Smith's Heating First Hydronic SS3 W, Hydronic SS5 W/12V, Hydronic SS5 W, Hydronic SS5 W/Dual, Hydronic SS2E W User Manual

...
Space Saver
Discover the hidden benefits
Installation and User Guide
New
Space Saver
Installation Guide
Installation Guide
User Guide
Accessory
Hydronic 3
SS3 W SS5 W SS7 W SS9 W
Hydronic Low Voltage 7
SS5 W/12V
Hydronic/Electric 11
SS5 W/Dual
Electric 16
SS2E W
Remote Room Thermostat 22
(Part No. RT002)
Hydronic & Hydronic Low Voltage 18
SS3 W SS5 W SS7 W SS9 W SS5 W/12V
Hydronic/Electric 19
SS5 W/Dual
Electric 21
SS2E W
SS5 W/Dual
SS5 W/12V
SS9 W
Index
Space Saver is primarily intended for installation in the space beneath kitchen cupboards behind the plinth. However, it can also be installed in similar applications such as stair risers and other built-in furniture.
This Space Saver model must not be installed in a bathroom or other high humidity areas. Please contact us on 01245 324560 for details of products suitable for these applications.
Space Saver is designed for use on standard two­pipe pumped central heating systems. Pipes are 15mm and either may be used as flow or return. This product is not suitable for one-pipe systems.
In line with best practice, isolating valves (not supplied) must be fitted to the system flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure.
Space Saver is classified as a fixed appliance and electrical connection should be via a double pole 3A fused spur with a minimum contact gap of 3mm. The fused spur must not be directly above the heater but should be accessible after completion of the installation. If the pre-wired mains cable is damaged, it must be replaced by either the
manufacturer
, its service agent or similarly
qualified persons. The appliance must be earthed. To ensure adequate airflow, a minimum clearance
of 20mm between the top of the product and any shelving is essential.
To avoid the possibility of vibration, this product must be installed on a flat, even surface.
There must be no rear access to the product after completion of the installation.
To conform with Building R egulations Part L (Part J in Scotland), a remote room thermostat (Smith’s Part No. RT002) can be used in conjunction with this Space Saver fan convector.
Isolating valves (not supplied) should be fitted to the flow and return pipes on the heater.
The flexible installation hoses supplied are suitable for use with either 15mm diameter copper pipe or 15mm cross-linked polythene barrier pipe to BS 7291. For all other types of pipes we recommended the use of compression type fittings.
Please note the guarantee may be invalidated if this product is not installed and used in accordance with this guide.
SS3 W, SS5 W, SS7 W, SS9 W
The following items should be included in the carton:
v
v
Product complete with fixed white grille and pre-wired mains cable.
v
v
Fixing screws (2).
v
v
One pair flexible installation hoses (not included with SS3 models).
Overlay grilles which fit over the fixed white grille are available in different colours and finishes. Please consult the price list for details. In the event of any items missing or visible damage, please contact us on 01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guarantee
Registration Card with the owner of the property.
Installation Guide
1. We recommend the use of a kneepad when installing this product. Cut the opening in the plinth to the size shown in the table. Use method A or B
4. Isolate electrical supply and connect the heater electric cable to the fused spur (3A). Ensure the fused spur is not directly above the heater and is accessible after installation is complete.
2. Fit isolating valves (not supplied) to the system flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure. Connect the flexible hoses between the system pipework and heater. Open the isolating valves and check for leaks.
Model Width A Height B*
SS3 W 475mm 96mm SS5 W 475mm
96mm SS7 W 475mm 96mm SS9 W 570mm 96mm
* The overall height of the grille is 100mm. Use care
when cutting the opening
3. Vent air through the bleed screw.
A
B
1. Turn on the electrical supply at the fused spur.
2. Set the upper control switch on the fascia grille to BLUE and lower switch to either I or II. The fan will run.
3. Turn on the central heating system.
4. Set any room thermostat/s to maximum.
5. Set the lower heat output switch to I and the
Commissioning
5. Position heater, making sure the flexible hoses are not kinked and the electrical cable is not snagged.
6a. Fit overlay grille (if supplied) over fixed grille 6b. Fix heater to plinth.
upper switch to RED — the fan should run and heat will flow within a few minutes.
6. Balance the central heating system if Space Saver is installed on the same circuit as panel radiators.
7. When the installation is working correctly, remember to reset any room thermostat/s to its normal setting.
Installation Guide
Heat Output Performance
Fault Finding
In the event of any difficulty, please contact us on 01245 324560.
It will be more helpful if you do not remove the product from the central heating system.
It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat loss at normal heat output (I) enabling the boost setting (II) to be used for faster heat up.
Model Heat Output
t 60ºC Heat Output
t 50ºC
Normal
Boost Normal Boost
(kW) (kW) (kW) (kW) SS3 W 0.8 0.9 0.6 0.8 SS5 W 1.3 1.7 1.1 1.4 SS7 W 1.6 1.9 1.3 1.6 SS9 W 2.2 2.4 1.9 2.1
1. Fan does not run on any switch setting. a. Check the power supply is switched ON. b. Check fuse in the fused spur. c. Check the wiring connections at the fused spur.
2. No heat output on settings I and II. a. Check the power supply is switched ON. b.
If fitted, ensure any room thermostats are calling for heat.
c.
Balance the central heating system if installed on the same circuit as panel radiators and increase the circulating pump speed if required.
d. Increase the boiler water temperature.
Notes:
T 60ºC assumes a mean water temperature of 80ºC and room temperature of 20ºC.
T 50ºC assumes a mean water temperature of 70ºC and room temperature of 20ºC.
Space Saver 12-volt models are primarily intended for installation in the space beneath bathroom cabinets, bath panels and other high humidity areas. 12-volt models are safe to operate with wet hands.
Space Saver is designed for use on standard two­pipe pumped central heating systems. Pipes are 15mm and either may be used a flow or return. This product is not suitable for one-pipe systems.
The transformer must be located outside the bathroom or high humidity area. The 450mm lead attached to the transformer must be connected to the fused spur (mains supply).
You will need to provide a cable (twin core 0.5mm
2
for lengths up to 6 metres, 1.0mm2for longer lengths) to connect the terminals on the product to the transformer. The two single-pin male connectors are provided to connect this cable to the transformer terminals.
Space Saver is classified as a fixed appliance and electrical connection should be via a double pole 3A fused spur with a minimum contact gap of 3mm.
The fused spur should be close to the transformer and be accessible after completion of the installation. This product must not be earthed.
To ensure adequate airflow, a minimum clearance of 20mm between the top of the product and any shelving is essential. To avoid the possibility of vibration, this product must be installed on a flat even surface. There must be no rear access to the product after completion of the installation.
To conform with Building Regulations Part L (P art J in Scotland), a remote room thermostat (Smith’s Part No. RT002) can be used in conjunction with this Space Saver fan convector.
The flexible installation hoses supplied are suitable for use with either 15mm diameter copper pipe or 15mm cross-linked polythene barrier pipe to BS 7291. For all other types of pipes we recommended the use of compression type fittings.
Please note the guarantee may be invalidated if this product is not installed and used in accordance with this guide.
The following items should be included in the carton:
v
v
Product with fixed white grille.
v
v
Transformer with 450mm of pre-wired mains cable.
v
v
Two single-pin male connectors.
v
v
Fixing screws (2).
v
v
One pair flexible installation hoses.
Overlay grilles which fit over the fixed white grille are available in different colours and finishes. Please consult the price list for details. In the event of items missing or visible damage, please contact us on 01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guarantee
Registration Card with the owner of the property.
SS5 W/12V
Installation Guide
1. We recommend the use of a kneepad when installing this product. Cut the opening in the plinth to the size shown in the table. Use method A or B.
Model Width A Height B*
SS5 W/12V 475mm 96mm
* The overall height of the grille is 100mm. Use care when
cutting the opening
2. Fit isolating valves (not supplied) to the system flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure. Connect the flexible hoses between the system pipework and heater. Open the isolating valves and check for leaks.
3. Vent air through the bleed screw.
A
B
4. Isolate electrical supply and connect the transformer flying leads to the fused spur (3A). The transformer must be located outside the bathroom or high humidity area. Connect the single-pin male connectors to the twin core cable you have supplied.
5. Push in the connectors to the transformer terminals and connect the other end of the cable to the terminals on the back of the product.
1. Turn on the electrical supply at the fused spur.
2. Set the upper control switch on the fascia grille to BLUE and lower switch to either I or II — the fan will run.
3. Turn on the central heating system.
4. Set any room thermostat/s to maximum.
5. Set the lower heat output switch to I and the
Commissioning
upper switch to RED — the fan should run and heat will flow within a few minutes.
6. Balance the central heating system if Space Saver is installed on the same circuit as panel radiators.
7. When the installation is working correctly, remember to reset any room thermostat/s to its normal setting.
10
Installation Guide
Heat Output Performance
7a. Fit overlay grille (if supplied) over fixed grille.
7b. Fix fascia grille to plinth.
It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat loss at normal heat output (I) enabling the boost setting (II) to be used for faster heat up.
6. Position heater, making sure the flexible hoses are not kinked and the electrical cable is not snagged.
Model Heat Output
t 60ºC Heat Output
t 50ºC
Normal Boost Normal Boost
(kW) (kW) (kW) (kW)
SS5 W/12V 1.3 1.7 1.1 1.4
Notes:
T 60ºC assumes a mean water temperature of 80ºC and room temperature of 20ºC.
T 50ºC assumes a mean water temperature of 70ºC an room temperature of 20ºC.
11
Fault Finding
The following items should be included in the carton:
v
v
Product complete with fixed white grille and pre-wired mains cable.
v
v
Fixing screws (2).
v
v
One pair flexible installation hoses.
Overlay grilles which fit over the fixed white grille are available in different colours and finishes. Please consult the price list for details. In the event of any items missing or visible damage, please contact us on 01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guar
antee
Registration Card with the owner of the property.
SS5 W/Dual
In the event of any difficulty, please contact us on 01245 324560.
It will be more helpful if you do not remove the product from the central heating system.
1. Fan does not run on any switch setting. a. Check the power supply is switched ON.
b. Check fuse in the fused spur. c. Check the wiring connections at the fused spur. d. Check connections at the transformers and
product.
2. No heat output on settings I and II. a. Check the power supply is switched ON. b.
If fitted, ensure the room thermostat is calling for heat.
c. Balance the central heating system if installed
on the same circuit as panel radiators and increase the circulating pump speed if required.
d. Increase the boiler water temperature.
* The overall height of the grille is 100mm. Use care
when cutting the opening
1. We recommend the use of a kneepad when installing this product. Cut the opening in the plinth to the size shown in the table. Use method A or B.
12
Installation Guide
Space Saver is primarily intended for installation in the space beneath kitchen cupboards behind the plinth. However, it can also be installed in similar applications such as stair risers and other built-in furniture.
This Space Saver model must not be installed in a bathroom or other high humidity areas. Please contact us on 01245 324560 for details of products suitable for these applications.
Space Saver is designed for use on standard two­pipe pumped central heating systems. Pipes are 15mm and either may be used as flow or return. This product is not suitable for one-pipe systems.
Space Saver is classified as a fixed appliance and electrical connection should be via a double pole 5A fused spur with a minimum contact gap of 3mm. The fused spur must not be directly above the heater but should be accessible after completion of the installation. If the pre-wired mains cable is damaged, it must be replaced by either the manufacturer, its service agent or similarly qualified persons. The appliance must be earthed.
Space Saver is fitted with overheat protection. When operating in electric heating mode the
heater will automatically stop in the event of the heating element reaching the cut out temperature.
T
o ensure adequate airflow
, a minimum clearance of 20mm between the top of the product and any shelving is essential.
To avoid the possibility of vibration, this product must be installed on a flat, even surface.
There must be no rear access to the product after completion of the installation.
T
o conform with Building R
egulations Part L (P art J in Scotland), a remote room thermostat (Smith’s Part No. RT002) can be used in conjunction with this Space Saver fan convector.
The flexible installation hoses supplied are suitable for use with either 15mm diameter copper pipe or 15mm cross-linked polythene barrier pipe to BS 7291. For all other types of pipes we recommended the use of compression type fittings.
Please note the guarantee may be invalidated if this product is not installed and used in accordance with this guide.
A
B
Model Width A Height B*
SS5 W/Dual 475mm 96mm
13
2. Fit isolating valves (not supplied) to the system flow and return pipes. Failure to fit isolating valves may mean that the product is not serviceable in the event of failure. Connect the flexible hoses between the system pipework and heater. Open the isolating valves and check for leaks.
3. Vent air through the bleed screw.
4. Isolate electrical supply and connect the heater electric cable to the fused spur (5A). Ensure the fused spur is not directly above the heater and is accessible after installation is complete.
14
Installation Guide
5. Position heater, making sure the flexible hoses are not kinked and the electrical cable is not snagged.
1. Turn on the electrical supply at the fused spur.
2. Set the upper rocker switch on the fascia grille to the right (blue) and the lower switch to the left or right — the fan should run.
3. Set the upper rocker switch to the left (red) and the middle rocker switch to the right (electric heating). Heat will start to flow immediately. Increasing the fan speed will not increase the heat output in the electric heating mode.
4. Turn on the central heating system.
5. Set any room thermostat/s to maximum.
Commissioning
6. Set the upper rocker switch to the left (red), the middle rocker switch to the left (hydronic heating) and the lower switch to the left (normal output). The fan should run and heat will flow within a few minutes.
7. Balance the central heating system if Space Saver is installed on the same circuit as panel radiators.
8. When the installation is working correctly, remember to reset any thermostat/s to its normal setting.
6a. Fit overlay grille (if supplied) over fixed grille. 6b. Fix heater to plinth.
15
Heat Output Performance - Hydronic Model
It is recommended that the Space Saver model chosen is capable of maintaining the calculated heat loss at normal heat output (I) enabling the boost setting (II) to be used for faster heat up.
Fault Finding
In the event of any difficulty, please contact us on 01245 324560.
It will be more helpful if you do not remove the product from the central heating system.
1. Fan does not run on any switch setting or no a. Check the power supply is switched ON.
heat output on electric heating mode.
b. Check fuse in the fused spur. c.
Check the wiring connections at the fused spur
.
2. No heat output on hydronic heating mode. a. Check the power supply is switched ON. b. If fitted, ensure the room thermostat is calling
for heat.
c
.
Balance the central heating system if installed on the same circuit as panel radiators and increase the circulating pump speed if required.
d. Increase the boiler water temperature.
3. If the overheat protection has activated on a. Switch the power supply OFF at the fused spur.
electric heating mode, manually reset as follows.
b. W
ait five minutes for the overheat cut out switch
to reset and then switch the power supply ON.
Model Heat Output
t 60ºC Heat Output
t 50ºC
Normal Boost Normal Boost
(kW) (kW) (kW) (kW)
SS5 W/Dual 1.3 1.7 1.1 1.4
Notes: Dual models include an electric element which in electric heating mode will emit 1kW of heat.
T 60ºC assumes a mean water temperature of 80ºC and room temperature of 20ºC.
T 50ºC assumes a mean water temperature of 70ºC and room temperature of 20ºC.
16
Installation Guide
The following items should be included in the carton:
v
v
Product complete with fixed white grille and pre-wired mains cable.
v
v
Fixing screws (2).
Overlay grilles which fit over the fixed white grille are available in different colours and finishes. Please consult the price list for details. In the event of items missing or visible damage, please contact us on 01245 324560.
We would be most grateful if you would leave this Installation & User Guide and the
Guarantee
Registration Card with the owner of the property.
SS2E W
Space Saver is primarily intended for installation in the space beneath kitchen cupboards behind the plinth. However, it can also be installed in similar applications such as stair risers and other built-in furniture.
This Space Saver model must not be installed in a bathroom or other high humidity areas. Please contact us on 01245 324560 for details of products suitable for these applications.
Space Saver is classified as a fixed appliance and electrical connection should be via a 10A double pole fused spur with a minimum contact gap of 3mm. The fused spur must not be directly above the heater but should be accessible after completion of the installation. If the pre-wired mains cable is damaged, it must be replaced by either the manufacturer, its service agent or similarly qualified persons. The appliance must be earthed.
To ensure adequate airflow, a minimum clearance
of 20mm between the top of the product and any shelving is essential.
To avoid the possibility of vibration, this product must be installed on a flat, even surface.
There must be no rear access to the product after completion of the installation.
T
o conform with Building R
egulations Part L (P art J in Scotland), a remote room thermostat (Smith’s Part No. RT002) can be used in conjunction with this Space Saver fan convector.
Space Saver is fitted with overheat protection. The heater will automatically stop in the event of the heating elements reaching the cut out temperature.
In the event of any difficulty please contact us on 01245 324560.
Please note the guarantee may be invalidated if
this product is not installed and used in
accordance with this guide.
1
. We recommend the use of a kneepad when
installing this product. Cut the opening in the plinth to the size shown in the table. Use method A or B. For carpeted or laminated floors use method B with the product a minimum of 20mm above floor level.
Model Width A Height B*
SS2E W 475mm 96mm
* The overall height of the grille is 100mm. Use care
when cutting the opening
A
B
2. Isolate the electrical supply and connect the heater electric cable to the 10A fused spur. The fused spur must not be directly above the heater, but should be accessible after completion of the installation.
3. Position the heater, making sure the electrical cable is not snagged.
4b. If required fit the overlay grille. Remove the
screws holding the fixed grille to the plinth, place the overlay grille over the fixed grille and refit the screws.
1 Turn on the electrical supply at the fused spur. 2 Set any room thermostat/s to maximum. 3 Set the upper fan switch to ON — the fan will run. 4 Set the middle 1kW switch to ON — heat will
flow immediately (1kW).
Commissioning
5 Set the lower 2kW switch to ON — additional
heat will flow (2kW).
6 When the installation is working correctly,
remember to reset any room thermostat/s to its normal setting.
GRILLE TO PLINTH SECURING SCREWS
Fault Finding
In the event of any difficulty, please contact us on 01245 324560.
1. Fan does not run/no heat output. a. Check the power supply is switched ON.
b. Check fuse in the fused spur. c. Check the fan switch is ON.
2. If the overheat protection has activated, a. Switch the power supply OFF at the fused spur.
manually reset as follows.
b. Wait five minutes for the overheat cut out
switch to reset.
c.
Switch the power supply ON.
4a. Fix heater to the plinth.
17
User Guide
User Information
v
v
Your product is covered by a free 5-year parts and labour guarantee; please complete and return the Guarantee Registration Card to us as soon as possible to ensure that should you require assistance, we can help you quickly and more efficiently
.
v
v
Your Space Saver fan convector is designed to operate as part of your central heating system in the same way as a panel radiator. P
roviding the lower heat output switch is left in either the normal (I) or boost position (II) and the upper switch is in the HEATING position your Space Saver will switch on and off automatically with your central heating system.
Hot water from your central heating system passes through a heat exchanger transferring its heat to the aluminium fins. Cooler air is drawn in by the fan and heated as it passes through the heat exchanger before being discharged gently back into the room. This not only gives a more even temperature spread, but will heat a room up in less than half the time of a traditional panel radiator.
Space Saver includes an internal thermostat that prevents the fan from operating until the central heating system water passing through the heat exchanger reaches 42°C. This prevents Space Saver circulating cooler air at start up.
SS3 W, SS5 W, SS7 W, SS9 W & SS5 W/12V
How your Space Saver fan convector works
Ensure your central heating is on, the lower switch set to normal and the upper switch to heating RED. Providing the water temperature in the system is more than 42°C and the thermostat controlling your central heating system is calling for heat, your Space Saver will switch on.
If you require a faster warm up, move the lower switch to boost (II). Moving the switch to (O) will turn off the Space Saver.
Heating
18
19
Air Circulation (summer use)
Fault Finding
How your Space Saver fan convector works
User Information
v Your product is covered by a free 5-year parts and labour guarantee; please complete and return
the Guarantee Registration Card to us as soon as possible to ensure that should you require assistance, we can help you quickly and more efficiently.
v
v
Your Space Saver fan convector is designed to operate as part of your central heating system in the same way as a panel radiator. P
roviding you leave Space Saver in hydronic heating mode, it will switch on and off automatically with your central heating system.
SS5 W/Dual
Ensure your central heating system is off. Set the upper switch to BLUE and the lower switch to I or II. Space Saver will run to provide a cooling flow of air. If used in conjunction with a remote room thermostat, ensure the thermostat is set to maximum.
This Space Saver is covered by a free 5-year parts and labour guarantee. Please refer to the Fault Finding section on page 6 (page 11 for 12V models) for advice. In the event of difficulty, please contact us on 01245 324560. It will be helpful if you do not disconnect the Space Saver from the central heating system.
Hot water from your central heating system passes through a heat exchanger transferring its heat to the aluminium fins. Cooler air is drawn in by the fan and heated as it passes through the heat exchanger before being discharged gently back into the room. This not only gives a more even temperature spread, but will heat a room up in less than half the time of a traditional panel radiator.
A supplementary electric heating element allows you heat when the central heating system is switched off. Please note that if your central heating comes on while Space Saver is switched to electric heating mode, the element will automatically switch off. Using hydronic heating mode where possible will considerably reduce running costs.
Space Saver includes an internal thermostat that prevents the fan from operating until the central heating system water passing through the heat exchanger reaches 42°C. This prevents Space Saver circulating cooler air at start up.
User Guide
20
Hydronic Heating
Ensure your central heating system is on. Check the upper rocker switch is to the left (red), the middle rocker switch to the left (hydronic heating) and the lower rocker switch either to the left (normal) or right (boost). Providing the water temperature in the system is more than 42°C and the thermostat controlling your central heating system is calling for heat, your Space Saver will switch on. Moving the upper rocker switch to its centre position will turn off the Space Saver.
Electric Heating
Ensure the upper rocker switch is to the left (red), the middle rocker switch to the right (electric heating) and the lower rocker switch to the left (normal) and your Space Saver will switch on. Moving the lower rocker switch to boost will not increase the heat output. Moving the upper rocker switch to its centre position will turn off the Space Saver.
For your safety this Space Saver heater is fitted with automatic overheat protection. If the heater stops, turn off the power at the fused spur, wait 5 minutes and switch the power back on.
Air Circulation (summer use)
Ensure your central heating is off. Check the upper rocker switch is to the right (blue), the middle rocker switch is either to the left or right and the lower rocker switch either to the left (normal) or right (boost). Space Saver will provide a cooling flow of air. If used in conjunction with a room thermostat, ensure the thermostat is set to maximum.
Fault Finding
This Space Saver is covered by a free 5-year parts and labour guarantee. Please refer to the Fault
Finding section on page 15 for advice. In the event of difficulty, please contact us on 01245 324560. It will be helpful if you do not disconnect the Space Saver from the central heating system.
21
User Information
v Your product is covered by a free 5-year parts and labour guarantee; please complete and return
the Guarantee Registration Card to us as soon as possible to ensure that should you require assistance, we can help you quickly and more efficiently.
SS2E W
Heating
Before switching the heater on, please ensure the fascia grille is free from obstruction.
Ensure your fused spur is switched ON. Set the thermostat (if fitted) to the desired temperature. Set the upper fan switch and the middle 1kW switch to ON. If you require a faster warm up set the lower 2kW switch to ON.
To turn the heater off, set the fan switch to OFF. Please note all switches must be in the ON position to achieve 2kW heat output.
For your safety this Space Saver heater is fitted with automatic overheat protection. If the heater stops, turn off the power at the fused spur
, wait
5 minutes and switch the power back on.
Air Circulation (summer use)
Set the thermostat (if fitted) to maximum. Set the fan switch to ON. Ensure the 1kW and 2kW switches are
OFF. Space Saver will provide a cooling flow of air.
Fault Finding
This Space Saver is covered by a free 5-year parts and labour guarantee. Please refer to the Fault
Finding section on page 17 for advice. In the event of difficulty, please contact us on 01245 324560.
FAN ON OFF
OFF
OFF
1KW ON
2 KW ON
Accessory
22
Remote Room Thermostat
Location
Select a location well away from any heat, sunlight or draughts that may affect the performance of the thermostat. Locations adjacent to doors or windows must be avoided. Recommended height is 1.5m above floor level.
Fixing
Remove the front cover by depressing the cover fixing lug whilst simultaneously prising the base and the cover apart.
Remove the terminal cover.
Fix base to the wall using two screws.
Wiring
Wiring must comply with I.E.E Regulations.
This thermostat is suitable for controlling heaters up to 10A.
Maximum ambient temperature of the thermostat is 32°C.
23
Smith’s Environmental Products Ltd,
Blackall Industrial Estate, South Woodham Ferrers, Chelmsford, Essex, CM3 5UW
Tel: 01245 324900 Fax: 01245 324422
Sales E-mail: sales@smiths-env.com General Information E-mail: info@smiths-env.com Web: www: smiths-env.com