SMC Networks EX600 Series, EX600-SEN Operation Manuals

Fieldbus system
Operation Manual
EX600-SEN
TX+
Signal name
RX+
TX
RX
1
Pin
number
2
3
4
BUS IN
Configuration
ON
12345678
Setting3
Settin
g
1
ON
12345678
Setting2
ON
12345678
•IP address setting switch
192.168.0.254
:
192.168.0.1
1
192.168.1.254
2
OFF
:
ON
OFF
ON
:
OFF
ON
The power supply for control and input is Off.
MS LED is off
Either of the following conditions:
•The unit has not been configured correctly.
•Fieldbus is idling.
Green MS LED is flashing
The unit is in normal operation.
Green MS LED is On
Recoverable error.
Red MS LED is flashing
OFF
:
OFF
ON
3
ON
:
OFF
ON
Settings2
:
192.168.1.1
DHCP mode
*
1
Remote Control mode
*
2
:
ON
ON
OFF
:
OFF
ON
OFF
:
ON
ON/OFF
ON/OFF
:
OFF
ON
OFF
Settings1
IP address
8
4 5
ON
:
OFF
ON
ON
:
OFF
ON
6
ON
:
OFF
ON
:
OFF
ON
OFF
:
OFF
ON
OFF
:
OFF
ON
OFF
7 8
ON
:
OFF
ON
ON
:
OFF
ON
:
OFF
ON
OFF
:
OFF
ON
OFF
•V_SEL switch: The number of outputs (size) occupied by the SI unit is selected.
Content
Number of occupied valve 32 outputs
Number of occupied valve 24 outputs
Number of occupied valve 16 outputs
Settings3
1
Number of occupied valve 8 outputs
SI unit output data size
4 byte (Default setting)
3 byte
2 byte
1 byte
2
OFF
OFF
ON
ON
OFF
ON
OFF
ON
•Switch for diagnosis: Allocates the diagnostic data to the input data.
Content
Input data only (Default setting)
Input data + System diagnosis
Input data + System diagnosis + Unit diagnosis (up to 10 units)
Settings3
3
Diagnostic size set for
the input
0 byte
4 byte
6 byte
4
OFF
OFF
ON
OFF
ON
OFF
Mode
0
1
2
•EtherNet/IPTMcommunication setting switch.
Automatic
10 Mbps, half duplex
10 Mbps, full duplex
100 Mbps, half duplex
Settings3
100 Mbps, full duplex
Communication speed full duplex/half duplex setting
6
OFF
ON
ON
ON
ON
7 8
ON/OFF
OFF
OFF
ON
ON/OFF
OFF
ON
OFF
ON ON
*1: The mode to obtain IP address from DHCP server. Obtained IP address is lost when the power supply is cut. *2: The mode to respond to the commands below of BOOTP/DHCP Server provided by Rockwell Automation.
Enable DHCP: IP address etc. can be obtained from BOOTP/DHCP Server.
If the power is supplied again in this state, information including IP address is obtained again.
Disable DHCP: IP address etc. cannot be obtained from BOOTP/DHCP Server.
If the power is supplied again with this condition, previous setting can be held.
•HOLD/CLEAR switch: Sets the output status when the fieldbus has a communication error or is in idling.
Content
Output is off. (Default setting)
Holds the output.
Settings3
5
OFF
ON
The element in SI unit is broken.
Red MS LED is On
The power supply for control and input is Off, or IP address is not set.
NS LED is Off
The unit received an IP address, but connection is not established.
Green NS LED is flashing
Connection is established.
Green NS LED is On
Connection timeout.
Red NS LED is flashing
IP address is duplicated.
Red NS LED is On
12
34
NOTE
The direct current power supply to combine should be UL1310 Class2 power supply when conformity to UL is necessary.
Safety Instructions
Do not operate the product outside of the specifications.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not disassemble, modify (including changing the printed circuit board) or repair.
An injury or failure can result.
Do not operate in an atmosphere containing flammable or explosive gases.
Fire or an explosion can result. This product is not designed to be explosion proof.
If using the product in an interlocking circuit:
•Provide a double interlocking system, for example a mechanical system.
•Check the product regularly for proper operation. Otherwise malfunction can result, causing an accident.
The following instructions must be followed during maintenance:
•Turn off the power supply.
•Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance.
Otherwise an injury can result.
Provide grounding to assure the safety and noise resistance of the Fieldbus system.
Individual grounding should be provided close to the product with a short cable.
Thank you for purchasing an SMC EX600 Series Fieldbus system. Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations. Please keep this manual handy for future reference.
To obtain more detailed information about operating this product, please refer to the SMC website (URL http://www.smcworld.com
) or
contact SMC directly.
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC), Japan Industrial Standards (JIS) and other safety regulations.
Warning
Caution
After maintenance is complete, perform appropriate functional inspections.
Stop operation if the equipment does not function properly. Safety cannot be assured in the case of unexpected malfunction.
CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
Caution:
Warning:
Danger:
WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury.
DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Operator
This operation manual is intended for those who have knowledge of machinery
using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenace of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product.
Maintenance
•Maintenance should be performed according to the Safety Instructions.
•Perform regular maintenance and inspections.
There is a risk of unexpected malfunction.
•Do not use solvents such as benzene, thinner etc. to clean each unit.
They could damage the surface of the body and erase the markings on the body. Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the stains again with a dry cloth.
When handling the unit or assembling/replacing units:
•Do not touch the sharp metal parts of the connector or plug for connecting units.
•Take care not to hit your hand when disassembling the unit. The connecting portions of the unit are firmly joined with seals.
•When joining units, take care not to get fingers caught between units.
An injury can result.
Refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about maintenance.
8
7
6
9
10
2
4
3
5
11
1
12
Status display LED
Description Function
Displays the status of the unit.
Display cover Open for the setting of switch.
Display cover tightening screw Loosen to open the display cover.
Marker groove Groove to mount a marker.
1
No.
2
3
4
5 Connector (PCI) Connects the cable of the handheld terminal.
Valve plate mounting screw hole Fixes the valve plate.
Valve plate mounting groove Groove to insert the valve plate into.
6
7
8 Joint bracket Bracket for joining to adjacent units.
Unit connector (plug) Transmits signals and power supplies to adjacent units.
Connector (BUS IN) Connects the cable for fieldbus inputs.
9
10
11
Seal cap (1 pcs.) Mounted on to unused connectors. (PCI)12
Names and Functions of Product
Names of individual parts
MAC address label Displays the 12 digit MAC address which is different for each SI unit.
Assembly
Composing the unit as a manifold
(1)Connect the unit to the end plate.
The Digital unit, Analog unit can be connected in any order. Tighten the bracket of the joint using tightening torque
1.5 to 1.6 Nm.
(2)Add more units.
Up to 10 units (including the SI unit) can be connected to one manifold.
(3)Connecting the SI unit.
After connecting the necessary units, connect the SI unit. Connecting method is the same as above (1), (2).
(4)Mounting the valve plate.
Mount the valve plate (EX600-ZMV ) to the valve manifold using the valve set screws. (M3x8) Apply 0.6 to 0.7 Nm tightening torque to the screws.
1
2
(5)Connect the SI unit and the valve manifold.
Insert the valve plate to the valve plate set groove on the side of SI unit. Then, tighten it with the valve plate set screws (M4x6) to fix the plate. Tightening torque for set screws 0.7 to 0.8 Nm.
5
Installation
•Direct mounting (1)When joining six or more units, fix the middle
part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB1) before mounting using 2-M4x5 screws. Tightening torque: 0.7 to 0.8 Nm.
(2)Fix and tighten the end plates at one end of the
unit. (M4) Tightening torque: 0.7 to 0.8 Nm. Fix the end plate at the valve side while referring to the operation manual of the corresponding valve manifold.
Mounting and Installation
Intermediate reinforcing brace (EX600-ZMB1)
•DIN rail mounting (Available for series other than SY series. Refer to the catalog for SY series.) (1)When joining six or more units, fix the middle
part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB2) before mounting, using 2-M4x6 screws. Tightening torque: 0.7 to 0.8 Nm.
(2)Mount the end plate bracket (EX600-ZMA2) to the end
plate at the opposite end to the valves, using 2-M4x14 screws. Tightening torque: 0.7 to 0.8 Nm.
(3)Hook the DIN rail mounting groove to the DIN rail.
(4)Press the manifold using its side hooked to the
DIN rail as a fulcrum until the manifold is locked.
Intermediate reinforcing brace (EX600-ZMB2)
1
End plate bracket (EX600-ZMA2)
2
3
4
DIN rail
DIN rail mounting groove
4
Valve plate (EX600-ZMV )
(1)
Mark A at cable end
Mark B at cable end
Mark C on the unit
(2)
(3)
End plate bracket
(EX600-ZMA2)
5
•Connector pin assignment
(5)Fix the manifold by tightening the DIN rail fixing
screws of the EX600-ZMA2. (M4x20) Tightening torque: 0.7 to 0.8 Nm. The tightening torque at the valve side depends on the valve type. Refer to the operation manual of the corresponding valve manifold.
Wiring
•Connect the M12 connector cable. M12 connector is applicable for SPEEDCON connector. SPEEDCON connector wiring method is explained below. (1)Align the mark B on the metal bracket of the cable side connector (plug/socket) with
the mark A.
(2)Align the mark C on the unit and insert the connector into the unit vertically.
If they are not aligned, the connector cannot be joined properly.
(3)When the mark B of the connector has been turned 180 degrees (1/2 turn), wiring is
completed. Confirm that the connection is not loose. If turned too far, it will become hard to remove the connector.
Setting and Adjustment
Refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about setting and adjustment.
-10 to 50 oC (Max. surrounding air temperature rating: 50 oC)
Operating temperature range
-20 to 60 oCStorage temperature range
For use in Pollution Degree 2 Environment (UL508)Pollution degree
Solenoid valve with lamp and circuit of protection of surge voltage of 24 VDC 1.5 W (SMC)
Connected load
Commissioning
•Parameter Setting •Hardware Configuration (EDS file) •I/O Map
•Diagnostic
10 to 57 Hz: constant amplitude 0.75 mm p-p
57 to 150 Hz: constant acceleration 49 m/s
2
for 2 hours each in direction X, Y and Z respectively (De-energized)
Vibration resistance
147 m/s23 times each in directions of X, Y and Z respectively (De-energized)Impact resistance
Troubleshooting
Refer to the LED Display. Refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about troubleshooting.
Specification
Refer to the product catalog or SMC website (URL http://www.smcworld.com) to obtain more detailed information about product specifications.
Outline with Dimensions
Refer to the product catalog or SMC website (URL http://www.smcworld.com) to obtain more detailed information about outline dimensions.
Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. © 2010 SMC Corporation All Rights Reserved
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362
URL http://www.smcworld.com
Refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about these setting above.
24 VDC Class2, 2 A
Power supply
24 VDC Class2, 2 AOutput
Control and input
Refer to the SMC website (URL http://www.smcworld.com
) to obtain more detailed
information about LED display.
SI unit common status
Content
The power supply for control and input is Off.
LED display
Off
The unit is in normal operation.
Green LEDs are On
A component failure inside the SI unit.
Red ST(M) LED is On
The power supply voltage for control and input is abnormal.
Red PWR LED is On
The power supply voltage for output is abnormal.
Red PWR(V) LED is On
A unit other than the SI unit has been diagnosed and detected.
Green ST(M) LED is flashing
Either of the following conditions:
•The valve On/Off counter has exceeded the set value.
•The valve is short circuited or disconnected.
Red ST(M) LED is flashing
Either of the following conditions:
•Connection error between units has occurred.
•Cofiguration memory error has occurred.
Red/green ST(M) LED is flashing alternately
LED Display
The status display LED displays the power supply and communication status.
Display
ST(M)
PWR
PWR(V)
MS
Content
Displays the diagnosis status of the unit.
Displays the status of the power supply voltage for control and input.
Displays the status of the power supply voltage for outputs.
Displays the module status.
NS Displays the network status.
EtherNet/IP
TM
status
Loading...