smev 7003, 8203, MO9202S, PI7723, PI8543 Installation And Use Manual

...
FRANÇAIS
NEDERLANDS
DEUTSCH
NORSK
SLOVENSKI
SVENSKA
SUOMI
ITALIANO
ENGLISH
ESPAÑOL
INSTALLATION / USAGE / ENTRETIEN - FR
INSTALLATIE / GEBRUIK / ONDERHOUD - NL
INSTALLATION / GEBRAUCH / WARTUNG - DE
ASENNUS / KÄYTTÖ / HUOLTO - FI
INSTALLATION / ANVÄNDNING / UNDERHÅLL - SE
INSTALLASJON / BRUK / VEDLIKEHOLD - NO
INSTALACIJA / UPOR ABA / VZDR ŽEVANJE - SI
INSTALLATION / USE / MAINTENANCE - GB
INSTALLA ZIONE / USO / MANUTENZIONE - IT
INSTALLATION / BRUG / VEDLIGEHOLDELSE - DK
INSTALACIÓN / USO / MANUTENCIÓN - ES
INSTALAÇÃO / UTILIZAÇÃO / MANUTENÇÃO - PT
PORTUGUÊS
7003 - 7023 - 7103 - 7123 - 8103 VD - 8103 VDM - 8123 VD - 8123 VDM
8203 - 8203 M - 8223 - 8223 M - MO8302 - MO8303 - MO8322 - MO8323
MO8342 - MO8362 - MO8801D - MO8801S - MO8821D - MO8821S
MO9122 - MO9202D - MO9202S - MO9222D - MO9222S - PI7203 - PI7223 - PI7703
PI7723 - PI8002 - PI8003 - PI8022 - PI8023 - PI8042 - PI8043 - PI8062 - PI8063
PI8403 - PI8423 - PI8443 - PI8463 - PI8502 - PI8503 - PI8522 - PI8523 - PI8542
PI8543 - PI8562 - PI8563 - PI8621A - PI8621R - PI8621S - PI8802D - PI8802S
PI8822D - PI8822S - PI8842D - PI8842S - PI8862D - PI8862S - PI9003 - PI9023
12
ENGLISH
SYMBOLS
WARNINGS AND SAFETY SYMBOLS The safety symbols utilised identify possible hazards to users. Always respect all safety warnings identified with these symbols:
INDEX
INSTALLATION 13 SAFETY WARNINGS 13
CABINET APERTURE 13 CONNECTING TO GAS SUPPLY 14 WIRING- CONNECTING TO ELECTRICITY SUPPLY 15 FIXTURE 15
USE 16
WARNINGS 16
CONTROLS 16 BURNERS: 17 HOB: 18 SELECTING BURNER 18 ELECTRONIC IGNITION HOB (DEPENDING ON MODEL) 18 MANUAL IGNITION HOB 18 HOB FLAME REGULATION 18 VISUAL FLAME CONTROL 19 GAS CYLINDERS / BOTTLES 1
9
MAINTENANCE 20
CLEANING 20
INJECTORS 20 SMEV ACCESSORIES 20 TEST PRESSURE POINT10
FIGURES AND TECHNICAL DRAWINGS 122-135
WARNING Hazard of injury or death.
CAUTION To prevent possible injury and / or damage
INSTALL ATIONUS E
MAINTENA NC E
13
ENGLISH
SAFETY WARNINGS
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE REGULATIONS IN FORCE AND ONLY USED IN AN ADEQUATELY VENTILATED AREA. ALWAYS READ THE INSTRUCTIONS PROVIDED THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE. THIS APPLIANCE MUST BE INSTALLED BY SPECIALISED GAS SERVICE ENGINEERS.
THIS APPLIANCE IS DESIGNED AND MANUFACTURED FOR COOKING FOOD ONLY. ANY OTHER USE IS CONSIDERED IMPROPER AND INCORRECT CREATING HAZARDOUS CONDITIONS. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR DAMAGE TO THINGS OR INJURIES TO PERSONS CAUSED BY INCORRECT INSTALLATION AND / OR INCORRECT AND IMPROPER USE.
BEFORE INSTALLING CHECK THAT THE LOCAL GAS AVAILABLE (GAS TYPE AND PRESSURE) AND THE APPLIANCE REGULATORS ARE COMPATIBLE WITH THE APPLIANCE ITSELF.
GAS REGULATING SPECIFICATIONS FOR THIS APPLIANCE ARE PROVIDED ON THE LABEL AFFIXED TO THE APPLIANCE (OR ON THE SERIAL PLATE).
THIS APPLIANCE IS NOT CONNECTED TO A FUME EXTRACTION FLUE FOR EXTRACTING PRODUCTS OF COMBUSTION THEREFORE IT MUST BE INSTALLED AND CONNECTED (FITTED) CONFORMING TO INSTALLATION REGULATIONS IN FORCE FOR APPLIANCES OF THIS TYPE. IT IS OF UTMOST IMPORTANCE TO RESPECT LEGISLATION REGARDING VENTILATION.
THE APPLIANCE MUST FITTED AT AN APPROPRIATE AND SAFE DISTANCE FROM FLAMMABLE MATERIALS.
CABINET APERTURE
This hob has a class 3 grading: BUILT-IN APPLIANCE FOR KITCHENS OR WORKTOPS
MINIMUM ALLOWABLE DISTANCES FROM WALLS (FIG. 1 - PG. 122):
A / B FROM THE OUTER EDGE OF THE BURNER HEAD NEAREST ONE OF THE SIDE WALLS AND / OR
REAR WALL: 135 mm
C THE DISTANCE BETWEEN THE TOP OF THE BURNER AND THE BOTTOM OF THE UNITS AND / OR SHELVES FITTED ABOVE THE HOB: 500 mm
D THE DISTANCE BETWEEN THE BOTTOM OF THE BURNER AND THE UNDERSIDE: 30 mm
SIZE OF CABINET APERTURE
Cut-out a hole in the cabinet as illustrated in FIG. 2 - PG. 123 depending on model to install. The cabinet must be appropriately constructed and aligned horizontally with the worktop and with the unit. The cabinet aperture must be perfectly squared and aligned. If there are apertures for cabinet ventilation, prevent flammable materials from entering these.
Models PI8621A, PI8621S and PI8621R are modular. It is possible to connect from 1 to 5 appliances in series. ALWAYS RESPECT THE DISTANCE BETWEEN ONE CABINET APERTURE AND ANOTHER (FIG. 2 – PG. 130).
INSTALL ATION
US E
MAINTENA NC E
14
ENGLISH
CATEGORY AND COUNTRY OF DESTINATION
I3B/P(30)
AT BE DK FI DE GB NL NO SE CH SI
I3+ (28-30/37)
BE FR IE IT ES CH GB PT SI
GAS PRESSURE
30 mbar Butane (G30)
30 mbar Propane (G31)
28-30 mbar Butane (G30)
37 mbar Propane (G31)
This appliance is designed for running off the following types of gas at the corresponding operating pressures. The gas category (or categories) of the appliance is given on the specifications label affixed to the appliance.
CONNECTING TO GAS SUPPLY
CHECK THESE SPECIFICATIONS BEFORE CONNECTING THE APPLIANCE TO THE GAS CYLINDER /BOTTLE. THE PRESSURE REGULATORS CONNECTED BETWEEN THE GAS CYLINDER AND APPLIANCE MUST CONFORM WITH THE CATEGORIES GIVEN IN THE TABLE BELOW.
MODEL TOTAL NOMINAL THERMAL
CAPACITY
AIR VOLUME REQUIRED FOR
COMBUSTION
MO8801D - MO8801S - MO8821D
MO8821S - PI8621A
PI8621S
PI8621R
MO8302 - MO8322 - MO8342
MO8362 - MO9202D - MO9202S
MO9222D - MO9222S PI8002 - PI8022 - PI8042 - PI8062 PI8502 - PI8522 - PI8542 - PI8562
PI8802D - PI8802S - PI8822D - PI8822S PI8842D - PI8842S - PI8862D - PI8862S
MO9122
7003 - 7023 - 7103 - 7123
8103 VD - 8103 VDM
8123 VD - 8123 VDM
8203 - 8203 M - 8223 - 8223 M
MO8303 - MO8323 - PI9003 - PI9023
PI7203 - PI7223 - PI7703 - PI7723 PI8003 - PI8023 - PI8043 - PI8063 PI8403 - PI8423 - PI8443 - PI8463 PI8503 - PI8523 - PI8543 - PI8563
kW - gr/h m3/h
1,0 - 73
1,8 - 131 2,2 - 160
2,8 - 204
3,2 - 233
3,6 - 262
3,8 - 277
4,6 - 335
2,0
3,6
4,4
5,6
6,4
7,2
7,6
9,2
INSTALL ATIONUS E
MAINTENA NC E
15
ENGLISH
FIXTURE
THIS APPLIANCE MUST BE FITTED AND SECURED TO THE CABINET UTILISING THE FIXTURE SCREWS AS ILLUSTRATED IN FIG. 3 - PG.131.
The gas supply pipe connected to the appliance must be a rigid metal pipe with sealed fittings. It is possible to fit a flexible hose, however, in this case the following conditions must be respected:
a) The hose can be accessed easily for inspection; b) The hose must be protected against coming into contact with parts which heat up (for example parts underneath the burners); c) The hose must be protected against being damaged (twisting, pulling, trapping,….); d) The hose must be protected against being trapped by moving parts (e.g. drawers); e) The hose must not have a length over 1.5 m; f) The hose must be replaced before its expiry date; For models PI8621A, PI8621S, PI8621R seal the appliance gas pipe utilising the sealed tube with pre-mounted gas fitting provided. Once the appliance has been connected to the gas supply check for gas leaks utilising a non­corrosive fluid. Do not use a water and soap solution. NEVER USE A FLAME TO TEST FOR GAS LEAKS
Models PI8621A, PI8621S and PI8621R are modular. It is possible to connect from 1 to 5 appliances in series. Disconnect and remove the sealed tube mounted to the gas pipe on the installed appliance and connect it to the gas pipe on the appliance to install. Connect the appliances together by connecting the gas pipes in series utilising the fitting.
CONNECTING TO ELECTRICITY SUPPLY
THIS APPLIANCE MUST BE CONNECTED TO A 12 VDC POWER PACK ONLY. THE CIRCUIT MUST BE FITTED WITH A SAFETY FUSE NOT HIGHER THAN 3 AMP.
WHEN WIRING RESPECT CORRECT POLARITY!
IT IS OF UTMOST IMPORTANCE NEVER TO CONNECT THIS APPLIANCE TO MAINS VOLTAGE (230 V) WHICH IRREVERSIBLY DAMAGES APPLIANCE COMPONENTS AND CREATES A HAZARD TO THE USER.
To connect the appliance use a 1.5 mm2 double red and black wire and wire to the terminal junction box located at the rear of the appliance. The red terminal is the positive pole and the black terminal is the negative pole.
This chapter refers only to models with the wording 12 VDC on the appliance specifications label affixed to the appliance.
WHEN INSTALLING AND CONNECTING THE APPLIANCE TO THE GAS SUPPLY, ENSURE THAT THE GAS SUPPLY HOSE IS NOT TWISTED, STRETCHED OR SUBJECTED TO ANY FORM OF STRAIN WHICH COULD CREATE A HAZARD.
INSTALL ATION
US E
MAINTENA NC E
16
ENGLISH
WARNINGS
THIS APPLIANCE MUST ONLY BE USED BY RESPONSIBLE ADULTS. DURING USE AND IMMEDIATELY AFTER USE THE BURNER AND OTHER ACCESSIBLE PARTS MAY BE HOT; DO NOT TOUCH THESE PARTS AND ALWAYS KEEP CHILDREN AT A SAFE DISTANCE. AFTER USING THE APPLIANCE ENSURE THE KNOB/KNOBS ARE OFF. AFTER USE ALWAYS SHUT OFF THE GAS SUPPLY AT THE MAIN GAS TAP.
THE USE OF GAS APPLIANCES GENERATES HEAT AND MOISTURE IN THE IMMEDIATE AREA. ALWAYS ENSURE A GOOD VENTILATION IN THE COOKING AREA: KEEP ALL AIR VENTS OPEN FOR NATURAL VENTILATION OR INSTALL AN EXTRACTOR FAN (COOKERHOOD).
DUE TO INTENSIVE USE OF THE APPLIANCE IT MAY BE NECESSARY TO INCREASE VENTILATION SUCH AS OPENING A WINDOW OR INCREASING COOKERHOOD (EXTRACTOR FAN) SPEED.
FOR MODELS MO8800 THE DRAINER MUST BE REMOVED WHEN UTILISING THE HOB BURNER/S.
CAUTION: THIS WARNING IS AFFIXED IN VISIBLE LOCATION ON THE HOB GLASS LID. GLASS HOB LIDS MAY SHATTER WHEN HEATED. ALWAYS RAISE THE LID BEFORE IGNITING A BURNER/S (HOB, OVEN AND GRILL) AND TURN OFF ALL BURNERS (HOB, OVEN AND GRILL) AND LET THEM COOL DOWN BEFORE LOWERING THE HOB GLASS LID.
CAUTION: THIS WARNING REFERS TO MODELS WITH INCORPORATED SINK UNIT AND HOB AND WITH GLASS LID DIVIDED BETWEEN SINK AND HOB. THIS WARNING IS AFFIXED IN A VISIBLE POSITION ON THE SINK UNIT GLASS LID. WHEN USING THE HOB WITH THE GLASS LID ON THE SINK UNIT CLOSED, ALWAYS KEEP PANS ON HOB AT A DISTANCE OF 10 MM MINIMUM FROM SINK UNIT GLASS LID.
The following symbols indicate the burner corresponding to the control knob. NOTE: different models may have different knobs and different symbols.
THIS SYMBOL IS PLACED NEXT TO THE HOB BURNER KNOBS. FULL DOT REFERS TO THE CORRESPONDING HOB BURNER.
GAS OFF
HIGH FLAME
LOW FLAME
The following symbols indicate the burner regulation corresponding to the knob position. NOTE: different models may have different knobs and different symbols.
OTHER SYMBOLS
PUSHBUTTON ELECTRONIC IGNITION
CONTROLS
INSTALL ATIONUS E
MAINTENA NC E
17
ENGLISH
BURNERS
Technical specifications for burners referring to appliance model:
7003 2 1 73 1 1,8 131 7023 2 1 73 1 1,8 131 7103 2 1 73 1 1,8 131 7123 2 1 73 1 1,8 131 8103 VD 2 1 73 1 1,8 131 8103 VDM 2 1 73 1 1,8 131 8123 VD 2 1 73 1 1,8 131 8123 VDM 2 1 73 1 1,8 131 8203 2 1 73 1 1,8 131 8203 M 2 1 73 1 1,8 131 8223 2 1 73 1 1,8 131 8223 M 2 1 73 1 1,8 131 MO8302 1 1 73 1 1,8 131 MO8303 2 1 73 1 1,8 131 MO8322 1 1 73 1 1,8 131 MO8323 2 1 73 1 1,8 131 MO8342 1 1 73 1 1,8 131 MO8362 1 1 73 1 1,8 131 MO8801D 1 1 73 MO8801S 1 1 73 MO8821D 1 1 73 MO8821S 1 1 73 MO9122 2 1,8 131 MO9202D 1 1 73 1 1,8 131 MO9202S 1 1 73 1 1,8 131 MO9222D 1 1 73 1 1,8 131 MO9222S 1 1 73 1 1,8 131 PI7203 1 1 73 2 1,8 131 PI7223 1 1 73 2 1,8 131 PI7703 1 1 73 2 1,8 131 PI7723 1 1 73 2 1,8 131 PI8002 1 1 73 1 1,8 131 PI8003 1 1 73 2 1,8 131 PI8022 1 1 73 1 1,8 131 PI8023 1 1 73 2 1,8 131 PI8042 1 1 73 1 1,8 131 PI8043 1 1 73 2 1,8 131 PI8062 1 1 73 1 1,8 131 PI8063 1 1 73 2 1,8 131 PI8403 1 1 73 2 1,8 131 PI8423 1 1 73 2 1,8 131 PI8443 1 1 73 2 1,8 131 PI8463 1 1 73 2 1,8 131 PI8502 1 1 73 1 1,8 131 PI8503 1 1 73 2 1,8 131 PI8522 1 1 73 1 1,8 131 PI8523 1 1 73 2 1,8 131 PI8542 1 1 73 1 1,8 131 PI8543 1 1 73 2 1,8 131 PI8562 1 1 73 1 1,8 131 PI8563 1 1 73 2 1,8 131 PI8621A 1 1 73 PI8621R 1 2,2 160 PI8621S 1 1,8 131 PI8802D 1 1 73 1 2,2 160 PI8802S 1 1 73 1 2,2 160 PI8822D 1 1 73 1 2,2 160 PI8822S 1 1 73 1 2,2 160 PI8842D 1 1 73 1 2,2 160 PI8842S 1 1 73 1 2,2 160 PI8862D 1 1 73 1 2,2 160 PI8862S 1 1 73 1 2,2 160 PI9003 2 1 73 1 1,8 131 PI9023 2 1 73 1 1,8 131
THERMAL CAPACITY BURNERS MODEL
SEMI-RAPID
Ø 62 mm
AUXILIARY
Ø 47 mm
RAPID
Ø 77 mm
nr. Kw gr/h nr. Kw gr/h nr. Kw gr/h
INSTALL ATION
US E
MAINTENA NC E
AUXILIARY
Ø 47 mm
from 6 to 16 cm
SEMI-RAPID
Ø 62 mm
from 16 to 22 cm
RAPID
Ø 77 mm
from 16 to 22 cm
BURNER PAN DIAMETER
18
ENGLISH
To ignite burner, gently push-in and turn the control knob to position HIGH FLAME and maintaining the knob pushed at the same time press the electronic ignition pushbutton. Once the burner is alight maintain the knob in this position for a few seconds to the ensure the flame remains alight.
-MANUAL IGNITION HOB
THE FLAME MUST NEVER EXTEND BEYOND THE EDGE OF THE PAN. CENTRE THE PAN OVER THE BURNER ENSURING STABILITY ON THE PAN SUPPORT.
- SELECTING BURNER
- ELECTRONIC IGNITION HOB (DEPENDING ON MODEL)
HOB
Manual ignition when the appliance is not fitted with the electronic ignition feature or in the event of failure in the electronic ignition.
MAKE SURE THERE ARE NO PANS OR OTHER ANY OBJECTS ON THE BURNERS WHEN IGNITING.
IF THE BRUNER DOES NOT IGNITE IMMEDIATELY REPEAT IGNITION AFTER HAVING FOLLOWED EACH STEP BELOW:
• TURN THE KNOB TO “SMALL FLAME”
• PROCEED WITH MANUAL IGNITION
• CHECK THERE IS SUFFICIENT GAS IN THE GAS BOTTLE.
IF THE APPLIANCE STILL DOES NOT IGNITE SHUT OFF THE GAS SUPPLY AT THE MAIN GAS TAP AND CONTACT YOUR LOCAL DEALER.
MAKE SURE THERE ARE NO PANS OR OTHER ANY OBJECTS ON THE BURNERS WHEN IGNITING.
To ignite burner, gently push-in and turn the control knob to position HIGH FLAME and maintaining the knob pushed at the same time light the burner with a match or gas lighter. Once the burner is alight maintain the knob in this position for a few seconds to ensure the flame remains alight.
IF THE BURNER DOES NOT IGNITE IMMEDIATELY CHECK THERE IS SUFFICIENT GAS IN THE GAS BOTTLE.
IF THE APPLIANCE STILL DOES NOT IGNITE SHUT OFF THE GAS SUPPLY AT THE MAIN GAS TAP AND CONTACT YOUR LOCAL DEALER.
- HOB FLAME REGULATION
To regulate flame turn the knob to the desired cooking flame.
Loading...