Smith-Root UBC-24 User Manual

Page 1
07292.13 UBC-24 Man
USER'S GUIDE
UBC-24
UNIVERSAL BATTERY CHARGER
Page 2
UBC-24
From AC
Battery
Under
CONTENTS
CHARGER DESCRIPTION ................................. 1
OPERATIONAL INSTRUCTIONS ................... 2
CHARGING ............................................................ 3
LEDS AND CHARGE STATUS .........................4
CONNECTORS AND INDICATORS ............... 5
CHARGING LITHIUM BATTERIES ................. 5
CHARGER OPERATING INSTRUCTIONS ... 6
STORAGE INSTRUCTIONS .............................. 7
MAINTENANCE AND CLEANING ................. 7
CHARGING OTHER SRI BATTERIES ............ 8
SPECIFICATIONS ................................................ 9
BATTERY CYCLE LOG..................................... 10
Page 3
BAT-01
UBC-24
From AC
Battery
Under
Test
CHARGER DESCRIPTION
The UBC-24 Battery Charger is a fully-auto­matic charger designed to charge lead-acid and lithium batteries for the LR-24, LR-20 Series (and earlier Smith-Root 24V models) electrofisher systems utilizing a three-stage charging sequence.
The battery charger is only designed for indoor use and should not come into contact with water or dust. In order to avoid overheating, the charger should not be covered when it is in use. Chargers filled with molding material are splash-proof, but must not be immersed in water over long periods of time. The wall socket should be easily accessible. If an op- erational error occurs, the plug should be immediately removed from the socket. The charger contains dangerous voltages and the cover should not be removed. All service or maintenance work should be carried out by qualified personnel who can get assistance by contacting the manufacturers agent. A fuse protects the product against short-circuiting and overloading.
OPERATIONAL INSTRUCTIONS
Read these instructions before using the charger
CAUTION: Old lead-acid batteries usually have a reduced capacity and are difficult to charge. Batteries in this condition should be replaced.
BAT-01
UBC-24
From AC
Battery
Under
Test
1
Battery
Under
Test
Page 4
HOW TO CHARGE BATTERIES
1. The charger and battery should be placed in a well-ventilated area during charging.
2. Do not connect the charger to the wall socket before it is connected to the battery.
3. Verify that the polarity is correct and connect the charger cable: Red to red; black to black.
4. Connect the charger to the wall socket.
5. When charging is finished, disconnect the charger from the wall socket, then disconnect the battery. Do not leave batteries on the char- ger once fully charged.
BAT-01
UBC-24
From AC
Battery
Under
Test
The battery charger is only designed for indoor use and should not come into contact with water or dust. In order to avoid overheating, the charger should not be covered when it is in use. Chargers filled with molding material are splash-proof, but must not be immersed in water over long periods of time. The wall socket should be easily accessible. If an op­erational error occurs, the plug should be immediately removed from the socket. The charger contains dangerous voltages and the cover should not be removed. All service or maintenance work should be carried out by qualified personnel who can get assistance by contacting the manufacturer’s agent. A fuse protects the product against short-circuiting and overloading.
OPERATIONAL INSTRUCTIONS
Read these instructions before using the charger
CAUTION: Old lead-acid batteries usually have a reduced capacity and are difficult to charge. Batteries in this condition should be replaced.
BAT-01
UBC-24
From AC
Battery
Under
Test
not be used in the vicinity of flammable gases. Avoid contact with oils, grease, etc., as most types of plastic can be broken down by chemicals and solvents.
2
Battery
Under
Test
Page 5
HOW TO CHARGE BATTERIES
1. The charger and battery should be placed in a well-ventilated area during charging.
2. Do not connect the charger to the wall socket before it is connected to the battery.
3. Verify that the polarity is correct and connect the charger cable: Red to red; black to black.
4. Connect the charger to the wall socket.
5. When charging is finished, disconnect the charger from the wall socket, then disconnect the battery. Do not leave batteries on the char­ger once fully charged.
BAT-01
UBC-24
From AC
Battery
Under
Test
WARNING: Explosive gases can arise while charging lead-acid batteries. Avoid sparks and open flames. Verify that there is adequate
ventilation while charging. The charger should not be used in the vicinity of flammable gases. Avoid contact with oils, grease, etc., as most types of plastic can be broken down by chemicals and solvents.
3
Battery
Under
Test
Page 6
LEDS INDICATE FOLLOWING CHARGE STATUS
FAST CHARGE
The charger is in constant current mode. Charge current is at its maximum.
FINAL CHARGE
The charger is in constant voltage mode. Charge current is less than its maximum. The battery is normally 80-95% charged. The charger stays in this mode until the charge current decreases to charge termination level.
FLOAT (Standby/Ready)
The charger is in standby mode. The battery is fully charged. The LED changes to green. Remove battery from charger. Do not leave charged battery on charger for extended periods of time.
CONNECTORS AND INDICATORS
INPUT POWER CORD: The input power plug is a
standard 120VAC three-pin with ground. Note: A cord-set specific to the customers specified coun- try will be substituted upon request. OUTPUT CORD AND CONNECTOR: The connec- tor on the end of the cord is wired to plug directly into the quick-disconnect connector on the battery pack. CHARGE STATUS LED: The top panel indicator LED indicates the battery’s state of charge (see page 4).
adapter cables available from SRI (See page 8).
CHARGING SRI LITHIUM BATTERIES
Use the adapter cable provided with all SRI 9.6Ah Lithium Batteries (#10791) with the UBC for charging purposes. The use of any other charger than the UBC-24 to charge lithium batteries will result in damage. Do not use older style Smith-Root chargers for lithium batteries.
BAT-01
UBC-24
From AC
Battery
Under
Test
BAT-01
UBC-24
From AC
Battery
Under
Test
Red
Red
Red
Red
Red
Orange
Explosive gases can arise while charging. Avoid sparks and open flames. Verify that there is adequate ventilation while charging. The charger should not be used in the vicinity of flammable anesthesia gases. Avoid chargers with plastic casing coming into contact with oils, grease, etc., as most types of plastic can be broken down by chemicals and solvents.
Fast charge
The charger is in constant current mode. Charge current is at its maximum.
Final charge
The charger is in constant voltage mode. Charge current is less than its maximum. The battery is normally 80-95% charged. The charger stays in this mode until the charge current decreases to charge termination level.
Float (Standby / Ready)
The charger is in standby mode. The battery is fully charged. The LED changes to green. The charge voltage is at standby level, which means the charger can continue to be connected to the battery. The charger can return to rapid charging if the battery is used.
WARNING
LED’s INDICATE FOLLOWING CHARGE STATUS
Charging diagram
RED RED
Red
Red
ORANGE
4
CHARGE
INDICATOR
UNIVERSAL BATTERY CHARGER
UBC-24UBC-24UBC-24
1
0
1
1
2
a
Battery
Under
Test
BAT-01
UBC-24
From AC
Battery
Under
Test
Red
Red
Page 7
CONNECTORS AND INDICATORS
INPUT POWER CORD: The input power plug is a
standard 120VAC three-pin with ground. Note: A cord-set specific to the customer’s specified coun­try will be substituted upon request. OUTPUT CORD AND CONNECTOR: The connec­tor on the end of the cord is wired to plug directly into the quick-disconnect connector on the battery pack. CHARGE STATUS LED: The top panel indicator LED indicates the battery’s state of charge (see page 4).
Users that have an inventory of older style Smith-Root elec­trofisher batter­ies with different terminal connec­tors can charge them with the UBC-24 using
adapter cables available from SRI (See page 8).
CHARGING SRI LITHIUM BATTERIES
Use the adapter cable provided with all SRI 9.6Ah Lithium Batteries (#10791) with the UBC for charging purposes. The use of any other charger than the UBC-24 to charge lithium batteries will result in damage. Do not use older style Smith-Root chargers for lithium batteries.
BAT-01
UBC-24
From AC
Battery
Under
Test
CHARGER OPERATING INSTRUCTIONS
This charger is suitable for use with all types of lead acid and lithium batteries, including the new types of maintenance-free and gelled electrolyte batteries.
1. Connect charger to battery.
2. Connect the charger to the AC power supply. The state of charge is shown by the LED indicators on the battery charger as follows. The red “Charge” LED will light to indicate that the battery is correctly connected and is charging. The indicator LED will turn green when the battery is fully charged.
3. The length of time needed for recharging will depend on the size and depth of discharge of the battery. A full charging of a large battery may take up to 12 hours.
4. For best results, the charger should be allowed to complete its full cycle as
indicated by the green LED.
BAT-01
UBC-24
From AC
Battery
Under
Test
5
CHARGE
INDICATOR
UNIVERSAL BATTERY CHARGER
UBC-24UBC-24UBC-24
1
0
1
1
2
a
1. Input Power Cord
2. Charge Status Led
3. Output Cord, Connector
1
2
3
INSET: Lithium Battery Adapter Cable
IMPORTANT SAFETY NOTE: When disconnecting the battery from the charger, switch off or unplug the AC supply to the charger first. This precaution will elimi-
nate any risk of gas explosion due to arcing.
Battery
Under
Test
BAT-01
UBC-24
From AC
Battery
Under
Test
Red
Red
Page 8
BAT-01
UBC-24
From AC
Battery
Under
Test
CHARGER OPERATING INSTRUCTIONS
This charger is suitable for use with all types of lead acid and lithium batteries, including the new types of maintenance-free and gelled electrolyte batteries.
1. Connect charger to battery.
2. Connect the charger to the AC power supply. The state of charge is shown by the LED indicators on the battery charger as follows. The red “Charge” LED will light to indicate that the battery is correctly connected and is charging. The indicator LED will turn green when the battery is fully charged.
3. The length of time needed for recharging will depend on the size and depth of discharge of the battery. A full charging of a large battery may take up to 12 hours.
4. For best results, the charger should be allowed to complete its full cycle as
indicated by the green LED.
6
IMPORTANT SAFETY NOTE: When disconnecting the battery from the charger, switch off or unplug the AC supply to the charger first. This precaution will elimi-
nate any risk of gas explosion due to arcing.
Battery
Under
Test
BAT-01
UBC-24
From AC
Battery
Under
Test
Red
Red
Orange
Beginning
Charging
Charging
Red
Red
Fully Charged
Page 9
STORAGE INSTRUCTIONS
• When not in use, store the charger indoors in a cool dry place, preferably with its original packing and carton.
• Place these instructions with the charger during storage.
MAINTENANCE AND CLEANING
• Very little maintenance is required other than protecting the charger from damage and weather.
• Coil cord when not in use.
• Clean case and cords with a slightly damp cloth.
• Examine cords for damage periodically and re­place if necessary with manufacturer approved parts.
BAT-01 BATTERY ANALYSIS TOOL
The Battery Analysis Tool is an accessory designed to oper­ate with existing Smith-Root batter­ies and chargers. Its purpose is to test back-pack Electro­fisher batteries, and to demonstrate in a clear concise manner the amount of usable life remaining in batteries being tested.
CHARGING OTHER SMITH- ROOT BATTERIES
The UBC-24 Battery Charger is designed to charge batteries for LR-Series Electrofisher Sys- tems. However, users that have an inventory of older-style Smith-Root electrofisher batteries can charge them with the following adapters:
The Model 12 Battery to LR-Series Charger Adapter (#07458) will allow you to charge Model 12 Batteries (#03298 & #02595) with the current model of UBC-24.
The LR-Series Battery to Model 12 Adapter Ca- ble (#07459) will allow you to charge LR-Series lead-acid batteries with our older, Model 12 style BC-24 Battery Charger (#04954) with a 4-pin connector.
The Lithium Battery Adapter Cable (#10791) al- lows charging of 9.6Ah Lithium batteries with the UBC. It is supplied with each Lithium battery but is also available separately.
BAT-01
UBC-24
From AC
Battery
Under
Test
Bat-01 Hookup
BAT-01 Battery Analysis Tool ......... #08041
Model 12 Battery to LR-Series Charger ..07458 LR-Series Battery to Model 12 Charger ..07459
Lithium Battery Cable .................................. 10791
7 8 9
Page 10
SPECIFICATIONS
Maximum Output Power:
Temperature Range:
Efficiency (At 100%
Output Connection:
Dimensions/Weight:
Items manufactured by companies other than Smith-Root carry the original manufacturers warranty. Please contact product manufacturer for return instructions.
All Smith-Root, Inc. manufactured products are covered by a one year warranty.
Credit & Refund Policy: Customers returning equipment, in new condition, will be given credit five days from the date of the return. A return authorization must accompany returns. Valid equipment returns include, but are not limited to, ordering incorrect equipment, funding deficits, and defective equipment returned for reimbursement. All returns are subject to a restocking fee and applicable shipping charges. The restocking fee is figured at 10% of the purchase price but not less than $20.00. Customers receiving equipment in damaged condition will be referred to the shipping company for insurance reimbursement.
07292.13 UBC-24 Manual - © 2015 Smith-Root, Inc.
CHARGING OTHER SMITH­ROOT BATTERIES
The UBC-24 Battery Charger is designed to charge batteries for LR-Series Electrofisher Sys­tems. However, users that have an inventory of older-style Smith-Root electrofisher batteries can charge them with the following adapters:
The Model 12 Battery to LR-Series Charger Adapter (#07458) will allow you to charge Model 12 Batteries (#03298 & #02595) with the current model of UBC-24.
The LR-Series Battery to Model 12 Adapter Ca- ble (#07459) will allow you to charge LR-Series lead-acid batteries with our older, Model 12 style BC-24 Battery Charger (#04954) with a 4-pin connector.
The Lithium Battery Adapter Cable (#10791) al- lows charging of 9.6Ah Lithium batteries with the UBC. It is supplied with each Lithium battery but is also available separately.
Model 12 Battery to LR-Series Charger ..07458 LR-Series Battery to Model 12 Charger ..07459
Lithium Battery Cable .................................. 10791
Page 11
SPECIFICATIONS
Input Rating:
Maximum Output Power:
60W
Load Regulation:
<200mV
Line Regulation:
<100mV
Switch Frequency:
≈40 kHz
Temperature Range:
-10°C to +40°C
Ripple:
<100mVp-p
Efficiency (At 100%
Load):
80%
Insulation Class:
Class I
Electrical Safety:
UL 60601-1, EN 60601-1, EN 60950, EN 60335-2-29
EMC Standards:
EN 60601-1-2 (Medical), EN 61000-6-3 (Emission), EN 61000-6-1 (Immunity)
Timer:
2hr 330% (also available with other values)
Input Connection:
3 pin IEC 320 (input cordset not included)
Output Connection:
Battery clips
Dimensions/Weight:
5.31” x 3.15” x 1.73” (135 x 80 x 44mm)/ 0.77 lbs. (350g)
Items manufactured by companies other than Smith-Root carry the original manufacturer’s warranty. Please contact product manufacturer for return instructions.
All Smith-Root, Inc. manufactured products are covered by a one year warranty.
Credit & Refund Policy: Customers returning equipment, in new condition, will be given credit five days from the date of the return. A return authorization must accompany returns. Valid equipment returns include, but are not limited to, ordering incorrect equipment, funding deficits, and defective equipment returned for reimbursement. All returns are subject to a restocking fee and applicable shipping charges. The restocking fee is figured at 10% of the purchase price but not less than $20.00. Customers receiving equipment in damaged condition will be referred to the shipping company for insurance reimbursement.
07292.13 UBC-24 Manual - © 2015 Smith-Root, Inc.
Page 12
BATTERY CYCLE LOG
Use this form* to record the number of times a battery has been cycled:
DATE: SERIAL #: NOTES:
BATTERY CYCLE LOG
Use this form to record the number of times a battery has been cycled:
DATE: SERIAL #: NOTES:
10
Page 13
USER'S GUIDE
UBC-24
UNIVERSAL BATTERY CHARGER
www.smith-root.com
Phone: (360) 573-0202 • Email: info@smith-root.com
Vancouver, WA USA