THESE INSTRUCTIONS ARE VALID ONLY FOR THE END USER COUNTRIES WHOSE
IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL.
INSTRUCTIONS FOR THE INSTALLER: these are for the qualified technician who must
carry out a suitable check of the gas system, install the appliance, set it functioning and carry
out an inspection test.
INSTRUCTIONS FOR THE USER: these contain user advice, description of the commands
and the correct procedures for cleaning and maintenance of the appliance.
Introduction
1. INSTRUCTIONS FOR SAFE AND PROPER USE
THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN
ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE
COOKER. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE
USING THE COOKER. ALSO KEEP THE SERIES OF NOZZLES SUPPLIED. INSTALLATION MUST
BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN
FORCE. THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT
REGULATIONS IN FORCE. THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING
FUNCTIONS: COOKING AND HEATING-UP OF FOOD. ALL OTHER USES ARE CONSIDERED
IMPROPER.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE.
DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT. SEPARATE THE VARIOUS WASTE
MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE.
IT IS COMPULSORY THAT THE APPLIANCE BE GROUNDED ACCORDING TO THE METHODS
REQUIRED BY SAFETY RULES.
THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET MUST BE THE SAME
TYPE AND MUST CONFORM TO CURRENT REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE
APPLIANCE, FOLLOWING THE INSTRUCTIONS BELOW. SHOULD THE APPLIANCE NOT
FUNCTION, DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL
ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
WHEN NOT IN USE, MAKE SURE THAT THE CONTROL KNOBS ARE IN THE CORRECT (OFF)
POSITION
NEVER PUT INFLAMMABLE OBJECTS IN THE OVEN: THEY COULD BE ACCIDENTALLY LIGHTED
AND CAUSE FIRES.
TO BE INSTALLED ONLY BY AN AUTHORIZED PERSON.
.
4
THE I.D. PLATE WITH TECHNICAL DATA, SERIAL NUMBER AND BRAND NAME IS POSITIONED
VISIBLY IN THE STORAGE COMPARTMENT.
THE PLATE MUST NOT BE REMOVED.
DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB GRIDS.
Introduction
5
DURING USE THE APPLIANCE BECOMES VERY HOT. TAKE CARE NOT TO TOUCH THE
HEATING ELEMENTS INSIDE THE OVEN.
DO NOT USE CONTAINERS OR BROILERS THAT EXTEND BEYOND THE OUTER PERIMETER OF
THE HOB.
THE APPLIANCE IS DESIGNED FOR USE BY ADULTS. DO NOT ALLOW CHILDREN TO GO NEAR
OR PLAY WITH IT.
WHEN OPERATING THE GRILL ALL ACCESSIBLE PARTS COULD BECOME VERY HOT: KEEP OUT OF THE WAY OF CHILDREN.
IF THE APPLIANCE IS TO BE POSITIONED ON A PLATFORM IT MUST BE INSTALLED IN SUCH A
WAY AS TO PREVENT IT FROM SLIPPING OFF THE FORMER.
DO NOT APPLY DECORATIVE PANELS TO THE LOWER PART OF THE COOKER AS THEY MAY
PREVENT CORRECT AIR CIRCULATION AND CAUSE OVERHEATING.
THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN DIRECTIVE 2002/96/EC ON
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE).
THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY OF RETURN AND
RECYCLING ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT.
BEFORE THE APPLIANCE IS PUT INTO OPERATION, ALL THE LABELS AND PROTECTIVE
FILMS APPLIED INSIDE OR OUTSIDE MUST BE REMOVED.
DO NOT MODIFY THIS APPLIANCE.
DO NOT STORE FLAMMABLE MATERIALS IN THE APPLIANCE STORAGE DRAWER OR NEAR
THIS APPLIANCE.
THE INSTRUCTIONS PACKAGED WITH THIS APPLIANCE CONTAIN IMPORTANT INFORMATION
ABOUT INSTALLATION AND USE.
UNSUITABLE FOR USE IN MARINE CRAFT, CARAVANS OR MOBILE HOMES, UNLESS EACH
BURNER IS FITTED WITH A FLAME SAFEGUARD.
IN CASE OF SERVICE, CONTACT YOUR NEAREST SERVICE AGENT OR DISTRIBUTOR LISTED
ON THE WARRANTY CARD.
The manufacturer declines all responsibility for damage to persons or things caused by nonobservance of the above prescriptions or by interference with any part of the appliance or by the use of
non-original spares.
k
6
2. INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by competent persons. Corgi gas installers are
approved to work to safe and satisfactory standards. All gas installation, servicing and repair wor
must be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.
It can be placed against walls higher than the hob, at a distance of at least 50 mm from the side of the
appliance, as shown in the drawings A and B relating to the installation classes. Wall units or extractor
hoods located above the hob must be at least 750 mm away from it.
Instructions for the installer
A
B
Built-in appliance Free-standing installation
A
B
Built-in appliance Free-standing installation
The appliances with a gas bottle compartment and electric oven can only be installed as
class 1 (see fig. B).
7
Instructions for the installer
2.1 Electrical connection
Make sure that the power line voltage matches the specifications indicated on the rating plate
located inside the storage compartment.
This rating plate must never be removed.
If the appliance is connected to the supply by means of a fixed connection, install a multipolar
cut-out device on the line, with contact opening distance equal to or greater than 3 mm,
located near the appliance and in an easily reachable position.
Connection to the supply may be fixed or with plug and socket. In the latter case the plug and
socket must be suitable for the cable employed and conform with the regulations in force.
Regardless of the type of connection, earthing of the appliance is absolutely obligatory. Before
connection make sure that the supply line is suitably earthed. Avoid the use of reducers,
adapters or shunts.
1 - For operation on 220-240V∼: use a three-pole H05RR-F or
H05V2V2-F cable having a cross section of 3 x 2.5 mm2(90 cm
wide models) or 3 x 1.5 mm2 (60 cm wide models).
2 - For operation on 380-415V2N∼(only for 90 cm wide
models): use a four-pole H05RR-F or H05V2V2-F cable having
a cross section of 4 x 1.5 mm2.
3 - For operation on 380-415V3N∼(only for 90 cm wide
models): use a five-pole H05RR-F or H05V2V2-F cable having
a cross section of 5 x 1.5 mm
The cable end to be connected to the appliance must be
provided with ground wire (yellow-green) at least 20 mm longer.
2
Caution: only 90 cm wide models can be connected on a two-phase or three-phase
system.
2.2 Ventilation requirements
The room containing the appliance should have an air supply in accordance with B.S. 5440
part 2 1989.
1. All rooms require an opening window or equivalent, and some rooms will require a
permanent vent as well.
2. For room volumes up to 5 m3 an air vent of 100 cm2 is required.
3. If the room has a door that opens directly to the outside, and the room exceeds 1 m3 no air
vent is required.
4. For room volumes between 5 m3 and 10 m3 an air vent of 50 cm2 is required.
5. If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should
be consulted to determine the air vent requirements.
6. This appliance must not be installed in a bed sitting room of less than 20 m3 or in a
bathroom or shower room.
Windows and permanent vents should therefore not be blocked or removed without first
consulting a Corgi gas installer.
Failure to install appliances correctly is dangerous and could lead to prosecution.
Instructions for the installer
2.3 Connecting to natural and LPG gas
FOR THE GAS CONNECTION, SEE THE TYPE OF APPLIANCE SUPPLY TUBE
•Free hexagonal connector
Make the connection to the appliance using flexible bayonet style hose
in accordance to B.S. 669. The hose connection at the rear of the
appliance has a ½” BSP internal thread. Please use seal C between the
flexible connection L and the appliance supply tube B. When making the
connection, make sure that no stress of any kind is applied to the cooker
and that the hose does not touch any sharp edges.
If connecting to LPG the bayonet hose must have red bands on it.
•Smooth welded connector
Make the connection to the appliance using a flexible bayonet style hose
in accordance to B.S. 669. The hose connection at the rear of the
appliance has a ½” BSP internal thread. Always apply a suitable sealing
substance (such as Teflon tape) between the flexible connection L and
the appliance supply tube B. When making the connection, make sure
that no stress of any kind is applied to the cooker and that the hose does
not touch any sharp edges.
If connecting to LPG the bayonet hose must have red bands on it.
8
Instructions for the installer
3. ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, disconnect the appliance from the
mains.
The cooker hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. In the case of
operation with other types of gas the burner nozzles must be changed and the minimum flame
adjusted on the gas taps. To change the nozzles, proceed as described below.
3.1 Replacement of nozzles on the hob
This operation requires no primary air regulation.
1. Extract the grids and remove all the caps and flame-spreader crowns;
2. unscrew the burner nozzles with a 7 mm socket wrench;
3. replace the nozzles according to the type of gas to be used and the description in
paragraph "
4. Replace the burners in the correct position.
3.2 Burner and nozzle characteristics table".
9
Instructions for the installer
Burner
3.2 Burner and nozzle characteristics table (Mod. 90 cm.)