4 Select a Coverage Pattern
A. If the SMCMT01-Z is closed, use a flat head screwdriver
to press the back cover tabs
to release the back cover.
B. If necessary, modify the coverage pattern as follows:
Plastic mask method: Use one or both supplied plastic
masks to mask off large areas of coverage.
Adhesive label method: Mask the appropriate mirror
curtains with the supplied adhesive labels
. Do not use
sharp objects to remove unwanted labels, as the mirror
can get scratched. If necessary, peel off the label.
Cardboard mask method: Use the cardboard undercrawl
window mask. The undercrawl mask allows objects to be
placed within 5 feet (1.5 m) of, or directly below, the
SMCMT01-Z. If the mask will not be used, remove it.
5 Perform the Walk Test
To test the SMCTM01-Z operation and coverage pattern.
A. If the SMCMT01-Z is closed, use a flat head screwdriver
to press the back cover tabs to release the back cover.
B. Open the tamper switch to enable the Walk Test.
C. Press the front cover release tab to remove the front
cover to access the Transmitter and PIR circuit boards.
D. When the SMCMT01-Z is remounted on the bracket, the
Walk Test is enabled for 3-4 minutes. If more time is
required, press and release the tamper switch to reset
the Walk Test timer. Depending on switch settings (see
step 2), the Walk Test triggers an alarm when 1 or 2
curtain areas are entered and the LED on the front cover
goes ON to indicate an alarm.
E. Walk test the detection pattern and make any necessary
adjustments.
F. Replace and walk test the SMCMT01-Z to verify that it is
communicating with the control panel.
Note: When the test ends (3-4 minutes), the SMCMT01-Z
returns to normal mode, where it activates once every 3
minutes and the LED goes OFF to reduce battery drain.
6 Mount the SMCMT01-Z
Before touching the SMCMT01-Z, touch a grounded, bare
metal surface to remove static electricity or wear a
grounding strap.
A. Mount the SMCMT01-Z from 7 to 10 feet (2.1 to 3.0 m)
high. For optimum detection and pet immunity, mount it
between 7 and 8 feet (2.1 and 2.4 m) high.
For pet alley applications, mount the SMCMT01-Z 3 feet
(0.9 m) above the floor, upside down, with the detector
window toward the ceiling. Use the standard mirror and
set the SENS jumper for increased sensitivity.
B. Mount the SMCMT01-Z on a rigid vibration-free surface,
where it can detect the movements of an intruder.
C. Avoid surfaces exposed to moisture and areas that can
expose the SMCMT01-Z to false alarm sources such as:
Direct sunlight
Heaters and radiators in the field of view
Strong air drafts (fans, air conditioners, etc.)
D.
Avoid areas where the ambient temperature is below
0° F (-18°C) or above 122°F (50°C).
E. Do not aim the SMCMT01-Z at windows or glass doors.
To mount the SMCT01-Z:
A. Touch a grounded, bare metal surface to remove static
electricity from your body or wear a grounding strap.
B.
Separate the PIR unit from the mounting bracket (see
the figure on the previous page).