SMC Networks TigerSwitch series, TigerSwitch SMC6624GSSC, TigerSwitch SMC6624GT, TigerSwitch SMC6624GLSC, TigerSwitch SMC6624FMSC Installation Manual

1
SMC TigerSwitch Modules Installation Guide
Introduction
The SMC TigerSwitch modules can be installed into the SMC6624M switch to provide 100 Mbps and 1000 Mbps connections to other compatible network devices.
Use these modules for the following network connectivity:
1000BASE-SX module—1000 Mbps operation over multimode fiber-
optic cable
1000BASE-LX module—1000 Mbps operation over either single-
mode or multimode fiber-optic cable
100/1000BASE-T module—1000 or 100 Mbps operation over Cate-
gory 5 or better unshielded twisted-pair (UTP) or shielded twisted­pair (STP) cables
100BASE-FX SC module—100 Mbps operation over multimode
fiber-optic cable
For more information on the cables used with these modules and the supported cable lengths, see page 4.
1000BASE-SX-SC
TX RX
SMC6624GSSC
1000BASE-LX-SC
TX RX
SMC6624GLSC
100BASE-FX-SC MMF
TX RX
SMC6624FMSC
100/1000BASE-T
SMC6624GT
SMC6624GSSC 1000BASE-SX module
SMC6624GLSC 1000BASE-LX module
SMC6624GT 100/1000BASE-T module
SMC6624FMSC 100BASE-FX module
2
Installation Steps
To install the SMC TigerSwitch modules, follow these steps:
1. Insert the module into an SMC6624M module slot and secure the retaining screws.
2. Reset or reboot the SMC6624M switch.
3. Connect the network cable to the module and check the module and network device for correct operation.
Details on these steps are provided in the rest of this document.
Installation Notes
Please read these notes before proceeding.
The SMC TigerSwitch modules are supported in the SMC
TigerSwitch 10/100 SMC6624M switch only. Do not try to install the modules in any other SMC TigerSwitch devices.
It is not necessary to turn off power to the SMC6624M switch before
installing a module into it. You can install a module while the switch is powered on, but you must reset or reboot the switch after installing the module to initialize and activate it.
Please see the TigerSwitch 10/100 SMC6624M Installation Guide for more information on installing the modules.
3
Insert the Module into the Slot
The modules are installed into the SMC6624M switch as follows:
1. Using a flat-bladed or Torx T-10 screwdriver, unscrew the two retaining screws on the slot cover plate or existing module, and remove it from the switch.
2. Touch a grounded, metal object (such as a powered-on switch) to discharge any static electricity on your body, then carefully remove the module from its protective anti-static packaging. Hold the module by its bulkhead or edges, taking care not touch any of its board components or metal connectors.
3. Slide the module firmly into the module slot as far as it will go. The module should “snap” into place, and the module’s faceplate should touch the front panel of the switch. The following illustration shows the module being installed into the SMC6624M switch.
4. Using the flat-bladed or Torx T-10 screwdriver, tighten the retaining screws on the module until they are secure, but be careful that you do
not overtighten the screws.
5. Reset the switch to initialize the module.
1
7
25
26
25 26
1 2 3 4 5 6 13 14 15 16 17 18
789101112192021222324
Clear
Reset
Self Test
Fan
Status
Link
Act
Link
Act
Console
Power
Fault
loosen these screws and remove the cover plate
25
25 26
1 2 3 4 5 6 13 14 15 16 17 18
789101112192021222324
Clear
Reset
Self Test
Fan
Status
Link
Act
Link
Act
1000BASE-SX-SC
TX RX
SMC6624GSSC
slide the module into the slot until it snaps into place
4
Connect Network Cables to the Module Port
The network cables identified in the table below should be used with the SMC TigerSwitch modules.
Port Type Cable Type Length Limits
Fiber-Optic Cables
1000BASE-SX 62.5/125 µm or 50/125 µm core/
cladding diameter, graded-index, multimode fiber-optic cables that are fitted with SC connectors—the cables must comply with the ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a standards.
•62.5 µm cable: – 160 MHz*km = 220 meters – 200 MHz*km = 275 meters
•50 µm cable: – 400 MHz*km = 500 meters – 500 MHz*km = 550 meters
1000BASE-LX single-mode cables fitted with SC
connectors—the cables must comply with the ITU-T G.652 and ISO/IEC 793-2 Type B1 standards.
The multimode cables specified for the 1000BASE-SX module may also be used, but a mode conditioning patch cord may be needed — see “Mode Conditioning Patch Cord” on page 8 for more information.
• single-mode cable - 5 kilometers
• multimode cable - 550 meters
100BASE-FX 62.5/125 µm or 50/125 µm core/
cladding diameter, graded-index, multimode fiber-optic cables that are fitted with SC connectors—the cables must comply with the ITU-T G.651 and ISO/IEC 793-2 Type A1b or A1a standards.
• 2 kilometers for full-duplex
connections
• 412 meters for half-duplex
connections Note: The SMC6624M switch does
not support half-duplex operation for the modules.
Twisted-Pair Cables
100/ 1000BASE-T
Category 5 or better, 100-ohm UTP or STP balanced cable. For 1000 Mbps (Gigabit) operation, Category 5E cabling or better is recommended.
Note: For 1000 Mbps operation, all four wire pairs are used for data transmissions.
100 meters Note: The 100/1000BASE-T module
is compatible with the IEEE 802.3ab standard including the “Auto MDI/ MDI-X” feature, which allows you to use either straight-through or crossover twisted-pair cables for connection go any network device including end nodes, such as computers, or to other switches, hubs, and routers.
Loading...