Smeg RCKF Instructions Manual

EN
Warning!!!
The remote control replicates the functions on the control panel supplied with the hood. For a clearer understanding of these functions, please consult the instruction manual enclosed with the hood itself.
Warning
• The remote control is powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03-AAA type (not included).
• Used batteries must be thrown in the battery bank.
Start up and dis­connect the func­tion Delay (where the hood is pro­vided for).
Long pressure, switch on /off 24H function (where the hood is provided for).
Increases the working speed.
Turns the suction mo­tor on and off.
Decreases the working speed.
Start up / discon­nect the motor to the intensive speed starting from each speed (even with switched off mo­tor).
Short pressure, switch on /off lights up to the highest brightness.
Long pressure, switch on /off lights up to soft light (where the hood is provided for).
(A - C) (A - C)
A
B
E
C
D
F
G
L
I
H
F
A
B
E
C
D
G
L
I
H
A
B
C
D
E F G HA B C D
F
E
(B – F - G) (A – D)
LS1T1 T2 T3 T4
T4
T2
A B C D E F G H
(A - E) (H)
A B C D E F G H
A B C D E F G H
Activation process of remote control Receiver
Before carrying out any activation of the remote control it is necessary to verify the correct functioning of it. In the case that of the activation is necessary, please follow the below instructions.
This activation should be carried out exclusively from the hood control panel.
PROCEDURE A
• Switch off the light and the motor.
• Press the “Delay”-key for about 5 seconds until:
• the leds OFF MOTOR and SPEED 1 flash twice to indicate the ACTIVATION of the remote control receiver;
• the leds OFF MOTOR and SPEED 1 flash once indicate the DISCONNECTION of the remote control re-
ceiver;
G
H
PROCEDURE B
• Switch off the light and the motor.
• Press the “Intensive”-key for about 5 seconds until:
• the relative Led flash twice to indicate the ACTIVATION of the remote control receiver;
• the relative Led flash once to indicate the DISCONNECTION of the remote control receiver;
PROCEDURE C
• Press the “24H”-key for about 5 seconds until the icons of activated functions will be lit.
• When releasing the key, the
-symbol starts to flash, within 3 seconds press again the “24H”-key and the follow-
ing will appear on the display:
• the points under the motor LEDS
are lit, the receiver of the remote control is ACTIVATED;
• the points under the motor LEDS are unlit, the receiver of the remote control is DISCONNECTED.
Loading...