Smeg LR4 User manual [GB]

-EN- LR4/DS -
19390300802-EN.doc 1 Rev. 01 - 30/07/2019
LR4/DS - INSTRUCTIONS FOR ASSSEMBLY AND USE
Read the safety warnings and instructions for the thermodisinfectors in which the rack is used with care, together with the safety instructions of the producer of the glassware and any other item placed on the rack. Badly positioned items or glass which shatters during washing may cause dangerous injuries. If necessary, washing results must be checked and subjected to non-visual inspections.
1 LIST OF COMPONENTS SUPPLIED
Qt.y
PART
NUMBER
DESCRIPTION
Qt.y
PART
NUMBER
DESCRIPTION
TC40
LM40 central pipe (only without DS version).
12
U6260
Stainless steel nozzle D=6 H=260 (mm)
TC40DS
LM40DS central pipe (only for DS version)
1 - Nozzle spanner
NOZZLE
(E.g. U390 means
Stainless steel nozzle with
D= 3mm and H= 90mm)
-EN- LR4/DS -
19390300802-EN.doc 2 Rev. 01 - 30/07/2019
2 BLOW-UP DIAGRAM
The blow-up diagram below is guideline; request up-to-date information on spare parts from your Smeg contact, with reference to www.smegtech.com.
-EN- LR4/DS -
19390300802-EN.doc 3 Rev. 01 - 30/07/2019
3 NOZZLE ASSEMBLY DIAGRAM
Rear
1
1
1
1
1
1
1
1
1
1
1
1
Front
POSITION
DESCRIPTION
U6260
-EN- LR4/DS -
19390300802-EN.doc 4 Rev. 01 - 30/07/2019
4 ASSEMBLY SEQUENCE
ILLUSTRATION
PROCEDURE
Fig.1
Insert the central pipe into place and tighten the ring-nut to fix all parts.
Fig. 2
Fig.3
If your product is equipped with the DS device, the pack contains pipe B (TC40DS) instead of the ordinary pipe A (TC40), in which case the pipe B must be fitted as shown in figure 3, i.e. with the pipe projecting towards the rear of the rack, so that once it is inside the disinfector it will be aligned with the connection (illustration below).
A
B
-EN- LR4/DS -
19390300802-EN.doc 5 Rev. 01 - 30/07/2019
ILLUSTRATION
PROCEDURE
Fig. 4
Fit the differnet types of nozzles in the positions shown in the nozzle assembly diagram. Tighten the nozzles with the spanner provided.
Fig.6
When inserting the rack in the disinfector, the greatest care must be taken to ensure that the tapered connection on the rack is aligned with the one on the machine.
-EN- LR4/DS -
19390300802-EN.doc 6 Rev. 01 - 30/07/2019
5 USE AND PRECAUTIONS
PROCEDURE
PROCEDURE
Take care not to place pieces of glassware
touching each other.
Glass must not rest on the nozzle; it must stand on the base support, allowing the water to come out of the nozzle freely. Move the spring underneath the support to prevent it from descending.
Ensure that no glassware or any other item
for washing projects above the water intake.
Ensure that no item for washing projects from the rack after loading.
Smeg S.p.A.
Instruments Division
Via Leonardo da Vinci, 4 – 42016 Guastalla (RE) Italy
Tel. +39 0522 8211 - Fax + 0522 821 592
E-Mail: instruments@smeg.itwww.smeg-instruments.com
Loading...