INSTALLATION REQUIREMENTS
WD6010 – GW6010 – WD7010 – GW7010
INSTALLATION REQUIREMENTS
WD6010 – GW6010
WD7010 – GW7010
SMEG S.p.A. thank you for choosing this product.
Pre-installation operations (to be performed by the client):
room preparations (as needed)
pre-installation of properly operating systems, in compliance with the requirements and
regulations in force
positioning of the machine
Refer to this manual for detailed instructions on the steps mentioned above.
SMEG S.p.A. declines responsibility for damage to persons or property resulting from improperly
regulated or defective systems or for any installation of the appliance and/or accessories performed by
unauthorized personnel.
Any operation performed on the appliance by unauthorized personnel will invalidate the warranty.
New mod. exp. – new document layout: part 1 descriptive, part 2 schematic with specific code.
Added 7010 models and some value corrected
Specified installation environment conditions. Added RS232 and LAN in the scheme.
Specified cold water limits and added notes for the optional drain pump
Update: hydraulic and electric connection from the upper side, Except the models provided with heating tanks
(«boiler»). Improved prescription regarding supply water.
INSTALLATION REQUIREMENTS
WD6010 – GW6010 – WD7010 – GW7010
ELECTRICAL SYSTEM REQUIREMENTS
CAUTION
It is essential that the electrical system to which the machine is connected complies with current regulations.
All electrical testing operations and equipment installation should be made by qualified and trained personnel.
The designated personnel is responsible for ensuring the safety and efficiency of earth connection.
Components must always be replaced with genuine spare parts.
Refer to the Technical Data sheet to recognize the device’s electrical characteristics and connection requirements.
The device is supplied with a cable with insulated wire terminals; it is not supplied with a plug. The electrical connection of
the device must be carried out with a permanent connection.
CIRCUIT-BREAKER
A CIRCUIT-BREAKER must be installed for each appliance.
Circuit-breaker characteristics:
a. Omnipolar: must break all live conductors;
b. Easily accessible to the user;
c. Easily operated (no additional tools required);
d. Located in close proximity to the appliance;
e. Clearly marked as the appliance circuit-breaker
The same specifications apply to the main switch on the machine: it must be easily accessible. Do not place
objects in a way that limits accessibility.
A PROTECTIVE DEVICE specifically for the appliance (e.g. magneto thermal breaker or fuse on every phase, with
appropriate dimensions based on the electrical characteristics indicated) should be installed in the room’s
electrical panel.