SMC Networks PF2A3 Series, PF2W3 Series, PF2D3 Series Operation Manual

Flow Monitor
Operation Manual
PF2A3 /PF2W3 /PF2D3
Installation
•Never mount the product in a location that will be used as a foothold.
Thank you for purchasing an SMC PF2A3 /PF2W3 /PF2D3 Series Flow Monitor. Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep this manual handy for future reference.
To obtain more detailed information about operating this product, please refer to the SMC website (URL http://www. smcworld.c om
) or contac t SMC
directly.
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) and other safety regulations.
CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Operator
This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are a
llowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
Caution:
Warning:
Danger:
WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Safety Instructions
Do not disassemble, modify (including changing the printed circuit board) or repair.
An injury or failure can result.
Do not operate in an atmosphere containing flammable, explosive or corrosive gas.
Fire or an explosion can result. This product is not designed to be explosion proof.
Do not touch the piping or its connected parts when the fluid is at high temperature.
It may lead to burnt. Ensure the piping cools sufficiently before touching.
Do not use the product in a place where static electricity is a problem.
Otherwise it can cause failure or malfunction of the system.
If using the product in an interlocking circuit:
•Provide a double interlocking system, for example a mechanical system
•Check the product regularly for proper operation
Otherwise malfunction can result, causing an accident.
The following instructions must be followed during maintenance:
•Turn off the power supply
•Ensure the flow is shut off before performing maintenance
Otherwise an injury can result.
After maintenance is complete, perform appropriate functional inspections and leak tests.
Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurs from parts other than the piping, the product might be faulty. Disconnect the power supply and stop the fluid supply. Do not apply fluid under leaking conditions. Safety cannot be assured in the case of unexpected malfunction.
Do not touch the terminals and connectors while the power is on.
Otherwise electric shock, malfunction or damage to the product can result.
D
o not operate the product outside of the specifications.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Warning
Caution
Maintenance
How to reset the product after a power cut or forcible de-energizing
The setting of the product will be retained as it was before a power cut or de-energizing. The output condition is also basically recovered to that before a power cut or de-energizing, but may change depending on the operating environment. Therefore, check the safety of the whole installation before operating the product.
Summary of Product parts
Mounting and Installation
Indicator LED (OUT1)
b
utton (UP)
LED display
Panel mount adapter
b
utton (SET)
Indicator LED (OUT2)
button (DOWN)
Indicator LED
Item
Installing Removing the panel mount adapter
•Remove the panel mount adapter from the product if it has been delivered assembled.
•Remove the mounting bracket using a flat blade screwdriver.
Hook
•Lever the hook to the outside to remove the adapter (See below).
•If the panel mount adapter is pulled with the hook engaged, the product or the panel mount adapter will be damaged.
Front
Description
Terminal block
T
erminals to connect the power, output and sensor wires.
Fordetails, refer to Wiring.
Terminal block
Item
Back
Description
LED display
Displays the flow value, setting mode, and error indication.
Indicator LED
I
ndicates the reference condition selected. LED is ON (Red) when normal condition is selected. (Only the PF2A3 )
P
anel mount adapter
Adapter to mount the product to the panel.
Indicator LED (OUT1)
Indicates the output status of OUT1. LED is ON (Green) when OUT1 is ON. The LED flashes when an over current error occurs. W
hen the accumulated pulse output mode is selected, the indicator LED will turn OFF.
Indicator LED (OUT2)
I
ndicates the output status of OUT2. LED is ON (Red) when OUT2 is ON. T
he LED flashes when an over current error occurs.
When the accumulated pulse output mode is selected, the indicator LED will turn OFF.
button (UP)
Selects the mode or increases the ON/OFF Set value.
button (SET)
Press this button to change to another mode and to set a value.
button (DOWN)
Selects the mode or decreases the ON/OFF Set value.
+
PF2A30 series
PF2A550PF2A510
P
F2W511
PF2D520 PF2D540PF2D504
Connected sensor
Display instantaneous flow
Display
accumulated flow
2 sec.
2 sec. or longer
Display mode
Display
accumulated flow
Display
instantaneous flow
3 sec. or longer
3 sec. or longer
I
nput the Set value of instantaneous output
(Auto-preset)
I
nput the Set value of accumulated output
I
nput the Set value of instantaneous output
Input of the Set point 1
(OUT1)
Input of the Set point 2
(OUT1)
Input of the Set point 3
(OUT2)
Measurement of the
Set value (OUT1)
Input of the Set value for the
lower 3 digits (OUT1)
I
nput of the Set value for the
u
pper 3 digits (OUT1)
Input of the Set value for the
lower 3 digits (OUT2)
Input of the Set value for the
upper 3 digits (OUT2)
Function selection mode
Measurement of the
Set value (OUT2)
F
low
Set value is calculated and set.
Flow
Set value is calculated and set.
Display instantaneous flow
Display accumulated flow
D
isplay accumulated flow
Accumulated value is reset
Display instantaneous flow
Display upper 3 digits
Accumulated output mode
Accumulated pulse
output mode
Instantaneous
output mode
Output mode (OUT1)
Accumulated output mode
Accumulated pulse
output mode
Instantaneous
output mode
Output mode (OUT2)
Unit selection function
1
L/min,L
Non-Reverse
output
Reverse
output
Switch operation (OUT2)
Non-Reverse
output
Reverse
output
Normal
condition
Standard condition
Reference condition
2
CFM x 10-2, CFM x 10-1, ft3 x 10-1, gal(US)/min, gal(US)
Indicator LED
Switch operation (OUT1)
Measurement mode (Instantaneous flow)
: Start the setting here to supply power under the default settings.
Measurement mode (Accumulated flow)
Accumulation stop Accumulation starts
Press and
PF2A511 PF2A521 PF2A551
PF2A31 series
PF2W520 PF2W540PF2W504
P
F2W30 series
P
F2W33 series
PF2D30 series
2 sec.
4
Set valueor
3
4
Set value
or
3
4
4
4
Set value
Set value
Set value
or
3
4
Set value
or
3
4
Set valueor
3
4
Set value
or
3
4
Set value
or
3
4
Set value
or
3
U
nlock Lock
Unlock Lock
K
ey-lock function
Initialize mode
Key-lock function
1: Operate only the product with unit selction function (Model indication: without M).
2: Operate only the PF2A3 series.
3: Depend on the setting of switch operation in initialize mode.
4: Displayed in turn.
Input of the Set point 4
(OUT2)
: Accumulation starts and “-” flashes.
List of outputs
Find the diagram of the output required in the table below. Perform settings f
ollowing the Set value column on the right. Characters in ( ) are for OUT2.
Setting flow chart
Flow has exceeded the upper limit of the display flow range.
Reduce the flow.
Error type Troubleshooting method
Error indication
The switch output load current is more than 80 mA (OUT1).
Turn the power off and remove the cause of the over current. Then turn the power on again.
The switch output load current is more than 80 mA (OUT2).
The display flow range of accumulated flow has been exceeded.
To reset, press and buttons simultaneously for 2 seconds or longer. Then set all data again.
The set data has been changed unexpectedly.
To reset the accumulated flow value, press and buttons simultaneously for 2 seconds or longer.
Key-lock function
This function is used to prevent errors occurring due to unintentional changes of the set values.
Excessive instantaneous flow
Error name
OUT1 over current error
OUT2 over current error
Excessive accumulated flow
System error
Initialize mode
Default settings
The default settings are as follows. If this condition is acceptable, then keep these settings.
[F_1] Input the Set value of
instantaneous output
[n_1] Input of the Set point 1 (OUT1)
Function selection mode
Item
Default settings
The default settings are as follows. If this condition is acceptable, then keep these settings.
[n_2] Input of the Set point 2 (OUT1)
[n_3] Input of the Set point 3 (OUT2)
[n_4] Input of the Set point 4 (OUT2)
[F_2] Input the Set value of
i
nstantaneous output (Auto-preset)
-
[F_3] Input the Set value of
accumulated output
[1nL] Input of the Set value for the lower 3 digits (OUT1)
[
1nH
] Input of the Set value for the upper 3 digits (OUT1)
: When Non-Reverse output is selected as the switching operation, n becomes P.
In measurement mode, press the button, to display [F_ ]. This [F_ ] indicates the mode for changing each functional setting.
: When OUT1 or OUT2 is assigned to be instantaneous output mode during initialize mode, [F_1] and [F_2] are
displayed. When OUT1 or OUT2 is assigned to be accumulated output mode, [F_3] is displayed.
50% of max. rated flow
Default setting
50% of max. rated flow
50% of max. rated flow
50% of max. rated flow
-
[ 0]
[ 0]
[
2nL] Input of the Set value for the lower 3 digits (OUT2)
[
2nH
] Input of the Set value for the upper 3 digits (OUT2)
[ 0]
[ 0]
Items below can be set.
•Connected sensor •Display mode •Unit selection function
•Output mode (OUT1) •Output mode (OUT2) •Switch operation (OUT1)
•Switch operation (OUT2) •Reference condition
Troubleshooting
Mounting with the panel mount adapter
•Install the product as shown below.
•Insert panel mount adapter B into section A of panel mount adapter A. Push panel mount adapter B from behind until the display is fixed onto the panel. The pin of panel mount adapter B engages the notched part of panel adapter section A to fix the display.
Panel mount adapter A
A
Panel
Panel mount adapter B
Press
Insert
Mounting bracket
Wiring
•Connections should only be made with the power supply turned off.
•Use separate routes for the product wiring and any power or high voltage wiring. Otherwise, malfunction may result due to noise.
•Ensure that the FG terminal is connected to ground when using a commercially available switch-mode power supply. When a switch-mode power supply is connected to the product, switching noise will be superimposed and the product specification can no longer be met. This can be prevented by inserting a noise filter, such as a line noise filter and ferrite core, between the switch­mode power supply and the product, or by using a series power supply instead of a switch-mode power supply.
Connecting the wiring
•Use suitable crimp terminals for connection to the terminal block.
•Attention should be paid to the terminals to avoid short circuits.
1234
5678
Terminal block number
3
5
2
1
4
DC(-) (for sensor)
Sensor input
N
.C.
DC(-) (supply voltage)
D
C(+) (for sensor)
6
8
7
DC(+) (supply voltage)
OUT1
OUT2
Power is supplied
Outline of setting
The output will not operate for 3 seconds after supplying power.
The identification code of the product is displayed.
Measurement mode
The mode in which the flow is detected and displayed,
and the switch function is operating.
This is the basic operating mode;
and other modes should be selected for setting
changes and other function settings.
Initialize mode
Function
selection mode
Key-lock function
button press for 2 sec.
button
press.
button press for 3 sec.
Instantaneous flow
Switch output diagram Output mode Switch operation Set value
Instantaneous output mode
()
Non-Reverse
o
utput
()
Set point 2 Set point 1
()
H
ysteresis mode 2
Set point 1 Set point 2
()
Window comparator mode
S
et point 1 Set point 2
()
W
indow comparator mode
Reverse output
()
O
FF
ON
H
ysteresis
P_2
(
P_4)
P_1
(
P_3)
Instantaneous f
low
OFF
ON
Hysteresis 1Hysteresis 1
P_1 (P_3)
P_2
(P_4)
Instantaneous flow
OFF
ON
Hysteresis
n
_2
(n_4)
n
_1
(n_3)
I
nstantaneous flow
OFF
ON
Hysteresis 1Hysteresis 1
n_1
(n_3)
n_2
(n_4)
Instantaneous flow
Set point 2 Set point 1
()
Hysteresis mode 2
Accumulated flow
Accumulated output mode
()
Non-Reverse
output
()
U
pper 3 digits Lower 3 digits
+
(+)
Upper 3 digits Lower 3 digits
+
(+)
Reverse output
()
OFF
ON
T
ime
Time
Accumlated flow
1PH+1PL (2PH+2PL)
OFF
O
N
Time
Time
Accumlated flow
1nH+1nL
(2nH+2nL)
Accumulated pulse
Accumulated
pulse output
mode
()
N
o Set value input
No Set value input
Reverse output
()
OFF
O
N
Time
50 ms
OFF
O
N
Time
5
0 ms
Error display
Accumulated flow displayed
(flashing)
: If the error cannot be reset after the above measures are taken, then please contact SMC.
Specification / Outline with Dimensions
Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about product specifications and outline dimensions in detail.
Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. © 2011 SMC Corporation All Rights Reserved
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362
URL http://www.smcworld.com
Non-Reverse
o
utput
()
Refer to the SMC website (URL http://www.smcworld.com) for more information about troubleshooting.
1: In window comparator mode, the hysteresis is fixed at 3 digits. When setting, allow 7 digits or more between
Set point 1 and Set point 2 (Set point 3 and Set point 4).
2: When Set point 1 = Set point 2 (Set point 3 = Set point 4), chattering may occur.
Selection of display mode [
d_1
] Display instantaneous flow
I
tem
D
efault settings
Unit selection function
[
U_1
] L/min
S
election of output mode (OUT1)
[
o10]
Instantaneous output mode
Selection of output mode (OUT2) [
o20
] Instantaneous output mode
Selection of switch operation (OUT1) [
1_n
] Reverse output
Selection of switch operation (OUT2) [
2_n
] Reverse output
Selection of reference condition [Anr] Standard condition
S
election of the connected sensor
[
10L
] 1 to 10 L/min type (PF2A510)
[
04L
] 0.5 to 4 L/min type (PF2W504)
[
04d
] 0.4 to 4 L/min type (PF2D504)
Common
M
odel
Common
C
ommon
Common
Common
Common
P
F2A3 series only
PF2A30 series
PF2W30 series
[
11L
] 10 to 100 L/min type (PF2A511)
[
11L
] 10 to 100 L/min type (PF2W511)
PF2A31 series
PF2W33 series
PF2D3 series
Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more detailed information about panel cut-out dimensions.
: Operateonly the product with unit selection function.