Products with this symbol (crossed out wheelie bin) cannot be disposed as household waste. Old electrical and electronic equipment must be recycled at a facility capable of handling these products and their waste by-products. If you are purchasing replacement equipment your retailer may offer a 'take back' scheme, or will be able to give details of the nearest approved authorised treatment facility. Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on our health and the environment.
Smith’s Environmental Products Ltd,
Blackall Industrial Estate, South Woodham Ferrers, Chelmsford Essex CM3 5UW
Tel: 01245 324900 After Sales: 01245 324560 Fax: 01245 324422
E-mail: info@smiths-env.com Web: www.smiths-env.com
For Ireland (Republic & Northern), contact MT Agencies on 00 353 1 864 3363
In light of our policy of continuous development Smith’s Environmental Products Ltd
reserve the right to alter specifications without prior notice.
Iss:1 8 AUG 015
External Control Harness
Caspian UVC
(Universal Concealed)
Installation and User Guide
User Information. Installation of this product must be carried out by a qualified electrician. This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance. Cleaning and user maintenance shall not be made by children without supervision. (Refer EN 60335-1 clause 7.12).
Introduction
This harness is for use with Smiths Caspian Universal concealed range of products. The wall mounted control enables the fan speed to be adjusted and controlled remotely from the heater. This accessory can also be used in addition with Smiths Adjustable low temperature cut-out.
Note: To facilitate remote wall mounting of the speed controller the user will need to prepare a suitable single gang pattress box (not supplied) for the wall plate to attach too.
Warning:
Isolate the power supply to the Caspian unit. Do not reconnect the power supply until the installation has been completed.
ALL ELECTRICAL INSTALLATIONS CONNECTIONS MUST COMPLY WITH THE LATEST EDITION OF THE IEE WIRING REGULATIONS (BS7671), AND ANY RELEVANT LOCAL AUTHORITY BYE-LAWS. CHECK THE VOLTAGE ON THE HEATER IS CORRECT FOR YOUR SUPPLY. IF IN DOUBT, CONSULT A QUALIFIED ELECTRICIAN.
Please note the guarantee may be invalidated if this product is not installed and used in accordance with these instructions.
Before commencing with the installation please check box contents:
1. 12 metre harness in two parts (connected) with connection plugs fitted.
2. Single pattress wall plate to accommodate the controller.
3. Cable clamp and screws
4. Instructions.
Items required that are not supplied (When using the harness to facilitate remote wall mounting)
1. Single gang pattress. Suitable for the type of wall where the controller is to be installed.
Installation:
ENSURE THAT THE ELECTRICAL SUPPLY TO THE PRODUCT HAS BEEN ISOLATED.
NOTE. THE USER WILL NEED TO IDENTIFY A SITE AND INSTALL A SUITABLE SINGLE GANG PATRESS BOX
2
__________________NOTES__________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________
7
Electrical Panel
(Remove x5 screws) Front Panel (Remove x4 screws)
Installing the harness or harnesses to link a maximum of four machines together.
The harness should only be used to link heaters together when the master controller has been removed from the master heater and mounted on the wall.
It is possible to connect the slave heaters into the spare plug on the harness adjacent to the wall mounted controller or the spare plug on the harness inside the master heater.
1. Connect the harness to the spare plug adjacent to the wall mounted controller or the spare plug in the heater. If using the plug in the heater feed the harness out through the square aperture in the rear of the heater (See Fig 6). Ensure the cable is then fed through one of the round slotted holes at the bottom of the aperture and secure the black plastic bush already fitted to the cable in the slotted hole.
2. Route the harness to the heater to be connected (slave) and feed the cable in through the square aperture at the rear of the heater and secure black plastic boss.
3. Disconnect the 4 way plug(s) connecting the fan(s) (depending on model) to the controller in the slave heater and connect the motor plugs to the harness.
4. Secure the harness to the electrical panel with the clamp and screws provided.
If connecting another slave unit repeat procedure as above.
5. Secure front panels and switch on electric supply to heaters.
6. Ensure boiler is turned on and any other external controls are calling for heat.
7. Adjust master controller to desired speed and check that heaters are working correctly.
(See page 5, Figure 7 for a diagram of linking multiply units together)
6
Follow these instructions when using the harness to mount the controller externally from the heater:
ENSURE THAT THE ELECTRICAL SUPPLY TO THE PRODUCT HAS BEEN ISOLATED
1. Identify the front panel and the electrical panel (Shown in red, Fig 1).
FIG 1
2. Remove the screws attaching the front panel (retain this panel for later), then remove the electrical panel to the chassis so that it becomes free (See fig 1).
3. Turn the electrical panel over to reveal the circuit board of the speed controller. Remove the four wires connected to the speed controller and trace the lead back to
the 4 way plugs which connect to the fans (This lead will be referred to as a “Control Harness”). Separate this harness from the rest of the heaters wiring and remove it.
(Controller shown attached to a wall plate)
4. Turn the electrical panel back over and remove the screw securing the control knob. Unscrew the nut securing the controller to the electrical panel and remove controller. Retain all parts for future use. (Figure 4)
5. Connect the Control Harness to the 12m harness included in this kit. There are three plugs on this end of the 12m harness and you can use any of these. Depending on the model one or two of these will not be used.
3
VR1 HIGH
VR2 LOW
Back
Front
Figure 3
Note:
If your heater was built before 20/09/14 or the colours shown in Fig 2 do not match those on your unit please refer to the below Key:
+10V (Red) = Blue Control (Yellow) = Grey Ground (Blue) = Black Tacho (White) = Brown
6. On the back side of the electrical panel there will be a stain relief cable clamp, Unscrew and fasten onto the exiting harness to the electrical panel (See Fig 5).
(Actual electrical panel may vary)
7. Refit the electrical panel. Ensure wiring is clear from fan mouths using provided cable ties if necessary.
8. Attach the controller previously removed from machine to the wall plate supplied ensure that when the knob is turned fully anti clockwise it aligns with the low mark on the plate. (Fig 4)
9. Route the 10mm cable (harness) that has been attached to the heater to the pre fitted pattress box and connect the wires as shown in fig 3.
10. Attach the controller and wall plate to the patress box and secure with the screws provided.
11. Refit front panel to machine.
12. Turn on electrical supply and any other external controls (room stat / timer etc.) and check that the machine is working correctly by adjusting speed controller.
__________________NOTES__________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________ __________________________________________
4
Linking multiple units together
UVC 90/120
Fan Fan
M F
M F
F M
Fan Fan
M F
M F
F
FMF
Speed Controller
12 m Le ad
12 m Le ad
12 m Le ad
Male Connector
Female Connector
Fan Fan
M F
M F
F M
UVC 90/120
UVC 90/120
(Diagram showing three Caspian UVC units being linked with three separate External Control Harnesses (Shown in different colours))
5
Fig 4
TO FAN
CABLE EXIT
FIX CABLE CLAMP TO HOLES ON THE BACK OF THE BRACKET