SMC Networks IDFA22E-23-K, IDFA22E-23-L, IDFA22E-23-T, IDFA37E-23-L, IDFA37E-23-A Operation Manuals

...
IDFA22E-TFK18GB-A
IDX-OM-I076
Initial issue Dec. 2004
Rev.N:Apr, 2018
Refrigerated Air Dryer
MODEL / Series
IDFA22E-23-A,C,K,L,R,T,V IDFA37E-23- A,C,K,L,R,T,V IDFA55E-23- A,C,L,R,T,V IDFA75E-23- A,C,L,R,T,V
Please read this manual prior of using the air dryer.
Kee
p
the manual readily available for reference.
© 2018 SMC CORPORATION All Rights Reserved.
To Customers
Thank you for selecting SMC Refrigerated Air Dryer.
This operation manual must be read and understood thoroughly before using the product. It provides all essential information pertaining to safety, as well as, maximizing product efficiency in order to extend the life of the product.
In addition, it is strongly recommended that you follow all the safety guidelines and regulations set forth by the local government agency for proper installation and usage.
This manual explains about installation and trial operation of the product. These tasks should be performed only by individuals with the proper training and have a good understanding of the air dryer.
There is no production amends or financial compensation due to dryers trouble.
This manual contains confidential information proprietary to SMC. It must not be reproduced or disclosed to others, or used in any other way, in part or in whole, except as authorized in writing by SMC.
Note: The contents of this operation manual are subjected to change without prior notice.
Table of Contents
Table of Contents - 1
Chapter i Safety Instructions
i - 1 Warning: Before Using Air Dryer ......................................................... i - 1
i - 1 - 1 Hazard, Warning, and Caution Used in This Manual .................................... i - 1
i - 2 Danger Classifications/Position of Hazard warning Label........ i - 2
i - 2 - 1 Danger Classifications .................................................................................. i - 2
i - 2 - 2 Hazard of Electricity ..................................................................................... i - 3
i - 2 - 3 Hazard of Hot Surface .................................................................................. i - 3
i - 2 - 4 Hazard of Rotating Fan Motor ...................................................................... i - 3
i - 2 - 5 Danger of Compressed Air Circuit ................................................................ i - 3
i - 2 - 6 Positions of Hazard Warning Label............................................................... i - 4
i - 2 - 7 Hazard of Refrigerant ................................................................................... i - 5
i - 2 - 8 Cautions about Usage .................................................................................. i - 6
i - 2 - 9 Other Label .................................................................................................. i - 6
i - 3 Disposal ........................................................................................................ i - 7
i - 4 Limited warranty and Disclaimer / Compliance Requirements ......... i - 8
Chapter 1 Parts Name and Functions
1 - 1 Parts Names and Functions ................................................................ 1 - 1
Chapter 2 Transportation / Installation
2 - 1 Transportation .......................................................................................... 2 - 1
2 - 2 Installation.................................................................................................. 2 - 2
2 - 2 - 1 Location ..................................................................................................... 2 - 2
2 - 2 - 2 Anchorage .................................................................................................. 2 - 3
2 - 2 - 3 Air piping .................................................................................................... 2 - 3
2 - 2 - 4 Drain Tube .................................................................................................. 2 - 3
2 - 2 - 5 Electric Wiring ............................................................................................ 2 - 4
2 - 3 Cautions for Reinstallation .................................................................. 2 - 5
Chapter 3 Operation / Shutdown
3 - 1 Check points before operation .......................................................... 3 - 1
3 - 2 Operation .................................................................................................... 3 - 1
3 - 3 Shutdown ................................................................................................... 3 - 2
3 - 4 Cautions about restart........................................................................... 3 - 2
3 - 5 Check points before restart................................................................. 3 - 2
3 - 6 Precautions for long-term non-operation ...................................... 3 - 2
Chapter 4 Maintenance
4 - 1 Daily inspection ....................................................................................... 4 - 1
4 - 2 Periodical maintenance ........................................................................ 4 - 1
4 - 2 - 1 Cleaning of ventilation grille (suction grille) ................................................. 4 - 1
4 - 2 - 2 Service parts .............................................................................................. 4 - 1
4 - 2 - 3 Cleaning of the case assembly ................................................................... 4 - 1
Chapter 5 Troubleshooting
5 - 1 Cause and countermeasure of errors ............................................. 5 - 1
5 - 2 How to reset the thermal relay and high pressure switch ...... 5 - 3
Table of Contents
Table of Contents
Table of Contents - 2
Chapter 6 References
6 - 1 Specifications ........................................................................................... 6 - 1
6 - 2 Refrigerant with GWP reference ....................................................... 6 - 1
6 - 3 Dimensions ................................................................................................ 6 - 2
6 - 4 Electrical Circuit ...................................................................................... 6 - 3
6 - 5 Compressed Air and Refrigerant Circuit / Operation Principles ..... 6 - 4
Chapter 7 Option Specification A
7 - 1 Safety instructions .................................................................................. 7 - 1
7 - 2 Specifications ........................................................................................... 7 - 1
7 - 3 Air piping .................................................................................................... 7 - 1
7 - 4 Air flow capacity ...................................................................................... 7 - 1
7 - 5 Compressed Air and Refrigerant Circuit / Operation Principles ... 7 - 2
Chapter 8 Option Specification C
8 - 1 Safety instructions .................................................................................. 8 - 1
8 - 2 Precautions for the installation and handling of the product ...... 8 - 1
8 - 3 Specifications ........................................................................................... 8 - 1
Chapter 9 Option Specification K
9 - 1 Safety instructions .................................................................................. 9 - 1
9 - 2 Specifications ........................................................................................... 9 - 2
Chapter 10 Option Specification L
10 - 1 Safety instructions ................................................................................ 10 - 1
10 - 2 Specifications ......................................................................................... 10 - 1
10 - 3 Maintenance ............................................................................................ 10 - 2
Chapter 11 Option Specification R
11 - 1 Safety instructions ................................................................................. 11 - 1
11 - 2 Specifications of GFCI ......................................................................... 11 - 1
11 - 3 How to connect the power supply ................................................... 11 - 2
11 - 4 Cautions for handling the GFCI ........................................................ 11 - 2
11 - 5 Electrical Circuit ..................................................................................... 11 - 2
Chapter 12 Specification for Option T
12 - 1 Safety instructions ................................................................................ 12 - 1
12 - 2 Specifications ......................................................................................... 12 - 1
12 - 3 Remote operation ................................................................................. 12 - 1
12 - 4 How to connect the power supply and signal cable................ 12 - 2
12 - 5 How to re-start the operation ............................................................ 12 - 2
12 - 6 Electric circuit ......................................................................................... 12 - 3
Chapter 13 Specification for Option V
13 - 1 Safety instructions ................................................................................ 13 - 1
13 - 2 Specifications ......................................................................................... 13 - 2
13 - 3 How to perform maintenance ........................................................... 13 - 3
13 - 4 Electric circuit .......................................................................................... 13 - 3
Chapter 14 Service Record
14 - 1 Service Record ....................................................................................... 14 - 1
Air Dryer i Safety Instructions
i Safety Instructions
i - 1
IDX-OM-I076
IDFA Series
i Safety Instructions
Be sure to read and comprehend important cautionary notifications in this operation manual before use
i-1 Warning: Before Using Air Dryer
In this chapter, the stated contents are especially about safety. This Air Dryer is installed downstream of the air compressor to remove moisture. The manufacturer is not responsible for any misuses or misapplications.
This air dryer operates with high voltage and hot surfaces during operation. In addition, this air dryer has high speed rotating fan and motor, which can cause serious injury upon accidental contact. It is advised that you contact the factory or SMC authorized dealer for spare parts or other servicing needs .
We strongly recommend that any one who is working with this air dryer need to read and understand the instructions in this manual beforehand. Often, it’s necessary for the people invo lved, to r eceive training in order to address the issues of safety and proper application.
When short period power shortage (including instantly recovered shortage) is recovered, it may take a longer starting period than usual starting or may not start due to the protective devices. In this case, turn off the Switch with lamp on dryer panel and wait 3 minutes. After this step, turn on the switch to restart. When the cover panel of this unit is open, the Switch with lamp must be in the off position, because dryer may start itself when the power supply is recovered.
Connections to a power source where the product is exposed to transient stresses exceeding overvoltage category II (as defined in IEC60664-1). Only connect to TN-S power distribution systems with N conductively connected to PE.
i-1-1 Hazard, Warning, and Caution Used in This Manual
This product is designed with the first priority on safety. However, there are some inherent risks that cannot be eliminated. This manual classifies these risks into the following three categories according to the severity: DANGER, WARNING and CAUTION. Read these statements carefully and thoroughly understand them before operating or performing maintenance on the unit.
DANGER
DANGER indicates that there is an imminent hazard that will cause serious injury or death if not avoided.
Do not operate the product without the cover panel.
WARNING
WARNING indicates that there is a hazard that may cause serious injury or death if not avoided.
CAUTION
CAUTION indicates that there is a hazard that may cause minor injury.
Air Dryer i Safety Instructions
i-2 Danger Classifications & Position of Hazard warning Labels
i - 2
IDFA Series
IDX-OM-I076
i-2 Danger Classifications & Position of Hazard warning Labels
To help you recognize the hazards, the unit utilizes special graphics to indicate different hazards. Confirm the contents of the hazards and the location of the labels before operation.
Warning
- Only properly trained, qualified personnel are allowed to perform tasks such as: Operation, installation, relocation of product and maintenance works.
- Should any problem occurs, address it according to instruction in this manual.
- Identify problems following the guidelines in Chapter 5 for Troubleshooting before proceed with maintenance works.
- In the event of any problems the product should not be turned on. When the product fails or a fault occurs, shutdown immediately, and contact for service.
i-2-1 Danger Classifications
Specific danger classifications of this product are as follows.
Hazard of Electricity
Since this product operates with high voltage, there is the danger of electric shock. This special symbol is used, along with key words: “CAUTION”, “WARNING” or “DANGER”, on the product and in this manual.
Hazard of Hot Surface
Since this product becomes hot while running, there is the danger of burn injury. This special symbol is used, along with key words: “CAUTION”, “WARNING” or
DANGER”, on the product and in this manual.
Hazard of Rotating Object
Since this product has parts that rotate at high speed while running, there is the danger of bodily injury. This special symbol is used, along with key words: “CAUTION”, “WARNING” or DANGER”, on the product and in this manual.
Air Dryer i Safety Instructions
i-2 Danger Classifications & Position of Hazard warning Labels
i - 3
IDFA Series
IDX-OM-I076
i-2-2 Hazard of Electricity
Warning
Inside of this product, there is a power-supplying section with high voltage separated by the cover panel. Do not operate the product with the cover panel off.
i-2-3 Hazard of Hot Surface
Warning
Since this product has parts that become hot during operation, there is the danger of burn-associated injuries. These parts remain hot even after power is off. Wait until the unit has cooled down before touching.
i-2-4 Hazard of Rotating Fan Motor
Warning
Since this product has parts that rotate during operation, there is the danger of injury resulting from direct contact. The fan and rotor will start/stop automatically. Thus, do not work on them when power is on.
i-2-5 Danger of Compressed Air Circuit
Warning
Before replacing or cleaning parts, be sure to relief the pressure remained inside of the product until the gauge indicates 0”. High pressure can propel object at high velocity and cause injury.
Air Dryer i Safety Instructions
i-2 Danger Classifications & Position of Hazard warning Labels
i - 4
IDFA Series
IDX-OM-I076
i-2-6 Positions of Danger Warning Label
Warning
- Read with caution and pay attention to the notations of danger warning labels.
- Do not remove or modify danger warning labels.
- Confirm the positions of danger warning labels.
Front
WARNING 警告
!
1 Remove panels fo r maintenance only. 2 Never insert an ything into product to en sure safety. 3 Cut power p rior to maintenance to prevent electric sho ck. 4 Settle product to room temp.before main­ tenance topr event burn or frostbite. 5 Ensure zero air pressure before replacing parts.
1 点検以 外はパ ネルを取り 外さない こと。 2 回転物 があるの で指、棒 状の物を 差し 込 まないこ と。 3 感電の 恐れがあるので、 点検の 前には電源 を   切るこ と。 4 火傷の 恐れがあるので、 点検の 前には装置 を   常温 にすること 。 5 部品交 換の前 には必ず、 空気圧力 を"0" に   するこ と。
!
Air Dryer i Safety Instructions
i-2 Danger Classifications & Position of Hazard warning Labels
i - 5
IDFA Series
IDX-OM-I076
Front
i-2-7 Hazard of Refrigerant
Caution
- This product uses Fluorocarbon (HFC) as a refrigerant.
- It is strictly forbidden to emit Fluorocarbon into the atmosphere. Before you repair the refrigerant circuit, you should collect the refrigerant with proper evacuation system. The collected refrigerant should be properly recycled by qualified agency. Only personnel with proper credentials are allowed to handle refrigerant.
- Only properly trained qualified personnel are allowed to remove the cover panel of the product.
- The quantity and the type of Fluorocarbon are mentioned on the specification label. See Page i - 6.
Air Dryer i Safety Instructions
i-2 Danger Classifications & Position of Hazard warning Labels
i - 6
IDFA Series
IDX-OM-I076
i-2-8 Cautions about Usage
Warning
Please follow the instructions on the warning labels. Do not remove or deface warning labels, and confirm the location of all warning labels.
i-2-9 Other Label
Front
Front
CAUTION 注意
!
1 Read manual before operation. 2 Ensure vantilation and maintenance space. 3 Keep water away from the product. 4 Secure In / Out connector with spanner during piping. 5 Wait 3 minutes before restart. 6 Ensure Running Condition / Evaporating Temp. in green zone.
1 ご使用 前に必ず 取扱説明 書を読ん でください。 2 通風、 メンテ ナンススペ ースを確 保して ください。 3 雨や水滴がかか らないよ うにして ください。 4 IN/ OUT ポートを スパナで固 定して 配管してく ださい。 5 再起動 は運転停 止3分後 に行って ください。 6 RU NNIN G CO NDI TION ・蒸発温 度計は   グリーン帯で使 用してくだ さい。
Specification Label
Air Dryer i Safety Instructions
i-3 Disposal
i - 7
IDX-OM-I076
IDFA Series
i-3 Disposal
When you dispose of the product, you should collect the refrigerant and the compressor oil inside the refrigerant circuit.
Caution
This product contains Fluorocarbon HFC. It is strictly forbidden to emit Fluorocarbon into the atmosphere. Before you repair the
refrigerant circuit, you should collect the refrigerant with proper evacuation system. The collected refrigerant should be properly recycled by qualified agency. Only personnel with proper credentials are allowed to handle refrigerant.
Only properly trained and qualified personnel are allowed to remove the cover panel of the product.
The quantity and the type of Fluorocarbon are mentioned on the specification label. See Page i - 6.
Caution
Dispose of the refrigerant and compressor oil according to the regulation of local government.
Only personnel with proper credentials are allowed to collect refrigerant and compressor oil.
Only properly trained and qualified personnel are allowed to remove the cover panel of the product.
For any questions, please contact an SMC authorized dealers.
Air Dryer i Safety Instructions
i-4 Limited warranty and Disclaimer / Compliance Requirements
i - 8
IDFA Series
IDX-OM-I076
i-4 Limited warranty and Disclaimer / Compliance Requirements
The product used subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product.
Limited warranty and Disclaimer
1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.
Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility, a
replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in
the specified catalog for the particular products.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of weapons of mass
destruction (WMD) or other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are govemed by the relevant
security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC product of a SMC product to another country, assure that all local rules goveming that export are known and followed.
Caution
The Product is provided use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contact if necessary. If anything is unclear, contact your nearest sales branch.
Air Dryer 1 Name and Functions Parts
1-1 Parts Name and Functions
1 - 1
IDX-OM-I076
IDFA Series
1 Parts Name and Functions
1-1 Parts Name and Functions
IDFA22E,37E,55E,75E
Front
Switch with Lamp (ON /OFF Switch)
The lamp is continuously ON during normal operation.
Evaporation Thermometer
Indicates the evaporating temperature of refrigerant on low-pressure side. During normal operation, the indicator remains in the green zone.
Ventilation Grille (Exhaust)
Hot air will be exhausted by condenser fan. Do not
Panel Lock (x 2)
Another one is on opposite side.
Drain Tube
Discharges drain.
Auto Drain
Check if drained correctly once a day.
Compressed Air (IN)
Compressed Air (OUT)
Ball Valve
Front Panel
You can see the terminal block when you remove this cover. Connect the power cable through the rubber grommet.
L N PE
Customer Connection Side
Terminal Connecting Screw: M3
Applicable electrical wire:
1.25mm2 or more
(Width 6.5mm and below)
Thermal Relay (Only for IDFA55E and IDFA75E)
(The thermal relay is placed at the inside of a front panel.) Refer to page 5-3 to reset the thermal relay.
High Pressure Switch (Only for IDFA55E and IDFA75E)
(The high pressure switch is placed at the inside of a front panel.) Refer to page 5-3 to reset the high pressure switch.
Air Dryer 1 Name and Functions Parts
1-1 Parts Name and Functions
1 - 2
IDX-OM-I076
IDFA Series
Front
Rubber Grommet
Power cord outlet
Panel Lock (x 2)
Another one is on opposite side.
Ventilation Grille (Suction)
Ambient air will be sucked by condenser fan. Do not block these vents.
Panel Lock (x 2) (Only for IDFA75E)
Another one is on opposite side.
Air Dryer
2 Transportation / Installation
2-1 Transportation
2 - 1
IDX-OM-I076
IDFA Series
2 Transportation/Installation
Warning
Use the product in the right way. During Installation, operation, maintenance, and check, you should be careful in keeping the safety of human body.
Caution
Transportation, installation, and maintenance including dangerous work must be done by
a personnel who has enough knowledge and experience about the product and the sysytem.
2-1 Transportation
When you transport the product, you should follow the instructions below:
You should lift the product from the base surface with careful attention to prevent tipping over. Do not lay the product sideways, or you will damage the product. Do not suspend the product from the ceiling or hang from the wall. Do not transport the product with any part such as an air filter mounted on the fittings at the air inlet or
outlet port of the product. If it is unavoidable to transport the product with such a part mounted, support the mounted part with a bracket to prevent the product from being affected by vibration during transportation.
Warning
This product is heavy. Each model weights about 50kg or more. More than one person is required to move it, a forklift is necessary.
Loading...