei ole mitään osia, joita käyttäjä voisi itse huoltaa. Huollon saa suorittaa vain alan ammattilainen.
Huolto-ohjeet on tarkoitettu ainoastaan alan ammattilaisille. Älä suorita laitteelle muita toimenpiteitä, kuin mitä käyttöohjeissa on neuvottu, ellet ole asiantuntija. Voit saada sähköiskun. Jätä kaikki huoltotoimet ammattilaiselle.
· Sähköiskujen välttämiseksi suojaa laite sateelta ja kosteudelta.
· Varmistu, että laite on asianmukaisesti maadoitettu ja että
sähkökytkennät on tehty oikein.
· Laitteelle tehoa syöttävässä järjestelmässä tulee olla SUOJAMAALIITÄNTÄ ja nollaliitännän on oltava luotettavasti tunnistettavissa.
· Sähköpistorasian tulee olla laitteen lähellä ja helposti tavoitettavissa.
Sähkökytkentä
Laitteen vakiovarusteena on sähköjohto, jonka toisessa päässä on muottiin valettu, IEC-standardin mukainen liitäntärasia ja toisessa päässä muottiin valettu, IEC-standardin mukainen pistoliitin. Jos pistoliitin tarvitsee poistaa, se tulee hävittää heti turvallisella tavalla. Johtimet kytketään seuraavasti:
KELTA-VIHREÄ suojamaajohdin E-napaan SININEN nollajohdin N-napaan RUSKEA vaihejohdin L-napaan
Huom! Jos laitteessa on kaksi verkkojännitteen tuloliitäntää, niiden johdot on liitettävä verkkopistorasioihin, joissa on sama vaiheistus.
FI
!
!
Turvaohjeita
!
SÄHKÖISKUN VAARA ÄLÄ AVAA
LAITTEEN KANSI A EI SISÄLLÄ
KÄYTTÄJÄLLE H UOLLETTAVI A
OSIAHUOLTOAINOASTAAN
AMMATTILAISEN SU ORITTAM ANA
VAROITUS
LNENL
E
Pistoliitin Liitäntärasia
Page 5
IQSDA41/42 Safety Information
Issue 1 Rev 1 Page 5 © 2017 SAM
Laser Safety
This product operates with Class 1 laser products.
Ventilation
Although the unit is constructed to meet normal environmental requirements, ensure that there is a free flow of air at the front, rear, and sides of the unit to dissipate the heat produced during operation. Installations should be designed to allow for this.
Safety Standards
This equipment conforms to the following standards:
EN60950-1 2006
Safety of Information T echnology Equi pment Including Electrical Business Equipment.
UL1419 (3rd Edition) - UL File E193966 Standard for Safety – Professional Video and Audio equipment.
Símbolos de Segurança
O símbolo triangular adverte para a necessidade de consultar o manual antes de utilizar o equipamento ou efectuar qualquer ajuste.
Este símbolo indica a presença de voltagens perigosas no interior do equipamento. As peças ou partes existentes no interior do equipamento não necessitam de intervenção, manutenção ou manuseamento por parte do utilizador. Reparações ou outras intervenções devem ser efectuadas apenas por técnicos devidamente habilitados.
As instruções de manutenção fornecidas são para utilização de técnicos qualificados. Para reduzir o risco de choque eléctrico, não devem ser realizadas intervenções no equipamento não especificadas no manual de instalações a menos que seja efectuadas por técnicos habilitados.
· Para reduzir o risco de choque eléctrico, não expor este equipamento
à chuva ou humidade.
· Assegurar que a unidade está sempre devidamente ligada à terra e que as ligações à alimentação estão correctas.
· O sistema de alimentação do equipamento deve, por razões de segurança, possuir ligação a terra de protecção e ligação ao NEUTRO devidamente identificada.
· A tomada de energia à qual a unidade está ligada deve situar-se na sua proximidade e facilmente acessível.
Ligação da alimentação noutros países que não os EUA
O equipamento é, normalmente, enviado com cabo de alimentação com ficha IEC fêmea standard num extremo e uma ficha IEC macho standard no extremo oposto. Se for necessário substituir ou alterar alguma destas fichas, deverá remove-la e elimina-la imediatamente de maneira segura. O código de cor para os condutores é o seguinte:
Condutor VERDE/AMARELO ligado a E (Terra) Condutor AZUL ligado a N (Neutro) Condutor CASTANHO ligado a L (Vivo).
Atenção: Se a unidade tem duas fontes de alimentação assegurar que os dois cabos de alimentação estão ligados a tomadas pertencentes à mesma fase .
P
!
!
Avisos de Segurança
LNENL
E
Ficha Livre TomadaLivre
!
CAUTION
RISK OF ELEC TRIC SHOC K DO NOT REMOVE COVERS
NO USER SERVIC EABLE PARTS
REFER SERVICING TO QUALIFIED
PERSONNEL O N LY
Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Do not obstruct the ventilation holes on the right-side of the unit. Dam age to the equipment may result.
Page 6
IQSDA41/42 Safety Information
Issue 1 Rev 1 Page 6 © 2017 SAM
EMC Standards
This equipment conforms to the following standards:
EN 55032:2012 (Class A)
Electromagnetic Compatibility of Multimedia Equipment - Emission Requirements.
EN 61000-3-2:2014 (Class A)
Limits for Harmonic Current Emissions.
EN 61000-3-3:2013
Limitation of V oltage Cha nges, Voltage Fluctuations and Flicker in Pu blic Low-Voltage Supply Systems.
FCC/CFR 47:Part 15, Class A
Federal Communications Commission Rules Part 15, Subpart B, Class A.
EMC Environment
The product(s) described in this manual conform to the EMC requirements for, and are intended for use in, the controlled EMC environment (for example, purpose-b uilt broadcasting or recording studios), and the rural outdoor enviro nment (far away from railways, transmitter s, overhead power lines, etc.) E4.
EMC Performance of Cables and Connectors
SAM products are designed to meet or exceed the req uirement s of the appro priate Europe an EMC standards. In order to achieve this performance in real installations it is essential to use cables and connectors with good EMC characteristics.
All signal connections (including remote control connections) shall be made with screened cables terminated in connectors having a metal shell. The cable screen shall have a large-area contact with the metal shell.
Coaxial Cables
Coaxial cables connections (particularly serial digital video connections) shall be made with high-quality double-screened coaxial cables such as Belden 1694 or BBC type PSF1/2M.
D-type Connectors
D-type connectors shall have metal shells making good RF contact with the cable screen. Connectors having indents which improve contact between the p lug and socket shells are recommended.
Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.
Page 7
IQSDA41/42
Issue 1 Rev 1 Page 7 © 2017 SAM
Contents
Information and Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1.1 IQSDA41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1.2 IQSDA42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.2 Order Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.3 Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.3.1 B-style Enclosures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2 Technical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
3 Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1 SDI Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1.1 Bi-directional Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4 Rear Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5 Operation Using the RollCall Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.1 Navigating Pages in the RollCall Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.1.1 Setting Values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.1.2 Template Pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.2 Information Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.3 Input Output Page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.3.1 Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.3.2 Inputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.3.3 Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.4 Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.4.1 Default Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.4.2 Factory Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.4.3 Restart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.4.4 Input Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
5.5 Logging - Misc. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5.6 Logging - Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.7 Logging - Output 1-n . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
5.8 RollTrack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.8.1 Disable All . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.8.2 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.8.3 Source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.8.4 Address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.8.5 Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.8.6 RollTrack Sending . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.8.7 RollTrack Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.9 Memory 1-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.9.1 Recall Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.9.2 Save Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.9.3 Last Recalled Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.9.4 Save Memory Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Page 8
IQSDA41/42 Introduction
Issue 1 Rev 1 Page 8 © 2017 SAM
1 Introduction
1.1 Description
1.1.1 IQSDA41
The IQSDA41 is a single- or dual- channel SDI distribution amplifier for UHD-1 12 Gbit/s, HD 3 Gbit/s, 1.5 Gbit/s or SD 270 Mbit/s signals, providing up to 9 equalized and reclocked outputs in a single-width package. Its 60m 12G, 80m 3G, 180m HD input equalization performance and non-reclocking distribution of wide-band signals make it ideal for all distribution applications.
1.1.1.1 Block Diagram
1.1.1.2 Feature Summary
The IQSDA41 provides the following features:
Intelligent UHD-1 12 Gbit/s, HD 3 Gbit/s or 1.5 Gbit/s and SD-SDI re-clocking distribution amplifier.
Configurable as 1 input to 9 outputs, or 2 inputs with 4 outputs per input, or 4 inputs with 4 outputs per input.
Equalizes up to 60m at 12 Gbit/s, 80m at 3 Gbit/s, 180m at 1.5 Gbit/s, and more than 350m at 270 Mbit/s when using Belden 1694A cable.
Standards supported:
3G-HD to SMPTE 424M
HD-SDI to SMPTE 292M
SD-SDI to SMPTE 259M-C
DVB-ASI
1310nm, 1550nm, and CWDM output wavelengths available.
RollCall monitoring allows all signal paths to be managed.
Page 9
IQSDA41/42 Introduction
Issue 1 Rev 1 Page 9 © 2017 SAM
1.1.2 IQSDA42
The IQSDA42 is a configurable single, dual or quad-channel SDI distribution amplifier for UHD-1 12 Gbit/s, HD 3 Gbit/s, 1.5 Gbit/s or SD 270 Mbit/s signals, providing up to 19 equalized and re-clocked outputs of the input in a single wid th-package. Its 60m 12G, 80m 3G, 180m HD input equalization performance coupled with excellent packing density make it ideal for signal-dense distribution applications.
1.1.2.1 Block Diagram
1.1.2.2 Feature Summary
The IQSDA42 provides the following features:
Intelligent UHD-1 12 Gbit/s, HD 3 Gbit/s or 1.5 Gbit/s and SD-SDI re-clocking distribution amplifier.
Configurable as 1 input to 19 outputs, or 2 inputs with 9 outputs per input, or 4 inputs with 4 outputs per input.
Equalizes up to 60m at 12 Gbit/s, 80m at 3 Gbit/s, 180m at 1.5 Gbit/s and more than 350m at 270 Mbit/s when using Belden 1694A cable.
Page 10
IQSDA41/42 Introduction
Issue 1 Rev 1 Page 10 © 2017 SAM
Standards supported:
12G UHD-1 to SMPTE 2082
3G-HD to SMPTE424M
HD-SDI to SMPTE292M
SD-SDI to SMPTE259M-C
DVB-ASI
RollCall monitoring allows all signal paths to be managed.
1.2 Order Codes
The following module order codes are covered by this manual:
IQSDA4100-1B4 12G/3G/HD/SD-SDI Re-clocking Distribution Amplifier. 1 input, 7 outputs
or 2 inputs 3 outputs per input, 2 optical inputs or 2 optical outputs.
IQSDA4101-1B4 12G/3G/HD/SD-SDI Re-clocking Distribution Amplifier. 1 input, 9 outputs
or 2 inputs 4 outputs per input.
IQSDA4200-1B4 Multi-channel 12G/3G/HD/SD-SDI Re-clocking Distribution Amplifier. 1
input, 15 outputs, 2 inputs 7 outputs per input or 4 inputs 3 outputs per input. 1 optical input and 1 optical output.
IQSDA4201-1B4 Multi-channel 12G/3G/HD/SD-SDI Re-clocking Distribution Amplifier. 1
input, 19 outputs, 2 inputs 9 outputs per input or 4 inputs 4 outputs per input.
Page 11
IQSDA41/42 Introduction
Issue 1 Rev 1 Page 11 © 2017 SAM
The following SFP modules are available for the IQSDA range:
1.3 Enclosures
The IQSDA4x modules can be fitted into the enclosure types below.
1.3.1 B-style Enclosures
1.3.1.1 IQH3B-S-0, IQH3B-S-P
1.3.1.2 IQH4B-S-P
FC1-13TR-12G Fiber transceiver, 1 x 12G Rx, 1 x 12G Tx (1310nm). FC1-13T2-12G Fiber transceiver 2 x 12G Tx (1310nm). FC1-13R2-12G Fiber transceiver 2 x 12G Rx.
Important:
Although IQ modules are interchangeable between enclosures, their rear panels are enclosure-specific. IQH3B and IQH4B enclosures accept modules with either A or B order codes. IQH3A or IQH1A enclosures accept modules with A order codes only.
Note:
The IQH3B and IQH4B enclosures provide two int er na l an alo g re fe re nc e inp uts. Thes e inputs are applicable to modules with B order codes only.
Page 12
IQSDA41/42 Technical Specification
Issue 1 Rev 1 Page 12 © 2017 SAM
2 Technical Specification
Inputs and Outputs Signal Inputs
SDI Inputs 1 or 2 (configurable) x 12G/3G/HD/SD-SD (IQSDA41)
1, 2 or 4 (configurable) x 12G/3G/HD/SD-SD (IQSDA42) Connector/Format HD-BNC/75 Ohm panel jack on standard SAM connector panel Input Cable Length Up to 60 m Belden 1694A @ 12 Gbit/s
Up to 80 m Belden 1694A @ 3 Gbit/s
Up to 180 m Belden 1694A @ 1.5 Gbit/s
350+ m Belden 1694A @ 270 Mbit/s
Note: When using mixed HD and SD inputs, it is recommended
that cable lengths do not exceed the HD specification of 180 m.
Signal Outputs
SDI Outputs Up to 19, group selectable Connector / Format HD-BNC/75 Ohm panel jack on standard SAM connector panel Conforms to video
standards
SMPTE 297-2006
SMPTE 424M (HD level A/B)
SMPTE 292M (HD)
SMPTE 259M-C (SD)
Control Interface
Electrical TTL compatible, active low driven Connector/Format HD-BNC/75 Ohm panel jack on standard SAM connector panel
Controls
Indicators: Power OK (Green) CPU OK (Green flashing) Input 1 OK (Green), Bypass (Orange), Loss (Red) Input 2 OK (Green), Bypass (Orange), Loss (Red) SFP A OK (Green), Bypass (Orange), Loss (Red) SFP B OK (Green), Bypass (Orange), Loss (Red)
Other Controls
User Memories Name, save, and recall 16 user memories Memory Naming User configurable naming of memories 1–16 Information Window Unit Status, SFP Status Logging Input 1(2) Type
Input 1 (2) Data Rate
Input 1 (2) Present
Input 1 (2) Error
Input 1 (2) Loss Optical Logging Tx Laser Bias High Warning
Tx Power Low Warning
Tx Power High Warning Laser Wavelength Input 1 (2) Rx Power High Warning
Input 1 (2) Rx Power Low Warning
Input 1 (2) Rx Power Measurement RollTrack Index Up to 16 RollTrack destinations RollTrack Controls On/Off, Index, Source, Address, Command, Status, Sending
Page 13
IQSDA41/42 Technical Specification
Issue 1 Rev 1 Page 13 © 2017 SAM
Roll Track Sources Unused, Input Present (1 & 2, Fiber 1 & 2), Input Loss (1 & 2,
Fiber 1 & 2), Output Rate/Std (1 & 2), Out 1 Selects (In 1 & 2 & Rx
1 & Rx 2), Fiber Rx Power OK (1 & 2), Fiber Rx Power Fail (1 & 2),
Fiber Tx Bias OK (1 & 2), Fiber Tx Bias High (1 & 2), Fiber Tx Bias
Low (1 & 2) (Note: fiber connections are not supported in this
release). Factory Default Resets all module settings to factory specified default values and
clears memories Default Settings Resets all module settings to factory specified default values but
does not clear memories Restart Software restart of the module Module Information Reports the following module information: Sof tware V ersion, Serial
Number, Build Number, KOS Version, Firmware Version, PCB
Version
Specifications
Electrical 3 Gbit/s SDI, SMPTE 424M
1.5 Gbit/s HD-SDI, SMPTE 292M
270 Mbit/s SDI, SMPTE 259M-C / DVB-ASI Connector/Format HD-BNC 75Ohm Return Loss >-15 dB (270 Mbit/s, 1.5 Gbit/s)
>-10 dB (3 Gbit/s) Output Jitter SD-SDI 0.2 UI (10 Hz) / 0.2 UI (1 kHz)
3G/HD-SDI 1.0 UI (10 Hz) / 0.2 UI (100 kHz)
Power Consumption
Module Power Consumption
5PR IQSDA41
8PR IQSDA42
Page 14
IQSDA41/42 Connections
Issue 1 Rev 1 Page 14 © 2017 SAM
3 Connections
This section describes the physical input and output connections provided by the IQSDA41/42 .
3.1.1 Bi-directional Connectors
Bi-directional connectors can be used as either an input or an output. They can be identified by the gray shading and the twin ID numbers; the number in white is the input number, and the number in black is the output number.
3.1 SDI Input/Output
Serial digital inputs and outputs are via
HD-BNC connectors which terminate in 75 Ohms. The number of connectors varies according to the actual module variant in use.
Connectors are color-coded for easy identification:
Black shading indicates an input; Gray shading indicates a bi-directional connector (see below); No shading indicates an output.
Page 15
IQSDA41/42 Rear Panel LEDs
Issue 1 Rev 1 Page 15 © 2017 SAM
4Rear Panel LEDs
The LEDs on the rear panel of the module indicate input status. There is one LED per input.
When Green: Input enabled, signal valid.
When Yellow: Input disabled or Reclocker Bypass active.
When Red: No signal on input or signal not valid.
See section 5.3 for information on enabling/disabling inputs.
Page 16
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 16 © 2017 SAM
5 Operation Using the RollCall Control Panel
This section contains information on using IQSDA41/42 modules with RollCall. For help with general use of the RollCall application, open the user manual by clicking
on the main RollCall toolbar.
5.1 Navigating Pages in the RollCall Template
The RollCall template has a number of pages, each of which can be selected from the drop-down list at the top left of the display area. Right-clicking anywhere on the pages will also open a page view list, allowing quick access to any of the pages.
5.1.1 Setting Values
Many of the settings within the templates have values, either alpha or numeric. When setting a value in a field, the value, whether text or a number, must be saved by
pressing the E
NTER key , or clicking the Save Value button.
Clicking an associated Preset Value button returns the value to the factory default setting.
5.1.2 Template Pages
The following pages are available:
Input Output - See section 5.3.
Setup - See section 5.4.
Logging - Misc - See section 5.5.
Logging - Input - See section 5.6.
Logging - Output 1-n - See section 5.7.
RollTrack - See section 5.8.
Memory 1-16 - See section 5.9.
Note:
The IQSDA4x will dynamically configure itself depending on rear and SFP options. The RollCall control panel will change to reflect the current product configuration.
The pages shown in this section are for guidance and reference only, and may be slightly different to those on your module.
Pages
drop-down
list
Page 17
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 17 © 2017 SAM
5.2 Information Window
The Information window is displayed at the top of each page, next to the pages list. It can displays basic information about the input and output status of the module; select a radio button as required.
Page 18
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 18 © 2017 SAM
5.3 Input Output Page
The Input Output pag e enables inputs and output s to be configured, and determines how the module behaves in the event of an input error.
5.3.1 Configuration
Use the radio buttons to select the input/output configuration. The options available are dependant on the particular module hardware configuration in use; the other controls on the page will also vary depending on the option selected.
5.3.2 Inputs
These controls are used to configure inputs; select the input rate(s) to be re-clocked. Re-clocking can be disabled on an output-by-output basis if required (see section 5.3.3), or globally by enabling Reclocker Bypass.
Rate Select: Enable check boxes to specify the rate(s) to which an input will be re-clocked. If check boxes are disabled, input signals at those rates will be muted.
Reclocker Bypass: Enable to prevent re-clocking on all input signals.
5.3.3 Outputs
Each output can be muted individually; select Mute to manually apply mute as required.
.
Note:
If an incoming signal contains errors or is otherwise invalid, it will be automatically muted.
Page 19
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 19 © 2017 SAM
5.4 Setup
The Setup page displays basic information about the module, such as the serial n umber a nd software versions. Use the functions on the p age to rest art the m odule or retur n all settings to their factory or default settings.
Product: Name of the module.
Software Version: Currently installed software version number.
Serial No: Module serial number.
Build: Factory build number. This numbe r identifies all parameters of the module.
OS: Operating system version number.
PCB: Printed Circuit Board revision number.
PCB Mods: PCB modification level.
5.4.1 Default Settings
The Default Settings button enables module settings to be reset to their factory defaults, leaving user memories intact.
5.4.2 Factory Defaults
The Factory Defaults button ena bles the mo du le settings to be re se t to their factory defaults.
5.4.3 Restart
Click Restart to power cycle the module.
Note:
Resetting the module to its factory defaults also clears all the saved memory settings.
Page 20
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 20 © 2017 SAM
5.4.4 Input Name
These are the input names displayed in logs. To change the name of Input 1 or Input 2, type the name in the text field and click S. T o return
the name to its factory default, click P.
Page 21
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 21 © 2017 SAM
5.5 Logging - Misc
The Logging - Misc page displays current log information regar ding the unit’s basic parameters.
The following options are available. Enable check boxes to activate logging.
Log Field Description
SN= Reports the module serial number, which consists of an S
followed by eight digits.
Note: this cannot be deselected. OS_VERSION= Reports the operating system name and version. BUILD_NUMBER= Reports the build number. HARDWARE_VERSION= Reports the hardware version number. HARDWARE_MOD= Reports the hardware modification number. ROL_STATES= Reports the RollCall status. Valid values are:
OK
FAIL:n where n is the RollTrack index or indices which are failing.
Disabled
LAST_RECALLED_MEMORY=Reports the last memory to be recalled.
SLOT_WIDTH= Reports the slot width. SLOT_START= Reports the slot start number. UPTIME= Reports the time since the last restart in the format
ddd:hh:mm:ss.
POWER_USAGE= Displays the power rating for the module. This is not a live
power reading, but rather a maximum rating . Note: this cannot be deselected.
Page 22
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 22 © 2017 SAM
5.6 Logging - Input
The Logging - Input page displays current input logging information.
The following options are available. Enable check boxes to activate log fields as required.
Where N is the input number
Log Field Description
INPUT_N_STATE= Reports current state of the input signal. Valid values are:
OK: input signal good.
FAIL: input signal not detected. INPUT_N_SDIRATE= Reports current bit rate for the input. INPUT_N_TYPE= Reports current input type. Valid values are:
•HD
•SD
•3G
•6G
•12G
•SDI
INPUT_N_IDENT= Reports system-defined identifier for the input, based on
the rear ID.
INPUT_N_NAME= Reports name of the input, as defined on the Setup p age;
see section 5.4.
Page 23
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 23 © 2017 SAM
5.7 Logging - Output 1-n
The Logging - Output 1-n pages display current logging information for each output.
The following options are available. Enable check boxes to activate log fields as required.
Where N is the input number
Log Field Description
OUTPUT_N_STATE= Valid values are:
•OK: output signal good.
•FAIL: output signal not detecte d .
WARN:Freeze
WARN:Pattern
WARN:Black
OUTPUT_N_SDIRATE= Reports current bit rate for the output. OUTPUT_N_TYPE= Valid values are:
•HD
•SD
•3G
•6G
•12G
•SDI
OUTPUT_N_IDENT= Name of the output as shown on the rear panel. OUTPUT_N_NAME= Reports name of the output, as defined on the Setup
page; see section 5.4.
Page 24
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 24 © 2017 SAM
5.8 RollTrack
The RollTrack page allows information to be sent, via the RollCall network, to other compatible units connected on the same network.
5.8.1 Disable All
When checked, all RollTrack items are disabled.
5.8.2 Index
This slider enables up to 16 RollTrack outputs to be set up. Dr agging the slider selects the RollTrack Index number, displayed below the slider. Clicking the P button selects the default preset value.
5.8.3 Source
This enables selection of the source of information which is to trigger the tr ansmission of data. Clicking the P button selects the default preset value. When no source is selected, Unused is displayed.
RollTrack Source Description
User Memory 1-16 User-defined. Unused No RollTracks sent. Input N OK Input N is good. Input N LOST Input N is bad. Input N Bitrate 12G Received bit rate is 12 Gbit/s. Input N Bitrate 6G Received bit rate is 6 Gbit/s. Input N Bitrate 3G Received bit rate is 3 Gbit/s. Input N Bitrate 1.5 Received bit rate is 1.5 Gbit/s. Input N Bitrate 270 Received bit rate is 270 Mbit/s. Input N Bitrate Un. Received bit rate is unknown. TX N Bias OK LASER Bias currently within limits.
Page 25
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 25 © 2017 SAM
Where N is the input number
5.8.4 Address
This item enables the address of the selected destination unit to be set. The address may be changed by typing the new destination in the text area and then
selecting the S button to save the selection. Clicking the P button returns to the default preset destination.
The RollTrack address consists of four sets of numbers, for example, 0000:10:01*99.
The first set (0000) is the network segment code number.
The second set (10) is the number identifying the (enclosure/mainframe) unit.
The third set (01) is the slot number in the unit.
The fourth set (99) is a user-defined unique identification number for the destination unit in a multi-unit system. This ensures that only the correct unit will respond to the command. If left at 00 an incorrectly fitted unit may respond unexpectedly.
5.8.5 Command
This item enables a command to be sent to the selected destination unit. The command may be changed by typing a code in the text area and then selecting the S
button to save the selection. Clicking the P button returns to the default preset command. The RollTrack command consists of two sets of numbers, for example: 84:156.
The first number (84) is the actual RollTrack command.
The second number (156) is the value sent with the RollTrack command.
5.8.6 RollT rack Se nding
A message is displayed here when the unit is actively sending a RollTrack command. Possible RollTrack Sending messages are:
5.8.7 RollT rack Status
A message is displayed here to indicate the status of the currently selected RollTrack index. Possible RollTrack Status messages are:
TX N Bias High LASER Bias currently above limits. TX N Bias Low LASER Bias currently below limits. RX N Power OK Receive power is within limits. RX N Power High Receive power is above limits. RX N Power Low Receive power is below limits.
RollTrack Source Description
Message Description
String A string value is always being sent. Number A number value is always being sent. No The message is not being sent. Yes The message is being sent. Internal Type Error Inconsistent behavior. Please contact your local SAM agent.
Page 26
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 26 © 2017 SAM
RollTrack Source Description
OK RollTrack message was sent and received successfully. Unknown RollTrack message has been sent but transmission has not
yet completed.
Timeout RollTrack message has been sent but no acknowledgement
received. This could be because the destination unit is not at the location specified.
Bad RollTrack message has not been correctly ackn owledged at
the destination unit. This could be because the destination unit is not of the type specified.
Disabled RollTrack sending is disabled.
Page 27
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 27 © 2017 SAM
5.9 Memory 1-16
The Memory 1-16 page enables up to 16 configurations to be saved and recalled later. Default memory names can be changed to provide more meaningful descriptions.
5.9.1 Recall Memory
This column lists the settings that have been previously saved. If no settings have been saved, None Selected is displayed.
To recall the settings saved in a memory:
In the Recall Memory column, select the memory to recall by clicking on it. The recalled settings will be applied and the memory name will appear in the Last
Recalled Memory section.
5.9.2 Save Memory
This column lists the 16 pre-set memory names that are available for use. To save settings:
In the Save Memory column, select a memory location, and then click Save. The current settings are saved and the memory appears in the Recall Memory column.
To clear a memory location:
In the Save Memory column, select a memory location, and then click Clear. The current settings stored for that memory are cleared. After you clear a memory location, it disappears from the Recall Memory list.
Note:
User memories do not recall log field “states” – that is, whether a log value has been enabled or disabled.
Page 28
IQSDA41/42 Operation Using the RollCall Control Panel
Issue 1 Rev 1 Page 28 © 2017 SAM
5.9.3 Last Recalled Memory
The Last Recalled Memory pane displays the most recently recalled memory. If any o f the settings have been changed since it was recalled, an asterisk will be displayed after the memory name.
5.9.4 Save Memory Name
This option enables the pre-set memory names to be changed to something more memorable or meaningful, if required.
To change a memory name:
In the Save Memory Name field, type the new memory name, and then click the S button. To return the memory to its default preset value, click P button.
Loading...