SMC Networks D-A72H, D-A73H, D-A76H, D-A80H, D-A73C User Manual

...
Page 1
Auto Switch Guide
Reed Switches/Solid State Switches
For Air Grippers (Rotary Actuators)

Applicable Auto Switch

Type
Reed switchSolid state switch
2-color
indication
2-color
indication
Auto
switch
Rail
Direct
Rail
Tie-rod
Rail
Direct
Rail
Direct
Tie-rod
Electrical
entry
Grommet
Connector
Grommet
Grommet
Connector
Grommet
Grommet
Grommet
Connector
Grommet
Grommet
Connector
Grommet
Grommet
Grommet
Grommet
Auto switch model
D-A72/A73/A80
D-A72H/A73H D-A76H/A80H
D-A73C/A80C
D-A53/A54/A56
D-A64/A67
D-A90/A93/A96
D-A90V/A93V/A96V
D-90A/93A
D-R731/R732
D-R801/R802
D-R731C/R732C
D-R801C/R802C
D-A79W
D-A59W
D-F79/F7P/J79
D-F7NV/F7PV/F7BV
D-F59/F5P/J51/J59
D-S991/S992/S99V1/S99V2
D-T991/T992/T99V1/T99V2
D-S9P1/S9P2/S9PV1/S9PV2
D-S791/S792
D-T791/T792
D-S7P1/S7P2
D-T791C/T792C
D-F8N/F8P/F8B
D-M9N/M9P/M9B
D-M9NV/M9PV/M9BV
D-Y59A/Y7P/Y59B
D-Y69A/Y7PV/Y69B
D-F79W/F7PW/J79W
D-Y7NW/Y7PW/Y7BW
D-Y7NWV/Y7PWV/Y7BWV
D-F9NW/F9PW/F9BW
D-F9NWV/F9PWV/F9BWV
D-F59W/F5PW/J59W
D-90/97
D-J79C
Applicable rotary actuators
Size
CDRA1 CDRB CDRQ2 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-2510-40 10-30 16-25 32-125 10-25 32-63 20-50
MRQ
MDSUB
MSQ
MHZ2 MHZJ2
Applicable air grippers
Size
MHL2 MDHR MHS
MHK MHS MHC2 MHT2 12-25
MHW2
MHY MRHQ 10-25
Page
12-13-7
12-13-8
12-13-9
12-13-10
12-13-11
12-13-12
12-13-13
12-13-14
12-13-15
12-13-16
12-13-17
12-13-18
12-13-19
12-13-20
1
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
Rail
2-color indication
With diagnosis output
Rail
Tie-rod
Direct
Water resistant
2-color indication
Rail
Tie-rod
With timer
Note) As for the applicable auto switches on Rotary Actuators, refer to pages in Best Pneumatics Vol. 11.
Grommet
Grommet
Grommet
D-F79F
D-F59F
D-F7BAL/F7BAVL
D-F5BAL
D-Y7BAL
D-F9BAL
D-F7NTL
D-F5NTL
12-13-21
12-13-22
12-13-24
12-13-23
12-13-1
Page 2
1. Check the specifications.
Read the specifications carefully and use this product appropriately. The product may be damaged or malfunction if it is used outside the range of specifications of current current, voltage, temperature or impact.
2. Use caution when multiple cylinders are used and close to each other.
When two or more auto switch cylinders are lined up in close proximity to each other, magnetic field interference may cause the switches to malfunction. Maintain a minimum cylinder separation of 40 mm. (When the allowable interval is specified for each cylinder series, use the indicated value.)
3. Use caution to the ON time of a switch at the intermediate position of stroke.
When an auto switch is placed at an intermediate position of the stroke and a load is driven at the time the piston passes, the auto switch will operate, but if the speed is too great, the operating time will be shortened and the load may not operate properly. The maximum detectable piston speed is:
In cases of high piston speed, the use of an auto switch (D­F5NT/F7NT/G5NT and M5T) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time.
4. Wiring should be kept as short as possible.
<Reed switches> As the length of the wiring to a load gets longer, the rush current at switching ON becomes greater, and this may shorten the product’s life. (The switch will stay ON all the time.)
1) For an auto switch without a connect protection circuit, use
a contact protection box when the wire length is 5 m or longer.
2) Even if an auto switch has a built-in contact protection
circuit, when the wiring is more than 30 m long, it is not able to adequately absorb the rush current and its life may be reduced. It is again necessary to connect a contact protection box in order to extend its life. Please contact SMC in this case.
<Solid state switches>
3) Although wire length should not affect switch function, use a
wire 100 m or shorter.
5. Use caution to the internal voltage drop of a switch.
<Reed switches>
1) Switches with an indicator light (Except D-A56/A76H/A96/
A96V/C76/E76A/Z76)
• If auto switches are connected in series as shown below,
take note that there will be a large voltage drop because of internal resistance in the light emitting diodes. (Refer to internal voltage drop in the auto switch specifications.) [The voltage drop will be “n” times larger when “n” auto switches are connected.] Even though an auto switch operates normally, the load may not operate.
• Similarly, when operating below a specified voltage, it is possible that the load may be ineffective even though the auto switch function is normal. Therefore, the formula below should be satisfied after confirming the minimum operating voltage of the load.
2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator for right (MODEL D-A6/A80/A80H/A90/A90V/C80/R80/90/E80A/ Z80)
<Solid state switches>
3) Generally, the internal voltage drop will be greater with a 2­wire solid state auto switch than with a reed switch. Take the same precautions as in 1). Also note that a 12 VDC relay is not applicable.
6. Use caution to the leakage current.
<Solid state switches> With a 2-wire solid state auto switch, current (leakage current) flows to the load to operate the internal circuit even when in the OFF state.
If the condition given in the above formula is not met, it will not reset correctly (stays ON). Use a 3-wire switch if this specification cannot be satisfied. Moreover, leakage current flow to the load will be “n” times larger when “n” auto switches are connected in parallel.
7. Do not use a load that generates surge voltage.
<Reed switches> If driving a load such as a relay that generates a surge voltage, use a switch with a built-in contact protection circuit or use a contact protection box. <Solid state switches> Although a zener diode for surge protection is connected at the output side of a solid state auto switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element.
8. Cautions for use in an interlock circuit
When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the auto switch. Also perform periodic maintenance inspections and confirm proper operation.
9. Ensure sufficient space for maintenance activities.
When designing an application, be sure to allow sufficient space for maintenance and inspection.
Design and Selection
V (mm/s) =
Auto switch operating range (mm)
Load operating time (ms)
x 1000
Load
Supply voltage
Internal voltage drop of switch
>
Minimum operating voltage of load
Current to operate load (OFF condition) > Leakage current
Warning
Auto Switches
Precautions 1
Be sure to read before handling. For detailed precautions on every series, refer to main text.
2
12-13-2
Page 3
Auto Switches
Precautions 2
Be sure to read before handling. For detailed precautions on every series, refer to main text.
3
Mounting and Adjustment
Warning
1. Do not drop or bump.
Do not drop, bump, or apply excessive impacts (300 m/s2 or more for reed switches and 1000 m/s switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction.
2
or more for solid state
2. Do not carry a cylinder by the auto switch lead wires.
Never carry a cylinder by its lead wires. This may not only cause broken lead wires, but it may cause internal elements of the switch to be damaged by the stress.
3. Mount switches using the proper tightening torque.
When a switch is tightened beyond the range of fastening torque, the mounting screws or switch may be damaged. On the other hand, tightening below the range of fastening torque may alllow the switch to slip out of position. (Refer to switch mounting for each series regarding switch mounting, moving, and fastening torque, etc.)
4. Mount a switch at the center of the operating range.
Adjust the mounting position of an auto switch so that the piston stops at the center of the operating range (the range in which a switch is ON). (The mounting positions shown in the catalog indicate the optimum position at the stroke end.) If mounted at the end of the operating range (around the borderline of ON and OFF), the operation will be unstable.
Wiring
Warning
1. Avoid repeatedly bending or stretching lead wires.
Broken lead wires will result from repeatedly applying bending stress or stretching force to the lead wires.
2. Be sure to connect the load before power is applied.
<2-wire type> If the power is turned on when an auto switch is not connected to a load, the switch will be instantly damaged because of excess current.
3. Confirm proper insulation of wiring.
Be certain that there is no faulty wiring insulation (contact with other circuits, ground fault, improper insulation between terminals, etc.). Damage may occur due to excess current flow into a switch.
4. Do not wire with power lines or high voltage lines.
Wire separately from power lines or high voltage lines, avoiding parallel wiring or wiring in the same conduit with these lines. Control circuits including auto switches may malfunction due to noise from these other lines.
5. Do not allow short circuiting of loads.
<Reed switches> If the power is turned on with a load in a short circuited condition, the switch will be instantly damaged because of excess current flow into the switch.
<Solid state switches> Model D-F9(Y)/F9W(V)/J51/G5NB and all models of PNP output switches do not have built-in short circuit prevention circuits. If loads are short circuited, the switches will be instantly damaged. Use caution to avoid reverse wiring with the brown [red] power supply line and the black [white] output line on 3-wire type switches.
6. Avoid incorrect wiring.
<Reed switches>
A 24 VDC switch with indicator light has polarity. The brown lead wire or terminal no. 1 is (+), and the blue lead wire or
terminal no. 2 is (–). [In the case of model D-97, the side without indicator is (+), and the black line side is (–).]
1) If connections are reversed, a switch will operate, however,
the light emitting diode will not light up.
Also note that a current greater than the maximum
specified one will damage a light emitting diode and make it
inoperable.
Applicable models:
D-A73/A73H/A73C/C73/C73C/E73A/Z73/R73
D-97/93A/A93/A93V
D-A33/A34/A33A/A34A/A44/A44A
D-A53/A54/B53/B54
2) However, when using a two color indication auto switch, the
switch (D-A79W/A59W/B59W), be aware that the switch
will constantly remain ON if the connections are reversed. <Solid state switches>
1) If connections are reversed on a 2-wire type switch, the
switch will not be damaged if protected by a protection
circuit, but the switch will always stay in an ON state.
However, it is still necessary to avoid reversed connections,
since the switch could be damaged by a load short circuit in
this condition.
2) If connections are reversed (power supply line (+) and
power supply line (–) on a 3-wire type switch, the switch will
be protected by a protection circuit. However, if the power
supply line (+) is connected to the blue (black) wire and the
power supply line (–) is connected to the black (white) wire,
the switch will be damaged.
Lead wire color changes
Lead wire colors of SMC auto switches have been changed in order to meet NECA Standard 0402 for production beginning September, 1996 and thereafter. Please refer to the tables provided.
2-wire 3-wire
Old
Red
Black
White
Yellow
New
Brown
Blue
New
Brown
Blue
Black
Orange
Power supply (+) Power supply GND Output
Solid State with Latch Type Diagnostic Output
Power supply (+) Power supply GND Output Latch type
diagnostic output
Old Output (+) Output (–)
Red
Black
Solid State with Diagnostic Output
Power supply (+) Power supply GND Output Diagnostic output
Old
Red Black White
Old
Red Black White
Yellow
New
Brown
Blue
Black
New
Brown
Blue
Black
Orange
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
12-13-3
Page 4
1. Never use in the presence of explosive gases.
The construction of our auto switches does not make them explosion-proof. Never use them in the presence of an explosive gas, as this may cause a serious explosion.
2. Do not use in an area where a magnetic field is generated.
Auto switches will malfunction or magnets inside cylinders will become demagnetized. (Please consult with SMC regarding the availability of a magnetic field resistant auto switch.)
3. Do not use in environments where the auto switches will be constantly exposed to water.
Although switches except D-A3/A44/G39/K39 satisfy the IEC standard IP67 structure (JIS C 0920: anti-immersion structure), do not use switches in applications where continually exposed to water splash or spray. Poor insulation or swelling of the potting resin inside switches may cause malfunction.
4. Do not use in environments with oil or chemicals.
Please consult with SMC if auto switches will be used in an environment with coolants, cleaning solvents, various oils or chemicals. If auto switches are used under these conditions for even a short time, they may be adversely affected by improper insulation, a malfunction due to swelling of the potting resin, or hardening of the lead wires.
5. Do not use in an environment with temperature cycles.
Please consult with SMC if switches are to be used where there are temperature cycles other than normal temperature changes, as they may be adversely affected internally.
6. Do not use in environments where there is excessive impact shock.
<Reed switches> When excessive impact (300 m/s
2
or more) is applied to a reed switch during operation, the contact point may malfunction and generate or cut off a signal momentarily (1 ms or less). Please consult with SMC regarding the need to use a solid state switch depending on the environment.
7. Do not use in locations where surges are generated.
<Solid state switches> When there are units (solenoid type lifters, high frequency induction furnaces, motors, etc.) which generate a large amount of surge in the area around cylinders with solid state auto switches, this may cause deterioration or damage to the switches. Avoid sources of surge generation and crossed lines.
8. Avoid accumulation of iron debris or close contact with magnetic substances.
When a large amount of ferrous debris such as machining chips or spatter is accumulated, or a magnetic substance (something attracted by a magnet) is brought into close proximity with an auto switch cylinder, it may cause the auto switches to malfunction due to a loss of the magnetic force inside the cylinder.
Operating Environment
1. Perform the following maintenance periodically in order to prevent possible danger due to unexpected auto switch malfunction.
1) Securely tighten switch mounting screws.
If screws become loose or the mounting position is dislocated, retighten screws securely after readjusting the mounting position.
2) Confirm that there is no damage to lead wires.
To prevent faulty insulation, replace switches or repair lead wires if damage is discovered.
3) Confirm that the green light on the 2-color indicator type
switch lights up. Confirm that the Green LED is ON when stopped at the set position. If the Red LED is ON when stopped at the set position, the mounting position is not appropriate. Readjust the mounting position until the Green LED lights up.
Maintenance
1. Please consult with SMC concerning water resistance, elasticity of lead wires, and use at welding sites.
Other
Warning
Warning
Warning
Auto Switches
Precautions 3
Be sure to read before handling. For detailed precautions on every series, refer to main text.
4
12-13-4
Page 5

Before Operation

Auto Switches Common Specifications

Precautions

Refer to “Auto Switches Precautions” on pages 12-13-2 to 12-13-4 before handling.
5
Auto Switches Common Specifications
Type
Leakage current
Operating time
Impact resistance
Insulation resistance
Withstand voltage
Ambient temperature
Enclosure
Reed switch
None
1.2 ms
2
300 m/s
50 M or more at 500 M VDC (Between lead wire and case)
1500 VAC for 1 minute
(Between lead wire and case)
IEC529 Standard IP67, Immersible construction (JIS C 0920)
3-wire: 100 µA or less, 2-wire: 0.8 mA or less
(1)
–10 to 60°C
Solid state switch
1 ms or less
1000 VAC for 1 minute
(Between lead wire and case)
Lead Wire Length
Lead wire length indication
(Example)
D-A73
L
Lead wire length
Nil
0.5 m
L
3 m
Applicable for the connector
(Example)
type (D-
C) only.
D-F8PL-
5 m
Z
None
N
Flexible lead wire
specifications
(D-Y59, D-Y69, D-Y7 and D-M9/M9V series use flexible lead wire as srandard. )
Part No. of Lead Wires with Connectors
(Applicable only for connector type)
Model
D-LC05
D-LC30
D-LC50
Lead wire length
0.5 m
3 m
5 m
61
Note 1)
Applicable auto switch with 5 m lead wire (“Z”) Reed switch: D-B53/B54, D­C73(C)/C80C, D-A73(C)(H)/ A80C, D-A53/A54, D-Z73, D­90/97/90A/93A Solid state switch: Manufactured upon receipt of order as standard. The standard lead wire length
Note 2)
of solid state switches with timer, water resistant 2-color indication type, wide range detection type or heat resistant 2-color indication type is 3 meters in length. (0.5 m is not available.)
Note 3)
Lead wire lengths of 3 m and 5 m are standard for magnetic field resistant 2-color indicator type solid state switches. (0.5 m is not available.) Add “-61” at th end of the part
Note 4)
number for the flexible lead wire except D-Y59, D-Y69, D­Y7 and D-M9/M9V type auto switches.
Auto Switch Hysteresis
Hysteresis is the distance between the position at which piston movement operates an auto switch to the position at which reverse movement turns the switch off. This hysteresis is included in part of the operating range (one side).
Auto switch
Note 1)
Electrical entry: Connector type (A73C/A80C/C73C/C80C) and D-9/9
(4)
(3)
2
Note 2)
Note 3)
Note 4)
(2)
Contact Protection Box:
1 <Applicable switch types>
D-A7/A8, D-A7H/A80H, D-A73C/A80C, D-C7/C8, D-C73C/C080C, D­E7A/E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, and D-A79W type The above auto switches do not have internal contact protection circuits.
1. Operating load is an inductive load.
2. The length of wiring to the load is 5 m or more.
3. The load voltage is 100 or 200 VAC. A contact protection box should be used in any of the above conditions, Unless using a contact protection box, the contact life may
be shortened. (Due to permanent energizing conditions.)
D-A72(H) must be used with the contact protection box regardless of load styles and lead wire length.
2
Please contact SMC when using built-in contact protection circuit style (D­A34[A][C], D-A44[A][C], D-A54/A64, D-B54/B64, D-A59W, D-B59W) in the following conditions: 1. The wiring length to load is more than 30 m; 2.
When using PLC with large flow current.
A/A9/A9V type: 1000 VAC/min. (Between
lead wire and the case) The following switches, Terminal conduit type (D­A3/A3
A/A3C/G39/G39A/G39C/K39/K39A/K39C), DIN
terminal type (D-A44/A44A/A44C) and Heat resistant auto switch (D-F7NJL) meet the IEC529 standard. IP63, JIS C 0920 Rainproof construction Except solid state switch with timer (D-M5 G5NTL/F7NTL/F5NTL) and magnetic resistant 2-color indi­cation type solid state switch (D-P5DWL). D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).
TL,
CD-P11, CD-P12
Contact Protection Box Specifications
Part no.
Load voltage
Max. load current
Lead wire length — Switch connection side 0.5 m
CD-P11
100 VAC or less
25 mA
Load connection side 0.5 m
200 VAC
12.5 mA
CD-P12
24 VDC
50 mA
Contact Protection Box Internal Circuit
CD-P11
CD-P12
Surge absorber
Zener diode
Choke
coil
Choke
coil
OUT Brown
~
OUT Blue
OUT (+) Brown
OUT (–) Blue
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
Switch operating position (ON)
Switch operating position (OFF)
Note) Hysteresis may fluctuate due to the operating environment.
Please contact SMC if hysteresis causes an operational problem.
Hysteresis
Reed switch: 2 mm or less Solid state switch: 1 mm or less
Contact Protection Box/Dimensions
Note)
Contact Protection Box Connection
To connect a switch unit to a contact protection box, connect the lead wire from the side of the contact protection box marked SWITCH to the lead wire coming out of the switch unit. Keep the switch as close as possible to the contact protection box, with a lead wire length of no more than 1 meter.
12-13-5
Page 6
Before Operation

Auto Switches Connection and Example

Basic Wiring
Example of Connection with PLC (Programmable Logic Controller)
Example of AND (Series) and OR (Parallel) Connection
Solid state 3-wire, NPN Solid state 2-wireSolid state 3-wire, PNP
Main curcuit of switch
Brown
Black
Blue
Brown
Black
Blue
Brown
Blue
Brown
Blue
Reed switch 2-wire
Indicator protection circuit, etc.
Brown
Blue
~
~
Brown
Blue
Indicator protection circuit, etc.
• Sink input specifications 3-wire, NPN
• Source input specifications 3-wire, PNP
2-wire
Switch
Input
Black
COM
Brown
Blue
2-wire
Switch
Input
Black
PLC internal circuit
COM
Brown
Blue
PLC internal circuit
PLC internal circuit
Switch
Input
Blue
COM
Brown
PLC internal circuit
Switch
Input
Blue
COM
Brown
• 3-wire
OR connection for NPN output
2-wire with 2-switch AND connection 2-wire with 2-switch OR connection
Load voltage at ON = Power supply voltage – Residual voltage x 2 pcs.
= 24 V – 4 V x 2 pcs. = 16 V
Example: Power supply is 24 VDC
Internal voltage drop in switch is 4 V.
Load voltage at OFF = Leakage current x 2 pcs. x Load impedance
= 1 mA x 2 pcs. x 3 k = 6 V
Example: Load impedance is 3 k.
Leakage current from switch is 1 mA.
Switch 2
Switch 1
Load
Brown Black Blue
Brown Black Blue
Switch 1
Brown
Switch 2
Black Blue
Relay
Relay
Brown Black Blue
Load
Relay contact
Switch 1
Switch 2
Brown
Blue
Brown
Blue
Load
Switch 1
Switch 2
Brown
Blue
Brown
Blue
Load
AND connection for NPN output (Using relays)
• 2-wire
Switch 1
Brown
Switch 2
Black Blue
Load
Brown Black Blue
AND connection for NPN output (Performed with switches only)
The indicator lights will light up when both switches are turned ON.
When two switches are connected in series, a load may malfunction because the load voltage will decline when in the ON state. The indicator lights will light up when both of the switches are in the ON state.
(Solid state switch)
When two switches are connected in parallel, malfunction may occur because the load voltage will increase when in the OFF state.
(Reed switch)
Because there is no current leakage, the load voltage will not increase when turned OFF. However, depending on the number of switches in the ON state, the indicator lights may sometimes grow dim or not light up, due to the dispersion and reduction of the current flowing to the switches.
Brown
Black
Blue
Main curcuit of switch
Main curcuit of switch
Main curcuit of switch
Main curcuit of switch
Connect according to the applicable PLC input specifications, as the connection method will vary depending on the PLC input specifications.
(Power supply for switch and load are separate)
Load
Load
Load
Load
Load
Load
Load
6
12-13-6
Page 7
Reed Switch Band Mounting Style
D-A72/D-A73/D-A80
For details about certified products conforming to international standards, visit us at www.smcworld.com.
7
Grommet
Electrical entry: Perpendicular
Auto Switch Internal Circuit
D-A72
Contact protection box
LED
Resistor
Zener diode

Reed switch

Brown
Blue
CD-P11
Choke coil
Surge absorber
OUT Brown
OUT Blue
D-A73
LED
Resistor
Zener diode
Reed switch
Brown
Blue
Contact protection box CD-P11 CD-P12
OUT ( Brown
OUT (–) Blue
D-A80
OUT (±) Brown
OUT ( ) Blue
±
Reed switch
Contact protection box CD-P11 CD-P12
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
D-A7 (With indicator light)
Auto switch model
Applicable load
Load voltage
Load current range
Contact protection circuit
Internal voltage drop
Indicator light
(3)
D-A8 (Without indicator light)
Auto switch model
Applicable load
Load voltage
Maximum load current
Contact protection circuit
Internal resistance
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm Note 1) Regarding the common specifications of the reed switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
D-A72
Relay, PLC
200 VAC
5 to 10 mA
24 VDC
5 to 40 mA
None
2.4 V or less
Red LED lights when ON.
D-A73
Relay, PLC
D-A80
AC
24 V or less
DC
50 mA 20 mA
1 or less (Including lead wire length of 3 m)
Relay, IC circuit, PLC
AC
48 V
DC
40 mA
None
2
, 2 cores (Brown, Blue), 0.5 m
100 VAC
5 to 20 mA
AC
100 V
DC
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
Weight
D-
(g)
Auto switch model
Lead wire length
+)
(m)
0.5
3
5
D-A72
10
47
D-A73 D-A80
10
47
77
10
47
20-
Dimensions
Indicator light
D-A80 without
indicator light
15 (14)
23 (22)
Note 1) Operating load is an induction load. Note 2) Wiring to the load is 5 m or longer. Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 12-13-5 for contact protection box.)
6 (6.2) 3
9 (8.5)
( ) values for D-A72
Most sensitive position
12-13-7
Page 8
Indicator light D-A80H without
indicator light
Most sensitive position
Auto Switch Internal Circuit
D-A72H
D-A73H
D-A76H
D-A80H
Auto Switch Specifications
Dimensions
Auto switch model
0.5
3
5
10
47 —
10
47 —
11
52 —
10
47
77
D-A72H D-A73H D-A76H
D-A80H
D-A7H, D-A80H
Grommet
Electrical entry: In-line
Lead wire length
(m)
PLC: Abbreviation of Programmable Logic Controller
D-A7H (With indicator light)
Auto switch model
Applicable load
Load voltage
Max. load voltage/Load current range
(3)
Contact protection circuit
Internal voltage drop
Indicator light
24 VDC
5 to 40 mA
2.4 V or less
100 VAC
5 to 20 mA
D-A72H
Relay, PLC
200 VAC
5 to 10 mA
D-A76H
IC circuit
4 to 8 VDC
20 mA
0.8 V or less
D-A73H
Relay, PLC
None
Red LED lights when ON.
D-A80H
Relay, IC circuit, PLC
40 mA
None
1 or less (Including lead wire length of 3 m)
D-A80H (Without indicator light)
Auto switch model
Applicable load
Load voltage
Maximum load current
Contact protection circuit
Internal resistance
50 mA 20 mA
24 V or less
AC DC
48 V
AC DC
100 V
AC DC
LED
Reed switch
Resistor
Zener diode
Brown
Blue
OUT
(+)
Brown
OUT () Blue
LED
Reed switch
Resistor
Reverse current prevention diode
OUT Black
DC
(+)
Brown
DC
()
Blue
Load
(+)
(
)
DC power supply
Blue
LED
Reed switch
Resistor
Zener diode
Brown
OUT Blue
OUT Brown
Choke coil
Contact protection box
CD-P11
Surge absorber
Reed switch
OUT (±) Brown
Note 1) Operating load is an induction load. Note 2) In the case the wiring length to load is
more than 5 m. Note 3) Wiring to the load is 5 m or longer. Use the contact protection box in any of the above listed situations. The contact point life may decrease. Especially in the case of
D-A72H, be sure to use the contact protection box. (Refer to page 12-13-5 for
contact protection box.)
• Lead wire — Oil resistant vinyl heavy-duty cord, 0.2 mm2, 2 cores (Brown, Blue), 3 cores (Brown, Black, Blue), 0.5 m
Note 1) Regarding the common specifications of the reed switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
Reed Switch Rail Mounting Style
D-A7
H/D-A80H
OUT ( ) Blue
±
Contact protection box CD-P11 CD-P12
Contact protection box CD-P11 CD-P12
Weight
(g)
For details about certified products conforming to international standards, visit us at www.smcworld.com.
8
12-13-8
Page 9
Reed Switch Rail Mounting Style
D-A73C/D-A80C
For details about certified products conforming to international standards, visit us at www.smcworld.com.
9
Connector
Caution
Precautions
1. Confirm that the connector is appropriately
tightened. If tightened insufficiently, the waterproof performance will deteriorate.
2. Refer to Best Pneumatics Vol. 6/7/8/9/10 for the details.
Auto Switch Internal Circuit
D-A73C
LED
Resistor
Zener diode
Reed switch
D-A80C
Contact protection box
CD-P12
Brown
Blue
Choke coil
Zener diode
OUT (+) Brown
()
OUT Blue
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
D-A73C (With indicator light)
Auto switch model
Applicable load
Load voltage
Load current range
Contact protection circuit
Internal voltage drop
Indicator light
(4)
D-A73C
Relay, PLC
24 VDC
5 to 40 mA
None
2.4 V or less
Red LED lights when ON.
D-A80C (Without indicator light)
Auto switch model
Applicable load
Load voltage
Maximum load current
Contact protection circuit
Internal resistance
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m Note 1) Regarding the common specifications of the reed switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5. Note 3) Lead wire with connector may be shipped with switch. Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
1 or less (Including lead wire length of 3 m)
D-A80C
Relay, IC circuit, PLC
24 V
50 mA
None
AC
DC
Weight
(g)
Auto switch model
Lead wire length
(m)
0.5
3
5
D-A73C
12
54
84
D-A80C
12
54
84
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
Contact protection box CD-P11
Reed switch
Note 1) Operating load is an induction load. Note 2) Wiring to the load is 5 m or longer. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 12-13-5 for contact protection box.)
CD-P12
(±)
OUT Brown
OUT ( ) Blue
±
Dimensions
Lead wire with connector
Indicator light D-A80C without
indicator light
Most sensitive position
12-13-9
Page 10
( ): dimensions for D-A93.
D-A90V, D-A93V, D-A96V
Auto Switch Specifications
Grommet
Electrical entry: In-line
PLC: Abbreviation of Programmable Logic Controller
D-A90, D-A90V (Without indicator light)
Auto switch model
Applicable load
Load voltage
Maximum load current
Contact protection circuit
Internal resistance
D-A93, D-A93V, D-A96, D-A96V (With indicator light)
Auto switch model
Applicable load
Load voltage
Load current range and Maximum load current
Contact protection circuit
Internal voltage drop
Indicator light
D-A90, D-A90V
IC circuit, Relay, PLC
24 V or less
50 mA
None
1 or less (Including lead wire length of 3 m)
48 V or less
40 mA
100 V or less
20 mA
D-A93, D-A93V
Relay, PLC
24 VDC
5 to 40 mA
None
D-A93 —— 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V —— 2.7 V or less
Red LED lights when ON.
100 VAC
5 to 20 mA
D-A96, D-A96V
IC circuit
4 to 8 VDC
20 mA
0.8 V or less
AC DC
AC DC
AC DC
Note 1) Operating load is an induction load. Note 2) Wiring to the load is 5 m or longer. Note 3) Load voltage is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 12-13-5 for contact protection box.)
1. Fix the switch with appropriate screw installed on the switch body. If using other screws, switch may be damaged.
Model
Lead wire length: 0.5 m
Lead wire length: 3 m
D-A90
6
30
D-A90V
6
30
D-A93
6
30
D-A93V
6
30
D-A96
8
41
D-A96V
8
41
(g)
Weight
Auto Switch Internal Circuit Colors of lead wire inside ( ) are the ones before conformed to IEC standard.
D-A90V
D-A93V
D-A96V
Reed switch
OUT(±) Brown
OUT (±) Blue
Blue (Black)
LED
Reed switch
Resistor
Zener diode
Brown (Red)
OUT (+) Brown
OUT () Blue
LED
Reed switch
Resistor
Reverse current prevention diode
OUT Black
DC (+)
Brown
DC (
)
Blue
Load
(+)
(
)
DC power supply
Dimensions
D-A90, D-A93, D-A96
(3)
• Lead wire D-A90(V)/D-A93(V)—Oil resistant vinyl heavy-duty cord, ø2.7, 0.18 mm2 x 2 cores (Brown, Blue), 0.5 m D-A96(V)—
Oil resistant vinyl heavy-duty cord, ø2.7, 0.15 mm2 x 3 cores (Brown, Black, Blue), 0.5 m Note 1) Regarding the common specifications of the reed switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5. Note 3)
Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
M2.5 x 4
l
Slotted set screw
Indicator light
D-A90 without indicator light
Indicator light
D-A90V without indicator light
M2.5 x 4l Slotted set screw
Most sensitive position
Reed Switch Direct Mounting Style
D-A90(V)/D-A93(V)/D-A96(V
)
Contact protection box CD-P11 CD-P12
Contact protection box CD-P11 CD-P12
Most sensitive
position
Precautions
Caution
For details about certified products conforming to international standards, visit us at www.smcworld.com.
10
12-13-10
Page 11
2-color Indication Type Reed Switch Rail Mounting Style
D-A79W
For details about certified products conforming to international standards, visit us at www.smcworld.com.
11
Grommet
The optimum operating position can be determined by the color of the light. (Red Green Red)
Auto Switch Internal Circuit
D-A79W
(+)
OUT
Reed switch
of switch
Main circuit
LED
Brown
Reverse flow prevent diode
OUT () Blue
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
D-A79W (With indicator light)
Auto switch model
Applicable load
Load voltage
Load current range
Contact protection circuit
Internal voltage drop
Indicator light
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m Note 1) Regarding the common specifications of the reed switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the
indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more.
(3)
Operating position······Red LED lights when ON.
Optimum operating position······Green LED lights when ON.
D-A79W
Relay, PLC
24 VDC
5 to 40 mA
None
4 V or less
Weight
(g)
Auto switch model
Lead wire length
(m)
0.5
3
5
D-A79W
11
53 —
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
Indicator light/Display method
Operating range
Indication
Green
Red Red
Optimum operating position
Note 1) Operating load is an induction load. Note 2) Wiring to the load is 5 m or longer. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 12-13-5 for contact protection box.)
D-
Dimensions
20-
Most sensitive position
12-13-11
Page 12
Auto Switch Internal Circuit
D-F79
D-J79
D-F7P
Auto Switch Specifications
Weight
Dimensions
Auto switch model
0.5
3
5
D-F79
D-F7P D-J79
Grommet
Lead wire length
(m)
D-F7, D-J79 (With indicator light)
PLC: Abbreviation of Programmable Logic Controller
Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-F79
NPN
28 VDC or less
40 mA or less
1.5 V or less
(0.8 V or less
at 10 mA load current)
D-F7P
PNP
80 mA or less
0.8 V or less
Red LED lights when ON.
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
100 µA or less at 24 VDC
D-J79
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
13
57
92
11
50
81
13
57
92
• Lead wire — Oil resistant vinyl heavy-duty cord,
ø3.4, 0.2 mm
2
, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5 m Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
Indicator light
Most sensitive position
ø3.5 mounting hole
(g)
Solid State Switch Rail Mounting Style
D-F79/D-F7P/D-J79
Main circuit
of switch
OUT Black
DC (
+)
Brown
DC (
)
Blue
OUT Black
DC (
+)
Brown
DC (
)
Blue
OUT (
+)
Brown
OUT (–) Blue
Main circuit
of switch
Main circuit
of switch
For details about certified products conforming to international standards, visit us at www.smcworld.com.
12
12-13-12
Page 13
Solid State Switch Rail Mounting Style
D-F7NV/D-F7PV/D-F7BV
For details about certified products conforming to international standards, visit us at www.smcworld.com.
13
Grommet
Electrical entry: Perpendicular
Auto Switch Internal Circuit
D-F7NV
DC (
+)
Brown
OUT
of switch
Main circuit
Black
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
D-F7V (With indicator light)
Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
D-F7NV
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
1.5 V or less
(0.8 V or less
at 10 mA load current)
100 µA or less at 24 VDC
D-F7PV
3-wire
PNP
80 mA or less
0.8 V or less
Red LED lights when ON.
D-F7BV
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Weight
Auto switch model
Lead wire length
(m)
0.5
3
5
D-F7NV
13
57
92
D-F7PV D-F7BV
13
57
92
11
50
81
(g)
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
D-F7PV
D-F7BV
of switch
Main circuit
of switch
Main circuit
DC (
)
Blue
DC ( Brown
OUT Black
DC (
)
Blue
OUT ( Brown
OUT (–) Blue
Dimensions
ø3.5 mounting hole
Indicator light
+)
+)
Most sensitive position
12-13-13
Page 14
Auto Switch Internal Circuit
D-J79C
Auto switch model
0.5
3
5
13
52
83
D-J79C
Connector
Lead wire length
(m)
D-J79C
Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-J79C
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Red LED lights when ON.
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 0.5 m Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
Weight
(g)
Dimensions
1. Confirm that the connector is appropriately
tightened. If tightened insufficiently, the waterproof performance will deteriorate.
2. Refer to Best Pneumatics Vol. 6/7/8/9/10 for the details.
Precautions
Solid State Switch Rail Mounting Style
D-J79C
Main circuit
of switch
OUT (+) Brown
OUT (–) Blue
ø3.2 mounting hole
Indicator light
Most sensitive position
Caution
For details about certified products conforming to international standards, visit us at www.smcworld.com.
14
12-13-14
Page 15
Solid State Switch Direct Mounting Style
D-F8N/D-F8P/D-F8B
For details about certified products conforming to international standards, visit us at www.smcworld.com.
15
Grommet
Caution
Precautions
Fix the switch with appropriate screw installed on the switch body. If using other screws, switch may be damaged.
Auto Switch Internal Circuit
D-F8N
+)
DC ( Brown
OUT
of switch
Main circuit
Black
DC ( Blue
)
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
I
nternal voltage drop
Leakage current
Indicator light
• Lead wire ——— Oil resistant vinyl heavy-duty cord, ø2.7, 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
D-F8N, D-F8P 0.15 mm D-F8B
D-F8N
Perpendicular
NPN
IC circuit, 24 VDC Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
1.5 V or less
(0.8 V or less
at 10 mA load current)
100 µA or less at 24 VDC
2
0.18 mm
2
x 2 cores (Brown, Blue)
D-F8P
Perpendicular
3-wire
PNP
80 mA or less
0.8 V or less
Red LED lights when ON.
x 3 cores (Brown, Black, Blue)
D-F8B
Perpendicular
2-wire
24 VDC relay, PLC
24 VDC (10 to 28 VDC)
2.5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Weight
Auto switch model
Lead wire length
(m)
0.5
3
5
D-F8N
7
32
52
D-F8P
7
32
52
D-F8B
7
32
52
Dimensions
(g)
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
D-F8P
D-F8B
of switch
Main circuit
of switch
Main circuit
DC ( Brown
OUT Black
DC (
)
Blue
OUT ( Brown
OUT (–) Blue
D-F8N, D-F8P, D-F8B
+)
10.9 3
+)
3.1
4.3
2
ø2.7
2.8
4
Mounting screw M2.5 x 4l
Indicator light
10
4.6
Most sensitive position
8
Slotted set screw
12-13-15
Page 16
Auto Switch Internal Circuit
D-M9N, D-M9NV
D-M9B, D-M9BV
D-M9P, D-M9PV
Auto switch model
0.5
3
5
D-M9N(V)
8
41
68
D-M9P(V)
8
41
68
D-M9B(V)
7
38
63
Lead wire length
(m)
• Lower load current
• Lead free solder
• Using UL certified (style
2844) lead wire
Grommet
D-M9, D-M9V (With indicator light)
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-M9N
In-line
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 V)
28 VDC or less
D-M9NV
Perpendicular
D-M9BV
Perpendicular
D-M9PV
Perpendicular
D-M9B
In-line
2-wire
24 VDC relay, PLC
24 VDC (10 to 28 VDC)
2.5 to 40 mA
4 V or less
0.8 mA or less
D-M9P
In-line
PNP
10 mA or less
Red LED lights when ON.
100 µA or less at 24 VDC
D-M9V
D-M9
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
Weight
(g)
Dimensions
Lead wire — Oil resistant vinyl heavy-duty cord, ø2.7 x 3.2 ellipse 0.15 mm2, 2 cores (D-M9B), 3
cores (D-M9N, D-M9P) Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
Solid State Switch Direct Mounting Style
D-M9N(V)/D-M9P(V)/D-M9B(V
)
Main circuit
of switch
Main circuit
of switch
Main circuit
of switch
OUT Black
DC (
+)
Brown
DC (
)
Blue
OUT Black
DC (
+)
Brown
DC (
)
Blue
OUT (
+)
Brown
OUT (–) Blue
40 mA or less
0.8 V or less
Precautions
During installation, secure the rod cover and tighte
• Over-current protection is not equipped with this product series. When it is wired incorrectly or a load is short-circuited, a switch may be damaged or burned.
• In the event of stripping cable sheath, use caution for the stripping direction.
Its insulation may be torn or damaged, depending on the direction.
• Below is given as the recommended tool.
As for 2-wire, a stripper for round shape cord (ø2.0) is usable.
• Fix the switch with appropriate screw installed on the switch body. If using other screws, switch may be damaged.
Caution on Handling
Caution
Be sure to read before handling. Please contact SMC when using beyond specifications.
Maker
Product’s name
Part no. VESSEL Co., Inc. Tokyo Ideal Co., Ltd.
Wirestripper
Stripmaster
No 3000G
45-089
Operating range shortened, compared to conventional types.
When replacing conventional types, dependant upon application, the shortened operating range may cause auto switch imperceptive.
• When the range of stroke is wider than the operating range. Example) Stamping, press-fitting, clamping, etc.
• When used to detect intermediate position. (Detection output time is shortened.)
Note) Please consult with SMC regarding details of
operation range by each actuator.
Since short circuit protection circuit is not built-in, the auto switch will be immediately damaged when the load is short­circuited. Be careful not to exchange the power cable (brown) with the output cable (black).
For details about certified products conforming to international standards, visit us at www.smcworld.com.
2.6
4
2.8
M2.5 x 4l slotted set screw
Indicator light
2.7
22
500 (3000)
2.6
4
9.5
500 (3000) (5000)
2.7
4.6
2
20
M2.5 x 4l Slotted set screw
2.8
8
3.2
4
6
Indicator light
Most sensitive position
3.2
22
500 (3000)
6
Most sensitive position
16
12-13-16
Page 17
Solid State Switch Direct Mounting Style
A
D-Y59 /D-Y69 /D-Y7P(V
B
A
B
)
For details about certified products conforming to international standards, visit us at www.smcworld.com.
17
Grommet
Auto Switch Internal Circuit
D-Y59A, D-Y69A
DC ( Brown
OUT
of switch
Main circuit
Black
DC ( Blue
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
D-Y5, D-Y6, D-Y7P, D-Y7PV (With indicator light)
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.15 mm
Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
D-Y59A
In-line
28 VDC or less
at 10 mA load current)
2 cores (Brown, Blue), 0.5 m
D-Y69A
Perpendicular
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 V)
10 mA or less
40 mA or less
1.5 V or less (0.8 V or less
100 µA or less at 24 VDC
D-Y7P
In-line
Red LED lights when ON.
D-Y7PV
Perpendicular
PNP
80 mA or less
0.8 V or less
2
, 3 cores (Brown, Black, Blue),
D-Y59B
In-line
24 VDC relay, PLC
24 VDC (10 to 28 VDC)
0.8 mA or less at 24 VDC
D-Y69B
Perpendicular
2-wire
5 to 40 mA
4 V or less
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
+)
Weight
Auto switch model
Lead wire length
(m)
)
D-Y59B D-Y69B
0.5
3
5
9
50
83
D-Y59A D-Y69A
10
53
87
D-Y7P(V)
10
53
87
MRHQ
(g)
Misc.
D-
20-
D-Y7P, D-Y7PV
of switch
Main circuit
D-Y59B, D-Y69B
of switch
Main circuit
+)
DC ( Brown
OUT Black
)
DC ( Blue
OUT (+) Brown
OUT (–) Blue
Dimensions
D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B
Mounting screw M2.5 x 4
Slotted set screw
SMCSMC
27.3
Most sensitive position
12.5
Indicator light
ø3.4
8.5
2.5
6.2
5
Mounting screw M2.5 x 4l Slotted set screw
Indicator light
SMC
29
Most sensitive position
12.5
2.5
6.2
ø3.4
5
l
12-13-17
Page 18
Auto switch model
0.5
3
5
13
57
92
13
57
92
11
50
81
D-F79W
D-F7PW D-J79W
Lead wire length
(m)
Auto Switch Internal Circuit
D-F79W
D-J79W
Indicator light/Display method
D-F7PW
Grommet
D-F7W, D-J79W
Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-F79W
3-wire
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
100 µA or less at 24 VDC
Operating position······Red LED lights when ON.
Optimum operating position······Green LED lights when ON.
D-J79W
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
D-F7PW
PNP
80 mA
0.8 V or less
1.5 V or less
(0.8 V or less
at 10 mA load current)
• Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 3 cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.5 m
Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
The optimum operating position can be determined by the color of the light. (Red Green Red)
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
Weight
(g)
Dimensions
Operating range
Indication
GreenRed Red
Optimum operating position
ø3.2 mounting hole
Indicator light
Most sensitive position
2-color Indication Type Solid State Switch Rail Mounting Style
D-F79W/D-F7PW/D-J79W
Main circuit
of switch
Main circuit
of switch
Main circuit
of switch
OUT (+) Brown
OUT (–) Blue
OUT Black
DC (
+)
Brown
DC (
)
Blue
OUT Black
DC (
+)
Brown
DC (
)
Blue
For details about certified products conforming to international standards, visit us at www.smcworld.com.
18
12-13-18
Page 19
2-color Indication Type Solid State Switch Direct Mounting Style
19
D-Y7NW(V)/D-Y7PW(V)/D-Y7BW(V
Grommet
The optimum operating position can be determined by the color of the light.
Auto Switch Internal Circuit
D-Y7NW, D-Y7NWV
D-Y7PW, D-Y7PWV
(Red Green Red)
of switch
Main circuit
DC ( Brown
OUT Black
DC ( Blue
+)
)
DC ( Brown
+)
For details about certified products conforming to international standards, visit us at www.smcworld.com.
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
D-Y7W, D-Y7WV (With indicator light)
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
• Lead wire —
Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
D-Y7NW
In-line
at 10 mA load current)
Oil resistant, flexible vinyl heavy-duty cord, ø3.4, 0.15 mm2, 3 cores (Brown, Black, Blue),
2 cores (Brown, Blue), 0.5
D-Y7NWV
Perpendicular
NPN
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 VDC)
10 mA or less
28 VDC or less
40 mA or less
1.5 V or less
(0.8 V or less
100 µA or less at 24 VDC
Operating position······Red LED lights when ON.
Optimum operating position······Green LED lights when ON.
D-Y7PW
In-line
3-wire
m
D-Y7PWV
Perpendicular
PNP
80 mA or less
0.8 V or less
D-Y7BW
In-line
24 VDC relay, PLC
24 VDC (10 to 28 VDC)
0.8 mA or less at 24 VDC
D-Y7BWV
Perpendicular
2-wire
5 to 40 mA
4 V or less
Weight
Auto switch model
Lead wire length
(m)
0.5
3
5
D-Y7NW(V)
11
54
88
D-Y7PW(V)
11
54
88
D-Y7BW(V)
11
54
88
)
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
(g)
Misc.
D-
20-
OUT
of switch
Main circuit
Black
DC ( Blue
)
D-Y7BW, D-Y7BWV
+)
OUT ( Brown
of switch
Main circuit
OUT (–) Blue
Indicator light/Display method
Operating range
Indication
Green
Red Red
Optimum operating position
Dimensions
D-Y7W
D-Y7WV
2.5
2.5
6.2
5
6.2
5
Mounting screw M2.5 x 4l Slotted set screw
Indicator light
SMC
29
Most sensitive position
12.5
Mounting screw M2.5 x 4l
Slotted set screw
Indicator light
SMC
27.3
12.5
Most sensitive position
ø3.4
ø3.4
8.5
12-13-19
Page 20
Auto Switch Internal Circuit
D-F9NW, D-F9NWV
D-F9BW, D-F9BWV
D-F9PW, D-F9PWV
Grommet
D-F9W, D-F9WV (With indicator light)
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-F9NW
In-line
D-F9NWV
Perpendicular
D-F9PW
In-line
D-F9PWV
Perpendicular
D-F9BW
In-line
D-F9BWV
Perpendicular
3-wire
IC circuit, Relay, PLC
5, 12, 24 VDC (4.5 to 28 V)
10 mA or less
100 µA or less at 24 VDC
NPN
28 VDC or less
40 mA or less
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less
80 mA or less
0.8 V or less
PNP
Operating position······Red LED lights when ON.
Optimum operating position······Green LED lights when ON.
1.5 V or less
(0.8 V or less
at 10 mA load current)
Mounting screw M2.5 x 4l
Slotted set screw
2
2.8
22
ø2.7
Indicator light
2.6 4
Most sensitive position
6
Mounting screw M2.5 x 4
l
Slotted set screw
Indicator light
4.3
2
3.8
3.1
6.2
4
ø2.7
Most sensitive position
6
4.6
2.8
20
D-F9WV
D-F9W
Indicator light/Display method
Auto switch model
0.5
3
5
D-F9NW(V)
7
34
56
D-F9PW(V)
7
34
56
D-F9BW(V)
7
32
52
Lead wire length
(m)
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
• Lead wire — Oil resistant vinyl heavy-duty cord: ø2.7, 3 cores (Brown, Black, Blue), 0.15 mm
2
2 cores (Brown, Blue) 0.18 mm
2
, 0.5 m Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
Weight
(g)
Dimensions
Operating range
Indication
Green
Red Red
Optimum operating position
2-color Indication Type Solid State Switch Direct Mounting Style
D-F9NW(V)/D-F9PW(V)/D-F9BW(V
)
Main circuit
of switch
Main circuit
of switch
Main circuit
of switch
OUT Black
DC (
+)
Brown
DC (
)
Blue
OUT Black
DC (
+)
Brown
DC (
)
Blue
OUT (
+)
Brown
OUT (–) Blue
For details about certified products conforming to international standards, visit us at www.smcworld.com.
20
12-13-20
Page 21
21

2-color Indication Type with Diagnostic Output Solid State Switch: Rail Mounting Style

D-F79F
For details about certified products conforming to international standards, visit us at www.smcworld.com.
Grommet
Since the output signal can be detected in an unsteady detecting area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller).
Auto Switch Internal Circuit
+)
DC ( Brown
OUT (Normal output) Black
Diagnosis OUT (Diagnostic output)
of switch
Main circuit
Orange
DC ( Blue
)
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
D-F79F (With indicator light)
Auto switch model
Wiring
Output
Diagnostic output
Applicable load
Power voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Current leakage
Indicator light
Lead wire Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
— Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 4 cores (Brown, Black, Orange, Blue), 0.5 m
50 mA or less at the total amount of normal output and diagnostic output
Optimum operating position······Green LED lights when ON.
5, 12, 24 VDC (4.5 to 28 VDC)
1.5 V or less (0.8 V or less at 5 mA)
Operating position······Red LED lights when ON.
D-F79F
4-wire
NPN
Normal operation
IC circuit, Relay, PLC
10 mA or less
28 VDC or less
100 µA or less at 24 VDC
Weight
Auto switch model
Lead wire length
(m)
0.5
3
5
D-F79F
13
56
90
Diagnostic Output Operation
The diagnostic signal is output within unsteady detecting area (where indicator light is Red), and the diagnostic output becomes OFF when the detecting position remains within the optimum operating position (where indicator is Green). When the detecting position is not adjusted, the diagnostic output becomes ON.
Indicator light
OUT (Normal output)
Diagnosis OUT (Diagnostic output)
OFF OFF
ON
Red Green Red
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
(g)
MRHQ
Misc.
D-
20-
Red
Dimensions
ø3.2 mounting hole
Indicator light
ø3.4
Most sensitive position
12-13-21
Page 22
Auto Switch Internal Circuit
Dimensions
Grommet
Water (coolant) resistant type
Please consult with SMC if using coolant liquid other than water based solution.
Indicator light/Display method
D-F7BA(V)L (With indicator light)
Auto switch model
Electrical entry direction
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-F7BAL
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
5 to 40 mA
4 V or less
0.8 mA or less at 24 VDC
Operating position······Red LED lights when ON.
Optimum operating position······Green LED lights when ON.
D-F7BAVL
Perpendicular
8.5
15
6.2 3.2
11
23
SMC
8
15
7
15
ø3.4
D-F7BAL
D-F7BAVL
Auto switch model
0.5
3
5
D-F7BA
50
81
D-F7BAV
50
81
Lead wire length
(m)
In-line
Lead wire — Oil resistant vinyl heavy-duty cord, ø3.4, 0.2 mm2, 2 cores (Brown, Blue), 3 m (Standard) Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
Weight
(g)
ø3.2 mounting hole
Most sensitive position
Indicator light
ø3.2 mounting hole
Most sensitive position
Indicator light
Precautions
Operating range
Indication
GreenRed Red
Optimum operating position
Water Resistant 2-color Indication Type Solid State Switch: Rail Mounting Style
D-F7BA(V)L
Main circuit
of switch
Caution
OUT (+) Brown
OUT (–) Blue
For details about certified products conforming to international standards, visit us at www.smcworld.com.
22
12-13-22
Page 23
Water Resistant 2-color Indication Type Solid State Switch: Direct Mounting Style
D-F9BAL
For details about certified products conforming to international standards, visit us at www.smcworld.com.
23
Grommet
Water (coolant) resistant type
Caution
Precautions
Please consult with SMC if using coolant liquid other than water based solution.
Auto Switch Internal Circuit
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
D-F9BAL (With indicator light)
Auto switch model
Wiring type
Output type
Applicable load
Power supply voltage
Current consumption
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
• Lead wire — Oil resistant vinyl heavy-duty cord, ø2.7, 2 cores (Brown, Blue), 0.18 mm2, 0.5 m Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
Operating position······Red LED lights when ON.
Optimum operating position······Green LED lights when ON.
D-F9BAL
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
5 to 30 mA
5 V or less
1 mA or less at 24 VDC
Weight
Auto switch modelAuto switch model
Lead wire length
(m)
0.5
3
5
D-F9BA
37
57
(g)
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
OUT (+) Brown
of switch
Main circuit
OUT (–) Blue
Indicator light/Display method
Operating range
Indication
Green
Red Red
Optimum operating position
Dimensions
M2.5 x 4l
Slotted set screw
Indicator light
Most sensitive position
20-
ø2.7
12-13-23
Page 24
Auto Switch Internal Circuit
Dimensions
Grommet
Auto switch model
0.5
3
5
D-Y7BA
54
88
Lead wire length
(m)
Water (coolant) resistant type
Please consult with SMC if using coolant liquid other than water based solution.
Indicator light/Display method
D-Y7BAL (With indicator light)
Auto switch model
Wiring type
Applicable load
Load voltage
Load current
Internal voltage drop
Leakage current
Indicator light
D-Y7BAL
2-wire
24 VDC Relay, PLC
24 VDC (10 to 28 VDC)
5 to 40 mA or less
4 V or less
0.8 mA or less at 24 VDC
Operating position······Red LED lights when ON.
Optimum operating position······Green LED lights when ON.
Lead wire — Oil resistant, flexible vinyl heavy-duty cord, ø3.4, 0.15 mm2, 2 cores (Brown, Blue), 3 m
(Standard) Note 1) Regarding the common specifications of the solid state switches, refer to page 12-13-5. Note 2) Regarding the lead wire length, refer to page 12-13-5.
Auto Switch Specifications
PLC: Abbreviation of Programmable Logic Controller
Weight
(g)
Precautions
Operating range
Indication
GreenRed Red
Optimum operating position
Water Resistant 2-color Indication Type Solid State Switch: Direct Mounting Style
D-Y7BAL
Main circuit
of switch
OUT (+) Brown
OUT (–) Blue
Mounting screw M2.5 x 4l
Slotted set screw
Indicator light
Most sensitive position
Caution
For details about certified products conforming to international standards, visit us at www.smcworld.com.
24
12-13-24
Page 25

Made to Order Specifications: Solid State Switch

With Pre-wired Connector

1
With Pre-wired Connector
• Eliminates the harnessing work by cable with connector specifications
• Adopts global standardized connector (IEC947-5-2)
• IP67 construction
For details about certified products conforming to international standards, visit us at www.smcworld.com.
25
MHZ
MHF
MHL
MHR
D— M9N S A PC
Solid state switch Standard part no.
For the applicable auto switch
model, refer to the table below.
S M L
Note) L is available for
Applicable Auto Switch
Mounting
Rail mounting style
Band mounting style
Tie-rod mounting style
Function
2-color
indication
With diagnostic
Water resistant
With timer
Magnetic field
2-color
indication
Diagnostic output
Water resistant
With timer
Wide detection
2-color indication
Diagnostic output
Water resistant
With timer
Electrical
entry
Grommet (In-line)
Grommet
(Perpendicular)
Grommet (In-line)
Grommet
(Perpendicular)
Grommet
(In-line)
Cable length
0.5 m
1.0 m
3.0 m
the D-P5DW type only.
Applicable model
F79, F7P, J79
F7NV, F7PV, F7BV
F79W, F7PW, J79W
F7NWV, F7BWV
F79F
F7BA
F7NT
P5DW
H7A1, H7A2, H7B
G59, G5P, K59
H7NW, H7PW, H7BW
G59W, G5PW, K59W
H7NF, G59F
H7BA, G5BA
G5NT
G5NB
F59, F5P, J59
F59W, F5PW, J59W
F59F
F5BA
F5NT
How to Order
Connector model
A
M8—3 pin
B
M8—4 pin
D
M12—4 pin
Note) Type D is available
for the D-P5DW type only.
Lead wire length
0.5
1.0 3.0
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
Mounting
Direct
mounting style
Rotary
actuator
Connector Specifications
Connector model
Pin arrangement
Conformed standard
Impact resistance
Enclosure
Insulation resistance
Withstand voltage
Function
2-color
indication
Water resistant
With timer
M8–3 pin M8–4 pin M12–4 pin
14
3
JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402
1500 VAC 1 minute (between contacts), Leak current 1 mA or less
Electrical
entry
Grommet
(In-line)
Grommet
(Perpendicular)
Grommet (In-line)
Grommet
(Perpendicular)
Grommet
(In-line)
Grommet
(Perpendicular)
Grommet (In-line)
Grommet
(Perpendicular)
Grommet
(In-line)
Grommet
(In-line)
Grommet
(Perpendicular)
12
3
IP-67 (IEC529 standard)
100 M or more at 500 M VDC
Applicable model
M5N, M5P, M5B
Y59A, Y7P, Y59B
Y69A, Y7PV, Y69B
M9N, M9P, M9B
M9NV, M9PV, M9BV
M5NW, M5PW, M5BW
Y7NW, Y7PW, Y7BW
Y7NWV, Y7PWV, Y7BWV
F9NW, F9PW, F9BW
F9NWV, F9PWV, F9BWV
Y7BA, F9BA
M5NT, M5PT
S791/2, S7P1/2, T791/2
S991/2, S9P1/2, T991/2
S99V1/2, T99V1/2
300 m/s2
4
12
34
Lead wire length
0.5
1.0 3.0
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
앬앬
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
12-13-25
Page 26
Connector Pin Arrangement
Dimensions
Sensor type
DC 2-wire type
DC 2-wire, Non-polar type
DC 3-wire type
DC 4-wire type
Brown
Brown
Brown
1 pin
Orange
2 pin
Brown
Blue
Blue
3 pin
Blue
Blue
Black
Black
4 pin
Color distinction of lead wire Meaning of contact number
OUT (+)
DC (+)
DC (+)
1 pin
Diagnostic
output
2 pin
OUT (±)
DC (–)
DC (–)
3 pin 4 pin
Connection (Female side) Connector Cable
Connector size
M8
M12
Corrence Corporation
OMROM Corporation
Corrence Corporation
OMROM Corporation
Yamatake-Honeywell Co., Ltd.
Hirose Electric Co., Ltd.
DKK Ltd.
M8-3D
M8-4D
XS3
VA-4D
XS2
PA5-4I
HR24
CM01-8DP4S
Manufacturer
3
4
Number of pins
Applicable series example
Connector model
M8—3 pin
4 pin
M12—4 pin
As the parts are not supplied from SMC, refer to the application examples listed in the below. (For detail such as catalog availability, etc., please contact each manufacturer.)
ø14
44
Sensor section
ø10
31.4
Sensor section
Connector Specifications
Connector model
M8–3 pin M8–4 pin M12–4 pin
JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402
300 m/s2
IP-67 (IEC529 standard)
100 M or more at 500 M VDC
1500 VAC 1 minute (between contacts), Leak current 1 mA or less
12
34
14
3
12
4
3
M8—4 pin
M12—4 pin
OUT (–)
OUT ( )
OUT
OUT
±
M8—3 pin
Pin arrangement
Conformed standard
Impact resistance
Enclosure
Insulation resistance
Withstand voltage
With Pre-wired Connector
26
12-13-26
Page 27
Made to Order Specifications: Solid State Switch

-50: No Indicator (Dark room) Specifications

-61: Oil Resistant, Flexible Cable Specifications

2
Without Indicator Light (for dark room specifications)
Possible to use under the environment which hates a light.
27
Symbol
-50
D
Solid state switch model
Applicable part no.:
Dimensions and specifications are common as standard products with the exception of no indicator light.
3
Oil Resistant, Flexible Heavy-duty Cord Specifications
General purpose type, solid state switch except D-J51
Please consult with
Note)
SMC for water resistant type, timer equipped type, output dialysis type, wide range detection type, magnetic field resistant type, heat resistant type.
50
Without indicator light (for dark room specifications)
Lead wire length
For lead wire length, refer to page 12-13-5.
Symbol
-61
This is the product which uses a heavy-duty cord having flexible characteristics 5 times (SMC comparison) as strong as oil resistant heavy-duty cord used in the standard products.
MHZ
MHF
MHL
MHR
MHK
MHS
MHC
MHT
MHY
MHW
MRHQ
Misc.
D-
20-
D
Solid state switch part no.
Applicable part no:
Specifications are the same as standard products with the exception of lead wire specifications. Lead wire: For D-F8, F9 type······ ø2.7, 0.15 mm For other model nos.··················· ø3.4, 0.15 mm
Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type. Lead wire diameter is changed from ø4 to ø3.4. In other series products, it is common as standard product's specifications.
All the solid state switches with the exceptance of D-J51, output diagnostic type, terminal conduit type, connector type, magnetic field resistant type, heat resistant type
Oil resistant flexible
Note)
cabtire cord is used for
A B
D-Y59 , Y69 , Y7P(V) as standard. No need to suffix -61 to the end of part number.
2
, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue)
2
, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue)
Lead wire length
A B
61
Oil resistant, flexible heavy-duty cord specifications
For lead wire length, refer to page 12-13-5.
12-13-27