SMC Networks SMCDW01Z User Manual

1
SMC
DW
01
-
Z
Door
-
Window
Sensor Quick Start Guide
continued on next page
Key Components
D.
Find the supplied CR2 3-volt lithium battery.
E.
Find the tamper switch.
F.
While pressing and holding the tamper switch, insert the battery into the SMCDW01-Z, with the positive (+) end oriented towards the tamper switch. The front panel LED goes ON.
G.
After 1 second, release the tamper switch. The LED blinks green.
H.
Replace the SMCDW01-Z back plate.
I.
Align the magnet next to the SMCDW01-Z. The SMCDW01-Z can now be added to the SMA Gateway.
Note: Do not physically mount the SMCDW01-Z until you
add it to the SMA.
B.
Wipe clean the surface where the SMCDW01-Z will be mounted. Dust and particles can reduce the adhesion of double-sided mounting tape you will use to mount the SMCDW01-Z.
C.
Place the main sensor unit and magnet unit in such a way that when the door or window is closed, the man sensor unit and magnet unit are within 2cm. from each other. When you open the door or window, these two units should separate in proximity.
Note: For optimal radio communications, position the
SMCDW01-Z vertically against the door/window frame.
3
2
A. B. C.
Copyright ©2010 SMC Networks
Insert the Battery
Find the locking mechanism on the bottom of the SMCDW01-Z.
Holding the SMCDW01-Z in one hand, carefully insert the tip of a screwdriver into the locking mechanism.
Push lightly upwards from the back of the SMCDW01-Z until the back plate separates from the sensor.
I/M SMCDW01-Z rev. 1.0 8/24/10
To mount the SMCDW01-Z to a wall, door, or window frame, use double-sided mounting tape:
A.
Mounting the SMCDW01-Z
Identify the locations on the SMCDW01-Z where double­sided mounting tape can be applied.
All Rights Reserved
Page 1
D.
continued on next page
Do not mount the SMCDW01-Z directly on or near metal framing or other large metallic objects, which can weaken transmitted radio signal.
E.
Place the SMCDW01-Z indoors and away from sources of water/moisture and other extreme weather conditions.
F.
Either screw the bidirectional mounting plate and magnet unit into the wall, door or window frame. Use the supplied screw anchors if attaching the SMCDW01-Z to soft material, such as drywall.
AND/OR
Peel and attach the double-sided mounting tape to the back of the bidirectional mounting plate and magnet unit to adhere to the wall, door, or window frame.
4
A. A.
B.
C. D. E.
Add the SMCDW01-Z to the SMA
From the Home screen, touch the Settings widget.
When the Keypad screen appears, touch the numbers to enter your keypad code.
When the Settings menu appears, use the keypad to enter the Installer Code (this code is the same for all SMA Gateways installed by your company).
When the Technician keyboard pad appears, enter your Technician ID and touch Done.
When the Technician Settings menu appears, select Sensors & Zones > Add a Sensor/Zone.
When the Add a sensor screen appears, use the Arrow buttons to select the number of sensors you want to add.
SMCDW01-Z Door-Window Sensor Quick Start Guide
F.
Click Next. The Locating Sensors screen appears and the system scans the premises for wireless sensors that can be added, which must meet the following requirements:
-
Defaulted
-
Not currently paired with another SMA Gateway device
G.
Follow the system prompts to complete the add process.
Note: If no available sensors are found or fewer are found
than expected:
-
Touch Cancel Sensor/Zone Add to return to the Technician Settings menu.
-
Touch Back to return to Add a Sensor screen.
H.
Check the signal strength between the SMCDW01-Z and SMA Gateway (see “Test Signal Strength,” below.
I.
Mount the sensor to a door or window.
If you encounter a problem, see Step 7, “Troubleshooting.”
Note: The SMCDW01-Z uses one CR2, 3-volt lithium
battery. After you add it to the SMA system, it checks its battery conditions automatically and reports the conditions to the SMA Gateway. The SMA Gateway issues an alert if the battery must be replaced.
5
After adding the SMCDW01-Z to the SMA Gateway, test the signal strength between the SMA Gateway and its added sensors/security zones:
A. B. C.
The Sensor Diagnostic for <Security Zone name> appears as the system detects the current signal strength between the selected sensor and the SMA Gateway.
6
To view event history:
A. B. C.
Test Signal Strength
Perform steps A through D in step 2, “Add the SMCDW01­Z to the SMA.”
When the Technician Settings menu appears, select Sensors & Zones > Sensor Diagnostics.
When the currently installed sensors/security zones appear, touch the zone you want to test for connectivity and follow the instructions from the SMA Gateway.
4B
View Zone Event History
Touch the Security widget on the Home screen.
When the Dashboard appears, touch the History tab.
The Zone Event History shows the event history.
I/M SMCDW01-Z rev. 1.0
Copyright ©2010 SMC Networks
Page 2
All Rights Reserved