Smeg SUK61MFX5, SSA91MFP9, SUK91MFA5, SUK91MFX5, SUK91MBL5 User Manual

...
Contents
3
1. INSTRUCTIONS FOR SAFE AND PROPER USE _______________________________4
2. INSTALLATION OF THE APPLIANCE_________________________________________6
3. ADAPTATION TO DIFFERENT TYPES OF GAS ________________________________9
4. FINAL OPERATIONS_____________________________________________________12
5. DESCRIPTION OF CONTROLS ____________________________________________14
6. USE OF THE HOB _______________________________________________________16
7. USE OF THE OVEN______________________________________________________18
8. ELECTRONIC PROGRAMMER (ONLY ON EQUIPPED MODELS) _________________21
9. AVAILABLE ACCESSORIES _______________________________________________23
10. CLEANING AND MAINTENANCE ___________________________________________24
11. EXTRAORDINARY MAINTENANCE _________________________________________26
THESE INSTRUCTIONS ARE VALID ONLY FOR THE END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL.
INSTRUCTIONS FOR THE USER: these contain user advice, description of the commands and the correct procedures for cleaning and maintenance of the appliance.
Introduction

1. INSTRUCTIONS FOR SAFE AND PROPER USE

THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKER. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKER. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING FUNCTIONS: COOKING AND HEATING-UP OF FOOD. ALL OTHER USES ARE CONSIDERED IMPROPER. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE.
DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE.
IT IS COMPULSORY THAT THE APPLIANCE BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES.
THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET MUST BE THE SAME TYPE AND MUST CONFORM TO CURRENT REGULATIONS. THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE APPLIANCE, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
WHEN NOT IN USE, MAKE SURE THAT THE CONTROL KNOBS ARE IN THE CORRECT (OFF) POSITION
NEVER PUT INFLAMMABLE OBJECTS IN THE OVEN: THEY COULD BE ACCIDENTALLY LIGHTED AND CAUSE FIRES.
TO BE INSTALLED ONLY BY AN AUTHORIZED PERSON.
.
4
THE I.D. PLATE WITH TECHNICAL DATA, SERIAL NUMBER AND BRAND NAME IS POSITIONED VISIBLY IN THE STORAGE COMPARTMENT.
THE PLATE MUST NOT BE REMOVED.
DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB GRIDS.
Introduction
5
DURING USE THE APPLIANCE BECOMES VERY HOT. TAKE CARE NOT TO TOUCH THE HEATING ELEMENTS INSIDE THE OVEN.
DO NOT USE CONTAINERS OR BROILERS THAT EXTEND BEYOND THE OUTER PERIMETER OF THE HOB.
THE APPLIANCE IS DESIGNED FOR USE BY ADULTS. DO NOT ALLOW CHILDREN TO GO NEAR OR PLAY WITH IT. WHEN OPERATING THE GRILL ALL ACCESSIBLE PARTS COULD BECOME VERY HOT: KEEP OUT OF THE WAY OF CHILDREN.
IF THE APPLIANCE IS TO BE POSITIONED ON A PLATFORM IT MUST BE INSTALLED IN SUCH A WAY AS TO PREVENT IT FROM SLIPPING OFF THE FORMER.
DO NOT APPLY DECORATIVE PANELS TO THE LOWER PART OF THE COOKER AS THEY MAY PREVENT CORRECT AIR CIRCULATION AND CAUSE OVERHEATING.
THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE). THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT.
BEFORE THE APPLIANCE IS PUT INTO OPERATION, ALL THE LABELS AND PROTECTIVE FILMS APPLIED INSIDE OR OUTSIDE MUST BE REMOVED.
DO NOT MODIFY THIS APPLIANCE.
DO NOT STORE FLAMMABLE MATERIALS IN THE APPLIANCE STORAGE DRAWER OR NEAR THIS APPLIANCE.
THE INSTRUCTIONS PACKAGED WITH THIS APPLIANCE CONTAIN IMPORTANT INFORMATION ABOUT INSTALLATION AND USE.
UNSUITABLE FOR USE IN MARINE CRAFT, CARAVANS OR MOBILE HOMES, UNLESS EACH BURNER IS FITTED WITH A FLAME SAFEGUARD.
IN CASE OF SERVICE, CONTACT YOUR NEAREST SERVICE AGENT OR DISTRIBUTOR LISTED ON THE WARRANTY CARD.
The manufacturer declines all responsibility for damage to persons or things caused by non­observance of the above prescriptions or by interference with any part of the appliance or by the use of non-original spares.
k
6

2. INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by competent persons. Corgi gas installers are approved to work to safe and satisfactory standards. All gas installation, servicing and repair wor must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990. It can be placed against walls higher than the hob, at a distance of at least 50 mm from the side of the appliance, as shown in the drawings A and B relating to the installation classes. Wall units or extractor hoods located above the hob must be at least 750 mm away from it.
Instructions for the installer
A
B
Built-in appliance Free-standing installation
A
B
Built-in appliance Free-standing installation
The appliances with a gas bottle compartment and electric oven can only be installed as class 1 (see fig. B).
7
Instructions for the installer
2.1 Electrical connection
Make sure that the power line voltage matches the specifications indicated on the rating plate located inside the storage compartment. This rating plate must never be removed.
If the appliance is connected to the supply by means of a fixed connection, install a multipolar cut-out device on the line, with contact opening distance equal to or greater than 3 mm, located near the appliance and in an easily reachable position.
Connection to the supply may be fixed or with plug and socket. In the latter case the plug and socket must be suitable for the cable employed and conform with the regulations in force. Regardless of the type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure that the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.
1 - For operation on 220-240V∼: use a three-pole H05RR-F or H05V2V2-F cable having a cross section of 3 x 2.5 mm2(90 cm wide models) or 3 x 1.5 mm2 (60 cm wide models).
2 - For operation on 380-415V2N∼(only for 90 cm wide models): use a four-pole H05RR-F or H05V2V2-F cable having
a cross section of 4 x 1.5 mm2.
3 - For operation on 380-415V3N∼(only for 90 cm wide models): use a five-pole H05RR-F or H05V2V2-F cable having
a cross section of 5 x 1.5 mm
The cable end to be connected to the appliance must be provided with ground wire (yellow-green) at least 20 mm longer.
2
Caution: only 90 cm wide models can be connected on a two-phase or three-phase system.

2.2 Ventilation requirements

The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 1989.
1. All rooms require an opening window or equivalent, and some rooms will require a permanent vent as well.
2. For room volumes up to 5 m3 an air vent of 100 cm2 is required.
3. If the room has a door that opens directly to the outside, and the room exceeds 1 m3 no air vent is required.
4. For room volumes between 5 m3 and 10 m3 an air vent of 50 cm2 is required.
5. If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should be consulted to determine the air vent requirements.
6. This appliance must not be installed in a bed sitting room of less than 20 m3 or in a bathroom or shower room.
Windows and permanent vents should therefore not be blocked or removed without first consulting a Corgi gas installer.
Failure to install appliances correctly is dangerous and could lead to prosecution.
Instructions for the installer

2.3 Connecting to natural and LPG gas

FOR THE GAS CONNECTION, SEE THE TYPE OF APPLIANCE SUPPLY TUBE
Free hexagonal connector
Make the connection to the appliance using flexible bayonet style hose in accordance to B.S. 669. The hose connection at the rear of the appliance has a ½” BSP internal thread. Please use seal C between the flexible connection L and the appliance supply tube B. When making the connection, make sure that no stress of any kind is applied to the cooker and that the hose does not touch any sharp edges.
If connecting to LPG the bayonet hose must have red bands on it.
Smooth welded connector
Make the connection to the appliance using a flexible bayonet style hose in accordance to B.S. 669. The hose connection at the rear of the appliance has a ½” BSP internal thread. Always apply a suitable sealing substance (such as Teflon tape) between the flexible connection L and the appliance supply tube B. When making the connection, make sure that no stress of any kind is applied to the cooker and that the hose does not touch any sharp edges.
If connecting to LPG the bayonet hose must have red bands on it.
8
Instructions for the installer

3. ADAPTATION TO DIFFERENT TYPES OF GAS

Before performing any cleaning or maintenance work, disconnect the appliance from the mains.
The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of operation with other types of gas the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described below.

3.1 Replacement of nozzles on the hob

This operation requires no primary air regulation.
1. Extract the grids and remove all the caps and flame-spreader crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. replace the nozzles according to the type of gas to be used and the description in paragraph "
4. Replace the burners in the correct position.
3.2 Burner and nozzle characteristics table".
9
Instructions for the installer
Burner

3.2 Burner and nozzle characteristics table (Mod. 90 cm.)

Rated
heating
capacity
(kW)
Nozzle
diameter
1/100 mm
LPG G30/G31 28/37 mbar
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.0 50 350 73 71 Semi rapid 1.8 65 450 131 129 Rapid 3.0 85 800 218 214 Triple crown 3.5 94 1500 254 250
Burner
Rated
heating
NATURAL GAS – G20 20 mbar
capacity
(kW)
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.0 72 350 Semi rapid 1.8 97 450 Rapid 3.0 115 800 Triple crown 3.5 140 1500

3.3 Arrangement of the burners on the hob (Mod. 90 cm.)

BURNERS
1 Auxiliary 2 Semi rapid 3 Rapid 4 Triple crown
10
Loading...
+ 16 hidden pages