SMC Networks ZSE80(F), ISE80(H) Operation Manual

No. PS##-OMM0003-A
PRODUCT NAME
Digital Pressure Switch
MODEL / Series / Product Number
ISE80(H)
-1-
PS##-OMM0003-A
Table of Contents
Safety Instructions 2
Model Indication and how to order 9
Summary of Product parts 10
Definition and terminology 11
Mounting and Installation 15
Installation 15
Piping 18
Wiring 19
Pressure Setting 21
Measurement mode 21
Setting of Function 23
Function selection mode 23
Default setting 23
F0 Unit conversion function 25
F1 Setting of OUT1 26
F2 Setting of OUT2 29
F3 Setting of response time 29
F4 Setting of analog output/auto-shift input 30
F5 Setting of display resolution 32
F7 Setting of fine adjustment of display value 33
F8 Setting of auto-preset 34
F9 Setting of power saving mode 36
F10 Setting of security code 37
Special function setting 38
F98 Setting of all functions 38
F99 Reset to the default setting 40
Other Settings 41
Maintenance 44
If the security code is forgotten 44
Troubleshooting 45
Specification 52
Specifications 52
Dimensions 54
-2-
PS##-OMM0003-A
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC)
*1)
and other safety regulations.
*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems
ISO 4413: Hydraulic fluid power -- General rules relating to systems IEC 60204-1: Safety of machinery -- Electrical equipment of machines (Part 1: General requirements) ISO 10218-1: Manipulating industrial robots -Safety. etc.
Caution :
CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Warning :
WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
Danger :
DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.
3. An application which could have negative effects on people, property, or animals requiring special safety analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.
-3-
PS##-OMM0003-A
Caution
The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Limited warranty and Disclaimer/Compliance Requirements
The product used is subject to the following "Limited warranty and Disclaimer" and "Compliance Requirements". Read and accept them before using the product.
Limited warranty and Disclaimer
1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.
2)
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products.
2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of weapons of mass
destruction (WMD) or any other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are governed by the
relevant security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.
-4-
PS##-OMM0003-A
Operator
This operation manual is intended for those who have knowledge of machinery using pneumatic
equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance.
Read and understand this operation manual carefully before assembling, operating or providing
maintenance to the product.
Safety Instructions
Warning
Do not disassemble, modify (including changing the printed circuit board) or repair.
An injury or failure can result.
Do not operate the product outside of the specifications.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not operate in an atmosphere containing flammable or explosive gases.
Fire or an explosion can result. This product is not designed to be explosion proof.
Do not use the product in a place where static electricity is a problem.
Otherwise it can cause failure or malfunction of the system.
If using the product in an interlocking circuit:
Provide a double interlocking system, for example a mechanical system
Check the product regularly for proper operation
Otherwise malfunction can result, causing an accident.
The following instructions must be followed during maintenance:
Turn off the power supply
Stop the air supply, exhaust the residual pressure and verify that the air is released before performing
maintenance
Otherwise an injury can result.
Caution
Do not touch the terminals and connectors while the power is on.
Otherwise electric shock, malfunction or damage to the product can result.
After maintenance is complete, perform appropriate functional inspections and leak tests.
Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurred from other parts except piping, the product might break. Cut off power supply and stop supplying fluid. Do not apply fluid at leaking condition. Safety cannot be assured in the case of unexpected malfunction.
Use ferule made by Swagelock® (trade name: Swagelock® fittings) for TSJ fittings, packing and glands
made by Cajon (trade name: Cajon VCR
®
fittings) for URJ fittings.
Otherwise safety may not be secured due to leakage from joint. When using ferules, packing or glands made by other manufacture, be sure to perform helium leak test to verify no leakage.
-5-
PS##-OMM0003-A
NOTE
Follow the instructions given below when designing, selecting and handling the product.
The instructions on design and selection (installation, wiring, environment, adjustment,
operation, maintenance, etc.) described below must also be followed.
Product specifications
The direct current power supply to combine should be UL approved as follows.
Circuit (of Class2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class2 power supply unit or UL1585 Class2 transformer.
The Pressure switch is a approved product only if it has a mark on the body.
Use the specified voltage.
Otherwise failure or malfunction can result.
Do not exceed the specified maximum allowable load.
Otherwise it can cause damage or shorten the lifetime of the Pressure switch.
Design the product to prevent reverse current when the circuit is opened or the product is forced to operate for
operational check. Reverse current can cause malfunction or damage to the product.
Input data to the Pressure switch is not deleted, even if the power supply is cut off. (Writing time: 1,000,000 times, Data duration: 10 years after power off)
Applicable fluid is a fluid that does not corrode SUS630 and SUS304.
Do not use a fluid containing chemicals, synthetic oils including organic solvent, salt and corrosive gases. Otherwise, damage to the product and malfunction can result.
Check the details of the specifications before using.
Use the specified measurement flow rate and operating pressure.
Otherwise it can cause damage to the Pressure switch or inability to measure correctly.
Reserve a space for maintenance.
Allow sufficient space for maintenance when designing the system.
-6-
PS##-OMM0003-A
Product handling
Installation
Tighten to the specified tightening torque.
If the tightening torque is exceeded the mounting screws and brackets may be broken. If the tightening torque is insufficient, the product can be displaced and loosen the mounting screws. (Refer to "Mounting and Installation" on page 15.)
Do not apply excessive stress to the product when it is mounted with a panel mount.
Otherwise damage to the product and disconnection from the panel mount can result.
Be sure to ground terminal FG when using a commercially available switch-mode power supply.
Do not drop, hit or apply shock to the Pressure switch.
Otherwise damage to the internal parts can result, causing malfunction.
Do not pull the lead wire forcefully, not lift the product by pulling the lead wire. (Tensile force 49N or less)
Hold the body when handling to avoid the damage of the Pressure switch which lead to cause the failure and malfunction.
For piping of the Pressure switch, hold the piping with a spanner on the metal part of the piping (Piping attachment).
Holding other part with spanner leads to damage the Pressure switch.
Eliminate any dust left in the piping by air blow before connecting the piping to the product.
Otherwise it can cause damage or malfunction.
Do not insert metal wires or other foreign matter into the pressure measurement port.
It can damage the pressure sensor causing failure or malfunction.
Never mount a product in a location that will be used as a foothold.
The product may be damaged if excessive force is applied by stepping or climbing onto it.
If the entering of foreign material to the fluid is possible, install and pipe the filter or the mist separator to the inlet to avoid failure and malfunction.
Wiring
Do not pull the lead wires.
In particular, never lift a Pressure switch equipped with fitting and piping by holding the lead wires. Otherwise damage to the internal parts can result, causing malfunction or to be off the connector.
Avoid repeatedly bending or stretching the lead wire, or placing heavy load on them.
Repetitive bending stress or tensile stress can cause the sheath of the wire to peel off, or breakage of the wire. If the lead wire can move, fix it near the body of the product. The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one.
Wire correctly.
Incorrect wiring can break the Pressure switch.
Do not perform wiring while the power is on.
Otherwise damage to the internal parts can result, causing malfunction.
Do not route wires and cables together with power or high voltage cables.
Otherwise the product can malfunction due to interference of noise and surge voltage from power and high voltage cables to the signal line. Route the wires (piping) of the product separately from power or high voltage cables.
Confirm proper insulation of wiring.
Poor insulation (interference from another circuit, poor insulation between terminals, etc.) can lead to excess voltage or current being applied to the product, causing damage.
Design the system to prevent reverse current when the product is forced to operate for operational check.
Depending on the circuit used, insulation may not be maintained when operation is forced, allowing reverse current to flow, which can cause malfunction and damage the product.
Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage.
Do not use a cable longer than 10m. Wire the DC (-) line (blue) as close as possible to the power supply.
When analog output is used, install a noise filter (line noise filter, ferrite element, etc.) between the switch-mode power supply and this product.
-7-
PS##-OMM0003-A
Environment
Do not use the product in an environment that is constantly exposed to the splash of water.
Otherwise failure or malfunction can result. Take measures such as using a cover.
Do not use the product in an environment where corrosive gases or fluids could be splashed.
Otherwise damage to the product and malfunction can result.
Do not use in a place where the product could be splashed by oil or chemicals.
If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires)
Do not use in an area where surges are generated.
If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction furnace, motor, etc.) close to the Pressure switch, this may cause deterioration or breakage of the internal circuit of the Pressure switch. Avoid sources of surge generation and crossed lines.
Do not use a load which generates surge voltage.
When a surge-generating load such as a relay or solenoid is driven directly, use a Pressure switch with a built-in surge absorbing element.
The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in the system.
Mount the product in a place that is not exposed to vibration or impact.
Otherwise failure or malfunction can result.
Prevent foreign matter such as remnant of wires from entering the Pressure switch.
Take proper measures for the remnant not to enter the Pressure switch in order to prevent failure or malfunction.
Do not use the product in an environment that is exposed to temperature cycle.
Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product.
Do not expose the product to direct sunlight.
If using in a location directly exposed to sunlight, shade the product from the sunlight. Otherwise failure or malfunction can result.
Keep within the specified fluid and ambient temperatures range.
The fluid and ambient temperatures is 5 to 50 oC. Operation under low temperature (5 oC or less) leads to cause damage or operation failure due to frozen moist in the fluid or air. Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water. Avoid sudden temperature change even within specified temperature.
Do not operate close to a heat source, or in a location exposed to radiant heat.
Otherwise malfunction can result.
Use operating fluid which does not corrode the part in contact with fluid which is made of SUS630 (for sensing part) or SUS304 (for fitting part). (Compatibility between fluid and material can be checked by contact to fluid supplier.)
Adjustment and Operation
Turn the power on after connecting a load.
Otherwise it can cause excess current causing instantaneous breakage of the Pressure switch.
Do not short-circuit the load.
Although error is displayed when the Pressure switch load is short circuit, generated excess current lead to cause the damage of the Pressure switch.
Do not press the setting buttons with a sharp pointed object.
It may damage the setting buttons.
If using the product to detect very small pressure rates, warm up the product for 10 to 15 minutes first.
There will be a drift on the display and the analog output of approximate 1% immediately after the power supply is turned on.
Perform settings suitable for the operating conditions.
Incorrect setting can cause operation failure. For details of each setting, refer to page 21 to 43 of this manual.
The Pressure switch is compulsory turned off for 4 seconds after power supplied. For 4 seconds after supplying power, the measurement output is turned off.
Do not touch the LCD during operation.
The display can vary due to static electricity.
-8-
PS##-OMM0003-A
Maintenance
Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of
air before performing maintenance.
There is a risk of unexpected malfunction.
Perform regular maintenance and inspections.
There is a risk of unexpected malfunction.
Perform drainage regularly.
If condensate enters the secondary side, it can cause operating failure of pneumatic equipment.
Do not use solvents such as benzene, thinner etc. to clean the Pressure switch.
They could damage the surface of the body and erase the markings on the body. Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the stains again with a dry cloth.
Other
If there is a possibility of water or drainage getting in, narrow the diameter of the piping to the Pressure
switch, or make an orifice in the middle of the piping.
Although this Pressure switch uses stainless diaphragm pressure sensor which is not damaged by water, the drain contained in the air or water during vacuum release after confirming vacuuming collides with the pressure sensor and the inertia force of water or air containing the drain can damage the pressure sensor, and correct display of the pressure may not be available. Extra attention is needed when the rear surface piping type is used.
The use of a resin piping can cause static electricity depending on the fluid. Therefore, when connecting the Pressure switch, take appropriate measures against static electricity and separate the grounding for the Pressure switch from the grounding for other equipment which may generate a strong electromagnetic noise or high frequency. Otherwise, static electricity may damage the Pressure switch.
-9-
PS##-OMM0003-A
Model Indication and how to order
Option/Part number
Description Piping direction Part number
ZS-24-A
Rear surface piping
ZS-24-D
Bracket
Bottom piping ZS-35-A
Rear surface piping ZS-35-C
Panel mount adapter
Bottom piping ZS-35-B
Rear surface piping ZS-35-F
Panel mount adapter + Front protective cover
Bottom piping ZS-35-E
-10-
PS##-OMM0003-A
Names and Functions of Product
Names of individual parts
Indication light (Orange light): Displays switch operation condition.
LCD display: Displays the current status of pressure, setting mode, selected indication unit and error code.
Four display modes can be selected: display always in red or green only, or changing from green to red linked to output.
button (UP): Selects the mode or increases ON/OFF set value.
Press this button to change to the peak display mode.
button (DOWN): Selects the mode or decreases ON/OFF set value.
Press this button to change to the bottom display mode.
button (SET): Press this button to change to either mode and to set a set value.
-11-
PS##-OMM0003-A
Definition and terminology
Terms Meaning
2
2-color indication
There are two colors to indicate a value, changing in accordance with ON and OFF of the switch output.
7
7-segment indication
When "8" is shown on the display. It is called 7-segment because 8 consists of 7 pieces of "- (segments)".
(Analog) current output See "Analog output (function)".
Analog output (function) Function to output the voltage in proportion to the pressure.
(Analog) voltage output See "Analog output (function)".
Auto preset
A function of the Pressure switch to automatically setup pressure just by having equipment hold and release a workpiece via vacuum adsorption. This function is used in an application where vacuum adsorption of a workpiece needs to be confirmed with a Pressure switch.
A
Auto shift
A function to correct the set value of the switch output in accordance with the applied pressure in case the switch operation is unstable due to pulsation of applied pressure. This function is used in applications such as vacuum adsorption. The pressure when a signal is externally input is set as a reference value with which the pressure that turns the switch on or off can be shifted.
B
Bottom value indication (mode) Shows the minimum pressure reached at that moment.
Chattering
The phenomenon caused in the switch output type in which the output turns on and off repeatedly at high frequency.
C
Chattering-preventing function
A function to delay the response time of switch output in order to prevent chattering.
D
Digit (Min. setting unit)
Shows how precisely the pressure can be indicated or set by the digital Pressure switch. When 1 digit = 1 kPa, the pressure is given with an increment of 1 kPa, e.g., 1, 2, 3, …, 99, 100.
E
Error indication
With the self-diagnosis function given to the Pressure switch, it indicates that there is a failure which could cause a switch failure.
Fine adjustment mode See "Fine adjustment of indicated value".
Fine adjustment of indicated value (function)
An indicated pressure value can be adjusted within the range of ±5% R.D. (±5% of the indicated value). It is used if a true pressure value is known or to correct the difference of an indicated value of the measurement equipment nearby that measures the same pressure as the Pressure switch.
F.S. (full span/full scale)
Abbreviation for full span and full scale; means the maximum fluctuation range of the Pressure switch rated value. For example, when the output voltage is 1 to 5[V], the F.S. will be 5-1 = 4[V]. (Reference: 1%F.S. = 4 × 0.01 = 0.04[V])
F
Function selection mode
It is a mode with which each function is set up, and it is a separate menu from the pressure setup. If the setting needs to be changed at factory, "F∗", each item can be set up. The items to be set up are: indication color, operation mode, output type, response time, indication resolution, fine adjustment of indicated value, use of auto preset, use of power-saving mode, and use of PIN number. (Refer to "Function selection mode" on page 23.)
-12-
PS##-OMM0003-A
Terms Meaning
Hysteresis Difference between the points at which the Pressure switch is turned on and off.
H
Hysteresis mode Refer to "List of output mode" on page 28.
Indication accuracy Shows the deviation between displayed pressure value and the true pressure.
Indication color
The color of the digital display. There are four choices: usually green, usually red, green (off) to red (on), and red (off) to green (on).
Indication light The light that turns on when the switch output is on.
Insulation resistance
Insulation resistance of a product itself. The resistance between an electric circuit and a body.
Indication resolution
How fine the rated pressure range can be segmented. (Example: If a product for 0 to 1 MPa can indicate pressure by 0.001 MPa, the indication resolution is 1/1000.)
Indication unit The unit of pressure used in the display.
I
Internal voltage drop See "Residual voltage".
K
Key lock (function) Prohibits a change in the setting of the Pressure switch (locks button operation).
L
Load impedance See "Max. load impedance".
Manual setup
Manual pressure setup without using auto preset. This term is used to discriminate from the pressure setup using auto preset.
Max. applied voltage
The maximum value of applied voltage available to the output line of the NPN output.
Max. load current The maximum current available to the output (output line) of the switch output.
Max. (Min.) load impedance
The maximum load (resistance value and impedance) which can be connected to the output (output line) of the analog current output.
Measurement mode
The condition in which the pressure is being detected and indicated and switch operation is enabled. (Refer to "Measurement mode" on page 21.)
M
Min. setting unit Refer to "digit".
Normal output
One of the switch output types, and means the operation in which a switch is turned on when pressure equal to the switch output set value or more is detected. In the (hysteresis mode) window comparator mode, it indicates the operation in which a switch is turned on when pressure in the switch output range (P1L to P1H or P2L to P2H) is detected. (Refer to "List of output mode" on page 28.)
N
NPN (open collector) (output) The switch that uses the NPN transistor for output.
-13-
PS##-OMM0003-A
Terms Meaning
Operating mode There are two choices, hysteresis mode and window comparator mode.
Orifice A restriction.
Output impedance
The resistance value of a component between the voltage outputting element and the output line at the output of the analog voltage output. It is indicated as a resistance value which is converted in accordance with the condition in which resistance is directly connected to the voltage output element. There may be an error in the output voltage depending on this output impedance and the input impedance of customers' equipment. (Example: If the Pressure switch with output impedance of 1 k is connected to the A/D converter to detect the analog output of 5V, the detected voltage by the A/D converter becomes 5(V) × 1(MΩ)/
(1(k) + 1(M)) ≒ 4.995(V), and there is an error of approximate 0.005 V.)
O
Output style
The operation theory of the switch output. Either normal output or reversed output can be selected. Refer to "List of output mode" on page 28 for the operation status.
Peak value indication (mode) Shows the maximum pressure reached at that moment.
Piping-port size
The size of the port on the switch body with which a device and the switch are connected.
PNP (open collector) (output) The switch that uses the PNP transistor for output.
Power saving mode
The condition in which the indicated value turns off and current consumption is reduced.
Pressure-sensing part A pressure-detecting part of a pressure-detecting element.
Pressure setting
The setting of pressure to determine the point at which the Pressure switch turns on and off.
P
Proof pressure The pressure beyond which the Pressure switch breaks.
Rated pressure range
The pressure range in which the Pressure switch satisfies the specifications. Values over this range can be set if they are within the set pressure range, but cannot assured the specifications to be satisfied.
Repeatability
Reproducibility of the displayed value for pressure and ON-OFF output operating point when the pressure changes at a temperature of 25
o
C.
Residual voltage
The difference between the ideal ON voltage and the actual voltage when the switch output is on. It depends on present load current and ideally should be "0".
Resolution See "Indication resolution".
Response time
The elapsed time until the ON-OFF output begins working since the pressure supplied for the Pressure switch has reached the set value. Generally, the shorter response time is, the better the performance is.
Reversed output
One of the switch output types, and means the operation in which a switch is turned on when pressure equal to the switch output set value or less is detected. In the (hysteresis mode) window comparator mode, it indicates the operation in which a switch is turned on when pressure outside the switch output range (n1L to n1H or n2L to n2H) is detected. (Refer to "List of output mode" on page 28.)
R
Ripple A type of chattering.
-14-
PS##-OMM0003-A
Terms Meaning
Sampling cycle
The frequency in which the detected pressure should be reflected to the digital indication.
Setting of function See "Function selection mode".
Setting pressure range The pressure range within which switch output can be set.
Stainless steel diaphragm
A stainless steel pressure-detecting part of the pressure-detecting element. It is suitable for measuring fluid such as water.
S
Switch output Alternatively called "ON-OFF output".
T
TSJ fitting
Abbreviation for Tube Swage Joint. The recommended fitting is Swagelok fitting made by Swagelok.
URJ fitting
Abbreviation for Union Ring Joint. The recommended fitting is VCR fitting made by Swagelok.
U
Unit conversion function
Function to change the unit in which the value of pressure is indicated. Only a product with this function can change the unit. A product with unit-changing function cannot be purchased if it is used within Japan. Pressure is indicated only by SI units in Japan.
Wetted part (or part exposed to gas)
That part of the Pressure switch which is in contact with detected fluid such as a pressure sensor, seal, and fitting.
Window comparator mode
An output type that holds the output when the pressure is within a certain range. (Refer to "List of output mode" on page 28.)
W
Withstand voltage
Durability to voltage applied between an electric circuit and a body. A product's durability in withstanding voltage. If more voltage is applied to the product, the product may be broken. (Voltage mentioned here is not power voltage to activate the product.)
Z
Zero clear (function) Adjusts the displayed pressure value to "0".
-15-
PS##-OMM0003-A
Mounting and Installation
Installation
Mounting
Mount the optional bracket and panel mount adapter to the Pressure switch.
When the Pressure switch is to be mounted in a place where water and dust splashes occur, insert a tube
(O.D φ4, I.D φ2.5) into the air-relieving port of the Pressure switch.
Mounting by bracket
Fix the bracket to the Pressure switch with the set screws M3×5L (2 pcs.) supplied.
Apply a tightening torque of 0.98 Nm or less.
<Rear piping>
<Bottom piping>
-16-
PS##-OMM0003-A
Mounting with panel mount adapter
<Rear piping>
<Bottom piping>
-17-
PS##-OMM0003-A
Panel cutout dimension
Options
Panel mount adapter (Panel mount adapter A and B included)
Model: ZS-35-B (Bottom piping)
ZS-35-C (Rear piping)
Panel mount adapter + Front protective cover
Model: ZS-35-E (Bottom piping)
ZS-35-F (Rear piping)
: Panel thickness 1.0 to 5.0 mm
: Panel thickness 1.0 to 5.0 mm
-18-
PS##-OMM0003-A
Piping
Mounting by screw type piping
Connect suitable piping with mating port.
In order to connect the hexagon socket head plug or fitting on the pressure port, hold the hexagon part of
the pressure port and fix. Apply a tightening torque of 13.6 Nm or less.
Tube attachment
When this Pressure switch is used in a place where water and dust splash on, insert a tube in the
air-relieving port, and bring piping of the opposite side up to the safe position to keep it from water and dust. (See the figure below.)
<Rear piping>
<Bottom piping>
: The tube should be inserted to the end of the air-relieving port.
: SMC TU0425 (polyurethane, O.D φ4, I.D φ2.5) suits to the Pressure switch.
Loading...
+ 42 hidden pages