WARNING
--------------------------------------------------
The distance between the hob and the lower part of the hood must be at least 65 cm.
The air collected must not be conveyed into a duct used to blow off smokes from ap­pliances fed with an energy other than electricity (central heating systems, ther­mosiphons, water-heaters, etc.).
Comply with the official instructions provided by the competent authorities in merit when installing the disposal duct.
The room must be well aerated in case a hood and some other heat equipment fed with an energy other than electricity (gas, oil, coal heaters, etc) operate at the same time. In fact the intake hood, disposing of air, could create a vacuum in the room. The vacuum should not exceed 0,04mbar. This prevents the gas exhausted by the heat source from being intaken again. It is therefore advisable to ensure the room contains air taps able to ensure a steady flow of fresh air.
ATTENTION: This appliance must be grounded.
The following warning is valid in the United Kingdom only:
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: – the wire which is coloured green and
yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol [ ], or co­loured green or green and yellow;
– the wire which is coloured blue must be
connected to the terminal which is marked with the letter N or coloured black;
– the wire which is coloured brown must be
connected to the terminal which is marked with the letter L or coloured red.
When making the electrical connections, check that the current socket has a ground connection and that the voltage values
correspond to those indicated on the data plate inside the appliance itself. In case your appliance is not furnished with a non separating flexible cable and has no plug, or has not got any other device ensu­ring omnipolar disconnection from the elec­tricity main, with a contact opening distance of at least 3 mm, such separating device ensuring disconnection from the main must be included in the fixed installation.
Always switch off the electricity supply be­fore carrying out any cleaning or servicing operations on the appliance.
USE
--------------------------------------------------
Avoid using materials which could cause spurts of flame (flambées) near the ap­pliance.
When frying, take particular care to prevent oil and grease from catching fire. Already used oil is especially dangerous in this re­spect. Do not use uncovered electric grates.
To avoid possible risks of fire always comply with the indicated instructions when cleaning anti-grease filters and when removing grease deposits from the appliance.
MAINTENANCE
--------------------------------------------------
Thorough servicing guarantees correct and long-lasting operation.
Particular care must be paid to the grease filtering panels which must be periodically cleaned in relation to use (at least once every two months). Remove the grease filters and wash them either by hand or in the dishwasher using neutral detergent.
Use lukewarm water and neutral detergent to clean painted appliances. Never use products containing abrasives. Take great care to prevent the use of corro­sive or abrasive products when cleaning steel, copper or brass appliances. It is advi­sable to use specialized products according to the manufacturer’s instructions.
DESCRIPTION
The equipment can be used for external evacu­ation, suction, or for internal recycling of air, filtering.
When the Filtering version is in use, the air and fumes cleaned by the active charcoalfilter are recirculated in the room (Fig. 1).
When the Ducting version is in use the fumes are conveyed upwards through a flue pipe and evacuated directly towards the outside (Fig. 2). The charcoalfilters are no more necessary.
INSTALLATION
To fit apparatus into cupboard: (Fig. 3)
Fit the apparatus to the cupboard using the screws supplied.
Screws "B" serve to hook up the apparatus to the bottom of the cupboard. Insert these screws working from the bottom of the visor after open­ing it fully.
Also the hood must be fixed to the wall unit using the lateral brackets. Fix the brackets to the hood using the screws marked D provided, and using the appropriate slotted plates which allow the width from the brackets to the side of the wall unit to be adjusted between 20 and 16 mm (Fig. 4). The brackets are hooked onto the wall unit using the appropriate screws marked C (Fig. 3).
To cover any possible gap between back of hood and wall, the spacers provided should be positioned appropriately (Fig. 5-6-7).
For any substitution of the front-block on visor operate as follow (Fig. 8):
Slide the visor until completely open. – To gain access to the front-block screws,
disconnect the switch-board metal protec-
tion 1 by unscrewing screws B. – Disconnect the front-block 2 by screws C. – Once the new front-block is in place reinsert
the switch-board metal protection.
OPERATION (Fig. 9)
---------------------------------------------------
"A" - Fan on selector switch. In position 1 the
motor is automatically switched on when the telescopic visor is opened. In position 0 the motor is always off.
"B" - Motor operating speed selector switch
operating via an electronic speed variator.
"C" - Light on selector switch; in the AUT
position the light will automatically be switched on and off when the telescopic visor is opened/closed. When position 0 is selected the light re­mains off, regardless of the visor position. When switched to MAN, the light can be switched on regardless of the visor position.
Special care should be given to the anti-grease filtering panels which should be periodically cleaned according to use (every two months at the most) by washing it in luke-warm water either by hand or in a dishwashing machine, at a temperature of 60°.
To remove the two grease-trap panels (Fig. 10), move the stays to the inside and rotate the filter panel downwards until it is completely released from its seating. To replace the two filters, repeat the operation in reverse order.
If the filter version of the hood is used, the activated carbon filters will need to be replaced every 6 months. To remove the filters, proceed as follows: (Fig. 11) Fully open telescopic visor and remove grease­trap panels as described. The filters will then be accessible; grip filter and rotate clockwise to release the bayonet hole of each filter from the stay pins. Remove the other support from the connection housing and remove filters. To replace new filters, repeat the operation in reverse order.
To obtain access to the lighting lamp, remove the light fitting by unscrewing fixing screws (Fig. 12). Replace with lamps of the same type.
Deutsch
MONTAGE UND GEBRAUCHSANWEISUNG
Das Gerät ist so zu montieren, daß der Abstand zwischen den Kochplatten und dem unteren Rand der Dunstabzugs-
haube mindestens 65 cm beträgt. Ein Anschluß der Abluftleitungen an Ver-
brennungs-Abgaskamine (z.B. der Zen­tralheizung usw.) ist nicht zulässig.
In jedem Fall sind bei der Ableitung der Abluft die behördlichen Vorschriften zu beachten.
Achtung! Bei gleichzeitigem Betrieb einer
Abluft-Dunstabzugshaube und einer raum­luftabhängigen Feuerstätte (wie z.B. gas-, öl- oder kohlebetriebene Heizgeräte, Durch­lauferhitzer, Warmwasserbereiter) ist Vorsicht geboten, da beim Absaugen der Luft durch die Dunstabzugshaube dem Aufstellraum die Luft entnommen wird, die die Feuerstätte zur Verbrennung benötigt. Ein gefahrloser Betrieb ist möglich, wenn bei gleichzeitigem Betrieb von Haube und raumluftabhängiger Feuerstätte im Aufstell­raum der Feuerstätte ein Unterdruck von höchstens 0,04 mbar erreicht wird und damit ein Rücksaugen der Feuerstättenabgase vermieden wird.
Dies kann erreicht werden, wenn durch nicht verschließbare Öffnungen, (z.B. in Türen, Fenstern, Zuluft-/Abluftmauerkasten, oder andere technische Maßnahmen, wie gegenseitige Verriegelung o.ä.), die Ver­brennungsluft nachströmen kann. Anmerkung: Bei der Beurteilung muß immer der gesamte Lüftungsverbund der Wohnung beachtet werden. Bei Betrieb von Kochgeräten, z.B. Kochmulde und Gasherd, wird diese Regel nicht angewendet. Im Zweifelsfalle muß der zuständige Schorn­steinfegermeister zu Rate gezogen werden.
Beim elektrischen Anschluß müssen die Spannungswerte des Stromnetzes mit den Werten des im Inneren des Geräts angebrachten Typenschildes überein­stimmen.
Vor jeder Reinigungs- oder Wartungs­arbeit, muß das Gerät vom Stromnetz getrennt werden. Falls das Gerät nicht an eine immer gut zugängliche Steck­dose angeschlossen wird, ist in der Installation eine allpolige Trennvor­richtung vom Netz, mit einer Kontakt­öffnungsweite von mindestens 3 mm pro Pol vorzusehen.
GEBRAUCH
Offenes Feuer, bzw. der Gebrauch von Elektrogrills unter dem Gerät ist zu ver­meiden. Beim Fritieren, besonders mit mehrmals benutztem Öl, besteht Brand­gefahr. Auch bei Nichtbeachtung der Reinigungsanweisungen besteht die Gefahr eines Brandes.
WARTUNG
Nur eine sorgfältige Pflege garantiert auf Dauer eine gute Leistung und Funktion des Geräts.
Besonders wichtig ist die Reinigung der Fettfilter. Hierzu sind die Metallfettfilter abzunehmen. Die Reinigung wird von Hand, mit biologisch abbaubarem Reini­gungsmittel, oder in der Spülmaschine empfohlen. Die Reinigungshäufigkeit hängt ab von der Benutzungsdauer und der Art der abzusaugenden Wrasen.
Das Gerät selbst ist mit lauwarmem Was­ser und mildem Reinigungsmittel, ohne Scheuerzusatz, zu reinigen. In keinem Fall sind kratzende, ätzende oder agres­sive Reinigungsmittel und Hilfsmittel zu verwenden. Verwenden Sie für Edelstahlgeräte Spe­zialprodukte zur Edelstahlpflege. Die jeweilige Gebrauchsanweisung des verwendeten Produktes ist unbedingt zu beachten.
GERÄTEAUSFÜHRUNG
Das Gerät kann im Umluftbetrieb (Abb. 1) oder im Abluftbetrieb (Abb. 2) eingesetzt werden.
Im Umluftbetrieb wird die Luft zusätzlich durch Aktivkohlefilter geleitet und in den Raum zurückgeführt.
Im Abluftbetrieb wird der Kochdunst durch Abluftrohre ins Freie geleitet. Kohlefilter sind im Abluftbetrieb nicht erfor­derlich.
MONTAGE DES GERÄTS (Abb. 3)
Das Gerät ist unter Verwendung der beige­packten Schrauben zu montieren.
Mit den Schrauben B wird das Gerät an der Unterkante des Hängeschrankes befestigt. Hierzu ist das Unterteil des Teleskopfilters zu öffnen.
Das Gerät muß außerdem mit den seitlichen Bügeln am Hängeschrank befestigt werden. Die Bügel mit den zur Ausrüstung gehörenden Schrauben D am Gerät befestigen und dazu die entsprechenden Aufhängeösen verwenden, die die Breiteneinstellung von den Bügeln zu den Seiten des Hängeschrankes von 20 bis 16 mm ermöglicht (Fig. 4). Das Einhaken der Bügel am Hängeschrank erfolgt durch die Schrauben C (Fig. 3).
Um eventuelle Hohlräume in der Tiefe zwischen dem Gerät und der Wand auszugleichen, kön­nen die entsprechenden, beigefügten Distanz­stücke, die nach Bedarf eingesetzt werden
können (Fig. 5-6-7), verwendet werden. Zum evtl. Austausch der Griffleiste des Aus-
zugteils wie folgt vorgehen (Fig. 8): – Das Ausziehteil ganz öffnen.
Um an die Halteschrauben des Vorderteils
zu gelangen, die Abdeckung der Schaltung
1 durch Lösen der Schrauben B entfernen. – Die Griffleistë 2 durch Lösen der Schrauben
C abnehmen. – Nach Befestigung der neuen Griffleiste die
Abdeckung der Schaltung wieder einset-
zen.
SCHALTUNG DES GERÄTS (Abb. 9)
"A" - Hauptschalter für den Motor.
1 = das Gerät wird beim Ausziehen des Teleskopfilterteils automatisch auf der mit Schalter B gewählten Geschwindigkeit in Betrieb gesetzt. 0 = der Motor ist generell ausgeschaltet.
"B" - Stufenlose Geschwindigkeitsregelung des
Motors.
"C" - Beleuchtungsregelung.
AUT = die Beleuchtung wird beim Auszie­hen des Teleskopfilterteils automatisch eingeschaltet. 0 = die Beleuchtung ist generell einge­schaltet. MAN = die Beleuchtung ist generell einge­schaltet, auch bei geschlossenem Tele­skopfilterteil.
Um die Metallfettfilter abnehmen zu können, drückt man die Verriegelung nach innen und dreht den Filter nach unten aus der Halterung. Zum Wiedereinsetzen der Metallfettfilter geht man in umgekehrter Reihenfolge vor (Fig. 10).
Soweit das Gerät im Umluftbetrieb betrieben wird, sind die Aktivkohlefilter mindestens alle 6 Monate auszutauschen. Hierbei geht man folgendermaßen vor (Fig. 11): Zunächst zieht man das Teleskopfilterteil vollständig aus und entfernt den Metallfettfilter, wie bereits beschrieben. Die Aktivkohlefilter befinden sich über den Ansaugöffnungen der Motore. Sie können durch Drehen im Uhrzeigersinn gelöst und in um­gekehrter Drehrichtung eingesetzt werden.
Wechsel der Leuchtstofflampe (Fig. 12) Hierzu ist nach Lösen der Sicherungsschraube die Lichtabdeckung abzunehmen. Nun können Leuchtstofflampe oder Starter gewechselt werden.