Space Saver is primarily intended for installation in the space beneath kitchen cupboards behind the plinth. However, it can also be installed in similar applications such as stair risers and other built-in furniture.
This Space Saver model must not be installed in a bathroom or other high humidity areas. Please contact us on 01245 324560 for details of products suitable for these applications.
Space Saver is designed for use on standard two­pipe pumped central heating systems. Pipes are 15mm and either may be used as flow or return. This product is not suitable for one-pipe systems.
In line with best practice, isolating valves (not supplied) must be fitted to the system flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure.
Space Saver is classified as a fixed appliance and electrical connection should be via a double pole 3A fused spur with a minimum contact gap of 3mm. The fused spur must not be directly above the heater but should be accessible after completion of the installation. If the pre-wired mains cable is damaged, it must be replaced by either the
manufacturer
, its service agent or similarly
qualified persons. The appliance must be earthed. To ensure adequate airflow, a minimum clearance
of 20mm between the top of the product and any shelving is essential.
To avoid the possibility of vibration, this product must be installed on a flat, even surface.
There must be no rear access to the product after completion of the installation.
To conform with Building R egulations Part L (Part J in Scotland), a remote room thermostat (Smith’s Part No. RT002) can be used in conjunction with this Space Saver fan convector.
Isolating valves (not supplied) should be fitted to the flow and return pipes on the heater.
The flexible installation hoses supplied are suitable for use with either 15mm diameter copper pipe or 15mm cross-linked polythene barrier pipe to BS 7291. For all other types of pipes we recommended the use of compression type fittings.
Please note the guarantee may be invalidated if this product is not installed and used in accordance with this guide.
SS3 W, SS5 W, SS7 W, SS9 W
The following items should be included in the carton:
v
v
Product complete with fixed white grille and pre-wired mains cable.
v
v
Fixing screws (2).
v
v
One pair flexible installation hoses (not included with SS3 models).
Overlay grilles which fit over the fixed white grille are available in different colours and finishes. Please consult the price list for details. In the event of any items missing or visible damage, please contact us on 01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guarantee
Registration Card with the owner of the property.
Installation Guide
1. We recommend the use of a kneepad when installing this product. Cut the opening in the plinth to the size shown in the table. Use method A or B
4. Isolate electrical supply and connect the heater electric cable to the fused spur (3A). Ensure the fused spur is not directly above the heater and is accessible after installation is complete.
2. Fit isolating valves (not supplied) to the system flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure. Connect the flexible hoses between the system pipework and heater. Open the isolating valves and check for leaks.
Model Width A Height B*
SS3 W 475mm 96mm SS5 W 475mm
96mm SS7 W 475mm 96mm SS9 W 570mm 96mm
* The overall height of the grille is 100mm. Use care
when cutting the opening
3. Vent air through the bleed screw.
A
B
1. Turn on the electrical supply at the fused spur.
2. Set the upper control switch on the fascia grille to BLUE and lower switch to either I or II. The fan will run.
3. Turn on the central heating system.
4. Set any room thermostat/s to maximum.
5. Set the lower heat output switch to I and the
Commissioning
5. Position heater, making sure the flexible hoses are not kinked and the electrical cable is not snagged.
6a. Fit overlay grille (if supplied) over fixed grille 6b. Fix heater to plinth.
upper switch to RED — the fan should run and heat will flow within a few minutes.
6. Balance the central heating system if Space Saver is installed on the same circuit as panel radiators.
7. When the installation is working correctly, remember to reset any room thermostat/s to its normal setting.
Installation Guide
Heat Output Performance
Fault Finding
In the event of any difficulty, please contact us on 01245 324560.
It will be more helpful if you do not remove the product from the central heating system.
It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat loss at normal heat output (I) enabling the boost setting (II) to be used for faster heat up.
Model Heat Output
t 60ºC Heat Output
t 50ºC
Normal
Boost Normal Boost
(kW) (kW) (kW) (kW) SS3 W 0.8 0.9 0.6 0.8 SS5 W 1.3 1.7 1.1 1.4 SS7 W 1.6 1.9 1.3 1.6 SS9 W 2.2 2.4 1.9 2.1
1. Fan does not run on any switch setting. a. Check the power supply is switched ON. b. Check fuse in the fused spur. c. Check the wiring connections at the fused spur.
2. No heat output on settings I and II. a. Check the power supply is switched ON. b.
If fitted, ensure any room thermostats are calling for heat.
c.
Balance the central heating system if installed on the same circuit as panel radiators and increase the circulating pump speed if required.
d. Increase the boiler water temperature.
Notes:
T 60ºC assumes a mean water temperature of 80ºC and room temperature of 20ºC.
T 50ºC assumes a mean water temperature of 70ºC and room temperature of 20ºC.
Space Saver 12-volt models are primarily intended for installation in the space beneath bathroom cabinets, bath panels and other high humidity areas. 12-volt models are safe to operate with wet hands.
Space Saver is designed for use on standard two­pipe pumped central heating systems. Pipes are 15mm and either may be used a flow or return. This product is not suitable for one-pipe systems.
The transformer must be located outside the bathroom or high humidity area. The 450mm lead attached to the transformer must be connected to the fused spur (mains supply).
You will need to provide a cable (twin core 0.5mm
2
for lengths up to 6 metres, 1.0mm2for longer lengths) to connect the terminals on the product to the transformer. The two single-pin male connectors are provided to connect this cable to the transformer terminals.
Space Saver is classified as a fixed appliance and electrical connection should be via a double pole 3A fused spur with a minimum contact gap of 3mm.
The fused spur should be close to the transformer and be accessible after completion of the installation. This product must not be earthed.
To ensure adequate airflow, a minimum clearance of 20mm between the top of the product and any shelving is essential. To avoid the possibility of vibration, this product must be installed on a flat even surface. There must be no rear access to the product after completion of the installation.
To conform with Building Regulations Part L (P art J in Scotland), a remote room thermostat (Smith’s Part No. RT002) can be used in conjunction with this Space Saver fan convector.
The flexible installation hoses supplied are suitable for use with either 15mm diameter copper pipe or 15mm cross-linked polythene barrier pipe to BS 7291. For all other types of pipes we recommended the use of compression type fittings.
Please note the guarantee may be invalidated if this product is not installed and used in accordance with this guide.
The following items should be included in the carton:
v
v
Product with fixed white grille.
v
v
Transformer with 450mm of pre-wired mains cable.
v
v
Two single-pin male connectors.
v
v
Fixing screws (2).
v
v
One pair flexible installation hoses.
Overlay grilles which fit over the fixed white grille are available in different colours and finishes. Please consult the price list for details. In the event of items missing or visible damage, please contact us on 01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guarantee
Registration Card with the owner of the property.
SS5 W/12V
Installation Guide
1. We recommend the use of a kneepad when installing this product. Cut the opening in the plinth to the size shown in the table. Use method A or B.
Model Width A Height B*
SS5 W/12V 475mm 96mm
* The overall height of the grille is 100mm. Use care when
cutting the opening
2. Fit isolating valves (not supplied) to the system flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure. Connect the flexible hoses between the system pipework and heater. Open the isolating valves and check for leaks.
3. Vent air through the bleed screw.
A
B