2 INSTALLING THE APPLIANCE______________________________________________6
3 ADAPTING TO DIFFERENT TYPES OF GAS __________________________________9
4 FINAL OPERATIONS ____________________________________________________12
5 DESCRIPTION OF FRONT PANEL CONTROLS _______________________________14
6 USING THE HOB________________________________________________________16
7 USING THE OVEN ______________________________________________________17
8 ELECTRONIC PROGRAMMER (ON SOME MODELS ONLY)_____________________21
9 DIGITAL TIMER (ON SOME MODELS ONLY) _________________________________23
10 ANALOGUE CLOCK (ON SOME MODELS ONLY) _____________________________23
11 CLEANING AND MAINTENANCE ___________________________________________24
12 EXTRAORDINARY MAINTENANCE _________________________________________26
INSTRUCTIONS FOR THE INSTALLER: these are intended for the qualified engineer who is to chec
the gas supply system and install, commission and test the appliance.
INSTRUCTIONS FOR THE USER: these provide recommendations for use, a description of the control
and the correct procedures for cleaning and maintaining the appliance.
3
1 PRECAUTIONS FOR SAFETY AND USE
THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE. TAKE GOOD CARE OF IT AND
KEEP IT TO HAND THROUGHOUT THE COOKER'S LIFE CYCLE. WE URGE YOU TO READ THIS
MANUAL AND ALL THE INFORMATION IT CONTAINS CAREFULLY BEFORE USING THE
COOKER. ALSO KEEP THE SET OF NOZZLES PROVIDED IN A SAFE PLACE. INSTALLATION
MUST BE CARRIED OUT BY QUALIFIED STAFF IN COMPLIANCE WITH THE RELEVANT
REGULATIONS. THIS APPLIANCE IS INTENDED FOR HOUSEHOLD USE AND COMPLIES WITH
THE EEC DIRECTIVES CURRENTLY IN FORCE. THE APPLIANCE IS BUILT TO PROVIDE THE
FOLLOWING FUNCTION: COOKING AND HEATING FOODS; ALL OTHER USES ARE TO BE
CONSIDERED IMPROPER.
THE MANUFACTURER DECLINES ALL LIABILITY FOR USES OTHER THAN THOSE STATED
ABOVE.
NEVER LEAVE PACKAGING RESIDUES UNATTENDED IN THE HOME.
SEPARATE WASTE PACKAGING MATERIALS BY TYPE AND CONSIGN THEM TO THE NEAREST
SEPARATE DISPOSAL CENTRE.
THE APPLIANCE MUST BE CONNECTED TO EARTH IN COMPLIANCE WITH ELECTRICAL
SYSTEM SAFETY REGULATIONS.
Presentation
THE PLUG TO BE CONNECTED TO THE POWER SUPPLY LEAD AND THE RELATIVE SOCKET
MUST BE OF THE SAME TYPE AND COMPLY WITH THE RELEVANT REGULATIONS.
THE POWER SUPPLY SOCKET MUST BE ACCESSIBLE EVEN AFTER THE APPLIANCE HAS
BEEN BUILT-IN.
NEVER DISCONNECT THE PLUG BY PULLING ON THE POWER SUPPLY LEAD.
IMMEDIATELY AFTER INSTALLATION, CARRY OUT A QUICK TEST ON THE APPLIANCE
FOLLOWING THE INSTRUCTIONS PROVIDED LATER IN THIS MANUAL. IF THE APPLIANCE
FAILS TO OPERATE, DISCONNECT IT FROM THE ELECTRICAL MAINS AND CONTACT YOUR
NEAREST SERVICE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
AFTER EACH USE, ALWAYS CHECK THAT THE CONTROL KNOBS ARE TURNED TO THE
(OFF).
NEVER PLACE FLAMMABLE OBJECTS IN THE OVEN: IF IT SHOULD ACCIDENTALLY BE
SWITCHED ON, THIS MIGHT CAUSE A FIRE.
THE NAMEPLATE WITH THE TECHNICAL DATA, SERIAL NUMBER AND MARK IS IN A VISIBLE
POSITION INSIDE THE STORAGE COMPARTMENT.
THE NAMEPLATE MUST NEVER BE REMOVED
NEVER PLACE PANS WITH BOTTOMS WHICH ARE NOT PERFECTLY FLAT AND SMOOTH ON
THE HOB PAN STANDS.
NEVER USE PANS OR GRIDDLE PLATES WHICH PROJECT BEYOND THE OUTSIDE EDGE OF
THE HOB.
4
ALWAYS KEEP HOLD OF THE HOB'S GLASS LID WHEN LOWERING IT.
WARNING: THE GLASS LID MAY SHATTER IF OVERHEATED.
TURN OFF ALL THE BURNERS AND WAIT FOR THEM TO COOL BEFORE CLOSING IT.
THE APPLIANCE BECOMES VERY HOT DURING USE. TAKE CARE NOT TO TOUCH THE
HEATING ELEMENTS INSIDE THE OVEN.
Presentation
THE APPLIANCE IS INTENDED FOR USE BY ADULTS. KEEP CHILDREN AT A SAFE DISTANCE
AND NEVER ALLOW THEM TO PLAY WITH IT.
WHEN THE GRILL IS IN OPERATION, ACCESSIBLE PARTS MAY BECOME VERY HOT: KEEP
CHILDREN AT A SAFE DISTANCE.
IF THE APPLIANCE IS MOUNTED ON A STAND, IT MUST BE INSTALLED IN SUCH A WAY THAT
IT CANNOT SLIP OFF.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
THIS APPLIANCE IS DESIGNED FOR COOKING FOOD AND IT SHALL NOT BE USED AS A
SPACE HEATER.
REPLACED APPLIANCES MUST BE TAKEN TO A SPECIAL GARBAGE COLLECTION CENTRE.
BEFORE THE APPLIANCE IS PUT INTO OPERATION, ALL THE LABELS AND PROTECTIVE
FILMS APPLIED INSIDE OR OUTSIDE MUST BE REMOVED.
The manufacturer declines all responsibility for injury or damage caused by failure to comply with
the above regulations or deriving from tampering with even just one part of the appliance and the use
of non-original spare parts.
5
2 INSTALLING THE APPLIANCE
It is the law that all gas appliances are installed by authorised persons. Clearance around
the cooker must comply with the requirements of AS5601.
2.1 Electrical connection
Check that the voltage and size of the power supply line are as specified on the nameplate inside the
storage compartment.
This nameplate must never be removed.
If a permanent connection to the electrical mains is used, the appliance's power supply line must be
fitted with an omnipolar breaking device with contact breaking gap of at least 3 mm located in an
easily accessible position close to the appliance itself.
For operation on 220-240 V∼: use an H05RR-F or H05V2V2-F type
three-core cable (3 x 2.5 mm2).
For operation on 380-415 V 2N∼: use an H05RR-F or H05V2V2-F
type four-core cable (4 x 1.5 mm2).
For operation on 380-415 V 3N∼: use an H05RR-F or H05V2V2-F
type five-core cable (5 x 1.5 mm2).
The cable end to be connected to the appliance must be
provided with an earth wire (yellow-green) at least 20 mm
longer.
Instructions for the Installer
The manufacturer declines all responsibility for damage to persons or things caused by nonobservance of the above prescriptions or by interference with any part of the appliance.
6
Instructions for the Installer
Overall dimensions: location of gas and electrical connection points (all measures in mm).
A 60
B 410
C 60
D 70
2.2 Gas connection
This appliance is suitable for installation with Natural Gas or LPG (propane). Refer to
page 12 for the relevant burner pressure and appropriate injector sizes. When the
appliance is to be connected to Natural Gas then the pressure regulator supplied
must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied
either with the regulator or as a separate fitting in the case of LPG (propane)
appliances.
Connection of the appliance to the gas supply must be in accordance with the
requirements of AS5601. A ½” BSP connector at the inlet is recommended and the
gas supply line to the appliance must be of adequate length to allow sufficient
withdrawal of appliance for service or disconnection and be annealed copper pipe.
The cooker must be installed with provision to allow the gas to be turned off and
disconnected for servicing and removal of the appliance as required from the gas
supply.
Before the cooker is operated make certain all relevant parts are placed in the
correct position.
When the installation is completed the installation connections of cooker will require
to be leak tested, the burner operating pressure and flame checked and adjusted.
Warranty service calls do not cover these adjustments!
To check the operating pressure of the appliance it is recommended at least 2 large
size burners are used. Ensure appliance is secured to wall when installation is
completed.
N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the
appliance. An approved manual shut-off valve must be installed. The N.G. regulator
must be checked and adjusted to 1.0kPa after installation.
L.P.G. Can be connected to the inlet fitting directly. The pressure must be
checked to ensure it is operating at 2.75kPa. A separate test point fitting must
be installed between the piping & the appliance for the pressure to be checked
to ensure it is operating at 2.75kPa.
7
Instructions for the Installer
2.3 Room ventilation
Caution – This cooker may only be installed and operated in rooms permanently ventilated
in accordance with current regulations. For proper operation of a gas appliance it is
essential for the air necessary for combustion of the gas to be able to flow naturally into the
room. Air must flow directly into the room through openings in its outside walls. This (these)
opening (s) must have a free passage cross-section of at least 100 cm2, or 200 cm2 for
appliances not equipped with gas safety device. These openings must be constructed so
that they cannot be obstructed indoors or outdoors, and should preferably be close to the
floor on the side opposite to the combustion gas discharge point. If it is not possible to
make the openings in the room where the cooker is installed, the necessary air may be
taken from an adjoining room, proveded it is not a bedroom or a room with fire risk.
2.4 Clearance above and around domestic cookers
Extract from AS5601
8
REQUIREMENTS
1 Overhead clearances – (Measurement A)
Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s
instructions. However, in no case shall the clearance between the highest part of the hob of the
cooking appliance and a range hood be less than 600mm or, for an overhead exhaust fan, 750mm.
Any other downward facing combustible surface less than 600 mm above the highest part of the hob shall be protected for the full width and depth of the cooking surface area in accordance with
Clause 5.12.1.2. However, in no case shall this clearance to any surface be less than 450 mm.
2 Side clearances – (Measurements B & C)
Where B, measured from the periphery of the nearest burner to any vertical combustible surface, is
less than 200 mm, the surface shall be protected in accordance with Clause 5.12.1.2 to a height C
of not less than 150 mm above the hob for the full dimension (width or depth) of the cooking surface
area. Where the cooking appliance is fitted with a ‘splashback’, protection of the rear wall is not
required.
3 Additional requirements for Freestanding and Elevated Cooking Appliaces – (Measurements D & E)
Where D, the distance from the periphery of the nearest burner to a horizontal combustible surface
is less than 200 mm, then E shall be 10 mm or more, or the horizontal surface shall be above the
trivet. See insets above.
y
NOTES
1 Requirement 3 does not apply to a freestanding or elevated cooking appliance which is
2 The ‘cooking surface area’ is defined as that part of the appliance where cooking normally
3 For definition of hob, see Clause 1.4.64.
4 For definition of trivet, see Clause 1.4.109.
5 Consideration is to be given to window treatments when located near cooking appliances.
3 ADAPTING TO DIFFERENT TYPES OF GAS
Before carrying out the operations described below, disconnect the appliance from the electricit
supply.
Instructions for the Installer
designed to prevent flames or the cooking vessels from extending beyond the periphery of
the appliance.
takes place and does not include those parts of the appliance containing control knobs.
See Clause 5.3.4.
1. Remove the pan stands, all the burner caps and the flame diffuser rings
The hob of the cooker is adjusted for use with either natural gas at a pressure of 1.0kPa. If used with
other types of gas, you have to replace the nozzles, then adjust the minimum flame on the gas taps.
For nozzle replacement and burner adjustment operate as described in the following paragraph.
3.1 Changing the hob nozzles
2. Use a 7 mm socket wrench to unscrew the burner nozzles;
3. Replace the burner nozzles depending on the type of gas to be used (see point “3.2 Burner and
internal auxiliary
Oven 3.2 130 850
Maxi oven 5.2 164 1200
Grill 2.9 130 //
Maxi grill 4.0 150 //
*= the identical nozzles are the external ones. The smallest diameter nozzle is the central one
3.2 Burner and Nozzle Data Tables
Nominal
heat
capacity
(kW)
By-pass
diameter
1/100 mm
0.9 46 30 350 73 71
Nominal
heat
capacity
(kW)
1/100 mm
1.0 70 350
mm
1/100
LPG(PROPANE)–2.75KPa
Reduced
heat capacity
(W)
NG–2.0KPa
Reduced heat capacity
Flow rate
g/h G30
(W)
Flow rate
g/h G31
10
Loading...