1. INSTRUCTIONS FOR SAFE AND PROPER USE _______________________________4
2. INSTALLATION OF THE APPLIANCE_________________________________________6
3. ADAPTATION TO DIFFERENT TYPES OF GAS ________________________________8
4. FINAL OPERATIONS_____________________________________________________11
5. DESCRIPTION OF CONTROLS ____________________________________________13
7. USE OF THE OVEN______________________________________________________17
8. ELECTRONIC PROGRAMMER_____________________________________________19
9. AVAILABLE ACCESSORIES _______________________________________________21
10. CLEANING AND MAINTENANCE ___________________________________________22
11. EXTRAORDINARY MAINTENANCE _________________________________________24
THESE INSTRUCTIONS ARE VALID ONLY FOR THE END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL.
INSTRUCTIONS FOR THE INSTALLER: these are for the qualified technician who must
carry out a suitable check of the gas system, install the appliance, set it functioning and carry out an inspection test.
INSTRUCTIONS FOR THE USER: these contain user advice, description of the commands and the correct procedures for cleaning and maintenance of the appliance.
4
Introduction
1. INSTRUCTIONS FOR SAFE AND PROPER USE
THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKER. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKER. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING-UP OF FOOD. ALL OTHER USES ARE CONSIDERED IMPROPER. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE.
DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE.
IT IS COMPULSORY THAT THE APPLIANCE BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES.
THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET MUST BE THE SAME TYPE AND MUST CONFORM TO CURRENT REGULATIONS. THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE APPLIANCE, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
WHEN NOT IN USE, MAKE SURE THAT THE CONTROL KNOBS ARE IN THE CORRECT (OFF) POSITION
.
NEVER PUT INFLAMMABLE OBJECTS IN THE OVEN: THEY COULD BE ACCIDENTALLY LIGHTED AND CAUSE FIRES.
THE I.D. PLATE WITH TECHNICAL DATA, REGISTRATION NUMBER AND BRAND NAME IS VISIBLY POSITIONED ON THE REAR PROTECTIVE COVER OF THE APPLIANCE. A COPY OF THE PLATE IS INCLUDED WITH THE HANDBOOK
THE PLATE MUST NOT BE REMOVED.
Introduction
5
DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB GRIDS.
DURING USE THE APPLIANCE BECOMES VERY HOT. TAKE CARE NOT TO TOUCH THE HEATING ELEMENTS INSIDE THE OVEN.
DO NOT USE CONTAINERS OR BROILERS THAT EXTEND BEYOND THE OUTER PERIMETER OF THE HOB.
THE APPLIANCE IS DESIGNED FOR USE BY ADULTS. DO NOT ALLOW CHILDREN TO GO NEAR OR PLAY WITH IT. WHEN OPERATING THE GRILL ALL ACCESSIBLE PARTS COULD BECOME VERY HOT: KEEP OUT OF THE WAY OF CHILDREN.
IF THE APPLIANCE IS TO BE POSITIONED ON A PLATFORM IT MUST BE INSTALLED IN SUCH A WAY AS TO PREVENT IT FROM SLIPPING OFF THE FORMER.
DO NOT APPLY DECORATIVE PANELS TO THE LOWER PART OF THE COOKER AS THEY MAY PREVENT CORRECT AIR CIRCULATION AND CAUSE OVERHEATING.
THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE). THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT.
BEFORE THE APPLIANCE IS PUT INTO OPERATION, ALL THE LABELS AND PROTECTIVE FILMS
APPLIED INSIDE OR OUTSIDE MUST BE REMOVED.
The manufacturer declines all responsibility for damage to persons or things caused by non­observance of the above prescriptions or by interference with any part of the appliance or by the use of non-original spares.
6
Instructions for the installer
2. INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by competent persons. Corgi gas installers
are approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990. This appliance may be installed next to a wall which is higher than the appliance, with a
minimum distance of 50 mm from the side of the appliance, as shown in the diagram showing
the correct installation conditions. Any wall cupboards or shelves must be at a distance of at least 750 m above the work surface.
2.1 Electrical connection
Make sure that the power line voltage matches the specifications indicated on the rating plate located on the rear protective cover of the appliance. This rating plate must never be removed.
If the appliance is connected to the supply by means of a fixed connection, install a multipolar cut-out device on the line, with contact opening distance equal to or greater than 3 mm, located near the appliance and in an easily reachable position.
Connection to the supply may be fixed or with plug and socket. In the latter case the plug and socket must be suitable for the cable employed and conform with the regulations in force. Regardless of the type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure that the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.
Instructions for the installer
For operation on 220-240 V∼: use an H05RR-F or H05V2V2-F type
three-core cable (3 x 2.5 mm2 on 90 cm models or 3 x 1.5 on 60 cm
models).
For operation on 380-415 V 2N∼ (only for 90 cm models): use an
H05RR-F or H05V2V2-F type four-core cable (4 x 1.5 mm
For operation on 380-415 V 3N∼ (only for 90 cm models): use an
H05RR-F or H05V2V2-F type five-core cable (5 x 1.5 mm2).
The cable end to be connected to the appliance must be provided with an earth wire (yellow-green) at least 20 mm longer.
2
).
Caution: only 90 cm wide models can be connected on a two-phase or three-phase system.
2.2 Ventilation requirements
The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 1989.
1. All rooms require an opening window or equivalent, and some rooms will require a
permanent vent as well.
2. For room volumes up to 5 m
3. If the room has a door that opens directly to the outside, and the room exceeds 1 m
vent is required.
4. For room volumes between 5 m
3
an air vent of 100 cm2 is required.
3
and 10 m3 an air vent of 50 cm2 is required.
3
no air
5. If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should
be consulted to determine the air vent requirements.
6. This appliance must not be installed in a bed sitting room of less than 20 m
3
or in a
bathroom or shower room. Windows and permanent vents should therefore not be blocked or removed without first consulting a Corgi gas installer. Failure to install appliances correctly is dangerous and could lead to prosecution.
2.3 Connecting to natural and LPG gas
Make the connection to the appliance using flexible bayonet style hose in accordance to B.S. 669. The hose connection at the rear of the appliance has a ½” BSP internal thread. Please use seal C between the flexible connection L and the appliance supply tube B. When making the connection, make sure that no stress of any kind is applied to the cooker and that the hose does not touch any sharp edges. If connecting to LPG the bayonet hose must have red bands on it.
(Please see connection diagram)
7
8
Instructions for the installer
3. ADAPT A TION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the appliance from the mains.
The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.
3.1 Replacement of nozzles on the hob
This operation requires no primary air regulation.
1. Extract the grids and remove all the caps and flame-spreader crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. replace the nozzles according to the type of gas to be used and the description in
paragraph "3.2 Burner and nozzle characteristics table".
4. Replace the burners in the correct position.
9
Instructions for the installer
Burner
Auxiliary 1.0 50 30 350 73 71 Semi rapid 1.75 65 33 450 127 125 Rapid 3.0 85 45 800 218 214 Triple crown 3.2 91 65 1500 233 229 Oven 3.2 87 48 850 233 229 Maxi oven 5.2 110 59 1200 378 371 Grill 4.0 100 // // 291 286
Burner
Auxiliary 1.0 72 350 Semi rapid 1.75 97 450 Rapid 3.0 115 800 Triple crown 3.5 140 1500 Oven 3.2 130 850 Maxi oven 5.2 164 1200
3.2 Burner and nozzle characteristics table
Rated
heating
capacity
(kW)
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Rated
heating
capacity
(kW)
Nozzle diameter
1/100 mm
3.3 Arrangement of the burners on the hob
LPG G30/G31 28/37 mbar
Reduced
flowrate
(W)
NATURAL GAS – G20 20 mbar
Flowrate
g/h G30
Reduced flowrate
BURNERS
1 Auxiliary 2 Semi rapid 3 Rapid 4 Triple crown
Flowrate
g/h G31
(W)
0
Instructions for the installer
Bruciatore
Auxiliary
S Semi rapid
Rapid
Triple crown
Oven
Grill
3.4 Burner and nozzle characteristics table (Mod. 60 cm.)
Portata
termica
nominale
(kW)
1.0 50 30 350 73 71
1.75 65 33 450 127 125
3.0 85 45 800 218 214
3.2 91 65 1500 233 229
3.2 87 48 850 233 229
3.0 87 // // 218 214
Diametro
1/100 mm
Ugello
LPG G30/G31 28/37 mbar
By-pass
mm
1/100
Portata
Bruciatore
termica
nominale
(kW)
Auxiliary
Semi rapid
Rapid
Triple crown
Oven
Grill
1.0 72 350
1.75 97 450
3.0 115 800
3.5 133 1500
3.2 130 850
3.0 130 //
NATURAL GAS – G20 20 mbar
Diametro
Ugello 1/100 mm
3.5 Arrangement of the burners on the hob (Mod. 60 cm.)
Portata
ridotta
(W)
BURNERS
Auxiliary
1.
2.
Semi rapid
3. Rapid
4. Triple crown
Portata
g/h G30
Portata ridotta
(W)
Portata
g/h G31
1
Loading...