Smc SMC6924M, SMC6912M Management guide

TigerSwitch 10/100
Stackable Fast Ethernet Switch
12/24 10BASE-T/100BASE-TX ports
Optional 100BASE-FX or 1000BASE-SX modules
Optional stack module for linking up to four units
8.8 Gbps of aggregate switch bandwidth
Support for redundant power unit
Up to five port trunks per switch
Port mirroring for non-intrusive analysis
Full support for VLANs with GVRP
IGMP multicast filtering and snooping
Manageable via console, Web, SNMP/RMON
Management Guide
SMC6912M SMC6924M
TigerSwitch 10/100 Management Guide
From SMC’s Tiger line of feature-rich workgroup LAN solutions
6 Hughes Irvine, CA 92618 Phone: (949) 707-2400
February 2001
Pub. # F2.42 150073-102 R06
Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and reliable. However, no responsibility is assumed by SMC for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice.
Copyright © 2001 by
SMC Networks, Inc.
6 Hughes
Irvine, CA 92618
All rights reserved. Printed in Taiwan
Trademarks:
SMC is a registered trademark; and EZ Switch, TigerStack and TigerSwitch are trademarks of SMC Networks, Inc. Other product and company names are trademarks or registered trademarks of their respective holders.
L
IMITED WARRANTY
Limited Warranty
Limited Warranty Statement: SMC Networks, Inc. (“SMC”) warrants its products
to be free from defects in workmanship and materials, under normal use and service, for the applicable warranty term. All SMC products carry a standard 90-day limited warranty from the date of purchase from SMC or its Authorized Reseller. SMC may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term. SMC will endeavor to repair or replace any product returned under warranty within 30 days of receipt of the product.
The standard limited warranty can be upgraded to a Limited Lifetime* warranty by registering new products within 30 days of purchase from SMC or its Authorized Reseller. Registration can be accomplished via the enclosed product registration card or online via the SMC web site. Failure to register will not affect the standard limited warranty. The Limited Lifetime warranty covers a product during the Life of that Product, which is defined as the period of time during which the product is an “Active” SMC product. A product is considered to be “Active” while it is listed on the current SMC price list. As new technologies emerge, older technologies become obsolete and SMC will, at its discretion, replace an older product in its product line with one that incorporates these newer technologies. At that point, the obsolete product is discontinued and is no longer an “Active” SMC product. A list of discontinued products with their respective dates of discontinuance can be found at http://www.smc.com/smc/pages_html/support.html.
All products that are replaced become the property of SMC. Replacement products may be either new or reconditioned. Any replaced or repaired product carries either a 30-day limited warranty or the remainder of the initial warranty, whichever is longer. SMC is not responsible for any custom software or firmware, configuration information, or memory data of Customer contained in, stored on, or integrated with any products returned to SMC pursuant to any warranty. Products returned to SMC should have any customer-installed accessory or add-on components, such as expansion modules, removed prior to returning the product for replacement. SMC is not responsible for these items if they are returned with the product.
Customers must contact SMC for a Return Material Authorization number prior to returning any product to SMC. Proof of purchase may be required. Any product returned to SMC without a valid Return Material Authorization (RMA) number clearly marked on the outside of the package will be returned to customers at customer’s expense. For warranty claims within North America, please call our toll-free customer support number at (800) 762-4968. Customers are responsible for all shipping charges from their facility to SMC. SMC is responsible for return shipping charges from SMC to customer.
WARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMC’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU
L
IMITED WARRANTY
OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SMC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. SMC SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD.
LIMITATION OF LIABILITY: IN NO EVENT, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), SHALL SMC BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE, LOSS OF BUSINESS, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF SMC OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE. NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS.
* SMC will provide warranty service for one year following discontinuance from the active SMC price list. Under the limited lifetime warranty, internal and external power supplies, fans, and cables are covered by a standard one-year warranty from date of purchase.
SMC Networks, Inc.
6 Hughes
Irvine, CA 92618
T
ABLE OF
C
ONTENTS
1 Switch Management . . . . . . . . . . . . . . . . . . . . . . 1-1
Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Required Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Console Port (Out-of-Band) Connections . . . . . . . . . . . . 1-2
Remote Management via the Console Port . . . . . . . . . . . 1-3
Configure the Switch Site . . . . . . . . . . . . . . . . . . . . 1-3
Configure the Remote Site . . . . . . . . . . . . . . . . . . . 1-3
In-Band Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
2 Using the System Configuration Program . . . . . 2-1
Login Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
System Information Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
Displaying System Information . . . . . . . . . . . . . . . . . . . 2-7
Displaying Switch Version Information . . . . . . . . . . . . . 2-8
Management Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Changing the Network Configuration . . . . . . . . . . . . . 2-11
IP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
IP Connectivity Test (Ping) . . . . . . . . . . . . . . . . . . 2-14
HTTP Configuration . . . . . . . . . . . . . . . . . . . . . . . 2-15
Configuring the Serial Port . . . . . . . . . . . . . . . . . . . . . 2-16
Assigning SNMP Parameters . . . . . . . . . . . . . . . . . . . . 2-18
Configuring Community Names . . . . . . . . . . . . . . 2-19
Configuring IP Trap Managers . . . . . . . . . . . . . . . 2-20
Console Login Configuration . . . . . . . . . . . . . . . . . . . . 2-21
Downloading System Software . . . . . . . . . . . . . . . . . . 2-23
Using TFTP to Download Over the Network . . . . . 2-23
Saving the System Configuration . . . . . . . . . . . . . . . . . 2-24
Configuring the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-26
Configuring Port Parameters . . . . . . . . . . . . . . . . . . . . 2-28
Viewing the Current Port Configuration . . . . . . . . . . . . 2-29
Using the Spanning Tree Algorithm . . . . . . . . . . . . . . . 2-30
Configuring Bridge STA . . . . . . . . . . . . . . . . . . . . 2-31
Configuring STA for Ports . . . . . . . . . . . . . . . . . . . 2-33
Viewing the Current Spanning Tree Information . . . . . 2-34
Displaying the Current Bridge STA . . . . . . . . . . . . 2-35
i
T
ABLE OF CONTENTS
Displaying the Current STA for Ports . . . . . . . . . . 2-36
Using a Mirror Port for Analysis . . . . . . . . . . . . . . . . . 2-38
Configuring Port Trunks . . . . . . . . . . . . . . . . . . . . . . 2-39
IGMP Multicast Filtering . . . . . . . . . . . . . . . . . . . . . . . 2-42
Configuring IGMP . . . . . . . . . . . . . . . . . . . . . . . . 2-43
Configuring Broadcast Storm Control . . . . . . . . . . . . . 2-44
Configuring Bridge MIB Extensions . . . . . . . . . . . . . . 2-45
Configuring Traffic Classes . . . . . . . . . . . . . . . . . . . . . 2-47
Port Priority Configuration . . . . . . . . . . . . . . . . . . 2-48
802.1p Port Traffic Class Information . . . . . . . . . . 2-49
Configuring Virtual LANs . . . . . . . . . . . . . . . . . . . . . 2-50
802.1Q VLAN Base Information . . . . . . . . . . . . . . 2-50
802.1Q VLAN Current Table Information . . . . . . . 2-51
802.1Q VLAN Static Table Configuration . . . . . . . . 2-53
802.1Q VLAN Port Configuration . . . . . . . . . . . . . 2-55
Port Security Configuration . . . . . . . . . . . . . . . . . . . . 2-57
Monitoring the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-59
Displaying Port Statistics . . . . . . . . . . . . . . . . . . . . . . 2-60
Displaying RMON Statistics . . . . . . . . . . . . . . . . . . . . 2-62
Displaying the Unicast Address Table . . . . . . . . . . . . . 2-64
Displaying the IP Multicast Registration Table . . . . . . . 2-66
Configuring Static Unicast Addresses . . . . . . . . . . . . . 2-67
Resetting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69
Logging Off the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-69
3 Web-Based Management . . . . . . . . . . . . . . . . . . . 3-1
Web-Based Configuration and Monitoring . . . . . . . . . . . . . . . 3-1
Navigating the Web Browser Interface . . . . . . . . . . . . . . . . . . 3-2
Home Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Configuration Options . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Panel Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Port State Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Console Configuration . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Switch Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
Main Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9
ii
T
ABLE OF CONTENTS
Agent Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
Expansion Slot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
IP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
SNMP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
SNMP Community . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13
Trap Managers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14
Security Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Change Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-15
Firmware Upgrade Options . . . . . . . . . . . . . . . . . . . . . . . . . 3-16
Web Upload Management . . . . . . . . . . . . . . . . . . . . . 3-16
TFTP Download Management . . . . . . . . . . . . . . . . . . . 3-17
Configuration Save and Restore . . . . . . . . . . . . . . . . . . . . . . 3-18
Configuration Upload Management . . . . . . . . . . . . . . . 3-18
Configuration Download Management . . . . . . . . . . . . 3-19
Address Table Configuration . . . . . . . . . . . . . . . . . . . . . . . . 3-20
Spanning Tree Algorithm (STA) . . . . . . . . . . . . . . . . . . . . . . 3-21
Spanning Tree Information . . . . . . . . . . . . . . . . . . . . . 3-21
Spanning Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-22
Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-23
Spanning Tree Configuration . . . . . . . . . . . . . . . . . . . 3-25
Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-25
When the Switch Becomes Root . . . . . . . . . . . . . . 3-25
STA Port Configuration . . . . . . . . . . . . . . . . . . . . . . . . 3-27
Configuring Bridge MIB Extensions . . . . . . . . . . . . . . . . . . . 3-29
Bridge Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-29
Bridge Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-30
Priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-31
Port Priority Configuration . . . . . . . . . . . . . . . . . . . . . 3-31
Port Traffic Class Information . . . . . . . . . . . . . . . . . . . 3-32
Configuring Virtual LANs . . . . . . . . . . . . . . . . . . . . . . . . . . 3-33
VLAN Basic Information . . . . . . . . . . . . . . . . . . . . . . . 3-33
VLAN Current Table . . . . . . . . . . . . . . . . . . . . . . . . . . 3-34
VLAN Static List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-35
VLAN Static Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-36
VLAN Static Membership by Port . . . . . . . . . . . . . . . . . 3-38
VLAN Port Configuration . . . . . . . . . . . . . . . . . . . . . . 3-39
IGMP Multicast Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-40
iii
T
ABLE OF CONTENTS
Configuring IGMP . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-41
IP Multicast Registration Table . . . . . . . . . . . . . . . . . 3-42
Port Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
Port Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-43
Port Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44
Port Broadcast Storm Protect Configuration . . . . . . . . 3-46
Port Security Configuration . . . . . . . . . . . . . . . . . . . . 3-47
Using a Port Mirror for Analysis . . . . . . . . . . . . . . . . . . . . . . 3-48
Port Trunk Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 3-49
Port Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52
Etherlike Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-52
RMON Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54
4 Advanced Topics . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Layer 2 Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Spanning Tree Algorithm . . . . . . . . . . . . . . . . . . . . . . . 4-2
Virtual LANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Assigning Ports to VLANs . . . . . . . . . . . . . . . . . . . . . . . 4-4
Port Overlapping . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Automatic VLAN Registration (GVRP) . . . . . . . . . . . . . . 4-5
Forwarding Traffic with Unknown VLAN Tags . . . . 4-6
Forwarding Tagged/Untagged Frames . . . . . . . . . . . . . 4-6
Connecting VLAN Groups . . . . . . . . . . . . . . . . . . . . . . 4-7
Multicast Filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
IGMP Snooping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
IGMP Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8
Class-of-Service (CoS) Support . . . . . . . . . . . . . . . . . . . . . . . 4-9
Port Trunks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-9
SNMP Management Software . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Remote Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
Troubleshooting Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Upgrading Firmware via the Serial Port . . . . . . . . . . . . . . . . . A-2
iv
T
ABLE OF CONTENTS
B Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . B-1
Console Port Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . .B-1
DB-9 Port Pin Assignments . . . . . . . . . . . . . . . . . . . . . .B-2
Console Port to 9-Pin COM Port on PC . . . . . . . . . . . . .B-2
Console Port to 25-Pin DCE Port on Modem . . . . . . . . .B-2
Console Port to 25-Pin DTE Port on PC . . . . . . . . . . . . .B-3
Glossary
Index
v
T
ABLE OF CONTENTS
vi
C
HAPTER
S
WITCH
M
ANAGEMENT

Configuration Options

For advanced management capability, the TigerSwitch 10/100 management agent provides a menu-driven system configuration program. This program can be accessed by a direct or modem connection to the serial port on the rear panel (out-of-band), or by a Telnet connection over the network (in-band).
The management agent is based on SNMP (Simple Network Management Protocol). This SNMP agent permits the switch to be managed from any PC in the network using in-band management software (such as SMCs EliteView).
The management agent also includes an embedded HTTP Web agent. This Web agent can be accessed using a standard Web browser from any computer attached to the network.
1
The system configuration program and the SNMP agent support management functions such as:
Enable/disable any port
Set the communication mode for any port
Configure SNMP parameters
Configure VLANs or multicast filtering
Display system information or statistics
Configure the switch to join a Spanning Tree
Download system firmware
Restart the system
1-1
S
WITCH MANAGEMENT

Required Connections

Console Port (Out-of-Band) Connections

Attach a VT100 compatible terminal or a PC running a terminal emulation program to the serial port on the switchs rear panel. Use the null-modem cable provided with this package, or use a null modem connection that complies with the wiring assignments shown in Appendix B of this guide.
When attaching to a PC, set terminal emulation type to VT100, specify the port used by your PC (i.e., COM 1~4), and then set communications to 8 data bits, 1 stop bit, no parity, and 19200 bps (for initial configuration). Also be sure to set flow control to none. (Refer to Configuring the Serial Port on page 2-16 for a complete description of configuration options.)
Note: If the default settings for the management agents serial port
have been modified and you are having difficulty making a console connection, you can display or modify the current settings using a Web browser as described under “Console Configuration on page 3-5.
1-2
S
WITCH MANAGEMENT

Remote Management via the Console Port

Configure the Switch Site
Connect the switchs DB9 serial port to the modems serial port using standard cabling. For most modems which use a 25-pin port, you will have to provide an RS-232 cable with a 9-pin connector on one end and a 25-pin connector on the other end. Set the modem at the switchs site to force auto-answer mode. The following is a sample initialization string: “ATQ 1S0=1&D0&K0&W” as defined below:
Q1 : Inhibit result codes to DTE S0=1 : Auto answer on first ring D0 : Dont care DTR K0 : Disables DTE/DCE flow control W : Write command to modem memory
Configure the Remote Site
At the remote site, connect the PCs COM port (COM 1~4) to the modems serial port. Set terminal emulation type to VT100, specify the port used by your PC (i.e., COM 1~4), and then set communications to 8 data bits, 1 stop bit, no parity, 19200 bps and no flow control.
1-3
S
WITCH MANAGEMENT

In-Band Connections

Prior to accessing the Network Management Module via a network connection, you must first configure it with a valid IP address, subnet mask, and default gateway using an out-of-band connection or the BOOTP protocol.
After configuring the switchs IP parameters, you can access the on-board configuration program from anywhere within the attached network. The on-board configuration program can be accessed using Telnet from any computer attached to the network. The switch and stack can also be managed by any computer using a Web browser (Internet Explorer 4.0, or Netscape Navigator 4.0 or above), or from a network computer using network management software such as EliteView.
Notes: 1. By default BOOTP is disabled. To enable BOOTP, see
IP Configuration on page 2-12.
2. Use the Network Configuration menu to specify the maximum number of simultaneous Telnet sessions that are supported by the system (up to four).
1-4
3. The on-board program only provides access to basic configuration functions. To access the full range of SNMP management functions, you must use SNMP­based network management software, such as SMC’s free EliteView software.
C
HAPTER
U
SING THE
C
ONFIGURATION
S
P
ROGRAM

Login Screen

Once a direct connection to the serial port or a Telnet connection is established, the login screen for the on-board configuration program appears as shown below.
SSSSSSSSSSSSSSS MMMMM MMMMM CCCCCCCCCCCCCC SSSSSSSSSSSSSSSSS MM MM CCCCCCCCCCCCCCCC SS S MMM MMM CCC CC SS MMMM MMMM CCC
SSSSSSSSSSSSSSSS MM MM MM MM CCC
S SS MMMMMMMM CCC CC SSSSSSSSSSSSSSSSS MM MMM MM CCCCCCCCCCCCCCCC
SSSSSSSSSSSSSSS MMMM MMMMM MMMM CCCCCCCCCCCCCC
V2.42 12-13-2000 (c)Copyright 2000, SMC Networks Inc.
SS MM MM MM MM CCC CC
TigerSwitch 10/100 SMC6912M/6924M
User name : Password :
2
YSTEM
If this is your first time to log into the configuration program, then the default user names are “admin” and “guest,” with no password. The administrator has Read/Write access to all configuration parameters and statistics. While the guest has Read Only access to the management program.
2-1
U
SING THE SYSTEM CONFIGURATION PROGRAM
You should define a new administrator password, record it and put it in a safe place. Select Console Login Configuration from the Management Setup Menu and enter a new password for the administrator. Note that passwords can consist of up to 11 alphanumeric characters and are not case sensitive.
Note: Based on the default configuration, a user is allowed three
attempts to enter the correct password; on the third failed attempt the current connection is terminated.
After you enter the user name and password, you will have access to the system configuration program as illustrated by the following menu hierarchy:
System Information Menu
Management Setup Menu
System Information Switch Information
Network Configuration Serial Port Configuration SNMP Configuration Console Login Configuration TFTP Download Configuration Save & Restore
IP Configuration IP Connectivity Test(Ping) HTTP Configuration
SNMP Communities IP Trap Managers
Device Control Menu
Network Monitor Menu
System Restart Menu
Exit
Port Configuration Port Information Spanning Tree Configuration Spanning Tree Information
Port Configuration
Mirror Port Trunking Configuration IGMP Configuration BStorm Control Configuration Extented Bridge Configuration
802.1P Configuration
802.1Q VLAN Base Information
802.1Q VLAN Current Table Information
802.1Q VLAN Static Table Configuration
802.1Q VLAN Port Configuration Port Security Configuration Port GARP Configuration* Port GMRP Configuration*
Port Statistics RMON Statistics Unicast Address Table Multicast Address Registration Table* IP Multicast Registration Table Static Unicast AddressTable Configuration Static Multicast AddressTable Configuration*
* Not implemented in this firmware release.
2-2
STA Bridge Configuration STA Port Configuration
STA Bridge Information STA Port Information
802.1P Port Priority Configuration
802.1P Port Traffic Class Information
U
SING THE SYSTEM CONFIGURATION PROGRAM

Main Menu

With the system configuration program you can define system parameters, manage and control the switch, the connected stack and all its ports, or monitor network conditions. The figure below of the Main Menu and the following table briefly describe the selections available from this program.
Note: Options for the currently selected item are displayed in the
highlighted area at the bottom of the interface screen.
Main Menu =========
System Information Menu...
Management Setup Menu...
Device Control Menu...
Network Monitor Menu...
Restart System Menu...
Exit
Use <TAB> or arrow keys to move. <Enter> to select.
Menu Description
System Information Menu
System Information Provides basic system description, including
contact information.
Switch Information Shows hardware/firmware version numbers,
power status, and expansion modules used in the stack.
2-3
U
SING THE SYSTEM CONFIGURATION PROGRAM
Menu Description
Management Setup Menu
Network Configuration Includes IP setup, Ping facility, HTTP (Web
agent) setup, Telnet configuration, and MAC address.
Serial Port Configuration Sets communication parameters for the serial
SNMP Configuration Activates traps; and configures communities
Console Login Configuration
TFTP Download Downloads new version of firmware to update
Configuration Save & Restore
Device Control Menu
Port Configuration Enables any port, enables/disables flow
Port Information Displays operational status, including link
Spanning Tree Configuration
Spanning Tree Information
Port Mirror Configuration Sets the source and target ports for mirroring.
Port Trunking Configuration
IGMP Configuration Configures IGMP multicast filtering.
BStorm Control Configuration
port, including management mode, baud rate, console time-out, and screen data refresh interval.
and trap managers.
Sets user names and passwords for system access, as well as the invalid password threshold and lockout time.
your system (in-band).
Saves the switch configuration to a file on a TFTP server. This file can be later downloaded to restore the configuration.
control, and sets communication mode to auto-negotiation, full duplex or half duplex.
state, flow control method, and duplex mode.
Enables Spanning Tree Algorithm; also sets parameters for hello time, maximum message age, switch priority, and forward delay; as well as port priority, path cost, and fast forwarding.
Displays full listing of parameters for the Spanning Tree Algorithm.
Specifies ports to group into aggregate trunks.
Allows you to enable/disable broadcast storm control on a per-port basis and set the packet-per-second threshold.
2-4
U
SING THE SYSTEM CONFIGURATION PROGRAM
Menu Description
Extended Bridge Configuration
802.1P Configuration Configures default port priorities and queue
802.1Q VLAN Base Information
802.1Q VLAN Current Table Information
802.1Q VLAN Static Table Configuration
802.1Q VLAN Port Configuration
Port Security Configuration
Port GARP Configuration* Configures settings used in multicast filtering.
Port GMRP Configuration* Configures GMRP multicast filtering.
Network Monitor Menu
Port Statistics Displays statistics on network traffic passing
RMON Statistics Displays detailed statistical information for the
Unicast Address Table Provides full listing for unicast addresses, as
Multicast Address Registration Table*
IP Multicast Registration Table
Static Unicast Address Table Configuration
Displays/configures extended bridge capabilities provided by this switch.
assignments.
Displays basic VLAN information, such as VLAN version number and maximum VLANs supported.
Displays VLAN groups and port members.
Configures VLAN groups via static assignments, including setting port members, or restricting ports from being dynamically added to a port by the GVRP protocol.
Displays/configures port-specific VLAN settings, including PVID, ingress filtering, and GVRP.
Allows you to enable and configure port security for the switch.
through the selected port.
selected port such as packet type and frame size counters.
well as search and clear functions.
Provides full listing for multicast addresses, as well as search and clear functions.
Displays all the multicast groups active on this switch, including multicast IP addresses and corresponding VLAN IDs.
Used to manually configure host MAC addresses in the unicast table.
2-5
U
SING THE SYSTEM CONFIGURATION PROGRAM
Menu Description
Static Multicast Address Table Configuration*
Restart System Restarts system with options to use POST, or
Exit Exits the configuration program.
Not implemented in this firmware release.
*
Used to manually configure host MAC addresses in the multicast table.
to retain factory defaults, IP settings, or user authentication settings.

System Information Menu

Use the System Information Menu to display a basic description of the switch, including contact information, and hardware/firmware versions.
System Information Menu =======================
System Information ...
Switch Information ...
Use <TAB> or arrow keys to move. <Enter> to select
Menu Description
System Information Provides basic system description, including
Switch Information Shows hardware/firmware version numbers,
<OK>
contact information.
power status, and expansion modules used in the stack.
2-6
U
SING THE SYSTEM CONFIGURATION PROGRAM

Displaying System Information

Use the System Information screen to display descriptive information about the switch, or for quick system identification as shown in the following figure and table.
System Information ==================
System Description : TigerSwitch 10/100 SMC6912M/6924M
System Object ID : 1.3.6.1.4.1.202.20.6
System Up Time : 48067 (0 day, 1 hr, 2min, 34 sec)
System Name : DEFAULT SYSTEM NAME
System Contact : DEFAULT SYSTEM CONTACT
System Location : DEFAULT SYSTEM LOCATION
<APPLY> <OK> <CANCEL>
Use <TAB> or arrow keys to move, other keys to make changes.
Parameter Description
System Description System hardware description.
System Object ID MIB II object identifier for switchs network
System Up Time Length of time the current management
System Name* Name assigned to the switch system.
System Contact* Contact person for the system.
System Location* Specifies the area or location where the
Maximum string length is 255, but the screen only displays 45 characters.
*
You can use the arrow keys to browse the whole string.
management subsystem.
agent has been running. (Note that the first value is 1/100 seconds.)
system resides.
2-7
U
SING THE SYSTEM CONFIGURATION PROGRAM

Displaying Switch Version Information

Use the Switch Information screen to display hardware/firmware version numbers for the main board, as well as the power status.
Switch Information : Unit 1 ==================
Hardware Version : V3.0 Firmware Version : V1.11 Serial Number : 00-CB-00-00-00-00 Port Number : 24 Internal Power Status : Active Redundant Power Status : Inactive Expansion Slot 1 : --------------------­Expansion Slot 2 : ---------------------
Hardware Version : V3.0 (801 CPU) POST ROM Version : V1.10 Firmware Version : V2.42 SNMP Agent : Master
<OK> <PREV UNIT> <NEXT UNIT>
Use <TAB> or arrow keys to move. <Enter> to select
Main Board
Agent Module
Parameter Description
Main Board
Hardware Version Hardware version of the main board.
Firmware Version System firmware version in ROM.
Serial Number The serial number of the main board.
Port Number Number of ports (including modules).
Internal Power Status Indicates if the primary power is active or
inactive.
Redundant Power Status Indicates if the redundant power is active or
inactive.
Expansion Slot 1 Shows module type if inserted
(100BASE-FX or 1000BASE-SX).
Expansion Slot 2
Shows module type if inserted (100BASE-FX or 1000BASE-SX or 4GB Stack).
2-8
U
SING THE SYSTEM CONFIGURATION PROGRAM
Parameter Description
Agent Module
Hardware Version Hardware version of the agent module.
POST ROM Version Power-On Self-Test version number.
Firmware Version Firmware version of the agent module.
SNMP Agent Shows that the agent module is operating as
Master.
2-9
U
SING THE SYSTEM CONFIGURATION PROGRAM

Management Setup Menu

After initially logging onto the system, adjust the communication parameters for your console to ensure a reliable connection (Serial Port Configuration). Specify the IP addresses for the switch (Network Configuration / IP Configuration), and then set the Administrator and User passwords (Console Login Configuration). Remember to record them in a safe place. Also set the community string which controls access to the on-board SNMP agent via in-band management software (SNMP Configuration). The items provided by the Management Setup Menu are described in the following sections.
Management Setup Menu =====================
Network Configuration ... Serial Port Configuration ... SNMP Configuration ... Console Login Configuration ... TFTP Download ... Configuration Save & Restore ...
Use <TAB> or arrow keys to move. <Enter> to select.
Menu Description
Network Configuration Includes IP setup, Ping facility, HTTP (Web
Serial Port Configuration Sets communication parameters for the serial
SNMP Configuration Activates traps; and configures communities
<OK>
agent) setup, Telnet configuration, and MAC address.
port, including management mode, baud rate, console time-out, and screen data refresh interval.
and trap managers.
2-10
U
SING THE SYSTEM CONFIGURATION PROGRAM
Menu Description
Console Login Configuration
Sets user names and passwords for system access, as well as the invalid password threshold and lockout time.
TFTP Download Downloads new version of firmware to
update your system (in-band).
Configuration Save & Restore
Saves the switch configuration to a file on a TFTP server. This file can be later downloaded to restore the configuration.

Changing the Network Configuration

Use the Network Configuration menu to set the bootup option, configure the switchs Internet Protocol (IP) parameters, enable the on-board Web agent, or to set the number of concurrent Telnet sessions allowed. The screen shown below is described in the following table.
Network Configuration =====================
IP Configuration ... IP Connectivity Test (Ping) ... HTTP Configuration ... MAX Number of allowed Telnet sessions (1 -4) : 4 MAC Address : 00-E0-29-52-28-00
<APPLY> <OK> <CANCEL> Use <TAB> or arrow keys to move. <Enter> to select.
Parameter Description
IP Configuration Screen used to set the bootup option, or
configure the switchs IP parameters.
IP Connectivity Test (Ping) Screen used to test IP connectivity to a
specified device.
HTTP Configuration Screen used to enable the Web agent.
2-11
U
SING THE SYSTEM CONFIGURATION PROGRAM
Parameter Description
MAX Number of Allowed Telnet Sessions
The maximum number of Telnet sessions allowed to simultaneously access the agent module.
MAC Address Physical address of the agent module.
IP Configuration
Use the IP Configuration screen to set the bootup option, or configure the switchs IP parameters. The screen shown below is described in the following table.
Network Configuration : IP Configuration ========================================
Interface Type : Ethernet
IP Address : 10.1.113.29 Subnet Mask : 255.255.0.0 Gateway IP : IP State : USER-CONFIG
<APPLY> <OK> <CANCEL>
Use <TAB> or arrow keys to move, other keys to make changes.
Parameter Description
Interface Type Indicates IP over Ethernet.
IP Address IP address of the stack you are managing. The system
supports SNMP over UDP/IP transport protocol. In this environment, all systems on the Internet, such as network interconnection devices and any PC accessing the agent module (or running EliteView) must have an IP address.
Valid IP addresses consist of four numbers, of 0 to 255, and separated by periods. Anything outside of this format will not be accepted by the configuration program.
Subnet Mask Subnet mask of the switch you have selected. This mask
identifies the host address bits used for routing to specific subnets.
2-12
U
SING THE SYSTEM CONFIGURATION PROGRAM
Parameter Description
Default Gateway Gateway used to pass trap messages from the systems
IP State Specifies whether IP functionality is enabled via manual
agent to the management station. Note that the gateway must be defined if the management station is located in a different IP segment. The default value is null.
configuration, or set by Boot Protocol (BOOTP). Options include:
USER-CONFIG - IP functionality is enabled based on the default or user specified IP Configuration. (This is the default setting.)
BOOTP Get IP - IP is enabled but will not function until a BOOTP reply has been received. BOOTP requests will be periodically broadcast by the switch in an effort to learn its IP address. (BOOTP values can include the IP address, default gateway, subnet mask, and TFTP server IP.)
2-13
U
SING THE SYSTEM CONFIGURATION PROGRAM
IP Connectivity Test (Ping)
Use the IP Connectivity Test to see if another site on the Internet can be reached. The screen shown below is described in the following table.
Network Configuration : IP Connectivity Test (Ping) ===================================================
IP Address :
Test Times : 1 Interval : 3
Success : 0 Failure : 0
[Start]
<APPLY> <OK> <CANCEL>
Use <TAB> or arrow keys to move, other keys to make changes.
Parameter Description
IP Address IP address of the site you want to ping.
Test Times The number of ICMP echo requests to send
Interval The interval (in seconds) between pinging
Success/Failure The number of times the specified site has
to the specified site.
Range: 1~1000
the specified site.
Range: 1~10 seconds
responded or not to pinging.
2-14
Loading...