Smith's Heating First Space saver SS7, Space saver SS5, Space saver SS3, Space saver SS9 Installation And User Manual

Products with this symbol (crossed out wheelie b in) cannot be dispo sed as household waste. Old electrical and electronic equipment must be rec ycled at a facility capable of handling these products and t heir waste by-products. If you are purchasing replacement equipment your retailer may offer a 'take back' scheme, or will be able to give details of the nearest approved authorised treatment facility. Proper recycling and waste disposal will help conserve resources whilst preventing detrimen tal effec ts on our health and the environment.
WEEE Registered Code: WEE/ED0093VW
This appliance is not intended for use by persons (including children) with reduced ph ysical, sensory or mental capabilities, or lack of experience and knowledge, unless they have be en given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Approved CQS ISO 9000:2008
For Ireland, contact MT Agencies (Ireland) Ltd on Tel : 00353 1 844 3212
8
AUG 2011 04-XXXX
SS3, SS5, SS7, SS9
SS3, SS5, SS7, SS9
The following items should be included in the carton:
Product complete with steel grille and pre-wired mains cable. Fixing screws (2). One pair flexible installation hoses (not included with SS3 model).
Accessory grilles which fit in place standard grille are available in different colours and finishes. Please consult the price list for details. In the event of any items missing or visible damage, please contact us on 01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guarantee Registration Card with the owner of the property.
2
NOTES
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..
7
User Guide
SS3, SS5, SS7, SS9
Air Circulation (Summer Use)
Fault Finding
Ensure your central heating system is off. Set the upper switch to BLUE and the low er switch to (l) or (ll). Space Saver will run to provide a cooling flow of air. If used in conjunction eith a remote room thermostat, ensure the thermost at is set to maximum.
This Space Saver is covered by a free 5-year parts and labour guarantee. Please refer to the Fault Finding section on page 5 for advice. In the event of difficulty, please contact us on 01245 324560. It will be helpful if you do not discon nect the Space Saver from your central heating system.
6
3
User Information
Your product is covered by a free 5-year and labour guara ntee; please complete and return
the Guarantee Registration Card to us as soon as possible to ensure that shouls you require assistance, we can help you quickly and more efficently.
Your Space Saver fan convector is designed to operate as p art of your central heati ng system in
the same way as a panel radiator. Providing the lower heat ouput swi tch is left in either the normal (l) or boost position (ll) and the upper switch is in the HEATING position your Space Saver will switch on and off autom atically with your central heating s ystem.
How your Space Saver fan convector work
Hot water from your central heating system sys tem passes through a heat exchanger transferring its he at to the aluminium fins. Cooler air is drawn in by the fan an d heated as it passes through the heat exchanger before being discharged gently back into the room. This no t only gives a more even temperature spread, but will use a round 25% less energy and heat up a room in less than ha lf the time of a traditional panel radiator.
Space Saver includes an internal thermosta t that prevents the fan from operating until the central heating s ystem water passing through the heat exchanger re aches 38° C. This prevents the Space Saver circulating cool er air at start up.
Heating
Ensure your central heating system is on, th e lower switch set to normal and the upper switch to heating RED. Providing the water temperature in the system is mo re than 38° C and the thermostat controlling your cen tral heating system is calling for heat, your Space Saver will switch on .
If you require a faster warm up, move the lower swi tch to boost (ll). Moving the switch to (O) will turn off t he Space Saver.
1. We recommend the use of a knee pad w hen installing this product. Cut the opening in t he plinth to the size shown in the table. Use metho d A or B.
Model
Width A
Height B*
SS3
465mm
96mm
SS5
465mm
96mm
SS7
465mm
96mm
SS9
560mm
96mm
* The overall height of the grille is 100mm. Us e care when cutting the opening.
A
A
B
B
A
B
OPEN CLOSED
2. Fit isolating valves (not supplied) to the sys tem flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure. C onnect the flexible hoses between system pipework and heater. Open the isolating valves and check for leaks.
N.B. either pipe may be used on flow or return.
l
3. Vent air through bleed
l
4. Isolate electrical supply and co nnect the heater electric cable to the fused sp ur (3A). Ensure the fused spur is not directl y above the heater and is accessible after installation is compleate.
Commissioning
1. Turn on the electrical supply at the fused spur.
2. Set the upper control switch on the fascia grille to BLUE and the lower switch to eit her l or ll. The fan will run.
3. Turn on the central heating syst em.
4. Set any room thermostat/s to maximum.
5. Set the lower heat output switch to l and the upper switch to RED – the fan should run and heat will flow within a few minutes.
6. Balance the central heating syst em if Space Saver is installed on the same circuit as panel radiators.
7. When the installation is working correctly, remember to reset any room thermostat/s to its normal setting
4
Fault Finding
5
HOSE
BEND RADIUS
60mm MIN
Electrical Cable
Plinth
5. Position heater, making sure t he flexible hoses are not kinked and the electrical cable is not snagged.
l
6a. Fit supplied grille over top flange, locate over switches then press lower edge ba ckwards as shown in diagram to fix in place.
l
6b. Fix assembled heater to plinth using fixing screw holes located at either end of grille.
Grille to plinth securing screws
Heat Output Perormance
It is recommded that the Space Saver model chosen is capable of ma intaning the calculated heat loss at normal heat output (l) enabling the boost setting (ll) to be used for faster heat up.
Heat Output Δt 60°C
Heat Output Δt 50°C
Model
Normal
(kW)
Boost
(kW)
Normal
(kW)
Boost
(kW)
SS3
0.8
0.9
0.6
0.8
SS5
1.3
1.7
1.1
1.4
SS7
1.6
1.9
1.3
1.6
SS9
2.2
2.4
1.9
2.1
Notes:
Δt 60°C assumes a mean water temperature of 80°C and room temperature of 20°C.
Δt 50°C assumes mean a water temperature of 70°C and room temperature of 20°C.
1. Fan does not run on any swi tch setting.
a). Check the power supply is switched ON.
b). Check fuse in fused spur.
c). Check the wiring connections at the fused spur.
2. No heat output on settings l and ll.
a). Check the power supply is switched ON.
b). If fitted, ensure any room thermos tats are calling for heat.
c). Balance the central heating syst em if installed on same dircuit as panel radiators and increase the circulating pump speed if req uired.
d). Increase the boiler water temperature.
In the event of any difficulty, please contact us on 01245 324560.
It will be more helpful if you do not remove the product fro the central heating system.
Loading...