SMC Networks EX121-SDN1, EX120-SDN1, EX124D-U-SDN1, EX122-SDN1 User Manual

OPERATION MANUAL
Doc.No. EX## -OME0015
SI unit
EX120-SDN1
EX121-SDN1
EX122-SDN1
EX124D/U-SDN1
SMC Corporation
SMC CORPORATION
Contents
Doc.No.EX
2.Specifications
2-1.General specifications ------------------------------------------------------ P4
2-2.Electrical and network specifications ------------------------------------------------------ P4
2-3.Applicable solenoid valve series ------------------------------------------------------ P5
3.Wiring and setting
3-1.Connection type ------------------------------------------------------ P5
3-2.Address setting ------------------------------------------------------ P8
4.LED indicator and Physical dimensions
##-OME0015
4-1.LED indication ------------------------------------------------------ P9
4-2.Physical dimensions ------------------------------------------------------ P9
5.EDS(Electronic Data Sheet) File ------------------------------------------------------ P12
6.Trouble Shooting ------------------------------------------------------ P13
- 2 -
SMC CORPORATION
1.Safety instructions
These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by label of "CAUTION" , "WARNING". To ensure safety, be sure to observe ISO, JIS and other safety practices.
Doc.No.EX
##-OME0015
CAUTION: Operator error could result in injury or equipment damage.
WARNING: Operator error could result in serious injury or loss of life.
CAUTION
Thoroughly read this manual and operate the product within the specified range. Follow the instructions. Do not drop or impart any impact to the product. Use within specified voltage range. Use outside of specified voltage will cause malfunction, damage of unit, electric shock, and fire. Do not touch the terminal or internal circuit board while they are energized. It may cause malfunction, damage to unit, and electric shock. Use within operating ambient temperature. Do not use where temperature can rapidly change even thought it is within the specifications. Foreign objects should be prevented from entering the product. Contamination by foreign objects, such as wire chips will cause fire, breakage, and malfunction. Use within the operating environment of the protection structure. In case of IP20, avoid use in the place where water and oil scatter. To realize IP65, install manifold properly and give some prevention against splash of liguid to electrical entry. Carry out periodical checks to confirm correct operation. Safety may not be maintained by unintentional malfunction or incorrect operation. Design must consider the space necessary for maintenance. As the contents of this manual is sometimes changed without the previous announcement, understand them beforehand, please. SI unit is not explosion proof. Operation in explosive enviromment may cause explosion accident.
WARNING
The product specified here is designed to be used in standard factory automation equipment. Do not use in machinery and/or equipment where operators may be injured, and malfunction or failure may cause loss of life. Do not disassemble to repair or modify the product.
Connection
CAUTION
Power of the product and all other equipments should be turned off while wiring. Tighten the wiring with connector and tarminal screw completely. Short circuit, fire, and malfunction will be caused if connector and tarminal screw are not tightened enough. Avoid incorrect wiring. It may damage the product and/or other equipments. Ensure that the FG terminal is correctly grounded. Power with correct capacity should be prepared by considering the in-rush current when starting. Influence of noise should be avoided for the wiring. Wiring should be separated from power cables and high voltage cables. Ensure that the power is within the specified voltage range. Ensure that the cable is capable of supporting the solenoid valve and SI unit in terms of rating.
Applicable solenoid valves
CAUTION
SMC offers no guarantee against malfunction and damage of unit when valves not described to “2-3.Applicable solenoid valve series” and loads which is not valve are connected.
- 3 -
2. Specifications
2-1. General specifications
Item Specifications Model EX120
-SDN1
Operating ambient temp. 0 to +55(with 8 points of valve ON)
0 to +50(with 16 points of valve ON)
Operating ambient humidity 35 to 85%RH(No dew condensation) Storage ambient temp.
-20 to +60
Vibration proof 50m/s2 (comply with JIS C 0911) Impact proof 100m/s2 (comply with JIS C 0912) Noise immunity
Normal mode ±1500 V Pulse 1µs Common mode ±1500 V Pulse 1µs Radiation 1000 V ±Pulse 1µs
Withstand voltage AC1000V for 1 min. between FG and external
terminal package.
Insulation resistance DC500V, 2M between FG and external terminal
package. Operating environment No corrosive gas and no dust Weight 110g
or less
Protection class IP20 IP65
EX121
-SDN1
140g
or less
EX122
-SDN1
130g or less
EX124D
-SDN1
EX124U
-SDN1
240g
or less
SMC CORPORATION
Doc.No.EX
##-OME0015
2-2. Electrical and network specifications
Item Specifications Applicable system DeviceNet Release 2.0 Power supply voltage for communication DC11V to DC25V
Power supply voltage for solenoid valve DC24V +10% -5%
Communication and
current
Internal power supply Power supply for
Solenoid valve Solenoid valve Connection
Output style NPN output (Open collector)
Connected load DC24V, Solenoid valve with lamp-surge voltage spec.
Insulation type Opt-coupler insulation type Residual voltage 0.4V DC or less
Applicable DeviceNet
MAC ID setting range 0 to 63 (Set by Dip switch) Baud Rate (Transmission speed) 500kbps, 250kbps, 125kbps (Set by Dip switch) Slave (branch station) type Group 2 only server Connection type T branch type, Multi drop type Device type 16 Product code 288 Revision Referred to EDS file. Vendor ID 7
Network connection spec.
Corresponding message Polled command (I/O message ), Explicit message
(supplied by communication connector)
90mA or less (DC24V)Consumption
1.5A or less (DC24V)
protection circuit of 2.1W or less. (made by SMC)
Volume- Release 1.2 Volume- Release 1.1